Accessory Installation
Protective boot
For use with flush, extended and double head
pushbutton operators only. To fit, discard
pushbutton sealing washer, then pull the rim of
the boot skirt over the bezel and flange of the
operator and secure operator to panel.
Padlock cover
Fit padlockable cover to operator then fit
additional panel seal (supplied) to operator
between padlockable cover and panel.
Mechanical push
For use with pushbutton and mushroom
operators (except twist to release and key
release). To install, cut to desired length and
insert into the back of operator.
Operator plug
Used for operating the center block on
pushbutton and mushroom operators (except
twist to release, key release, and push-push
types). To assemble, push plug into the back
of the operator. On mushroom operators cut
down the plug to 15.2mm (0.62) prior to
assembly. Plug is notched to indicate cut down
length.
Hole plug
These plugs seal unused 22.5mm openings
and include a panel sealing washer to provide
Enclosure Ratings 1, 2, 3, 3R, 4, 4X, 12, and
13.
Panel Mounting and Drilling
Dimensions
Panel thickness
Maximum 6.35mm (0.25). Minimum 1mm
(0.04). For each accessory used subtract
accessory thickness from 6.35mm (0.25).
pub17978
Revision 01
Effective 09/05 Page 1
UL Listed for use on a flat surface of type 1, 2, 3,
3R, 4, 4X, 12 and 13 enclosures.
NEMA Enclosure Types: 1, 2, 3, 3R, 4, 4X, 12, 13
Double Head Pushbutton:
without boot - NEMA Type 1
with boot - as listed above
Contact Rating Codes: A600 / Q600
E22BR1 Only: A600 / Q300
IEC 60947-5-1 / EN 60947-5-1
AC 15, DC 13, Pollution Degree 3
Ui = 690 V Uimp = 4KV
Ingress Protection (IEC 60529): IP 65
Double head pushbutton without boot: IP 40
Double head pushbutton with boot: IP 65
Degree of protection against electrical contact
(IEC 60529) - IP 2X Fingerproof protection.
Zb (Opposite Polarity)
Short Circuit Coordination
Fuse
GE Power Controls TIA 10
Red Spot Type gG, 10A, 660 VAC
460 VDC, BS88-2, IEC 60269-2-1
The installation and use of Cutler-Hammer products should be in accordance with the provisions of the U.S. National
Electrical Code and/or other local codes or industry standards that are pertinent to the particular end use. Installation
or use not in accordance with these codes and standards could be hazardous to personnel and/or equiptment.
LR 68551
LISTED
IND CONT EQ
A161
E 131568
Note: Do not use E22B4/E22B4R/E22BF4 Contact Blocks with Push-Push Operators.
Panel Spacing Mounting Dimensions
One or two conductors
0.75 - 4.0mm²
18 - 12 AWG
0.8 Nm (7 lb-in)
Solid or stranded (Do not mix)
Contact Blocks with Suffix R
Wiring terminals allow optional
connection of ring lugs.
Mounting adapter
Mounting nut
tightening torque
1.7 Nm (15 lb-in)
Anti-rotation ring
(if used)
Panel
Legend plate sealing
washer
E22VA series
70mm round
legend plate
Legend plate
Operator
or
Indicating light
Use Cutler-Hammer aluminum legend plates with
plastisol backing or E22VA series legend plates with
sealing washer to maintain UL type 3, 3R, 4, 4X, 12,
and 13 enclosure ratings, and IP 65 Ingress Protection.
Light Unit
Contact block
E22CW
Sealing washer
E22 Plastic Operators & Indicating Lights
Assembly
1
Click 2 Click
Disassembly
Depress Pad
1
1
2
Pull
Note: Gently push locking
lever and turn as shown
over locking nib
3
2
1
Depress Pad
Assembly
Disassembly
Transformer Units
Click Click
Depress 2 Pads
1
2
Pull
1
Depress 2 Pads
Minimum spacings:
Size/type of operator
All types except those listed
below
Lever selector switches and
40mm dia. operators
50mm dia. operators
Operators fitted with 70mm
dia. legend plate
Operators fitted with rubber
boots or padlockable covers
Double head pushbutton
Double head pushbutton
with boot
A
30 (1.18)
45 (1.77)
55 (2.16)
75 (2.95)
35 (1.38)
30 (1.18)
35 (1.38)
B
50 (1.97)
50 (1.97)
55 (2.16)
75 (2.95)
50 (1.97)
60 (2.36)
60 (2.36)
mm (inches)
Tolerances
+0.4/-0 (0.016/-0)
+0.4/-0 (0.016/-0)
»
+0.2/-0 (0.008/-0)
C
D
E
F
22.5 (0.89)
24.3 (0.96)
R0.8 (R0.03)
3.2 (0.125)
Dimensions
Panel Drilling
mm (inches)
F
E
(2 places)
D
B
C
A
Size/type of accessory
Legend plate
Anti-rotation ring
70mm legend plate
Padlockable cover
Rubber boot
mm (inches)
Thickness
1.25 (0.05)
1.5 (0.06)
1 (0.04)
2.4 (0.09)
1.3 (0.05)
Panel Spacing and Drilling
Effective 09/05 Page 3
pub17978
Effective 09/05Page 2
2 Position Push Pull Operators
12 11
14 13
14 13
12 11
14 13
3 Position Push Pull Operators
12 11
12 11
24 23
Contact blocks mounted in position 2 (right)
produces identical circuit configurations.
Push-Pull operators will accept a maximum of 2 contact blocks.
X = Circuit closed O = Circuit open = Position occupied
Selector Switch Operators
12 11
14 13
14 13
12 11
24 23
22 21
24 23
22 21
24 23
24A 23A
14 13
12 11
22 21
14 13
12 11
22 21
24 23
External
jumper
1. Determine the X O
sequence you require for your
application.
Example:
2. Locate the first sequence
X O O under column marked
Cam 1 or Cam 2, then identify
which cam and contact is used
and what position it is
assembled.
Example: X O O uses Cam
1, E22B2, mounting position 1
(left).
3. Repeat for second sequence
O O X. Do not mix
sequences from Cam 1 and
Cam 2.
Example: O O X uses Cam
1, E22B2, mounting position 2
(right).
4. Assemble contact block(s)
to adaptor in the mounting
position selected (two contact
blocks per switch), using the
selector switch with the
appropriate cam and switch
positions. Cam 1 has one
peak, Cam 2 has two peaks,
viewed from the back.
Terminal numbers
These identify the contact
position and contact function.
Example:
The 1 indicates sequence
(position) number 1. Numbers
3 & 4 indicate the circuit is
normally open.
NOTE: Do not use 5-way mounting adapter with E22B4/E22B4R/E22BF4 contact
blocks, 3-position push-pull operators, E22LTA emergency stop operators, push-push
operator or Cam 2 3-position selector switches.
X
O
O
O
O
X
Hand Off Auto
X = Circuit closed
O = Circuit open
= Position occupied
Explanation of How to Use Selector Switch Contact Block Selection Chart
Bulb Replacement - Front of Panel
14 13
Note: For ease in wiring two-circuit contact blocks, wire front terminals (terminals closest to panel) first.
pub17978
Contact Block Selection Charts
14A 13A
22 21
14A 13A
14 13
RISK OF OVERHEATING
To avoid damage to Illuminated Operators, do not exceed 60 V,
1.2 W Incandescent Bulb Ratings.
RISQUE DE SURCHAUFFE
Pour
éviter dendommager le dispositif lumineux, ne pas utiliser
une ampoule incandescente supérieure à 60 V, 1.2 W.
CAUTION ATTENTION
! !
* May include Suffix R
RISK OF ELECTRIC SHOCK
Turn power off before wiring and bulb replacement.
RISQUE DE CHOC
É
LECTRIQUE
Couper lalimentation
électrique avant de câbler ou de
remplacer une ampoule.
WARNING AVERTISSEMENT
Push-Push Operators -
Replace bulb from back of panel
0.6 Nm (5 lb-in)
0.6 Nm (5 lb-in)
0.6 Nm (5 lb-in) E22BA3
1.7 Nm (15 lb-in)
IP2X
0.75 - 2.5mm²
(18 - 14 AWG)
1.0 Nm (9 lb-in)
One or two conductors
Solid or stranded (Do not mix)
Standard Incandescent Bulb / LED
Indicating Lights
Illuminated Pushbuttons
(Tall LED may be used in
Push-Push illuminated
pushbuttons)
Bulb Type Usage Instructions
Tall Incandescent Bulb / LED
Illuminated Push-Pull
Operators
Illuminated Selector
Switches
Monoblock Indicating Light
Wiring and Mounting
Illuminated Selector Switches
and Push/Pull Operators
Indicating Lights and
Illuminated Pushbuttons
Double Head Pushbutton
Bulb Removal Tool
Circuit Configurations
(Viewed from front of
panel)
Contact Block Mounting
Position (Viewed from
back of panel) Contact
Arrangement
Contact
Block
E22B1
E22B2
E22B11
E22B20
Pulled
X
O
O
X
O
O
Pushed
O
X
X
O
X
X
Left
1
Center
3
Right
2*
Circuit Configurations
(Viewed from front of
panel)
Contact Block Mounting
Position (Viewed from
back of panel) Contact
Arrangement
Contact
Block
E22B1
E22B4
E22B1
E22B5
Pulled
X
X
X
O
Pushed
O
O
O
X
Left
1
Center
3
Right
2
Central
O
X
O
O
*
Contact
Block
(May include
Suffix R)
E22B2
E22B1
E22B11
E22B20
E22B2
E22B1
E22B11
E22B20
E22B11+B1
or E22B12
E22B11+B11
or E22B22
Contact Block Mounting
Position (Viewed from
back of panel)
Left
1
Center
3
Right
2
Contact
Arrangement
Circuit Configurations (Viewed from front of panel)
2 Position
Cam 2 Cam 1 Cam 2
3 Position
or
O
X
O
X
O
O
O
X
O
X
O
O
O
X
O
X
O
X
O
X
O
X
X
X
O
X
O
X
X
X
O
X
O
X
X
O
X
O
X
X
O
X
O
X
O
O
X
O
X
O
O
O
X
O
X
O
O
O
X
O
X
O
O
O
X
O
X
O
O
X
O
X
O
O
X
O
X
O
X
X
O
O
O
O
X
X
O
X
O
X
X
O
X
O
X
O
O
X
O
X
O
O
O
X
O
X
O
O
O
X
O
X
O
O
O
X
O
X
O
X
O
X
O
X
X
X
O
X
O
X
X
X
O
X
O
XB11B11
B1B11