Special Features
Electrical Specs
1200 Watts
APA100 (PFC)
• Unity power factor
• High efficiency - up to 96%
• Universal input voltage and
frequency range
• Up to 1200W output power
• Parallelable with current sharing within 3%
• < 10% harmonic distortion
conforming to IEC555-2
• 85°C baseplate operating
temperature (no derating)
• High reliability - over 1 million
hours MTBF
• Power fail warning signal
• PLD feature
• Enable output to control AMPSS®
DC-DC converters
• 125Khz fixed Switching frequency
Operating temperature (baseplate):
-20°C to +85°C (no derating)
Storage temperature: -40°C to +105°C
Overtemperature protection: 90°C typical
MTBF: > 1 million hours (50°C baseplate)
Input
Input Voltage 85 to 265 Vac
Input Frequency 50/60 Hz
Efficiency 92% typical (VI = 115 Vac);
94% typical (VI = 230 Vac)
Total Harmonic Distortion Less than10%
Power Factor 0.99 typical (IO = 2A);
0.97 typical (IO = 1A)
Control
Power Fail Warning Direct drive output to opto-isolator
Power Fail Warning Adjust 205 to 355 Vdc adjustable
LD Enable Direct drive output to opto-isolator
PFC Enable TTL compatible (low to enable)
Voltage Adjust 240V to 393V
Clock Input (external sync) 3.3 to 5.5Vp-p @ 1MHz ± 5%
Clock Output (int. clock) 4.5Vp-p typical @ 1MHz ± 0.5%
Temperature
Monitor Output 10 mV/°K (2.73V = 0°C)
Current Monitor Output 0 to 1.28mA (1 mA = 2.5A)
Output
Output Voltage 383 V typical (IO = 2A); 393 V typical
(IO = 0A)
Current Share Accuracy 3% typical
Overvoltage Protection 417 V typical
Power Limit VIN=85Vac; Pmax=750W
VIN=180Vac; Pmax= 918W
VIN=230Vac; Pmax= 1200W
UL UL 1950 E132002
CSA CSA22.2-234 LR53 982C
CSA22.2-950
EN 60950 20396-3336-1012
VDE IEC950
CE CE Mark (LVD)
Environmental
Total Power: 1200 Watts
Input Voltages: 85-265 VAC
No. of Outputs: Single
Safety
Astec Integrated Power
America’s (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662
58
W9959_02_DCDC_001-073_73 2/8/02 3:55 PM Page 58