Surge arrester 2-electrode arrester Series/Type: Ordering code: G31-A75X B88069X8091B502 Date: Version: 2019-11-04 07 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF. Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it! Identification/Classification 1 Surge arrester (header 1 + top left bar): Identification/Classification 2 2-electrode arrester (header 2 + bottom left header bar): Ordering code: (top right header bar) B88069X8091B502 Series/Type: (bottom right header bar) G31-A75X Preliminary data (optional): Department: PPD AB PD / PPD AB PM Date: 2019-11-04 Version: 07 TDK Electronics AG 2019. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without TDK Electronics' prior express consent is prohibited. Surge arrester 2-electrode arrester B88069X8091B502 G31-A75X Features Small size Fast response time Stable performance over life Low capacitance High insulation resistance RoHS-compatible Applications ESD protection Applications with limited space Electrical specifications DC spark-over voltage 1) 2) Tolerance Min. Max. 75 20 60 90 V % V V Impulse spark-over voltage at 100 V/s - for 99% of measured values - typical values of distribution at 1 kV/s - for 99% of measured values - typical values of distribution < 350 < 300 < 650 < 600 V V V V Service life 3) 300 operations 10 operations [5x (+) & 5x (-)] 1 operation 200 operations 100 1 2 500 A kA kA A Insulation resistance at 50 VDC >1 G Capacitance at 1 MHz < 0.5 pF Arc voltage at 1 A Glow to arc transition current Glow voltage ~ 10 <1 ~ 60 V A V Weight ~ 0.2 g Operation and storage temperature 40 ... +125 C Climatic category (IEC 60068-1) 40/125/21 Marking without 8/20 s 8/20 s 8/20 s contact discharge 4) 1) At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode 3) Tests according to ITU-T Rec. K. 12 and UL 497B 4) Contact discharge parameters: 1500 pF, 10 kV, 20 Terms in accordance with ITU-T Rec. K.12 and IEC 61643-311. 2) PPD AB PD / PPD AB PM Please read Cautions and warnings and Important notes at the end of this document. Version: 07 / 2019-11-04 Page 2 of 6 Surge arrester 2-electrode arrester B88069X8091B502 G31-A75X Dimensional drawing in mm Ordering codes and packing advices B88069X8091B502 = 500 pcs. on trays (50 pcs. per tray) PPD AB PD / PPD AB PM Please read Cautions and warnings and Important notes at the end of this document. Version: 07 / 2019-11-04 Page 3 of 6 Surge arrester 2-electrode arrester B88069X8091B502 G31-A75X Soldering parameter Wave soldering Wave profile features Solder Solder bath temperature Dwell time Pb-free assembly Sn 95.5 / Ag 3.8 / Cu 0.7 263 (3) C <3s Soldering profile applied to a single soldering process. Cautions and warnings Do not operate surge arresters in power supply networks, whose maximum operating voltage exceeds the minimum spark-over voltage of the surge arresters. Surge arresters may become hot in the event of longer periods of current stress (burn risk). In the event of overload the connectors may fail or the component may be destroyed. If the contacts of the surge arresters are defective, current load can cause sparks and loud noises. Surge arresters must be handled with care and must not be dropped. Do not continue to use damaged surge arresters. Display of ordering codes for TDK Electronics products The ordering code for one and the same product can be represented differently in data sheets, data books, other publications, on the company website, or in order-related documents such as shipping notes, order confirmations and product labels. The varying representations of the ordering codes are due to different processes employed and do not affect the specifications of the respective products. Detailed information can be found on the Internet under www.tdk-electronics.tdk.com/orderingcodes. PPD AB PD / PPD AB PM Please read Cautions and warnings and Important notes at the end of this document. Version: 07 / 2019-11-04 Page 4 of 6 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule we are either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether a product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms and Conditions of Supply. 7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The IATF certifications confirm our compliance with requirements regarding the quality management system in the automotive industry. Referring to customer requirements and customer specific requirements ("CSR") TDK always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949 may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that only requirements mutually agreed upon can and will be implemented in our Quality Management System. For clarification purposes we like to point out that obligations from IATF 16949 shall only become legally binding if individually agreed upon. Page 5 of 6 Important notes 8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS, DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.tdk-electronics.tdk.com/trademarks. Release 2018-10 Page 6 of 6