68
L
N
L
N
L
N
PRODUCT CATALOGUE - STEGO
TECHNICAL DATA
Switch temperature difference 7 K (±4 K tolerance)
Sensor element thermostatic bimetal
Contact type snap-action contact
Service life > 100,000 cycles
Max. operating voltage AC 250 V (VDE)
AC 120 V (UL)
Max. inrush current AC 16 A for 10 sec.
Connection
2-pole terminal, clamping torque 0.5 Nm max.:
rigid wire 2.5 mm² (AWG 14)
stranded wire
1
1.5 mm² (AWG 16)
Mounting clip for 35 mm DIN rail, EN 60715
Casing plastic according to UL94 V-0, light grey
Dimensions 60 x 33 x 43 mm
Weight approx. 40 g
Fitting position variable
Operating/Storage temperature -45 to +80 °C (-49 to +176 °F)
Operating/Storage humidity max. 90 % RH (non-condensing)
Protection type IP20
¹ When connecting with wires, wire end ferrules must be used.
Important note: The contact system of the regulator is subjected to environmental influences, thus the contact resistance may
change. This can lead to a voltage drop and/or self-heating of the contacts.
The mechanical thermostats KTO 011 and KTS 011 are two state regulators used to control heaters, coolers, filter
fans or signal devices.
KTO 011: Thermostat (NC); contact breaker for regulating heaters. The contact opens when tempe
rature is rising.
KTS 011: Thermostat (NO); contact maker for regulating of filter fans and heat exchangers or for swit
ching signal
devises when temperature limit has been exceeded. The contact closes when temperature is rising.
> Large setting range
> Small size
> Simple to mount
> High switching performance
Connection diagrams
Thermostat
KTO 011 (NC)
Thermostat
KTS 011 (NO)
Examples of
connection
e.g. Signal deviceThermostat
KTS 011 (NO)
e.g. FanThermostat
KTS 011 (NO)
HeaterThermostat
KTO 011 (NC)
Heater
Filter fan, Cooling equipment, Signal device
SMALL COMPACT THERMOSTAT
KTO 011 / KTS 011
REGULATING
Setting range Art. No.
Contact breaker (NC)
Art. No.
Contact maker (NO)
Switching current/capacity max. Approvals
AC 250 V AC 120 V DC 24 - 72 V
0 to +60 °C 01140.0-00 01141.0-00 10 (2) A 15 (2) A 30 W VDE - - EAC
-10 to +50 °C 01142.0-00 01143.0-00 10 (2) A 15 (2) A 30 W VDE UL File No. E164102 - EAC
+20 to +80 °C 01159.0-00 01158.0-00 3 (2) A 3 (2) A 30 W VDE UL File No. E164102 CSA EAC
+32 to +140 °F 01140.9-00 01141.9-00 10 (2) A 15 (2) A 30 W VDE UL File No. E164102 CSA EAC
+14 to +122 °F 01142.9-00 01143.9-00 10 (2) A 15 (2) A 30 W VDE UL File No. E164102 CSA EAC
0 to +60 °C 01146.9-00 01147.9-00 10 (2) A 15 (2) A 30 W VDE UL File No. E164102 CSA EAC
19.03.2019 | Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. www.stego.de | www.stego.co.uk | www.stegonorden.se
68TECHNICAL DATASHEET