Data Sheet FieldIT SS/265GS/AS_3 2600T Series Pressure Transmitters Model 265GS Gauge Model 265AS Absolute standard overload Base accuracy : 0.04% Span limits - 0.2 to 60000kPa; 0.8inH2O to 8700psi - 0.3 to 3000kPa abs; 2.25mmHg to 435psia Reliable sensing system coupled with very latest digital technologies - provides large turn down ratio up to 100:1 Comprehensive sensor choice - optimize in-use total performance and stability 5-year stability Flexible configuration facilities - provided locally via local keys combined with LCD indicator or via hand held terminal or PC configuration platform Multiple protocol availability - provides integration with HART(R), PROFIBUS PA and FOUNDATION Fieldbus platforms offering interchangeability and transmitter upgrade capabilities Full compliance with PED Category III ABB 2600T Series Engineered solutions for all applications 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Functional Specifications Operative limits Range and span limits Temperature limits C (F) : Sensor Code Upper Range Limit (URL) Lower Range Limit (LRL) for 265GS Minimum span C 6kPa 60mbar 24inH2O -6kPa -60mbar -24inH2O 265GS gauge 0.2kPa 2mbar 0.8inH2O F 40kPa 400mbar 160inH2O -40kPa -400mbar -160inH2O 0.4kPa 4mbar 1.6inH2O 2kPa 20mbar 15mmHg L 250kPa 2500mbar 1000inH2O 0 abs 2.5kPa 25mbar 10inH2O 12.5kPa 125mbar 93.8mmHg 30kPa 0.3bar 4.35psi 100kPa 1bar 14.5psi 600kPa 6bar 87psi 150kPa 1.5bar 21.7psi U R V 3000kPa 30bar 435psi 10000kPa 100bar 1450psi 60000kPa 600bar 8700psi 0 abs 0 abs 0 abs 265AS absolute 0.3kPa 3mbar 2.25mmHg Note : Lower Range Limit (LRL) for 265AS is 0 abs for all ranges. Span limits Maximum span = URL IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. Zero suppression and elevation Zero and span can be adjusted to any value within the range limits detailed in the table as long as: - calibrated span minimum span Damping Adjustable time constant : 0 to 60s. This is in addition to sensor response time Turn on time Operation within specification in less than 2.5s with minimum damping. Insulation resistance > 100M at 1000VDC (terminals to earth) 2 Ambient (is the operating temperature) Silicone oil filling: -40C and +85C (-40F and +185F) Inert filling and white oil: -20C and +85C (-4F and +185F) Lower limit for Viton gasket: -20C (-4F) Lower limit for perfluoroelastomer gasket: -15C (+5F) Note : For Hazardous Atmosphere applications see the temperature range specified on the certificate/approval relevant to the aimed type of protection. Process Lower limit - -50C (-58F); -20C (-4F) for Viton gasket. -15C (+5F) for perfluoroelastomer gasket Upper limit - Silicone oil, inert fluid and white oil: 121C (250F) Storage Lower limit: -50C (-58F); -40C (-40F) for LCD indicators Upper limit: +85C (+185F) Pressure limits Overpressure limits (without damage to the transmitter) 0 absolute to - 1MPa, 10bar, 145psi for sensor codes C, F - 0.5MPa, 5bar, 72.5psi for sensor code L - 6MPa, 60bar, 870psi for sensor code U - 20MPa, 200bar, 2900psi for sensor code R - 90MPa, 900bar, 13050psi for sensor code V - 0.6MPa, 6bar, 87psi for perfluoroelastomer gasket Proof pressure The transmitter can be exposed without leaking to line pressure of up to - 1MPa, 10bar, 145psi for sensor codes C, F - 0.5MPa, 5bar, 72.5psi for sensor code L - 6MPa, 60bar, 870psi for sensor code U - 20MPa, 200bar, 2900psi for sensor code R - 90MPa, 900bar, 13050psi for sensor code V - 0.6MPa, 6bar, 87psi for perfluoroelastomer gasket 2600T Pressure Transmitters Model 265GS, 265AS Environmental limits Electromagnetic compatibility (EMC) Definition Class 3 Radio suppression Limit class B (according to EN 550011) Fulfills NAMUR recommendation Low voltage directive Comply with 73/23/EEC Pressure equipment directive (PED) Comply with 97/23/EEC Category III module H. Humidity Relative humidity: up to 100% annual average Condensing, icing: admissible Vibration resistance Accelerations up to 2g at frequency up to 1000Hz (according to IEC 60068-2-26) Shock resistance (according to IEC 60068-2-27) Acceleration: 50g Duration: 11ms Wet and dust-laden atmospheres The transmitter is dust and sand tight and protected against immersion effects as defined by IEC EN60529 (1989) to IP 67 (IP 68 on request) or by NEMA to 4X or by JIS to C0920. Hazardous atmospheres - Transmitters of the type of protection "Intrinsically safe EEx ia" according to the directions 94 / 9 / EC (ATEX) Transmitter with 4 to 20mA output signal and HART communication Marking (DIN EN 50 014): II 1/2 GD T50C EEx ia IIC T6 or resp. II 1/2 GD T95C EEx ia IIC T4 Supply and signal circuit type of protection Intrinsic Safety EEx ib IIB/IIC resp. EEx ia IIB/IIC for connection to supply units with maximum values: II 1/2 GD T50C EEx ia resp. ib IIC T6 resp. II 1/2 GD T95C EEx ia resp. ib IIC T4 for Temperature class T4 resp. T95C: Ui = 30V Ii = 200mA Pi = 0.8W for T4 with Ta = (-40 to +85)C / (-40 to +185)F Pi = 1.0W for T4 with Ta = (-40 to +70)C / (-40 to +158)F for Temperature class T6 resp. T50C: Pi = 0.7W for T6 with Ta = (-40 to +40)C / (-40 to +104)F effective internal capacitance, Ci 10nF effective internal inductance, negligible. Fieldbus transmitters (PROFIBUS PA / FOUNDATION Fieldbus) Marking (DIN EN 50 014): II 1/2 GD T50C EEx ia IIC T6 or resp. II 1/2 GD T95C EEx ia IIC T4 Supply and signal circuit type of protection Intrinsic Safety EEx ib IIB/IIC resp. EEx ia IIB/IIC for connection to FISCO supply units with rectangular or trapezoidal characteristics with maximum values: II 1/2 G EEx ia respectively ib IIC T4/T6 Ui = 17.5V Ii = 360mA Pi = 2.52W II 1/2 G EEx ia respectively ib IIB T4/T6 Ui = 17.5V Ii = 380mA Pi = 5.32W SS/265GS/AS_3 resp. for connection to supply unit or barrier with linear characteristics with maximum values: II 1/2 G EEx ia respectively ib IIC T4/T6 Ui = 24V li = 250mA Pi = 1.2W effective internal inductance Li 10 H, effective internal capacitance Ci 0 Maximum permissible ambient temperatures depending on the temperature class: T4: -40C to +85C (-40F to +185F) T5, T6: -40C to +40C (-40F to +104F) - Transmitters of the type of protection "flameproof enclosure EEx d" according to the directions 94 /9 / EC (ATEX) Transmitter with 4 to 20mA output signal and HART communication and Fieldbus transmitters (PROFIBUS PA / FOUNDATION Fieldbus) Marking (DIN EN 50 014): II 1/2 G EEx d IIC T6 Ambient temperature range: -40C to +75C (-40F to +167F) - Transmitters of category 3 for the application in "Zone 2" Transmitter with 4 to 20mA output signal and HART communication according to the directions 94 / 9 / EC (ATEX) Marking (DIN EN 50 014): II 3 GD T50C EEx nL IIC T6 or resp. II 3 GD T95C EEx nL IIC T4 Operating conditions: Supply and signal circuit (terminals signal +/-): U 45V I 22.5mA Ambient temperature range: Temperature class T4 Ta=-40C to +85C (-40F to +185F) Temperature class T5, T6 Ta=-40C to +40C (-40F to +104F) - Factory Mutual (FM) Transmitter with 4 to 20mA output signal and HART communication Intrinsically safe: Class I; Division 1; Groups A, B, C, D; Class I; Zone 0; Group IIC; AEx ia IIC Degree of protection : NEMA Type 4X (indoor or outdoor) Permissible ambient temperature depending on temperature class Umax = 30V, Ci = 10.5nF, Li = 10H Ambient Temperature -40 to +85 -40 to +70 -40 to +40 -40 to +40 C (-40 to +185 C (-40 to +129 C (-40 to +104 C (-40 to +104 F) F) F) F) Temperature Imax class T4 200mA T4 200mA T5 25mA T6 25mA Pi 0.8W 1W 0.75W 0.5W Fieldbus transmitters (PROFIBUS PA/FOUNDATION Fieldbus) Intrinsically Safe : Class I, II and III; Division 1; Groups A, B, C, D, E, F, G; Class I; Zone 0, AEx ia Group IIC T6; T4 Non-incendive Class I, II and III, Division 2; Groups A, B, C, D, F, G Transmitter with 4 to 20mA output signal and HART communication and Fieldbus transmitters (PROFIBUS PA/FOUNDATION Fieldbus) Explosion-Proof: Class I; Division 1; Groups A, B, C, D; Class II/III, Division 1; Groups E, F, G Degree of protection : NEMA Type 4X (indoor or outdoor) - Canadian Standard (CSA) Transmitter with 4 to 20mA output signal and HART communication and Fieldbus transmitters (PROFIBUS PA/FOUNDATION Fieldbus) Explosion-Proof: Class I; Division 1; Groups B, C, D Class II; Division 1; Groups E, F, G Class III Degree of protection : NEMA Type 4X (indoor or outdoor) 3 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Electrical Characteristics and Options Optional indicators HART digital communication and 4 to 20mA output Integral display Power Supply The transmitter operates from 10.5 to 45VDC with no load and is protected against reverse polarity connection (additional load allows operations over 45VDC). Minimum power supply is 14VDC with backlit indicator. For EEx ia and other intrinsically safe approval power supply must not exceed 30VDC. 2-line, 6-character 19-segment alphanumeric display with additional bar chart display, optionally with back illumination. User-specific display: percentage of the output current or output current in mA or free process variable Diagnostic message, alarms, measuring range infringements and changes in the configuration are also displayed. Ripple Maximum permissible voltage ripple of power supply during the communication: Optional surge protection Up to 4kV 7Vpp at f = 50 to 100Hz - voltage 1.2s rise time / 50s delay time to half value 1Vpp at f = 100 to 200Hz - current 8s rise time / 20s delay time to half value 0.2Vpp at f = 200 to 300Hz Load limitations 4 to 20mA and HART total loop resistance : R(k) = Supply voltage - min. operating voltage (VDC) --------------------------------------- 22.5 mA Output signal Two-wire 4 to 20mA, user-selectable for linear or freely programmable with 20 reference points output. HART(R) communication provides digital process variable (%, mA or engineering units) superimposed on 4 to 20mA signal, with protocol based on Bell 202 FSK standard. Output current limits (to NAMUR standard) A minimum of 250 is required for HART communication. Overload condition - Lower limit: 3.8mA (configurable down to 3.5mA) - Upper limit: 20.5mA (configurable up to 22.5mA) Alarm current Min. alarm current: configurable from 3.5mA to 4mA, standard setting: 3.6mA Max. alarm current: configurable from 20mA to 22.5mA, standard setting: 21mA Standard setting: max. alarm current 4 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 PROFIBUS PA output FOUNDATION Fieldbus output Device type Power supply Pressure transmitter compliant to Profile 3.0 Class A & B; ident. number 04C2 HEX. Power supply The transmitter operates from 10.2 to 32VDC with no polarity. For EEx ia approval power supply must not exceed 17.5VDC. Intrinsic safety installation according to FISCO model. Current consumption operating (quiescent): 11.7mA fault current limiting: 17.3mA max. The transmitter operates from 10.2 to 32VDC polarity independent. For EEx ia approval power supply must not exceed 24VDC (entity certification) or 17.5VDC (FISCO certification), according to FF-816. Current consumption operating (quiescent): 11.7mA fault current limiting: 17.3mA max. Output signal Physical layer in compliance to IEC 1158-2/EN 61158-2 with transmission to Manchester II modulation, at 31.25kbit/sec. Output signal Physical layer in compliance to IEC 1158-2/EN 61158-2 with transmission to Manchester II modulation, at 31.25kbit/sec. Output interface PROFIBUS PA communication according to Profibus DP50170 Part 2/ DIN 19245 part 1-3. Output update time 40ms Function blocks 1 Analog Input, 1 Transducer, 1 Physical Integral display 2-line, 6-character 19-segment alphanumeric display with additional bar chart display, optionally with back illumination. User-specific display: percentage of the output or OUT (analog input function block) Diagnostic message, alarms, measuring range infringements and changes in the configuration are also displayed. Transmitter failure mode Permanent self-diagnostic; possible errors indicated in diagnostic parameters and in the status of process values. Function blocks/execution period 1 standard Analog Input block/25ms max Additional blocks 1 custom Pressure with calibration Transducer block 1 enhanced Resource block Number of link objects 10 Number of VCRs 16 Output interface FOUNDATION fieldbus digital communication protocol to standard H1, compliant to specification V. 1.5; FF registration in progress. Integral display 2-line, 6-character 19-segment alphanumeric display with additional bar chart display, optionally with back illumination. User-specific display: percentage of the output or OUT (analog input ) Diagnostic message, alarms, measuring range infringements and changes in the configuration are also displayed. Transmitter failure mode Permanent self-diagnostic; possible errors indicated in diagnostic parameters and in the status of process values. 5 2600T Pressure Transmitters Model 265GS, 265AS Performance specifications Stated at reference condition to IEC 60770 ambient temperature of 20C (68F), relative humidity of 65%, atmospheric pressure of 1013hPa (1013mbar), zero based range for transmitter with isolating diaphragms ceramic or Hastelloy and silicone oil fill and HART digital trim values equal to 4-20mA span end points, in linear mode. SS/265GS/AS_3 Operating influences Ambient temperature (for turndown up to 15:1) per 20K (36F) change between the limits of -20C to +65C (-4 to +150F) - (0.03% URL + 0.05% span) Unless otherwise specified, errors are quoted as % of span. Some performance data (based to URL) are affected by the actual turndown (TD) as ratio between Upper Range Limit (URL) and calibrated span. IT IS RECOMMENDED TO SELECT THE TRANSMITTER SENSOR CODE PROVIDING THE TURNDOWN VALUE AS LOWEST AS POSSIBLE TO OPTIMIZE PERFORMANCE CHARACTERISTICS. Supply voltage Within voltage/load specified limits the total effect is less than 0.001% of URL per volt. Load Within load/voltage specified limits the total effect is negligible. Radio frequency interference Dynamic performance (according to IEC 61298-1 definition) Dead time: 30ms Total effect : less than 0.05% of span from 20 to 1000MHz and for field strengths up to 10V/m when tested with unshielded conduit, with or without meter. Time constant (63.2% of total step change): Common mode interference - 150 ms for all sensors No effect from 250Vrms @ 50Hz, or 50VDC Accuracy rating Stability % of calibrated span, including combined effects of terminal based linearity, hysteresis and repeatability. For fieldbus versions SPAN refer to Analog Input Function Block outscale range - 0.04% for TD from 1:1 to 10:1 URL - (0.04 + 0.005 x Span 6 - 0.05)% for TD greater than 10:1 0.10% of URL over a thirty-six-month period Vibration effect 0.10% of URL (according to IEC 61298-3) 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Physical Specification Optional extras (Refer to ordering information sheets for variant availability related to specific model or versions code) Mounting brackets For vertical and horizontal 60mm. (2in) pipes or wall mounting. Materials Integral display Process isolating diaphragms (*) plug-in rotatable LCD indicator Ceramic (Al203) gold-plated; Hastelloy C276TM; Hastelloy C276TM gold-plated; AISI 316 L ss. Process connection (*) AISI 316 L ss; Hastelloy C276TM. Gasket (only for sensor codes C, F) (*) VitonTM, Perfluoroelastomer, Perbunan (NBR). Sensor fill fluid Silicone oil; inert fill (Carbon fluoride); white oil (FDA). Mounting bracket AISI 316 L ss. Sensor housing AISI 316 L ss. Electronic housing and covers Barrel version - Low-copper content aluminium alloy with baked epoxy finish; Supplemental customer tag AISI 316 ss tag fastened to the transmitter with stainless steel wire for customer's tag data up to a maximum of 30 characters and spaces. Surge protection not available with ATEX-EEx nL or PROFIBUS PA / FOUNDATION Fieldbus with Intrinsic Safety EEx i or FM-Intrinsically Safe. Cleaning procedure for oxygen service (not for sensor V) Test Certificates (test, design, calibration, material traceability) Tag and manual language Communication connectors Process connections 1 /2in NPT female or male; DIN EN837-1 G 1/2in Form B or Form D for convex seal; front bonded diaphragm; for ball valve. Electrical connections - AISI 316 L ss. Two 1/2 NPT or M20x1.5 threaded conduit entries, direct on housing. DIN version Communication connector: - Low-copper content aluminium alloy with baked epoxy finish. - HART: straight or angle Harting Han 8U connector and one plug. Covers O-ring VitonTM. Local zero and span adjustments Glass filled polycarbonate plastic (removable). Tagging AISI 316ss or plastic data plate attached to the electronics housing. Calibration Standard: at maximum span, zero based range, ambient temperature and pressure; Optional: at specified range and ambient conditions; or at operating temperature. - PROFIBUS PA, FOUNDATION Fieldbus : M12x1 or 7/8 (without mating female plug) Terminal block HART version: four terminals for signal/external meter wiring up to 2.5mm2 (14AWG) and four connection points for test and communication purposes. Fieldbus versions: two terminals for signal (bus connection) wiring up to 2.5mm2 (14AWG). Grounding Internal and external 4mm2 (12AWG) ground termination points are provided. Mounting position Transmitter can be mounted in any position. Electronics housing may be rotated by 360. A positive stop prevents over travel. Mass (without options) 1.2kg approx (3lb); add 1.5kg (3.4lb) for AISI housing. Add 650g (1.5lb) for packing. Packing Carton 24 x 14 x 19cm approx (10 x 6 x 8in). 7 2600T Pressure Transmitters Model 265GS, 265AS Configuration Transmitter with HART communication and 4 to 20 mA Standard configuration Transmitters are factory calibrated to customer's specified range. Calibrated range and tag number are stamped on the type plate. If calibration range and tag data are not specified, the transmitter will be supplied configured as follows: 4 mA Zero 20 mA Upper Range Limit (URL) Output Linear Damping 0.125s Transmitter failure mode 21mA Any or all the above configurable parameters, including Lower range-value and Upper range-value which must be the same unit of measure, can be easily changed using the HART hand-held communicator or by a PC running the configuration software SMART VISION with DTM for 2600T. The transmitter database is customized with specified flange type and material, o-ring and filling liquid. Transmitter with PROFIBUS PA communication Transmitters are factory calibrated to customer's specified range. Calibrated range and tag number are stamped on the type plate. If calibration range and tag data are not specified, the transmitter will be supplied configured as follows: Measure Profile Pressure Engineering Unit mbar/bar Output scale 0% Lower Range Limit (LRL) Output scale 100% Upper Range Limit (URL) Output Linear Hi-Hi Limit Upper Range Limit (URL) Hi Limit Upper Range Limit (URL) Low Limit Lower Range Limit (LRL) Low-Low Limit Lower Range Limit (LRL) Limits hysteresis 0.5% of output scale PV filter 0.125s. Address 126 Any or all the above configurable parameters, including Lower range-value and Upper range-value which must be the same unit of measure, can be easily changed by a PC running the configuration software SMART VISION with DTM for 2600T. The transmitter database is customized with specified flange type and material, o-ring and filling liquid. 8 SS/265GS/AS_3 Transmitter with FOUNDATION Fieldbus communication Transmitters are factory calibrated to customer's specified range. Calibrated range and tag number are stamped on the type plate. If calibration range and tag data are not specified, the transmitter will be supplied configured as follows: Measure Profile Pressure Engineering Unit mbar/bar Output scale 0% Lower Range Limit (LRL) Output scale 100% Upper Range Limit (URL) Output Linear Hi-Hi Limit Upper Range Limit (URL) Hi Limit : Upper Range Limit (URL) Low Limit Lower Range Limit (LRL) Low-Low Limit Lower Range Limit (LRL) Limits hysteresis 0.5% of output scale PV filter 0.125s Address Not necessary Any or all the above configurable parameters, including lower range value and upper range value which must be the same unit of measure, can be changed by any FOUNDATION Fieldbus compatible configurator. The transmitter database is customized with specified flange type and material, o-ring and filling liquid. TM Hastelloy is a Cabot Corporation trademark TM Viton is a Dupont de Nemour trademark (*) Wetted parts of the transmitter. 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 MOUNTING DIMENSIONS (not for construction unless certified) - dimensions in mm (in) Transmitter with barrel housing 9 (0.35) Space must be available to rotate the key-board cover 23 (0.91) with LCD indicator 114 (4.49) 58 (2.28) 20 (0.79) 70 (2.76) Clearance for cover removal A 29 (1.14) 124 (4.88) Additional tag plate 76 (2.99) Housing rotation stop screw 140 (5.51) 26 (1.02) Terminal side 28 (1.10) 56 (2.20) Process connection Plate with keys legend Electrical connections (with gland) Dimension "A" is dependent upon range and process connection: Identification plate Sensor codes C, F Sensor codes L, U, R, V 1/2-14NPT male thread 168 (6.61) 173 (6.81) 1/2-14NPT female thread 158 (6.22) 169 (6.65) 172 (6.77) - sensor V DIN EN 837 G 1/2in Form B 167 (6.58) 173 (6.81) DIN EN 837 G 1/2in Form D for convex seal 178 (7.01) 183 (7.20) Front bonded diaphragm --- see next For ball valve connection ---- see next 83 (3.27) Process connection Captive screw for keys unit cover Housing cover 42 (1.65) Electrical connection (with plug) 9 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Transmitter with DIN housing Space must be available to rotate the key-board cover 100 (3.94) 26 (1.02) 70 (2.76) Additional tag plate 58 (2.28) 23 (0.91) 20 (0.79) 124 (4.88) 76 (2.99) 136 (5.35) / *140 (5.51) A 20 (0.79) Housing cover Electrical connection (with gland) Process connection 48 (1.89) *16 (0.63) 12 (0.47) 61 (2.40) Housing rotation stop screw 47 (1.85) *28 (1.10) 56 (2.20) Groove for screws (wall or pipe mounting) Terminal side 83 (3.27) Captive screw for keys unit cover * dimensions of sensor code L, U, R, V Dimension "A" is dependent upon range and process connection: Process connection 1/2-14NPT male thread Sensor codes C, F Sensor codes L, U, R, V 168 (6.61) 173 (6.81) 1/2-14NPT female thread 158 (6.22) 169 (6.65) 172 (6.77) - sensor V DIN EN 837 G 1/2in Form B 167 (6.58) 173 (6.81) DIN EN 837 G 1/2in Form D for convex seal 178 (7.01) 183 (7.20) Front bonded diaphragm --- see next For ball valve connection ---- see next 10 Plate with keys legend 130 (5.12) Identification plate 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Transmitter with front bonded diaphragm (Barrel housing) 114 (4.49) 58 (2.28) 9 (0.35) Weld-on adaptor and socket Front bonded diaphragm o 50 o 21.3 -0.2 Chamfer after tapping 172 (6.77) G 1/2 o 19.4 +0.1 0.1 A (0.81) 15 -0.2 21 groove for sealing ring DIN 3869-21 (18.5x23.9x1.5) G 1/2 B groove for O-ring (15x2) A 18 (0.71) 10 (0.39) 20.5 29 (1.14) min. 10.5 width across flats 27mm Burrless. o 18.2 +0.1 28 (1.10) 56 (2.20) 272 (10.71) Vent hose width across flats 36mm 20 37 (1.46) (0.79) 25 (0.98) 146 (5.75) Washer 29 (1.14) 222 (8.74) 76 (2.99) Transmitter with ball valve connection (Barrel housing) 29.6 (1.17) G1in Conical seal metal / metal (hygienic design) The diaphragm is process-bonded 25 (0.98) diaphragm~O: ~20 (0.79) 11 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Possible mounting with bracket (optional) for DIN housing 23 (0.91) 154 (6.06) 26 (1.02) 58 (2.28) 39 (1.54) 20 (0.79) 100 (3.94) 26 (1.02) 58 (2.28) 23 (0.91) 20 (0.79) 11 (0.43) 39 (1.54) 72 (2.83) 110 (4.33) 20 (0.79) 101 (3.99) 81 (3.19) Wall mounting Pipe mounting Possible mounting with bracket (optional) for Barrel housing 197 (7.76) 39 (1.54) 114 (4.49) 58 (2.28) 9(0.35) 23 (0.91) 177 (6.97) 39 (1.54) 20 (0.79) 114 (4.49) 58 (2.28) 9(0.35) 23 (0.91) 20 (0.79) 97 (3.82) 72 (2.83) 110 (4.33) 97 (3.82) 20 (0.79) 44(1.73) 60 (2.36) 44 (1.73) 60 (2.36) 118 (4.65) 98 (3.86) Pipe mounting Wall mounting Note : Bracket both for pipe and wall mounting provides four holes of 11mm (0.44in) diameter on square with 72mm (2.84in) side 12 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Electrical connections Standard Terminal block and fieldbus connector versions Earthing/potential Output signal/ Test sockets for 4...20mA equalizing terminal power supply (not in function with fieldbus transmitters) 7/8" connector Cable entry 1 3 2 4 M12 x 1 connector 2 Screw terminals for 0.5...2.5mm2 - wires 1 3 4 PIN (male) IDENTIFICATION FOUNDATION PROFIBUS Fieldbus PA 1 FFPA+ 2 FF+ GROUND 3 SHIELD PA- 4 GROUND SHIELD Mating female plug NOT SUPPLIED Harting Han 8U connector 89 (3.5) 1 2 51 (2.01) + Harting pin identification (view onto socket) 26 (1.02) 13 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 BASIC ORDERING INFORMATION model 265GS Gauge Pressure Transmitter Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required. BASE MODEL - 1st to 5th characters 2 6 5 G S X X X X X X Gauge Pressure Transmitter - BASE ACCURACY 0.04% SENSOR - Span limits - 6th character 0.2 and 6kPa 2 and 60mbar 0.8 and 24inH2O 0.4 and 40kPa 4 and 400mbar 1.6 and 160inH2O 10 and 1000inH2O 2.5 and 250kPa 25 and 2500mbar 4.35 and 435psi 30 and 3000kPa 0.3 and 30bar 14.5 and 1450psi 100 and 10000kPa 1 and 100bar 87 and 8700psi 600 and 60000 kPa 6 and 600bar th Diaphragm material / Fill fluid (wetted parts) - 7 character AISI 316 L ss Silicone oil Hastelloy C276TM Silicone oil Hastelloy C276TM gold-plated Silicone oil AISI 316 L ss Inert fluid Hastelloy C276TM Inert fluid Hastelloy C276TM gold-plated Inert fluid AISI 316 L ss White oil (FDA) Hastelloy C276TM White oil (FDA) Ceramic No filling th Process connection material (wetted parts) - 8 character AISI 316 L ss AISI 316 L ss AISI 316 L ss AISI 316 L ss AISI 316 L ss AISI 316 L ss Hastelloy C276TM Hastelloy C276TM Hastelloy C276TM Hastelloy C276TM Gasket - 9th character C F L U R V (Note 2) only for front bonded diaphragm (Note 2) (Note 2) (Notes 1, 2) only for front bonded diaphragm (Notes 1, 2) (Notes 1, 2) (Note 2) only for front bonded diaphragm (Note 2) (Note 3) NACE NACE NACE NACE NACE NACE NACE NACE NACE 1 /2in NPT female DIN EN837-1 G 1/2in B G 1/2in front bonded diaphragm 1 /2in NPT male DIN EN837-1 G 1/2in D For ball valve connection 1 /2in NPT female DIN EN837-1 G 1/2in B 1 /2in NPT male DIN EN837-1 G 1/2in D NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE (Note 2) (Note 2) VitonTM (Notes 1, 3) Perfluoroelastomer (MWP=0.6MPa) (Note 3) Perbunan (Note 3) None (Note 2) Housing material and electrical connection - 10h character Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) NACE NACE NACE 1 /2in NPT M20 x 1.5 (CM 20) Harting Han 8U connector Fieldbus connector 1 /2in NPT M20 x 1.5 (CM 20) M20 x 1.5 (CM 20) Harting Han 8U connector Fieldbus connector (Not available FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Not available FM, CSA) (Not available FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) S K G A F E N Z J B P S T U V E D K Y 5 6 8 N A B E G S T J K W Output/Additional options - 11th character HART digital communication and 4 to 20mA HART digital communication and 4 to 20mA PROFIBUS PA PROFIBUS PA FOUNDATION Fieldbus FOUNDATION Fieldbus 14 No additional options Options requested (to be ordered by "Additional ordering code") No additional options Options requested (to be ordered by "Additional ordering code") No additional options Options requested (to be ordered by "Additional ordering code") (Note 5, 6) (Note 5) (Note 5, 6) (Note 6) (Note 5, 6) (Note 6) H 1 P 2 F 3 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 ADDITIONAL ORDERING INFORMATION for model 265GS Add one or more 2-digit code(s) after the basic ordering information to select all required options XX XX XX XX XX XX XX XX XX XX XX Electrical certification ATEX Group II Category 1/2 GD - Intrinsic Safety EEx ia ATEX Group II Category 1/2 G - Flameproof EEx d (Note 2) ATEX Group II Category 3 GD - Type of protection "N" EEx nL energy limited Factory Mutual (FM) - Intrinsically Safe Factory Mutual (FM) - Explosion Proof (only with 1/2in NPT electrical connection and SS label) Canadian Standard Association - Intrinsically Safe (pending) Canadian Standard Association - Explosion Proof (Note 2) Integral LCD Digital LCD integral display Backlit digital LCD integral display Mounting bracket (shape and material) For pipe mounting AISI 316 L ss For wall mounting AISI 316 L ss Surge Surge/Transient Protector (Note 7) (Note 2) E1 E2 E3 EA EB ED EE L1 L2 B2 B4 S1 Operating manual German M1 Labels & tag language German in stainless steel (not available with DIN Electronic Housing code J, K, W) German and English plastic (not suitable for Factory Mutual - Explosion Proof) Additional tag plate In stainless steel T1 TA I1 Preparation procedure Oxygen service cleaning (only available with inert fill and for sensor code C, F Viton gasket - Pmax=21MPa/210bar/3045psi; Tmax=60 C/140 F) P1 Certificates Inspection certificate EN 10204-3.1.B of calibration Inspection certificate EN 10204-3.1.B of the cleanliness stage according to DIN 25410 Inspection certificate EN 10204-3.1.B of helium leakage test of the sensor module Inspection certificate EN 10204-3.1.B of the pressure test Certificate of compliance with the order EN 10204-2.1 of instrument design Germanischer Lloyd approval C1 C3 C4 C5 C6 C8 Material traceability Certificate of compliance with the order EN 10204-2.1 of process wetted parts Inspection certificate EN 10204-3.1.B of process wetted parts (small parts with certificate of compliance EN 10204) Test report EN 10204-2.2 of the pressure bearing and process wetted parts H1 H3 H4 Connector Fieldbus 7/8 (without mating female plug) Fieldbus M12x1 (without mating female plug) Harting Han 8U - straight entry Harting Han 8U - angle entry (Notes 6, 8) (Notes 6, 8) (Notes 5, 8) (Notes 5, 9) U1 U2 U3 U4 15 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Note 1: Suitable for oxygen service Note 2: Not available with Sensor code C, F Note 3: Not available with Sensor code L, U, R, V Note 4: Select type in additional ordering code Note 5: Not available with Electronic Housing code G, W Note 6: Not available with Electronic Housing code E, K Note 7: Not available with ATEX-EEx nL (code E3) or PROFIBUS PA / FOUNDATION Fieldbus (code 2 or 3) with Intrinsic Safety EEx i (code E1) or FM-Intrinsically Safe (code EA). Note 8: Not available with Electronic housing code T, S, A, B, J Note 9: Not available with Electronic housing code T, S, A, B, J, K TM Hastelloy is a Cabot Corporation trademark TM Viton is a Dupont de Nemour trademark Standard delivery items (can be differently specified by additional ordering code) - General purpose (no Ex design) - No meter/display, no mounting bracket, no surge protection - English manual and labels (stainless steel nameplate for Barrel housing code A, B, E, G, S, T; plastic nameplate for DIN housing code J, K, W) - Configuration with kPa and deg. C units - No test, inspection or material traceability certificates THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'S RESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING. 16 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 BASIC ORDERING INFORMATION model 265AS Absolute Pressure Transmitter Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information code and specify one or more codes for each transmitter if additional options are required. BASE MODEL - 1st to 5th characters 2 6 5 A S X X X X X X Absolute Pressure Transmitter - BASE ACCURACY 0.04% SENSOR - Span limits - 6th character 0.3 and 6kPa 3 and 60mbar 2.25 and 45mmHg 2 and 40kPa 20 and 400mbar 15 and 300mmHg 12.5 and 250kPa 125 and 2500mbar 93.8 and 1875mmHg 150 and 3000kPa 1.5 and 30bar 21.7 and 435psi Diaphragm material / Fill fluid (wetted parts) - 7th character AISI 316 L ss Silicone oil Hastelloy C276TM Silicone oil Hastelloy C276TM gold-plated Silicone oil AISI 316 L ss Inert fluid Hastelloy C276TM Inert fluid Hastelloy C276TM gold-plated Inert fluid AISI 316 L ss White oil (FDA) Hastelloy C276TM White oil (FDA) Ceramic No filling Process connection material (wetted parts) - 8th character AISI 316 L ss AISI 316 L ss AISI 316 L ss AISI 316 L ss AISI 316 L ss AISI 316 L ss Hastelloy C276TM Hastelloy C276TM Hastelloy C276TM Hastelloy C276TM Gasket - 9th character C F L U (Note 2) only for front bonded diaphragm (Note 2) (Note 2) (Notes 1, 2) only for front bonded diaphragm (Notes 1, 2) (Notes 1, 2) (Note 2) only for front bonded diaphragm (Note 2) (Note 3) NACE NACE NACE NACE NACE NACE NACE NACE NACE 1 /2in NPT female DIN EN837-1 G 1/2in B G 1/2in front bonded diaphragm 1 /2in NPT male DIN EN837-1 G 1/2in D For ball valve connection 1 /2in NPT female DIN EN837-1 G 1/2in B 1 /2in NPT male DIN EN837-1 G 1/2in D NACE NACE NACE NACE NACE NACE NACE NACE NACE NACE (Note 2) (Note 2) VitonTM (Notes 1, 3) Perfluoroelastomer (MWP=0.6MPa) (Note 3) Perbunan (Note 3) None (Note 2) h Housing material and electrical connection - 10 character Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) Aluminium alloy (Barrel version) AISI 316 L ss (Barrel version) AISI 316 L ss (Barrel version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) Aluminium alloy (DIN version) NACE NACE NACE 1 /2in NPT M20 x 1.5 (CM 20) Harting Han 8U connector Fieldbus connector 1 /2in NPT M20 x 1.5 (CM 20) M20 x 1.5 (CM 20) Harting Han 8U connector Fieldbus connector S K G A F E N Z J B P S T U V E D K Y 5 6 8 N A B E G S T J K W (Not available FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Not available FM, CSA) (Not available FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) (Note 4) (Not available ATEX EExd, FM, CSA) Output/Additional options - 11th character HART digital communication and 4 to 20mA HART digital communication and 4 to 20mA PROFIBUS PA PROFIBUS PA FOUNDATION Fieldbus FOUNDATION Fieldbus No additional options Options requested (to be ordered by "Additional ordering code") No additional options Options requested (to be ordered by "Additional ordering code") No additional options Options requested (to be ordered by "Additional ordering code") (Note (Note (Note (Note (Note (Note 5, 6) 5) 5, 6) 6) 5, 6) 6) H 1 P 2 F 3 17 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 ADDITIONAL ORDERING INFORMATION for model 265AS Add one or more 2-digit code(s) after the basic ordering information to select all required options XX XX XX XX XX XX XX XX XX XX XX Electrical certification ATEX Group II Category 1/2 GD - Intrinsic Safety EEx ia ATEX Group II Category 1/2 G - Flameproof EEx d (Note 2) ATEX Group II Category 3 GD - Type of protection "N" EEx nL energy limited Factory Mutual (FM) - Intrinsically Safe Factory Mutual (FM) - Explosion Proof (only with 1/2in NPT electrical connection and SS label) Canadian Standard Association - Intrinsically Safe (pending) Canadian Standard Association - Explosion Proof (Note 2) Integral LCD Digital LCD integral display Backlit digital LCD integral display Mounting bracket (shape and material) For pipe mounting AISI 316 L ss For wall mounting AISI 316 L ss Surge Surge/Transient Protector (Note 7) (Note 2) E1 E2 E3 EA EB ED EE L1 L2 B2 B4 S1 Operating manual German M1 Labels & tag language German in stainless steel (not available with DIN Electronic Housing code J, K, W) German and English plastic (not suitable for Factory Mutual - Explosion Proof) Additional tag plate In stainless steel T1 TA I1 Preparation procedure Oxygen service cleaning (only available with inert fill and for sensor code C, F Viton gasket - Pmax=21MPa/210bar/3045psi; Tmax=60 C/140 F) P1 Certificates Inspection certificate EN 10204-3.1.B of calibration Inspection certificate EN 10204-3.1.B of the cleanliness stage according to DIN 25410 Inspection certificate EN 10204-3.1.B of helium leakage test of the sensor module Inspection certificate EN 10204-3.1.B of the pressure test Certificate of compliance with the order EN 10204-2.1 of instrument design Germanischer Lloyd approval C1 C3 C4 C5 C6 C8 Material traceability Certificate of compliance with the order EN 10204-2.1 of process wetted parts Inspection certificate EN 10204-3.1.B of process wetted parts (small parts with certificate of compliance EN 10204) Test report EN 10204-2.2 of the pressure bearing and process wetted parts H1 H3 H4 Connector Fieldbus 7/8 (without mating female plug) Fieldbus M12x1 (without mating female plug) Harting Han 8U - straight entry Harting Han 8U - angle entry 18 (Notes 6, 8) (Notes 6, 8) (Notes 5, 8) (Notes 5, 9) U1 U2 U3 U4 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 Note 1: Suitable for oxygen service Note 2: Not available with Sensor code C, F Note 3: Not available with Sensor code L, U Note 4: Select type in additional ordering code Note 5: Not available with Electronic Housing code G, W Note 6: Not available with Electronic Housing code E, K Note 7: Not available with ATEX-EEx nL (code E3) or PROFIBUS PA / FOUNDATION Fieldbus (code 2 or 3) with Intrinsic Safety EEx i (code E1) or FM-Intrinsically Safe (code EA). Note 8: Not available with Electronic housing code T, S, A, B, J Note 9: Not available with Electronic housing code T, S, A, B, J, K TM Hastelloy is a Cabot Corporation trademark TM Viton is a Dupont de Nemour trademark Standard delivery items (can be differently specified by additional ordering code) - General purpose (no Ex design) - No meter/display, no mounting bracket, no surge protection - English manual and labels (stainless steel nameplate for Barrel housing code A, B, E, G, S, T; plastic nameplate for DIN housing code J, K, W) - Configuration with kPa and deg. C units - No test, inspection or material traceability certificates THE SELECTION OF SUITABLE WETTED PARTS AND FILLING FLUID FOR COMPATIBILITY WITH THE PROCESS MEDIA IS A CUSTOMER'S RESPONSIBILITY, IF NOT OTHERWISE NOTIFIED BEFORE MANUFACTURING. 19 2600T Pressure Transmitters Model 265GS, 265AS SS/265GS/AS_3 The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB has Sales & Customer Support expertise in over 100 countries worldwide (c) ABB 2004 ABB Ltd Howard Road, St. Neots Cambridgeshire, PE19 3EU UK Tel: +44(0)1480 475321 Fax: +44(0)1480 217948 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden Germany Tel: +49 (0) 551 905 534 Fax: +49 (0) 551 905 555 SS/265GS/AS_3 Printed in Italy (01.04) www.abb.com/instrumentation