Wiring Device-Kellems
®
www.hubbell-wiring.com
Hubbell Wiring Device-Kellems • Hubbell Incorporated (Delaware) • 40 Waterview Drive • Shelton, CT 06484 • Phone (800) 288-6000 • FAX (800) 255-1031
Printed in U.S.A. Specications subject to change without notice.
WLFSB003 3/14
DIMENSIONS
ORDERING INFORMATION
Description Color 15 Amp 20 Amp
Outlet Branch Circuit
Arc Fault Receptacle with
Tamper-Resistant Outlets
20A 125V Feed Through
and LED Indicator
Black
Brown
Gray
Ivory
Light Almond
White
AFR15TRBK
AFR15TR
AFR15TRGY
AFR15TRI
AFR15TRLA
AFR15TRW
AFR20TRBK
AFR20TR
AFR20TRGY
AFR20TRI
AFR20TRLA
AFR20TRW
Outlet Branch Circuit AFCI
Blank Face - LED Indicator
Ivory
White
—
—
AFR20BFI
AFR20BFW
The Hubbell “AFR” series meets all requirements for an outlet branch-circuit type AFCI; protects branch circuit wiring and extensions to branches such including appliances and cord sets.
Tamper Resistant
NEC 406.11; 210.52 – All 15 & 20A 125V, Receptacles
shall be listed Tamper-Resistant for dwelling installations.
SPECIFICATIONS
Ratings
Amperage 15 Amp/20 Amp
Feed-thru 20 Amp Protection
Voltage 120V AC (+10% to15%)
(102V to 132V)
Horsepower (1) @ Rated Voltage
Flammability Rated V2 per UL 94
Operating (-35°C to 66°C) or
Temperature (-30°F to 150°F)
Certifications
UL 1699A E366570
UL 498 Receptacle
UL Fed Spec WC-596
CSA Standard C22.2 No. 42
CSA Tech Letter No. M-02A
NEMA WD-6
Construction
Termination Back and Side
Terminal #14-10 AWG
Grounding Self-Grounding Clip
Indicators Power & Rev Wire
Configuration 2 Pole, 3 Wire
NEMA 5-15R, 5-20R
NATIONAL ELECTRIC CODE
2011 NEC 210.12(A) “Where required all 15A or 20A 120V branch circuits in dwelling units that supply outlets to family rooms, dining rooms, living rooms,
parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways or similar areas must be protected by a listed AFCI device of the
combination type.” There are (2) exceptions noted below:
(1) AFCI can be branch circuit type located at the first outlet if circuit conductors installed in RMC, IMC, EMT or Type MC or steel armored Type AC
cable and AFCI device is contained in a metal outlet or box.
(2) Where a listed metal or nonmetallic conduit or tubing is encased in not less than 2 inches of concrete for the portion of the branch circuit between
the branch-circuit overcurrent device and the first outlet, an outlet branch-circuit AFCI at the first outlet is permitted to provide protection for the
remaining portion of the branch circuit.
(B) Branch circuit extensions or modifications – dwelling units. Where branch-circuit wiring is modified, replaced, or extended in any of the areas specified
in 210.12(A), the branch circuit must be protected by a listed combination AFCI located at the origin of the branch circuit; or a a listed outlet branch circuit
AFCI located at the first receptacle outlet of the existing branch circuit”
2014 NEC 406.4(D) “Requirements for replacement receptacles where a receptacle outlet is supplied by a branch circuit that requires arc-fault circuit
interrupter protection [210.12(A)], a replacement receptacle at this outlet must be one of the following: (1) A listed outlet branch circuit type arc-fault circuit
interrupter receptacle; (2) A receptacle protected by a listed outlet branch circuit code arc-fault circuit interrupter code receptacle; (3) A receptacle protected
by a listed combination type arc-fault circuit interrupter type circuit breaker.”
Hubbell Arc Fault Receptacles
Wiring Device-Kellems
®
For Commercial and Residential Applications
1.29"
(32.8)
1.29"
(32.8)
1.07"
(27.2)
1.35"
1.07"
(27.2)
1.43"
1.68"
1.68"
1.31"
(33.3)
1.31"
(33.3)
3.28"
(83.3)
3.81"
(96.8)
2.60"
(66.0)
4.21"
(106.9)
1.29"
(32.8)
1.07"
(27.2)
1.35"
3.28"
(83.3)
3.81"
(96.8)
2.60"
(66.0)
4.21"
(106.9)
15 Amp 20 Amp