Product catalogue | Electronics | Monitoring modules | Voltage monitoring | Analogue output
- 2 -
General data
Type of connection Screw connection
Mounting rail TS 35
Weight 200 g
Current consumption 40...30...24 mA at I =20 mA
Current-carrying capacity of cross-connect. ≤ 2 A
Voltage supply 24 V DC ± 25 %
Default setting 0...10V/0...20mA
Ambient temperature (operational) 0 °C...+50 °C
Storage temperature -20 °C...+70 °C
Insulation coordination
Standards EN 50178
EMC standards EN 61000-6, EN 61000-2-6, EN 61326
Insulation voltage input, output 4 kV / 5 s
Insulation voltage input or output/supply Input/Supply: 4 kV / 5 s; Output/Supply: 2 kV / 5 s
Clearance & creepage distances Supply/output: 3 mm; input/output, supply/output:
5.5 mm
Impulse withstand voltage Supply/output: 4 kV; input/output, supply/output:
6kV
Pollution severity 2
Overvoltage category III
Rated voltage supply/output: 300 V; input/output, supply/output:
600 V
Dimensions
Clamping range, max. 2.5 mm²
Clamping range, min. 0.5 mm²
Clamping range, nom. 2.5 mm²
Length 92.4 mm
Height 112.4 mm
Width 22.5 mm
Approvals
Approvals institutes
Classifications
eClass 4.1 27-21-09-01
eClass 5.0 27-21-09-01
eClass 5.1 27-21-09-01
Similar products
Order No. Part designation Version
8581230000 WAZ2 VMA V ac Voltage monitoring, 0...30 / 0...70 / 0...130 / 0...250 / 0...450 V AC ,
1 , 0(4)...20 mA , 0...10 V , 1 , Tension clamp connection