Notice for TAIYO YUDEN products Please read this notice before using the TAIYO YUDEN products. REMINDERS Product information in this catalog is as of October 2009. All of the contents specified herein are subject to change without notice due to technical improvements, etc. Therefore, please check for the latest information carefully before practical application or usage of the Products. Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this catalog or individual specification. Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is available. Please conduct validation and verification of products in actual condition of mounting and operating environment before commercial shipment of the equipment. All electronic components or functional modules listed in this catalog are developed, designed and intended for use in general electronics equipment.(for AV, office automation, household, office supply, information service, telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance. Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, submarine system, military, etc. where higher safety and reliability are especially required. In addition, even electronic components or functional modules that are used for the general electronic equipment, if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliability evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to install a protective circuit is strongly recommended at customer's design stage. The contents of this catalog are applicable to the products which are purchased from our sales offices or distributors (so called TAIYO YUDEN s official sales channel ). It is only applicable to the products purchased from any of TAIYO YUDEN s official sales channel. Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may occur in connection with a third party's intellectual property rights and other related rights arising from your usage of products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights. Caution for export Certain items in this catalog may require specific procedures for export according to Foreign Exchange and Foreign Trade Control Law of Japan, U.S. Export Administration Regulations , and other applicable regulations. Should you have any question or inquiry on this matter, please contact our sales staff. Should you have any question or inquiry on this matter, please contact our sales staff. 1 notice_e-01 WOUND TORROIDS AND BEADS WAVE FEATURES APPLICATIONS Use of high loss ferrite materials for excellent high frequency noise absorption. Absorption of high frequency noise from digital equipment data lines. High impedance for normal mode applications. OPERATING TEMP. 05 RD type available in taping for automatic insertion. 25105Including self-generated heat 06 BT type is designed for high current applications (3A). ORDERING CODE FL-R / RD Type F L 0 FL 5 R Type Wound torroids and beads D 0 Shape Ring core, with single wire lead Ring core, RD with case, pin type Nominal inductance (H) L 1R0 200 Blank space 0 6 Type FL Wound torroids and beads B A E example A T Inductance tolerance Higher than normal value Special tolerance 1.0 20.0 Rdecimal point FL-BT Type F 0 R Dimensions of core 05 4.8mm 2 T Dimensions of core (diameter) 06 6.0mm Internal code Standard product Product classification code 07 Blank space Blank space Shape Cylinder, porous core BT Packaging Bulk Tape & Reel Ammo Special code 4 0 T Z Product classification code 04 Internal code Standard product Blank space EXTERNAL DIMENSIONS/MINIMUM QUANTITY 05RD Type Fig. 05R 06BT04 3.7max 0.146max 4.01 9.0max 0.1570.039 0.351max 9.0max 0.35max 6.5max 3.0max 0.256max0.118max 15.2max 0.598max 0.6 0.024 6.00.2 0.240.008 0.3 0.012 0.6 5.0 0.2 0.024 0.1970.008 Minimum Quantity (pcs.) Bulk Tape & Reel Ammo 400 2000 1500 500 250 Unit : mm (inch) IMPEDANCE-FREQUENCY CHARACTERISTICS Measured by HP4291A FL05RD / FL05R TYPE FL06BT TYPE Please contact TAIYO YUDEN for further information in regard to other characteristics. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 120 1 filter01_e-01 PART NUMBERS EHS (Environmental Hazardous Substances) Inductance [H] FL05RD 1R0E RoHS 1.01.0 0.5 800 FL05R 100A FL05RD 100A FL05R 200A07 FL05RD 200A FL06BT 04 RoHS RoHS RoHS RoHS RoHS 10 min. 900 20 min. Ordering code Impedance (typical) DC Resistance (max) Rated current A(max) (at 400MHz) 0.08 0.5 (at 200MHz) 0.05 2000 (at 100MHz) 0.08 1000 (at 150MHz) 0.05 1.5 3.0 Please specify the packaging code (T : Tape & reel, Z : ammo, Blank space : bulk) FERRITE PRODUCTS This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. filter01_e-01 1 121 PACKAGING Minimum Quantity Type FL05R FL05RD FL06BT Bulk 500 400 250 Minimum Quantity (pcs.) Tape & Reel 2000 Ammo 1500 Taping dimensions FL05RD Type FL05RD Symbol D1 H2 T H1 H P P0 P1 P2 W1 F Dimension 9.0 max. (0.354 max.) 9.0 max. (0.354 max.) 3.7 max. (0.146 max.) 31.0 max. (1.22 max.) 18.01.0 (0.7090.039) 12.71.0 (0.5000.039) 12.70.3 (0.5000.012) 1 3.850.8 (0.1520.031) 6.351.3 (0.2500.051) 0.030 9.00.75 0.5 (0.3540.020 ) 0.6 5.00.2 (0.1970.024 0.008) d h 0.6 (0.024) 02.0 (00.079) W 0.024 18.01.0 0.5 (0.7090.008) W0 W2 D0 L t 12.5 min. 3.0 min. 0 max. 4.00.3 11.0 max. 0.70.2 1 Accumulated error for 20 pitches shall be within 2mm. 2 Pasting tape shall not exceed paste board. (0.492 min.) (0.118 min.) 2 (0 max.) (0.1570.012) (0.433 max.) (0.0280.008) Unit : mm (inch) Reel size FL05RD Dimensions in parenthesis are measured value. 60 or less 53 2.362 or less 2.087 Unit : mm (inch) This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. filter01_pack-P1 1 filter01_pack_e-01 RELIABILITY DATA 1. Operating temperature Range LA Type CAL45 Type 25105 LHL FBA/FBR 2585 FL05 Type 25105 FL06BT Type Test Method and Remarks LACAFL : Including self-generated heat LHL : Including self-generated heat 2. Storage temperature Range LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type 4085 3. Rated current LA Type CAL45 Type LHL Within the specified tolerance FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : The maximum DC value having inductance within 10% and temperature incease within 40 (LA:20) by the application of DC bias. LA, CA LHL : The maximum DC value having inductance decrease within 10% (LHLC08, LHLC10within 30%) and temperature increase within the following specified temperature by the application of DC bias. Reference temperature : 25 (LHL08, LHL10, LHL13) : 30 (LHL16, LHLP) : 40 (LHLC08, LHLC10) FB : No disconnection or appearance abnormality by continuous current application for 30 min. Change after the application shall be within 20% of the initial value. This is not guaranteed for electrial characteristics during current application. FL : The maximum DC value having temperature rise within specified value. 4. Impedance LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks FB : Measuring equipment Measuring frequency FL06BT : Measuring equipment Measuring frequency Within the specified tolerance Refer to individual specification : : : : Impedance analyzer (HP4191A) or its equivalent Specified frequency 4291A (HP) or its equivalent Specified frequency 5. Inductance LA Type CAL45 Type Within the specified tolerance LHL FBA/FBR Within the specified tolerance FL05 Type FL06BT Type Test Method and Remarks : Measuring equipment : LCR meter (HP4285A + HP42851A or its equivalent) LA, CA Measuring frequency : Specified frequency LHL : Measuring equipment : LCR meter (HP4285AHP42851A or its equivalent) LCR meter (HP4263A) or its equivalent (at 1KHz) Measuring frequency : Specified frequency FL05R : Measuring equipment : HP4262A or its equivalent Measuring frequency : 1kHz 6. Q LA Type Within the specified tolerance CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA : Measuring equipment : LCR meter (HP4285A + HP42851A or its equivalent) Measuring frequency : Specified frequency LHL (except LHLP) : Measuring equipment : LCR meter (HP4285AHP42851A or its equivalent) LCR meter (HP4263A) or its equivalent (at 1kHz) Measuring frequency : Specified frequency This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP1 1 le0104fi01_reli_e-01 RELIABILITY DATA 7. DC Resisitance LA Type CAL45 Type LHL Within the specified tolerance FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA, CA : Measuring equipment : low ohmmeter (A&D AD5812 or its equivalent) LHLFBFL : Measuring equipment : DC ohmmeter 8. Self resonance frequency LA Type Within the specified tolerance CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA : Measuring equipment : Network analyzer (Anritsu MS620J or its equivalent) LHL (except LHLP) : Measuring equipment : (HP4191A, 4192A) its equivalent 9. Temperature characteristic LA Type L/L : Within 5% CAL45 Type L/L : Within 7% (except LHLP16 : Within 20%) LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA : Change of maximum inductance deviation in step 1 to 5 Step 1 2 3 4 5 Temperature () 20 25 (Minimum operating temperature) 20 (Standard temperature) 85 (Maximum operating temperature) 20 LHL : Change of maximum inductance deviation in step 1 to 5 Temperature at step 1 : 20 Temperature at step 2 : Minimum operating temperature Temperature at step 3 : 20 (Standard temperature) Temperature at step 4 : Maximum operating temperature Temperature at step 5 : 20 10. Terminal strength : tensile force LA Type CAL45 Type No abnormality such as cut lead, or looseness. LHL FBA/FBR No abnormality such as cut lead, or looseness. FL05 Type No abnormality such as cut lead, or looseness. FL06BT Type Test Method and Remarks LA : Apply the stated tensile force progressively in the direction to draw terminal. force (N) 25 CA duration (s) 5 : Apply the stated tensile force progressively in the direction to draw terminal. force (N) 10 duration (s) 10 LHL : Apply the stated tensile force progressively in the direction to draw terminal. Nominal wire diameter tensile d (mm) force (N) duration (s) 0.3d0.5 5 0.5d0.8 10 305 0.8d1.2 25 FBA/FBR : A bead shall be fixed and static loaded 201N (2.00.1 kgf) in axial direction of lead wire in 101 seconds. FL05R : Fix the component in the direction to draw terminal,and gradually apply the tensile force of 4.9N. 11. Over current LA Type CAL45 Type LHL No emission of smoke no firing. There shall be no scorch or short of wire. LHLC08,LHLC10 : There shall be no firing. FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LHL/LACAL45 Type Measuring current Duration Number of measuring : Rated currentx2 : 5 min. : one time This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli_e-01 1 le0104fi01_reli-RP2 RELIABILITY DATA 12. Terminal strength : bending LA Type CAL45 Type No abnormality such as cut lead, or looseness. LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA, CA : Suspend a mass at the end the terminal, incline the body though angel of 90 and return it to initial position. This operation is done over a period of 2-3 sec. Then second bend in the opposite direction shall be made. Number of bends : Two times. Nominal wire diameter tensile d (mm) 0.5d0.8 Bending force (N) 5 Mass reference weight (kg) 0.50 LHFB : Suspend a mass at the end the terminal, incline the body though angel of 90 and return it to initial position. This operation is done over a period of 2-3 sec. Then second bend in the opposite direction shall be made. Number of bends : Two times. Nominal wire diameter tensile Bending force Mass reference weight d (mm) (N) (kg) 0.3d0.5 2.5 0.25 0.5d0.8 5 0.5 0.8d1.2 10 1.0 13. Insulation resisitance : between the terminals and body LA Type CAL45 Type 100M min. LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LHL : Applied voltage : 500 VDC Duration : 60 sec. 14. Insulation resistance : between terminals and core LA Type CAL45 Type LHL FBA/FBR 1M min. (Other than materail code MA) FL05 Type FL06BT Type Test Method and Remarks FBAFBR : Applied voltage : 100 VDC Duration : 605 sec. 15. Withstanding : between the terminals and body LA Type CAL45 Type No abnormality such as insulation damage LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LHL : Accoding to JIS C5102. 7. 1. 3 (C) Metal global method Applied voltage : 500 VDC Duration : 60 sec. 16. DC bias characteristic LA Type L/L : Within 10% CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA, CA : Measure inductance with appliation of rated current using LCR meter to compare it with the initial value. 17. Body strength LA Type No abnormality as damage. CAL45 Type LHL FBA/FBR No abnormality such as cracks on body. FL05 Type FL06BT Type Test Method and Remarks LA : Applied force : 30N Duration : 10 sec. Speed : Shall attain to specified force in 2 sec. CAL45 : Applied force : 50N : 10 sec. Duration Speed : Shall attain to specified force in 2 sec. FBA : Applied force : 503N : 301 sec. Duration This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP3 1 le0104fi01_reli_e-01 RELIABILITY DATA 18. Resisitance to vibration LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Directions LA, CA Frequency range Amplitude Mounting method Recovery : : : : : 2 hrs each in X, Y and Z directions total : 6hrs. 10 to 55 to 10Hz (1min.) 1.5mm Soldering onto printed board. At least 1hr of recovery under the standard condition after the test, followed by the measurement within 2hrs. LHLFB Directions Frequency range Amplitude Mounting method : : : : 2 hrs each in X, Y and Z directions total : 6hrs. 10 to 55 to 10Hz (1min.) 1.5mm (But don't exceed acceleration 196m/s2 (two power)) Soldering onto printed board. L/L : Within 5%Q : 30min L/L : Within 5% L/L : Within 5% Q change : Within 30% (LHLP : only L/L) Appearance : No abnomality Impedance change : Within 20% Appearance : No abnomality 19. Resistance to shock LA Type No significant abnormality in appearance CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Drop test LA, CA Impact material : concrete or vinyl tile Height : 1m Total number of drops : 10 times 20. Solderability LA Type At least 75 of terminal electrode is covered by new solder. CAL45 Type LHL At least 75 of terminal electrode is covered by new solder. FBA/FBR At least 90 of terminal electrode is covered by new solder. FL05 Type At least 75 of terminal electrode is covered by new solder. FL06BT Type Test Method and Remarks : Solder temperature : 2305 LA, CA Duration : 20.5 sec. LHL : Solder temperature : 2355 : 20.5 sec. Duration Immersion depth : Up to 1.5mm from bottom of case. FB : Solder temperature : 2305 : 31 sec. Duration Immersion depth : Up to 1.5mm from terminal root. FL05R : Solder temperature : 2305 : 20.5 sec. Duration Immersion depth : Up to 2 to 2.5mm from terminal root. FL06BT : Solder temperature : 2305 : 31 sec. Duration Immersion depth : Up to 0.5 to 1.0mm from terminal root. 21. Resisitance to soldering heat LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Solder temperature LA, CA Duration Immersed conditions Recovery LHL : Solder bath method Manual soldering Caution Recovery FB : Solder bath method Recovery FL : Solder condition Immersion depth Recovery No significant abnormality in appearance L/L : Within 5% No significant abnormality in appearance No significant abnormality in appearance Refer to individual specification No significant abnormality in appearance : : : : Inductance change : Within 5% Impedance change : Within 20% Q change : Within 30%(LHLP : only L/L) Impedance change : Within 20% (CA) 2705, (LA) 2605 50.5 sec. One time Inserted into substrate with t=1.6mm At least 1hr of recovery under the standard condition after the test, followed by the measurement within 2hrs. : Solder temperature : 2605 Duration : 101 sec. Up to 1.5mm from bottom of case. : Solder temperature : 35010 (At the tip of soldering iron) Duration : 51 sec. Up to 1.5mm from bottom of case. : No excessive pressing shall be applied to terminald. : 4 to 24hrs of recovery under the standard condition after the test. : Condition 1 : Solder temperature : 2605 Duration : 101 sec. Immersion depth : Up to 1.5mm from terminal root. Condition 2 : Solder temperature : 3505 Duration : 31 sec. Immersion depth : Up to 1.5mm from terminal root. : 3hrs of recovery under the standard condition after the test. : 2605 101 sec. : Up to 0.5 to 1.0mm from terminal root. : 3hrs of recovery under the standard condition after the test. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli_e-01 1 le0104fi01_reli-RP4 RELIABILITY DATA 22. Resisitance to solvent LA Type Please avoid the ultrasonic cleaning of this product. CAL45 Type LHL Impedance change : Within 20% FBA/FBR No significant abnormality in appearance FL05 Type FL06BT Type Test Method and Remarks FB : Solvent temperature : 2025 Duration : 305 sec. Solvent type : Acetone, trichloroethylene Recovery : 3hrs of recovery under the standard condition after the test. 23. Thermal shock LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Conditions for 1cycle LA, CA L/L : Within 10%Q : 30min L/L : Within 10% Appearance : No abnormality Appearance : No abnormality Refer to individual specification Appearance : No abnormality Step Temperature () 1 250 3 303 2 Room temperature Within 3 Inductance change : Within 10% Impedance change : Within 20% Q change : Within 30% (LHLPonly L/L) Impedance change : Within 20% Duration (min.) 3 852 0 303 4 Room temperature Within 3 Number of cycles : 5 cycles Recovery : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs. LHLFB : Accoding to JIS C0025 Conditions for 1 cycle Step Temperature () 1 Minimum operating temperature0 3 2 Room temperature 3 Minimum operating temperature2 0 4 Room temperature Number of cycles : : Recovery : : FL Duration (min.) 303 Within 3 303 Within 3 10 cyclesLHL 5 cycles (FBA, FBR) 4 to 24hrs of recovery under the standard condition after the removal from the test chamber.LHL 3hrs of recovery under the standard condition after the removal from the test chamber. (FBA, FBR) : Accoding to JIS C0025 Conditions for 1 cycle Step Temperature () 1 250 3 Duration (min.) 303 2 Room temperature Within 3 3 852 0 303 4 Room temperature Within 3 Number of cycles : 10 cycles Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. 24. Damp heat LA Type L/L : Within 10%Q : 30min CAL45 Type L/L : Within 10% LHL Impedance changeWithin 20% FBA/FBR AppearanceNo abnormality FL05 Type FL06BT Type Test Method and Remarks LA, CA : Temperature : 402 Humidity : 9095%RH Duration : 1000 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. FB : Temperature Humidity Duration Recovery : : : : 602 9095%RH 1000 hrs 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP5 1 le0104fi01_reli_e-01 RELIABILITY DATA 25. Loading under damp heat LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Temperature : LA, CA Humidity : Duration : Applied current : Recovery : L/L : Within 10%Q : 30min L/L : Within 10% Imductance change : Within 10% Appearance : No abnormality Refer to individual specification Appearance : No abnormality Q change : Within 30% (LHLP : only L/L) Impedance change : Within 20% 402 9095%RH 1000 hrs Rated current At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. LHL : Temperature Humidity Duration Applied current Recovery : : : : : 402 9095%RH 100024 hrs Rated current 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. FL : : : : : 603 9095%RH 500 (12, 0) hrs Rated current 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. : Temperature Humidity Duration Applied current Recovery 26. Loading at high temperature LA Type L/L : Within 10%Q : 30min CAL45 Type L/L : Within 10% LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Temperature : 852 LA, CA Duration : 1000 hrs Applied current : Rated current Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. 27. Low temperature life test LA Type L/L : Within 10%Q : 30min CAL45 Type L/L : Within 10% Inductance change : Within 10% Q change : Within 30% (LHLP : only L/L) LHL Appearance : No abnormality FBA/FBR Refer to individual specification FL05 Type Impedance change : Within 20% FL06BT Type Appearance : No abnormality Test Method and Remarks : Temperature : 252 LA, CA Duration : 1000 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. LHL : Temperature : 403 Duration : 100024 hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. FL : Temperature : 403 Duration : 500 (12, 0) hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. 28. High temperature life test LA Type CAL45 Type Inductance change : Within 10% Q change : Within 30% (LHLP : only L/L) Appearance : No abnormality LHL FBA/FBR Refer to individual specification FL05 Type Impedance change : Within 20% FL06BT Type Appearance : No abnormality Test Method and Remarks LHL : Temperature : 1053 Duration : 100024 hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. FL : Temperature : 853 Duration : 500 (12, 0) hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli_e-01 1 le0104fi01_reli-RP6 PRECAUTIONS CAL Type, LH Type, FB Type, FL Type, LA Type 1. Circuit Design Operating environment 1. The products described in this specification are intended for use in general electronic equipment,(office supply equipment, telecommunications systems, measuring equipment, and household equipment). They are not intended for use in mission-critical equipment or systems requiring special quality and high Precautions reliability (traffic systems, safety equipment, aerospace systems, nuclear control systems and medical equipment including life-support systems,) where product failure might result in loss of life, injury or damage. For such uses, contact TAIYO YUDEN Sales Department in advance. 2. PCB Design Design 1. Please design insertion pitches of a base in the pitches that fitted a terminal interval. Technical Design 1. When Inductors are mounted onto a PC board, hole dimensions on the board should match the lead pitch of the component, if not, it will cause breakage of considerations the terminals or cracking of terminal roots covered with resin as excess stress travels through the terminal legs. Precautions 3. Considerations for automatic placement Adjustment of mounting machine 1. Excessive impact load should not be imposed on the products when mounting onto the PC boards. Precautions 2. Mounting and soldering conditions should be checked beforehand. Technical Adjustment of mounting machine consider1. When installing products, care should be taken not to apply distortion stress as it may deform the products. ations 4. Soldering Wave soldering 1. Please refer to the specifications in the catalog for a wave soldering. 2. Do not immerse the entire Inductors in the flux during the soldering operation. Lead free soldering 1. When using products with lead free soldering, we request to use them after confirming of adhesion, temperature of resistance to soldering heat, soldering etc sufficiently. Recommended conditions for using a soldering iron: Precautions Put the soldering iron on the land-pattern. Soldering iron's temperature - Below 350 Duration - 3 seconds or less The soldering iron should not directly touch the inductor. Reflow soldering 1. As for reflow soldering, please contact our sales staff. Technical Lead free soldering 1. If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently degrade the reliability of considerations the products. 5. Cleaning Precautions Technical considerations Cleaning conditions 1. CAL type, LH type, LA Type Please do not do cleaning by a supersonic wave. Cleaning conditions 1. CAL type, LH type, LA Type If washing by supersonic waves, supersonic waves may deform products. 6. Handling Handling 1. Keep the inductors away from all magnets and magnetic objects. Mechanical considerations 1. Please do not give the inductors any excessive mechanical shocks. 2. LH type Precautions If inductors are dropped onto the floor or a hard surface they should not be used. Packing 1. Please do not give the inductors any excessive mechanical shocks. In loading, please pay attention to handling indication mentioned in a packing box (a loading direction / number of maximum loading / fragile item). Handling 1. There is a case that a characteristic varies with magnetic influence. Mechanical considerations Technical 1. There is a case to be damaged by a mechanical shock. consider2. LH type ations There is a case to be broken by a fall. Packing 1. There is a case that a lead route turns by a fall or an excessive shock. 7. Storage conditions Storage 1. To maintain the solderability of terminal electrodes and to keep the packing material in good condition, temperature and humidity in the storage area should be controlled. Recommended conditions Ambient temperature 040 Precautions Humidity Below 70% RH The ambient temperature must be kept below 30. Even under ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, inductors should be used within one year from the time of delivery. In case of storage over 6 months, solderability shall be checked before actual usage. Technical Storage 1. Under a high temperature and humidity environment, problems such as reduced solderability caused by oxidation of terminal electrodes and deterioration of considerations taping/packaging materials may take place. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP7 1 le0104fi01_reli_e-01 COMMON MODE CHOKE COIL (SMD) FOR HIGH-SPEED DIFFERENTIAL SIGNAL REFLOW FEATURES APPLICATIONS CM01 Series is Wire-wound Structured Type Commom Mode Choke Coil which provides highly effective noise suppression characteristics without distorting the wave pattern of High-speed Differential Signal interface. Radiated noise suppression in the High-speed Diffrential Signal interfaces [HDMI, Serial-ATA, IEEE1394, LVDS, and USB2.0] of LCD-TV, Blu-ray players, and PCs. Developed 1210 case-size by utilizing our wire-wound technologies. This small and wire-wound structured product has little transmission loss and keeps high common impedance up to GHz range. CM01S600 : Suitable characteristics for super high speed differential signal such as USB3.0 and so on. Cutoff frequency is 10GHz. Countermeasure for degradation of receiver sensitivity caused by high frequency noise from high-speed differential signal of Cellular phones, Data Cards and Smartphones. Common mode noise suppression raised from the power line and audio signal in a small device. CM01H900 : Suitable characteristics for high speed differential signal such as HDMI, DVI, Displayport and so on. Cut-off frequency is 8GHz. CM01U900 : Suitable characteristics for differential signal such as USB2.0, LVDS, LAN and so on. Cut-off frequency is 3GHz. High rated current of this product makes it possible to replace 2012 size product for this product. CM01U161 : Suitable characteristics for differential signal such as USB2.0, LVDS, LAN and so on. Cut-off frequency is 3GHz. High common impedance of this product works effectively on noise suppression. ORDERING CODE C M 0 1 9 Type Common mode choke coil CM H 0 0 External Dimensions (LxW) 01 1.2x1.0mm T Product classification code S USB3.0 correspondence H HDMI/Displayport correspondence U USB2.0/LAN correspondence 600 900 161 Impedance 60 typical at 100MHz 90 typical at 100MHz 160 typical at 100MHz T Packaging Taping EXTERNAL DIMENSIONS/MINIMUM QUANTITY CM01TYPE 1.20.2 Type 1.00.2 CM01 2 Linestype Minimum Quantity (pcs.) Embossed tape 3000 0.350.1 0.350.1 0.03min. 0.9 max. EQUIVALENT CIRCUIT There is no directionality. 0.300.1 Unitmminch 0.350.1 PART NUMBERS CM01 TYPE Ordering EHS No. of Lines CM01S600T CM01H900T CM01U900T CM01U161T RoHs RoHS RoHs RoHs 2 2 2 2 Common Impedance [] (at 100MHz) 60typ. 90typ. 90typ. 160typ. 43min 65min. 65min 120min DC resistance [] 0.4max 0.5max. 0.3max 0.6max Rated current [mA] 300max 280max. 400max 260max Rated voltage V(D.C.) 20max 20max. 20max 20max dielectric resistance M 100min 100min. 100min 100min Cut off frequency GHz 10.0typ. 8.0typ. 3.0typ. 3.0typ. Characteristic impedance 90typ. 100typ. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 138 1 coil01_e-01 ELECTRICAL CHARACTERISTICS Impedance characteristics 1000 CM01 S600 Type 1000 CM01 H900 Type CM01 U900 Type 1000 1000 CM01 U161 Type Common Impedance Common Impedance 10 Differential Impedance 1 10 100 1000 Frequency MHz 100 Impedance 10 Common Impedance 100 Impedance Impedance Impedance Common Impedance 100 10 Differential Impedance 1 10 10000 100 1000 Frequency MHz 100 10 Differential Impedance 1 10 10000 100 1000 Frequency MHz Differential Impedance 1 10 10000 100 1000 Frequency MHz 10000 Transmission characteristic CM01 U900 Type CM01 H900 Type CM01 U161 Type -2 -2 -2 -2 -4 -4 -4 -4 -6 -8 -8 -10 10 -6 100 1000 Frequency MHz 10000 -10 10 sdd21 0 sdd21 0 sdd21 0 -6 -8 100 1000 Frequency MHz 10000 -6 -8 -10 10 100 1000 Frequency MHz 10000 -10 10 100 1000 Frequency MHz 10000 FERRITE PRODUCTS sdd21 CM01 S600 Type 0 This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. coil01_e-01 1 139 COMMON MODE CHOKE COILS (FOR DC AND SIGNAL LINES) SMD TYPE REFLOW FEATURES APPLICATIONS Available in embossed tape and reel. Immunity against undesirable external line radiation fields and broadcast waves generated by multifunction telephone sets, PBXs, and facsimile machines. Highly coupled coil construction ideal for common mode noise attenuation. Preventive measure against DC line noise in electronic equipment. Suppresses radiated emissions from secondary power supplies and signal lines on AC adapters, battery chargers, and digital equipment. OPERATING TEMP. Excellent for reducing radiated noise in DVC (digital video cameras) and DSC (digital still cameras) 25105Including self-generated heat Offers high speed differential mode noise attenuation in USB and IEEE1394 connectors in personal computers, printers, scanners and other computer peripherals. ORDERING CODE C M 0 4 Type CM BU R C 1 Dimensions of Core (mm) 04 3.5 05 5.0 Common mode choke coils 0 Shape RC MC Surface mount type T Product classification code 0110 Packaging Taped products T Internal code Standard Products Blank space EXTERNAL DIMENSIONS/MINIMUM QUANTITY CM04RC2 Linestype 0.1min 0.004min 0.25 0.010 9.00.5 0.3540.020 6.00.2 0.2360.008 0.25 0.010 2.540.25 0.5 0.1000.010 0.020 9.80.2 0.3540.008 0.1min 0.004min 5.30.2 0.2080.008 2.50.3 0.1000.012 0.020 0.1min 0.3 0.012 0.5 1.270.25 0.0500.010 The values without tolerance are for reference only. 4.10.3 0.1610.012 0.1min 0.004min 0.2 0.008 6.00.2 0.0240.008 Minimum Quantity (pcs.) Embossed tape 1000 1.3 0.051 0.004min 7.40.2 0.2910.008 0.6 0.024 CM04RC4 Linestype Minimum Quantity (pcs.) Embossed tape 2500 0.020 4.30.3 0.1690.012 0.5 0.020 0.1min 0.004min 0.25 0.010 2.540.25 0.1000.010 2.540.25 0.1000.010 5.20.2 0.2050.008 0.5 1.3 0.051 1.3 0.05 CM04RC3 LinestypeThin Minimum Quantity (pcs.) Embossed tape 1000 9.00.5 0.3540.020 0.020 5.00.3 0.1960.012 CM04RC3 Linestype 6.00.2 0.2360.008 0.5 1.50.2 0.0590.008 9.00.5 0.3540.020 5.00.3 0.1970.012 2.70.2 0.1060.008 0.5 0.020 0.1min 0.004min 0.2 0.008 3.00.2 0.1180.008 2.70.2 0.1060.008 0.5 0.020 0.5 0.020 Minimum Quantity (pcs.) Embossed tape 1500 4.40.3 0.1730.012 6.00.2 0.2360.008 5.30.5 0.2090.020 Minimum Quantity (pcs.) Embossed tape 2500 9.00.5 0.3540.020 BU05MC3 Linestype Minimum Quantity (pcs.) Embossed tape 2500 2.60.2 0.1020.008 5.30.5 0.2090.020 2.60.2 0.1020.008 BU05MC2 Linestype Unit : mm (inch) PART NUMBERS CM04RC Type Ordering code CM04RC01T CM04RC04T CM04RC07T CM04RC09T CM04RC10T CM04RC02T CM04RC08T ( THIN) CM04RC05T EHS (Environmental Hazardous Substances) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS No. of Lines 2 3 4 Impedance [] (typical) 800 900 500 270 100 1000 1000 800 (at 100MHz) (at 20MHz) (at 160MHz) (at 200MHz) (at 200MHz) (at 100MHz) (at 200MHz) (at 100MHz) DC resistance [] (max.) Rated current [A] (max.) Rated voltage [V] (D.C.) Insulation resistance [M] (min.) 0.06 0.1 0.06 0.03 0.02 0.18 0.2 0.2 1.5 1.3 2.5 3.0 4.0 0.5 0.5 0.5 50 100 DC resistance [] (max.) Rated current [A] (max.) Rated voltage [V] (D.C.) Insulation resistance [M] (min.) 0.12 0.11 1 0.5 50 100 BU05MC Type Ordering code BU05MC01T BU05MC08T EHS (Environmental Hazardous Substances) RoHS RoHS No. of Lines 2 3 Impedance [] (typical) 1000 (at 60MHz) 700 (at 60MHz) This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 140 1 coil02_e-01 ELECTRICAL CHARACTERISTICS Impedance -vs- Frequency characteristics Measured by HP4291A RC04 RC07 01 RC RC09 0 RC1 Normal mode FERRITE PRODUCTS Common mode This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. coil02_e-01 1 141 PACKAGING Minimum Quantity Taping dimensions Type CM01 2 Linestype CM04RC2 Linestype CM04RC3 Linestype CM04RC3 Linestype (Thin) CM04RC4 Linestype BU05MC2 Linestype BU05MC3 Linestype Embossed tape (CM01 type) Minimum Quantity (pcs.) Embossed tape 3000 1500 1000 2500 1000 2500 2500 Unit : mm (inch) Tape Material Embossed tape (CM04RC type) 8mm pitch (0.31 inches pitch) Unit : mm (inch) Embossed tape (CM04RC type) 12mm pitch (0.472 inches pitch) Leader and Blank Portion Unit : mm (inch) Embossed tape (BU05MC type) Type CM01 CM04RC BU05MC Leader Blank portions (Leader side) Blank portions (Chip cavity side) 200400 (7.8715.75) 160200 (6.307.87) 160 (6.30) or more 150 (5.89) 150 (5.89) 80 (3.14) 80 (3.14) 80 (3.14) 80 (3.14) Unit : mm (inch) Unit : mm (inch) Reel size Type Lines CM01 2 2 3 3 (THIN) 4 2 3 CM04RC BU05MC 4.00.1 8.00.1 12.00.1 8.00.1 12.00.1 Chip cavity A B 1.160.1 1.410.1 5.70.1 9.650.1 9.80.1 7.70.1 5.70.1 9.80.1 10.30.1 10.30.1 tape thickness K T 0.980.1 0.3max. 5.2max 0.40.05 5.0max 0.380.05 3.1max 0.40.05 5.0max 0.30.05 8.00.1 5.351.5 3.20.1 Insertion pitch 5.70.2 0.40.05 Unit : mm (inch) Top Tape Strength Type A B C CM01 601/0 (2.360.039/0) 1800/3 (7.090/0.118) 10.01.5 (0.3940.059) CM04RC 1001 (3.940.039) 3302 (12.990.079) 181.5 (0.7090.059) BU05MC 801 (3.150.039) 3302 (12.990.079) 13.51 (0.530.039) Unit : mm (inch) CM01 The top tape requires a peel-off force of 0.1 to 1.0N in the direction of the arrow as illutrated above. CM04RC, BU05MC The top tape requires a peel-off force of 0.1 to 0.7N in the direction of the arrow as illutrated above. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. coil0102_pack_e-01 1 coil0102_pack-P1 COMMON MODE CHOKE COILS (FOR DC AND SIGNAL LINES) LEADED TYPE WAVE FEATURES APPLICATIONS Highly reliable, compact and lightweight TLF Type : Countermeasure for noise in the low-frequency (AM) broad-casting band. Shields against radiated emissions in the broadcasting frequency for multi-functional telephone sets. PBXs, faxes, etc. Easily inserted into the PCB CM/BU Type : Countermeasure for noise in the high-frequency (MHz) band OPERATING TEMP. TLF Type 25105 CM Type 25105 Including self-generated heat ORDERING CODE TLF Type T L F 9 TLF Type Line filter U B H Dimensions of core 9 9mm Blank space 3 Shape U core, vertically split wound U core, horizontally split wound UB UBH 2 W 0 Nominal inductance (H) example 302 203 Inductance tolerance (%) 100 10 W 3000 20000 Internal code Standard product Blank space Blank space CM-BU Type C M 0 5 Type CM Common mode choke coile BU R A Core dimensionsmm 05 4.8 08 8.0 12 12.0 6 0 RA RB Shape Double-wire lead Product classification code 0120 Internal code Standard product Blank space Pin type with base EXTERNAL DIMENSIONS/MINIMUM QUANTITY TLF9UB Type TLF9UB H Type CMRA Type / BU08RA Type Type CM05RA06 CM08RA CM12RA02 BU08RA Minimum Quantity (pcs.) Box 500 CM05RB (2Lines Type) Minimum Quantity (pcs.) Box Bulk 1000 Minimum Quantity (pcs.) Box 500 CM08RB (2Lines) Type Type CM05 CM08,BU08 CM12 W (max.) 6.5 (0.256) 11.0 (0.433) 15.5 (0.610) Minimum Quantity (pcs.) Box Bulk 500 250 100 200 T (max.) 3.0 (0.118) 6.0, 7.0 (0.024, 0.276) 7.0 (0.276) CM08RB (4Lines) Type Minimum Quantity (pcs.) Box Bulk 500 Minimum Quantity (pcs.) Box Bulk 500 Unit : mm (inch) This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 142 1 coil03_e-01 PART NUMBERS EHS (Environmental Hazardous No. of lines Substances) RoHS RoHS RoHS 2 RoHS RoHS RoHS Ordering code TLF9UBH 302W TLF9UB 302W TLF9UBH 802W TLF9UB 802W TLF9UBH 203W TLF9UB 203W EHS (Environmental Hazardous No.of lines Substances) Ordering code CM05RA BU08RA CM08RA CM05RB CM08RB RoHS RoHS RoHS RoHS RoHS RoHS RoHS 2 RoHS RoHS RoHS RoHS RoHS RoHS 4 DC resistance [] (max.) Rated current [A] (max.) 3000 1.5 0.4 8000 3.0 0.3 20000 6.5 0.18 Inductance [H] [at 1kHz] 0.7 min. 0.71.3 1.192.21 15.0 min. 6.0 min. 10.0 min. 7.0 min. 15.0 min. 40.0 min. 15.0 min. 110.0 min. 6.0 min. 15.0 min. Impedance [] (typical) 700 1000 1200 2000 500 2000 700 1400 2500 2000 2000 450 1000 (at 200MHz) (at 250MHz) (at 200MHz) (at 80MHz) (at 200MHz) (at 80MHz) (at 70MHz) (at 100MHz) (at 30MHz) (at 50MHz) (at 70MHz) (at 100MHz) (at 50MHz) Rated voltage [V] D.C. Insulation resistance [M] (min.) Impedance [K] (Reference values) 20 (at 1MHz) 50 40 (at 700kHz) 100 150 (at 500kHz) DC resistance [] (max.) Rated current [A] (max.) Rated voltage [V] D.C. Insulation resistance [M] (min.) 0.050 0.013 0.011 0.040 0.020 0.040 0.050 0.060 0.040 0.040 0.040 0.020 0.050 1.5 4.0 3.0 2.4 5.5 3.0 2.0 1.5 2.0 2.4 3.0 4.0 2.0 50 100 20 3 ELECTRICAL CHARACTERISTICS FERRITE PRODUCTS CM12RA 06 11 16 17 20 02 01 03 01 02 04 05 03 Inductance %] [H] [ 100 10 2 80 2 30 Measuring conditions Equipment : HP4291A HP4192A Vosc : 0.5V (CM/BU type) Vosc : 0.35V (TLF type) Measuring circuit : To impedance analyzer This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. coil03_e-01 1 143 COMMON MODE CHOKE COILS (FOR AC LINES) LEADED TYPE WAVE FEATURES APPLICATIONS TLF 9UA (H) Type : Small-sized configuration As a preventive measure against noise terminal voltage or power supply noise in TV or VTR units, SW power supplies, NC machines, computer systems, peripheral units, measuring instruments, and controllers. TLF14CB (H) Type : Ordinary configuration TLF 9UA (H) Type : low-current applications TLF14CB (H) Type : equipment with several tens of watts of input power OPERATING TEMP. TLF9U Type TLF14CB Type 25105 25105 Including self-generated heat ORDERING CODE T L F 9 TLF Type Line filter Core dimensionsmm 9 9 14 14 Blank space UA UAH CB CBH U A H 1 Nominal Inductance (H) example 102 103 1000 10000 0 2 W 0 R 8 Inductance tolerance (%) Nominal Values or higher W 100 10 Blank space Shape U core, vertical type U core, horizontal type Square type core vertically split wound Square type core horizontally split wound Rated current (A) R54 0.54 0R8 0.8 Internal code Standard Product Blank space R=decimal point Product classification code Standard Blank space Blank space EXTERNAL DIMENSIONS/MINIMUM QUANTITY TLF14CB Type TLF14CBH Type Type TLF9UA TLF14CB TLF9UA Type Minimum Quantity (pcs.) Box 500 500 TLF9UA H Type Unit : mm (inch) This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 144 1 coil04_e-01 PART NUMBERS Type TLF9UA TLF9UAH TLF14CBH EHS (Environmental Inductance Hazardous [mH] Substances) TLF 9UA 102 W 0R8 TLF 9UA 202 W R54 TLF 9UA 302 W R42 TLF 9UA 502 W R32 TLF 9UA 802 W R25 TLF 9UA 103 W R23 TLF 9UA H 102 W 0R8 TLF 9UA H 202 W R54 TLF 9UA H 302 W R42 TLF 9UA H 502 W R32 TLF 9UA H 802 W R25 TLF 9UA H 103 W R23 TLF 14CB 102 1R5 TLF 14CB 222 1R2 TLF 14CB 332 1R0 TLF 14CB 472 1R0 TLF 14CB 562 0R8 TLF 14CB 682 0R8 TLF 14CB 103 0R7 TLF 14CB 223 0R4 TLF 14CB 333 0R3 TLF 14CB 473 0R2 TLF 14CB 563 0R2 TLF 14CB 683 0R2 TLF 14CB H 102 1R5 TLF 14CB H 222 1R2 TLF 14CB H 332 1R0 TLF 14CB H 472 1R0 TLF 14CB H 562 0R8 TLF 14CB H 682 0R8 TLF 14CB H 103 0R7 TLF 14CB H 223 0R4 TLF 14CB H 333 0R3 TLF 14CB H 473 0R2 TLF 14CB H 563 0R2 TLF 14CB H 683 0R2 RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 1 2 3 5 8 10 1 2 3 5 8 10 1.0 2.2 3.3 4.7 5.6 6.8 10 22 33 47 56 68 1.0 2.2 3.3 4.7 5.6 6.8 10 22 33 47 56 68 Inductance Tolerance DC resistance [] (max.) 100/10 100/10 100/10 100/10 100/10 100/10 100/10 100/10 100/10 100/10 100/10 100/10 min min min min min min min min min min min min min min min min min min min min min min min min 0.5 1.0 1.5 2.5 4.0 4.5 0.5 1.0 1.5 2.5 4.0 4.5 0.1 0.18 0.32 0.38 0.42 0.6 0.85 1.7 2.7 3.6 5 6.5 0.1 0.18 0.32 0.38 0.42 0.6 0.85 1.7 2.7 3.6 5 6.5 Rated current Rated voltage [A] (max.) [V]max. 0.80 0.54 0.42 0.32 0.25 0.23 0.80 0.54 0.42 0.32 0.25 0.23 1.5 1.2 1.0 1.0 0.8 0.8 0.7 0.4 0.3 0.2 0.2 0.2 1.5 1.2 1.0 1.0 0.8 0.8 0.7 0.4 0.3 0.2 0.2 0.2 AC250 Withstanding voltage V min. [1 minute] Applicable frequency [MHz] Reference Value AC2000 0.110 FERRITE PRODUCTS TLF14CB Ordering code ELECTRICAL CHARACTERISTICS Impedance-Frequency characteristic TLF9UA/TLF9UAH Type Test conditions Equipment : HP-4192A TLF14CB/TLF14CBH Type Vosc-0.35V Test circuit : To impedance analyzer This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. coil04_e-01 1 145 PACKAGING Minimum Quantity CM/BU Type Type CM05RA06 CM05RB CM08RA CM08RB CM12RA02 BU08RA Minimum Quantity (pcs.) Box Bulk -- 500 1000 -- -- 250 500 -- -- 100 -- 200 TLF Type Type TLF9UA TLF9UB TLF14CB Minimum Quantity (pcs.) Box 500 500 500 This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. coil0304_pack_e-01 1 coil0304_pack-P1 BALUN TRANSFORMERS MB FEATURES APPLICATIONS High stability due to pair wire windings Impedance transformers MC type : pins are molded into the base to create a singular structure Distribution transformers MC WAVE REFLOW This item can be custom designed to meet customer requirements OPERATING TEMP. 25105Including self-generated heat ORDERING CODE B U 0 5 M B BU Type Balun transformer 1 0 Length of component [mm] 05 5.05.3 06 6.0 MB MC Shape pin type Surface-mount type T Packaging Tape & Reel Bulk (Only pin type) Internal code Standard product Blank space Blank space Product classification code example 01 EXTERNAL DIMENSIONS/MINIMUM QUANTITY Pin type MB (BU05MB, BU06MB) Surface-mount type MC (BU05MC) A A Type B B E C C Fig. D D Type BU05MB BU06MB BU05MC A B C D Minimum Quantity (pcs.) Box Taping E 6.0 max. 1.750.2 3.5 5.5 max. 5.5 max. 0.217 max. 0.217 max. 0.236 max. 0.0690.008 0.138 8 max. 8 max. 8 max. 2.250.2 pitch 3.55.0 0.315 max. 0.315 max. 0.315 max. 0.0890.0080.1380.197 5.30.5 5.00.3 2.70.2 1.50.2 pitch 0.2090.0200.1970.012 0.1060.0080.0590.008 200 150 Recommended Land Patterns BU05MC 0.5 0.5 1.6 2500 Unit : mm (inch) 1.6 1 1 1 Unit : mm (inch) ELECTRICAL CHARACTERISTICS The following chart shows typical ranges for operating characteristics. Please specify the following when ordering. loss standing wave ratio (VSWR) operating frequency specified test circuit This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 146 1 trans01_e-01 PACKAGING Minimum Quantity Type BU05MC BU05MB BU06MB Top Tape Strength Box 200 150 Minimum Quantity (pcs.) Taping 2500 The top tape requires a peel-off force of 0.1 to 0.7N in the direction of the arrow as illustrated below. Tape material Taping dimensions Embossed tape 12mm wide (0.472 inches wide) 3.20.1 20.1 0.0790.004 0.1260.004 1.750.1 0.0690.0040.40.05 0.0160.002 5.60.1 0.2200.004 5.50.1 0.2170.004 120.3 0.4720.012 80.1 1.5 +0.1 -0 0.3150.004 40.1 0.059+0.004 -0 0.1570.004 5.20.1 0.2090.004 Unit : mm (inch) Leader and Blank portion Reel size 3302 12.990.079 801 3.150.039 Label 13.51 0.530.039 Unit : mm (inch) This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. trans01_pack_e-01 1 trans01_pack-P1 RELIABILITY DATA 1. Operating Temperature Range CM01 CM04RC BU05MC Test Method and Remarks Including self-generated heat 2. Storage Temperature Range CM01 CM04RC BU05MC Test Method and Remarks 5 to 40 in taped packaging 40105 25105 4085 3. Rated current CM01 CM04RC Within the specified tolerance. BU05MC Test Method and Remarks The maximum DC value having temperature increase within specified temperature,as detailed in individual specification. 4. Impedance CM01 CM04RC Within the specified tolerance. BU05MC Test Method and Remarks Measuring equipment : HP 4291A or its equivalent Measuring frequency : Specified frequency 5. DC Resisitance CM01 CM04RC Within the specified tolerance. BU05MC Test Method and Remarks SMD transformerCommom mode choke coil : Measuring equipment : DC ohm meter 6. Resistance to flexure of substrate CM01 CM04RC BU05MC Test Method and Remarks According to JIS C 0051 Warp Pressing speed Duration CM01 2mm Within the specified tolerance. Refer to individual specification. CM04RCBU05MC 3mm 0.5mm/sec. 51sec. 7. Dielectric resistance : between wires CM01 CM04RC 100M min. BU05MC Test Method and Remarks Applied voltage : Rated voltage Duration : 60 sec. 8. Rated voltage CM01 CM04RC BU05MC Within the specification. 9. Withstanding voltage : between wires CM01 CM04RC No abnormality. BU05MC Test Method and Remarks Applied voltage : Regulation voltage Duration : 60 sec. 10. Resistance to vibration CM01 No abnormality observed in appearance CM04RC Refer to individual specification. BU05MC Test Method and Remarks According to JIS C 0040 Directions : 2 hrs each in X, Y, and Z directions. Total : 6 hrs Frequency range : 10 to 55 to 10 Hz (1 min.) Amplitude : 1.5mm (Shall not exceed acceleration 196m/s2) Mounting method : soldering onto printed board Recovery : At least 2 hrs of recovery under the standard condition after the test,followed by the measurement within 48 hrs. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0102tr01_reli-RP1 1 co0102tr01_reli_e-01 RELIABILITY DATA 11. Solderability CM01 CM04RC BU05MC Test Method and Remarks At least 90% of terminal electrode is covered by new solder. At least 75% of terminal electrode is covered by new solder. 12. Resistance to solder Heat CM01 CM04RC BU05MC Test Method and Remarks Reflow soldering Within the specified tolerance. Refer to individual specification. CM01 : 150 to 180 1 to 2min : 2555 5sec. 2305 3040sec. Number of reflow : Within 2 times Preheating Peak - Manual soldering 13. Thermal shock CM01 CM04RC BU05MC Test Method and Remarks Accoding to JIS C 0025 Conditions of 1 cycle Step 1 2 3 4 CM04RCBU05MC 2355 20.5sec. Up to 0.5mm from terminal root CM01 2455 31sec. - Solder temperature Duration Immersion depth CM04RCBU05MC : 100 to 150 1 to 2min : 230 to 240 within 5sec. More than 200 within 40sec. Number of reflow : Within 2 times Solder temperature : 3505 Duration : 31sec. Recovery : 1 to 2hrs of recovery under the standard condition after the test. Preheating Peak Within the specified tolerance. Refer to individual specification. Temperature () CM01 CM04RCBU05MC 403 253 Room Temp. Room Temp. 852 853 Room Temp. Room Temp. CM01 Time (min) CM04RCBU05MC 303 3 303 3 Number of cycle : CM01 : 100 cycle CM04RCBU05MC : 10 cycle Recovery : Recovery under the standard condition after removal from test chamber. CM01 : Measuring it more than two hours and less than 48 hours. CM04RCBU05MC : Leave during 12 hour. 14. Loading under damp heat CM01 CM04RC BU05MC Test Method and Remarks Within the specified tolerance. Refer to individual specification. CM04RCBU05MC 403 9095RH Rated current 100024hrs CM01 602 Temperature Humidity Applied current Duration Recovery : Recovery under the standard condition after removal from test chamber. CM01 : Measuring it more than two hours and less than 48 hours. CM04RCBU05MC : Leave during 12 hour. 15. High temperature life test CM01 CM04RC BU05MC Test Method and Remarks Temperature Duration Refer to individual specification. CM04RCBU05MC 853 100024hrs Recovery : Recovery under the standard condition after removal from test chamber. CM01 : Measuring it more than two hours and less than 48 hours. CM04RCBU05MC : Leave during 12 hour. 16. Low Temperature life Test CM01 CM04RC BU05MC Test Method and Remarks Temperature Applied current Within the specified tolerance. Refer to individual specification. CM01 CM04RCBU05MC -402 -403 100024hrs Recovery : Recovery under the standard condition after removal from test chamber. CM01 : Measuring it more than two hours and less than 48 hours. CM04RCBU05MC : Leave during 12 hour. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0102tr01_reli_e-01 1 co0102tr01_reli-RP2 RELIABILITY DATA 17. Loading at high temperature life test CM01 Within the specified tolerance. CM04RC BU05MC Test Method and Remarks Temperature Applied current Duration CM01 1052 Rated current 100024hrs Recovery : Recovery under the standard condition after removal from test chamber. CM01 : Measuring it more than two hours and less than 48 hours. CM04RCBU05MC : Leave during 12 hour. Note on standard condition : "standard condition" referred to herein is defined as follows: 5 to 35 of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure. When there are questions concerning measurement results: In order to provide correlation data, the test shall be conducted under condition of 202 of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure. Unless otherwise specified, all the tests are conducted under the "standard condition." This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0102tr01_reli-RP3 1 co0102tr01_reli_e-01 PRECAUTIONS CM04RC, BU05MC, CM01 1. Circuit Design Operating environment 1. The products described in this specification are intended for use in general electronic equipment, (office supply equipment, telecommunications systems, measuring equipment, and household equipment). They are not intended for use in mission-critical equipment or systems requiring special quality and high Precautions reliability (traffic systems, safety equipment, aerospace systems, nuclear control systems and medical equipment including life-support systems,) where product failure might result in loss of life, injury or damage. For such uses, contact TAIYO YUDEN Sales Department in advance. 2. PCB Design Land pattern design 1. Please contact any of our offices for a land pattern, and refer to a recommended land pattern of specifications. Land pattern design CM04RC BU05MC Surface Mounting 0.5 0.5 Mounting and soldering conditions should be checked 1.6 beforehand. Precautions Applicable soldering process to this products is reflow soldering only. Recommended Land Patterns Technical considerations 6.7 0.45 1.4 0.65 1.55 3.2 0.45 1.4 1.6 1 1.8 0.74 1.8 CM01 1 1 0.4 0.3 0.4 1.1 Unit : mm 3. Considerations for automatic placement Adjustment of mounting machine 1. Excessive impact load should not be imposed on the products when mounting onto the PC boards. Precautions 2. Mounting and soldering conditions should be checked beforehand. Technical Adjustment of mounting machine consider1. When installing products, care should be taken not to apply distortion stress as it may deform the products. ations 4. Soldering Reflow soldering 1. Please contact any of our offices for a reflow soldering, and refer to the recommended condition specified. 2. This product is reflow soldering only. 3. Please do not add any stress to a product until it returns in normal temperature after reflow soldering. Lead free soldering 1. When using products with lead free soldering, we request to use them after confirming of adhesion, temperature of resistance to soldering heat, soldering etc sufficiently. Recommended conditions for using a soldering iron Precautions CM04RC, BU05MC Put the soldering iron on the land-pattern. Soldering iron's temperature - Below 350 Duration - 3 seconds or less The soldering iron should not directly touch the inductor. CM01 Please do not conduct an adjustment with a soldering iron because the wire would be broken due to its thinness. Technical Reflow soldering consider1. If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently degrade the reliability of the ations products. 5. Cleaning Precautions Cleaning conditions 1. Please contact any of our offices for a cleaning. 6. Handling Handling 1. Keep the product away from all magnets and magnetic objects. Breakaway PC boards (splitting along perforations) 1. When splitting the PC board after mounting product, care should be taken not to give any stresses of deflection or twisting to the board. 2. Board separation should not be done manually, but by using the appropriate devices. Mechanical considerations 1. Please do not give the product any excessive mechanical shocks. Precautions 2. Please do not add any shock and power to a product in transportation. Pick-up pressure 1. Please do not push to add any pressure to a winding part. Please do not give any shock and push into a ferrite core exposure part. Packing 1. Please avoid accumulation of a packing box as much as possible. Handling 1. There is a case that a characteristic varies with magnetic influence. Breakaway PC boards (splitting along perforations) 1. Planning pattern configurations and the position of products should be carefully performed to minimize stress. Technical Mechanical considerations consider1. There is a case to be damaged by a mechanical shock. ations 2. There is a case to be broken by the handling in transportation. Pick-up pressure 1. Damage and a characteristic can vary with an excessive shock or stress. Packing 1. There is a case that transformation and a product of tape are damaged by accumulation of a packing box. 7. Storage conditions Storage 1. To maintain the solderability of terminal electrodes and to keep the packing material in good condition, temperature and humidity in the storage area should be controlled. Recommended conditions Ambient temperature : 040 Humidity : Below 70% RH Precautions The ambient temperature must be kept below 30. Even under ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, product should be used within one year from the time of delivery. Technical considerations In case of storage over 6 months, solderability shall be checked before actual usage. Storage 1. Under a high temperature and humidity environment, problems such as reduced solderability caused by oxidation of terminal electrodes and deterioration oftaping/packaging materials may take place. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0102tr01_reli-RP4 1 co0102tr01_reli_e-01 RELIABILITY DATA 1. Operating Temperature Range CM-RA/BU-RA Type 25105 CM-RB Type TLF9U : 25105, TLF14CB : 25105 TLF9U, TLF14CB Test method and remarks Including temperature rise due to self-generated heat. 2. Storage temperature range CM-RA/BU-RA Type CM-RB Type TLF9U, TLF14CB 4085 3. Rated current CM-RA/BU-RA Type CM-RB Type Within the specified range TLF9U, TLF14CB Test method and remarks CM : The maximum DC value having temperature increase within specified temperature, as detailed in individual specification. TLF9UA14CB : The maximum AC value having temperature increase within 45 by the application of AC current. TLF9UB : The maximum DC value having temperature increase within 45 by the application of DC current. 4. Inductance CM-RA/BU-RA Type CM-RB Type Within the specified tolerance TLF9U, TLF14CB Test method and remarks CM : Measuring equipment : 4263A (HP) or its equivalent Measuring frequency : 1kHz TLF9UA : Measuring equipment : Impedance analyzer (HP4192A) or its equivalent Measuring frequency : 1kHz Measuring voltage : 0.35Vosc TLF14CB : Measuring equipment : LCR meter 4284A or its equivalent Measuring frequency : 1kHz Measuring voltage : 1.0V 5. DC resistance CM-RA/BU-RA Type CM-RB Type Within the specified tolerance TLF9U, TLF14CB Test method and remarks CMTLF : Measuring equipment : DC ohmmeter 6. Terminal strength tensile force CM-RA/BU-RA Type CM-RB Type No abnormality TLF9U, TLF14CB Test method and remarks CM : Fix the component in the direction to draw terminal and gradually apply tensile force as detailed in indiviual specifications. TLF9U : Apply the stated tensile force gradually in the direction to draw terminal. Nominal wire diameter tensile d [mm] 0.6 force [N] duration [s] 5 305 TLF14CB : Apply the stated tensile force gradually in the direction to draw terminal. Nominal wire diameter tensile d [mm] 0.8 force [N] duration [s] 10 305 7. Temperature rise CM-RA/BU-RA Type Refer to individual specification CM-RB Type TLF9U, TLF14CB 45 max. Test method and remarks TLF : Resistance substitution method Applied current : Rated current Duration : 1 hour 8. Insulation resistance between wires CM-RA/BU-RA Type CM-RB Type 100M min. TLF9U, TLF14CB Test method and remarks CMTLF : Applied voltage : Rated voltage (CM-RA/BU-RA, CM-RB : 500VDC (TLF9UA, 14CB) : 250VDC (TLF9UB) Duration : 60sec. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0304_reli-RP1 1 co0304_reli_e-01 RELIABILITY DATA 9. Insulation resistance between wire and core CM-RA/BU-RA Type CM-RB Type 100M min. TLF9U, TLF14CB Test method and remarks TLF : Applied voltage : 500VDC (TLF9UA, 14CB) : 250VDC (TLF9UB) Duration : 60 sec. 10. Withstanding : between wires CM-RA/BU-RA Type CM-RB Type No abnormality TLF9U, TLF14CB Test method and remarks CMTLF : Applied voltage : 250VDC (CM-RA/BU-RA, CM-RB : 2000VAC (TLF9UA, 14CB : 500VDC (TLF9UB) Duration : 60sec. 11. Withstanding : between wires and core CM-RA/BU-RA Type CM-RB Type No abnormality TLF9U, TLF14CB Test method and remarks TLF : Applied voltage : 2000VAC (TLF9UA, 14CB) : 500VDC (TLF9UB) Duration : 60sec. 12. Rated voltage CM-RA/BU-RA Type CM-RB Type TLF9U, TLF14CB Test method and remarks : 250VAC TLF9UA, 14CB TLF9UB : 50VDC Within the specified range 13. Resistance to vibration CM-RA/BU-RA Type Inductance change : Within 15% CM-RB Type Appearance : No abnormality TLF14CB : Within the specified range TLF9U, TLF14CB TLF9U : Inductance change : Within 5 Test method and remarks CMTLF : According to JIS C 0040 Direction : 2hrs each in X, Y and Z direction Total : 6hrs Frequency range : 10 to 55 to 10Hz (1 min.) Amplitude : 1.5mm (shall not exceed acceleration 196m/s2) Mounting method : soldering onto PC board Recovery : 2 to 24 hrs of recovery under the standard condition after the test. (CM-RB) : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs. (TLF9U, 14CB) 14. Solderability CM-RA/BU-RA Type At least 75% of terminal electrode is covered by new solder. CM-RB Type TLF9U, TLF14CB Solder shall be uniformly adhered onto immersed surfaces. Test method and remarks Solder temperature : 2355 CM : Duration : 20.5sec. Immersion depth : According to detailed specification. TLF : Solder temperature : 2305 : 20.5sec. (9U) Duration : 30.5sec. (14CB) Immersion depth : Up to 1.0 to 1.5mm from PBC mounted level. 15. Resistance to soldering heat CM-RA/BU-RA Type Appearance : No abnormality CM-RB Type TLF9U, TLF14CB TLF9UA : Inductance change : Within 5% Test method and remarks Solder temperature : 2605 CM : Duration : 50.5sec. Immersion depth : Up to 22.5mm from terminal root. Recovery : 1 to 2 hrs of recovery under the standard condition after the test. TLF : Solder temperature Duration Immersion depth Recovery Inductance change : Refer to individual specification TLF14CB : Within the specified range : 2605 : 101sec. (9U, 14CB) : Up to 1.0 to 1.5mm from PBC mounted level. : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0304_reli_e-01 1 co0304_reli-RP2 RELIABILITY DATA 16. Thermnal shock CM-RA/BU-RA Type CM-RB Type Appearance : No abnormality Inductance change : Refer to individual specification TLF9UA : Inductance change : Within 15% TLF14CB : Withstanding voltage : No abnormality TLF9U, TLF14CB Insulation resistance : No abnormality Test method and remarks CM, TLF : According to JIS C 0025 Conditions for 1 cycle Step Temperature Durrationmin 1 253 303 2 Room Temperature Within 3 3 852 303 4 Room Temperature Within 3 Number of cycles : 10 Recovery : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2 hrs. 17. Damp heat CM-RA/BU-RA Type CM-RB Type TLF9UA : Inductance change : Within 15% TLF14CB : Withstanding voltage : No abnormality TLF9U, TLF14CB Insulation resistance : No abnormality Test method and remarks Temperature : 602 TLF : 402 (TLF14CB) Humidity : 9095RH Duration : 500 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. 18. Loading under damp heat CM-RA/BU-RA Type Appearance : No abnormality Inductance change : Refer to individual specification CM-RB Type Insulation resistance : No abnormality TLF9U, TLF14CB Withstanding voltage : No abnormality Test method and remarks Temperature : 402 CM : Humidity : 9095%RH Duration : 500 (12, 0) hrs Applied current : Rated current Recovery : 1 to 2hrs of recovery under the standard condition after the removal from test chamber. TLF : Temperature : 602 402 (TLF14CB) Humidity : 9095%RH Duration : 100 hrs 500 hrs Apply rated current across windings (TLF14CB) Applied voltage : Apply the following specified voltage between windings. Recovery TLF9UA 250VAC TLF9UB 50VDC : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. 19. Loading at high temperature CM-RA/BU-RA Type CM-RB Type Withstanding voltage : No abnormality TLF9U, TLF14CB Test method and remarks Temperature : 852 TLF : Duration : 100 hrs 500 hrs Apply rated current across windings (TLF14CB) Applied voltage : Apply the following specified voltage between windings. Recovery TLF9UA 250VAC TLF9UB 50VDC Insulation resistance : No abnormality : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. 20. Low temperature life test CM-RA/BU-RA Type CM-RB Type Appearance : No abnormality TLF9UA : TLF14CB : Inductance change : Refer to individual specification Inductance change : Within 15% Withstanding voltage : No abnormality TLF9U, TLF14CB Insulation resistance : No abnormality Test method and remarks Temperature : 403 CM : Duration : 500 (12, 0) hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from test chamber. (CM-RA) : 1 to 2hrs of recovery under the standard condition after the removal from test chamber. (CM-RB) TLF : Temperature : : Duration : Recovery : 252 402 (TLF14CB) 500 hrs At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0304_reli-RP3 1 co0304_reli_e-01 RELIABILITY DATA 21. High Temperature life test CM-RA/BU-RA Type CM-RB Type TLF9U, TLF14CB Appearance : No abnormality TLF9U : TLF14CB : Inductance change : Refer to individual specification Inductance change : Within 15% Withstanding voltage : No abnormality Insulation resistance : No abnormality Test method and remarks Temperature : 852 CM : Duration : 500 (12, 0) hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from test chamber. (CM-RA) : 1 to 2hrs of recovery under the standard condition after the removal from test chamber. (CM-RB) TLF : Temperature : 852 : 1053 (TLF14CB) Duration : 500 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber followed by the measurement within 2 hrs. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0304_reli_e-01 1 co0304_reli-RP4 PRECAUTIONS CM-RA Type, CM-RB Type, TLF Type 1. Circuit Design Operating environment 1. The products described in this specification are intended for use in general electronic equipment, (office supply equipment, telecommunications systems, measuring equipment, and household equipment). They are not intended for use in mission-critical equipment or systems requiring special quality and high Precautions reliability (traffic systems, safety equipment, aerospace systems, nuclear control systems and medical equipment including life-support systems) where product failure might result in loss of life, injury or damage. For such uses, contact TAIYO YUDEN Sales Department in advance. 2. PCB Design Design 1. Please design insertion pitches of a base in the pitches that fitted a terminal interval. Technical Design 1. When Inductors are mounted onto a PC board, hole dimensions on the board should match the lead pitch of the component, if not, it will cause breakage of considerations the terminals or cracking of terminal roots covered with resin as excess stress travels through the terminal legs. Precautions 3. Soldering Wave soldering 1. Please refer to the specifications in the catalog for a wave soldering. 2. Do not immerse the entire Inductors in the flux during the soldering operation. Lead free soldering 1. When using products with lead free soldering, we request to use them after confirming of adhesion, temperature of resistance to soldering heat, etc. sufficiently. Precautions Recommended conditions for using a soldering iron Put the soldering iron on the land-pattern. Soldering iron's temperature - Below 350 Duration - 3 seconds or less The soldering iron should not directly touch the product. Technical Lead free soldering 1. If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently degrade the reliability of considerations the products. 4. Cleaning Precautions Cleaning conditions 1. TLF type Please contact any of our offices for about a cleaning. 5. Handling Handling 1. Keep the product away from all magnets and magnetic objects. Mechanical considerations 1. Please do not give the product any excessive mechanical shocks. 2. TLF type Precautions Please do not add any shock or and power to a product in transportation. Packing 1. Please do not give the product any excessive mechanical shocks. In loading, please pay attention to handling indication mentioned in a packing box (a loading direction / number of maximum loading / fragile item). Handling 1. There is a case that a characteristic varies with magnetic influence. Mechanical considerations Technical 1. There is a case to be damaged by a mechanical shock. consider2. TLF type ations There is a case to be broken by a fall. Packing 1. There is a case that a lead route turns at by a fall or an excessive shock. 6. Storage conditions Storage 1. To maintain the solderability of terminal electrodes and to keep the packing material in good condition, temperature and humidity in the storage area should be controlled. Precautions Recommended conditions Ambient temperature : 040 Humidity : Below 70% RH The ambient temperature must be kept below 30. Even under ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, product should be used within one year from the time of delivery. Technical considerations In case of storage over 6 months, solderability shall be checked before actual usage. Storage 1. Under a high temperature and humidity environment, problems such as reduced solderability caused by oxidation of terminal electrodes and deterioration of taping/packaging materials may take place. This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. co0304_reli-RP5 1 co0304_reli_e-01