Coaxial Limiters
2690 Series
OUTLINE 1
V 4.00
Features
nBroadband Frequency Ranges
nEnvironmentally Sealed
nFeedback Leveling
nSmall Size
nReduced VSWR
Description
M/A-COM’s standard limiter series 2690 is a line of com-
pletely passive solid state receiver protectors. They exhibit
octave and multi-octave performance using a unique con-
struction technique involving PIN diodes in broadband
microstrip circuits. Careful diode selection allows a variety
of device performance, trading off peak and average power
handling, spike leakage and recovery time. Typical
insertion loss and VSWR curves are shown below.
Electrical Specifications: TA = 25°C
OUTLINE 2
Part
Number Frequency
Range
(GHz)
Insertion
Loss (dB) VSWR Average
Power (W) Peak
Power (W) Recovery
Time (nS) Leakage
Power
(mW)
Outline
Drawing
2690-1001 1.0 - 2.0 0.7 1.5:1 1.0 100 100 75 1
2690-1003 0.9 1.5:1 3.0 1000 1000 100 2
2690-1005 2.0 - 8.0 1.1 1.6:1 1.0 100 100 50 1
2690-1007 1.3 1.6:1 3.0 1000 1000 100 2
2690-1009 8.0 - 18.0 1.8 2.0:1 1.0 100 100 50 1
2690-1011 2.3 2.0:1 3.0 1000 1000 100 2
2690-1013 2.0 2.0:1 1.0 100 100 50 1
2690-1014 2.2 2.0:1 2.0 500 250 75 1
2690-1015 2.3 2.0:1 3.0 1000 1000 100 2
2.0 - 18.0
1. Insertion Loss and VSWR measured at 0 dBm input power.
2. Peak input power rated at 1 microsecond pulse width, 1% duty into 1.5:1 source VSWR and 1.15 load VSWR.
3. Spike leakage energy: 0.5 ergs max.
4. 1 dB compression: +7 dBm min.
Coaxial Limiters 2690 Series
Specifications subject to change without notice.
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
V 4.00
2
Environmental
Test MIL-STD Method Cond
Non-Destructive Bond
Pull 883 2023
Internal Visual 883 2017
Stabilization Bake 883 1008 B
Thermal Cycle 883 1010 B
Constant Acceleration 883 2001 A (Y1 Axis)
Burn-In 883 1015 125°C
Seal Fine
Gross 883
883 1014
1014 A1
C1
External Visual 883 2009
Absolute Maximum Ratings 5
5. Operation of this device above any one of these
parameters may cause permanent damage.
Parameter
Absolute Maximum
Operating Temperature -55°C to +85°C
Storage Temperature -65°C to +125°C
Devices are designed to meet the above screening conditions.
Typical Performance Curves
VSWR Insertion Loss
Leakage Power at 100 mW
-4.0
-3.0
-2.0
-1.0
0.0
2 4 6 10 12 14 16 18
Frequency (GHz)
Insertion Loss (dB)
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
2 4 6 8 10 12 14 16 18
Frequency (GHz)
VSWR (Ratio)
0
5
10
15
20
25
010 20 30 40 50 60
Power In (dBm)
Power Out (dBm)