Product Catalogue Relays with forcibly guided contacts Product Catalogue - Relays with forcibly guided contacts Edition 12/2014 Publisher: ELESTA GmbH, Bad Ragaz, Switzerland All rights reserved. This work and its parts are protected by copyright. Any use in other than legally authorized cases requires the prior written consent of the publisher. What started out in 1997 as the continuation of ELESTA AG`s traditional relay production with just 15 employees, became a globally operating innovation leader in the area of functional safety and relay technology. Now latest relay products and sensors are produced by over 250 employees. These products are often the centrepiece of safety circuits of machinery and equipment. Every day we encounter many of those products without noticing them. Thus ELESTA products guarantee safety when we use elevators, ride the train, at the hospital, but also when we celebrate stars on stage or when movie heroes fly on broomsticks through magical worlds. The success is homemade. ELESTA invests in R&D above average. This "think tank" develops products that often represent a pilot function. The close interaction of in-house process development and product development not only increases the production capacity. Under the provisions of lean management and the related design-to-efficiency highly innovative products are produced that are competitive on the world market. Despite automated production lines, the most important factor of our success are our employees. The enthusiasm of the staff for the products, the opportunity to actively participate in changes ensures the highest quality in all areas. An enormous number of suggestions for improvement (CIP) is evidence of the strong identification of employees with products and company. The lean strategy of ELESTA GmbH is deeply rooted and not just an instrument of continuous efficiency improvement, it is also the driving force behind the innovation in products and production processes. The leading role in lean management was highlighted not least by winning the Swiss-Lean-Award in 2012. Harald Forster Geschaftsfuhrer / CEO ELESTA GmbH ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 1 Product Overview Relays with forcibly guided contacts Relays Features SIS 2 SIS 2 SEN SIS 3 SIS 3 SEN Small dimensions Small dimensions Small dimensions Small dimensions High shock resistance High shock resistance High shock resistance High shock resistance Large excitation voltage Very large excitation voltage Large excitation voltage Very large excitation voltage Low coil power loss Very low coil power loss High switching High switching reliability reliability High switching Very low coil reliability power loss High switching reliability SIS 4 SIS 4 SEN SIS 6 SIS 6 SEN SIF 3 SIF 4 SIF 6 SGR 282 ZK Extremely flat Extremely flat Extremely flat Extrusioncoated coil design design design design suitLarge switch- Large switch- Large switchHigh shock High shock Large excita- Very large able for use in ing current ing current ing current resistance resistance excitation tion voltage ATEX areas range range range voltage Large excita- Very large Low coil High switching Possible Possible com- Possible excitation Very low coil tion voltage power loss reliability component ponent instal- component voltage power loss High switching High switching installation installation lation under High switching High switching reliability reliability under the under the the relay reliability reliability relay relay High shock resistance High shock resistance Very small dimensions Very small dimensions Number of Contacts 2 2 3 3 4 4 6 6 3 4 6 2/2 Contact Material AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi Type of Contact Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Single contact with notched crown Coil Voltage 3 VDC 60 VDC 3 VDC 60 VDC 3 VDC 110 VDC 3 VDC 60 VDC 3 VDC 110 VDC 3 VDC 60 VDC 3 VDC 110 VDC 3 VDC 60 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC Coil Capacity1 270 mW 200 mW 600 mW 400 mW 500 mW 330 mW 660 mW 440 mW 600 mW 700 mW 660 mW 700 mW Switching Current Range 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 6 A 3 mA - 10 A 3 mA - 8 A 3 mA - 8 A 4 mA - 8 A Test Voltage Open Contact 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff Test Voltage between Contacts 5000 Veff 5000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff 4000 Veff SIS312 Var 2) SIS312 Var 2) 2500 Veff 2500 Veff 4000 Veff 4000 Veff 4000 Veff 5000 Veff (SIS312) (SIS312) Test Voltage Coil/ Contact 2500 Veff Protection RT III RT III RT III RT III RT III RT III RT III RT III RT II RT II RT II RT II Dimensions (external) in mm L 29.2 W 16.6 H 16.5 L 29.2 W 16.6 H 16.5 L 29.2 W 16.6 H 16.5 L 29.2 W 16.6 H 16.5 L 48 W 16.6 H 16.5 L 48 B 16,6 H 16,5 L 48 B 16,6 H 16,5 L 48 B 16,6 H 16,5 L 33.7 W 29.4 H 10.9 L 41 W 29.4 H 10.9 L 53.6 W 33.5 H 10.9 L 30.2 W 12.7 H 25.6 Approvals UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV Options (see catalogue) 1 2500 Veff 2500 Veff 2500 Veff (SIS222, 2500 Veff - - - - - - - - Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page10 Page 11 Reference temperature 20C 2 3 2 2500 Veff (SIS222, Between left and right contact side Between control contacts ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 4 5 Page 29 Page 12 Page 13 Page 14 Between control and output contacts Between output contacts (c) Copyright 12/2014 Page 15 Product Overview Relays with forcibly guided contacts SGR 282 ZK Var SIM 2 SIM 3 SIM 4 SLR 4 SIR 4 SIR 4 SEN SIR 4 P SIR 6 SIR 6 SEN SIR 8 SIR 10 SIP 6 Extremely Powerful powerful High switching High switching High switching reliability reliability Small design High switching High switching High switching High switching reliability Wide coil Wide coil reliability For loads with reliability reliability Large switch- reliability working range working range For the highest a high surge ing current High switching High switching High switching High switching Low coil Contact Low coil loads during current range reliability reliability reliability reliability Contact Contact power loss assignment power loss 3-phase apassignment assignment High switching configurable High switching plications and Extremely Extremely Extremely Wide coil Wide coil configurable configurable reliability reliability DC loads high leakage high leakage high leakage working range working range and creepage and creepage and creepage Contact distances distances distances assignment configurable Extrusioncoated coil design suitable for use in ATEX areas Extrusioncoated coil design suitable for use in ATEX areas Extrusioncoated coil design suitable for use in ATEX areas Extrusioncoated coil design suitable for use in ATEX areas Powerful Powerful Powerful Small, horizontal design Small design Small design Extremely powerful Powerful Powerful Small design Small design Powerful 2 2 3 4 4 4 4 4 6 6 8 10 6 AgCuNi AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 AgSnO2 Crest contact Crest contact Crest contact Crest contact Crest contact Single contact Crest contact Crest contact Crest contact Crest contact Single contact Single contact with Crest notched contact crown 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 60 VDC 3 VDC 110 VDC 3 VDC 110 VDC 3 VDC 60 VDC 3 VDC 220 VDC 3 VDC 220 VDC 3 VDC 220 VDC 700 mW 500 mW 750 mW 1000 mW 600 mW 600 mW 360 mW 750 mW 750 mW 500 mW 1300 mW 1300 mW 1300 mW 4 mA - 8 A 10 mA - 8 A 10 mA - 8 A 10 mA - 8 A 10 mA 10 A 10 mA 10 A 10 mA 10 A 5 mA - 12 A 10 mA 10 A 10 mA 10 A 10 mA 10 A 10 mA 10 A 5 mA - 16 A 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 1500 Veff 4000 Veff 4000 Veff 2500 Veff 4000 Veff2 2500 Veff 4000 Veff2 4000 Veff3 4000 Veff4 5000 Veff5 2500 Veff3 5000 Veff4 4000 Veff5 2500 Veff3 5000 Veff4 4000 Veff5 2500 Veff3 5000 Veff4 4000 Veff5 2500 Veff3 5000 Veff4 4000 Veff5 2500 Veff3 5000 Veff4 4000 Veff5 4000 Veff 4000 Veff 2500 Veff3 5000 Veff4 4000 Veff5 5000 Veff 5000 Veff 5000 Veff 5000 Veff 2500 Veff 2500 Veff 2500 Veff 2500 Veff 2500 Veff 2500 Veff 5000 Veff 2500 Veff 2500 Veff RT II RT II RT II RT II RT II RT II RT II RT II RT II RT II RT II RT II RT II L 30.2 W 12.7 H 25.6 L 27.4 W 12.5 H 26.2 L 36.1 W 12.5 H 26.2 L 36.1 W 12.5 H 26.2 L 53.3 W 33.4 H 16.5 L 46.4 W 16 H 30.7 L 46.4 W 16 H 30.7 L 46.4 W 16 H 30.7 L 58.9 W 16 H 30.7 L 58.9 W 16 H 30.7 L 85.5 W 20 H 32 L 85.5 W 20 H 32 L 84.6 W 20 H 32 UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV UL, cUL, TUV Page 29 - Page 30 Page 30 - Page 31 Page 31 Page 31 Page 31 Page 31 - - - Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 3 SIS 2 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >10 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS112 1 NO / 1 NC - Small external dimensions - Nominal coil power 0,27 W - Holding coil power 0,08 W - For railway application (EN50155) on request 10000 0,2 1,6 0,4 1 1,6 2,3 10 16,6 11 3,3 3,3 6 O 1,3 [mm] 15 7,7 29,2 2,3 4,2 2,3 SIS112 A2 Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V/50 Hz/1 min Test voltage contact open 1500 V/50 Hz/1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current (other voltages on request) >10x106 operations 15 Hz typically 10 ms typically 3 ms typically 2 ms typically 15 ms NO > 17g NC > 7g NO > 7g NC > 2g Vibration resistance (10-200 Hz) Resistance to short circuiting contacts 1000 A SCPD 6 A gG/gL (pre-fuse) Ambient temperature -40C to +85 C Thermal Resistance 55 K/W Temperature limit for coil 120 C Weight ca. 18 g Mounting position any Type of protection RT III Solder bath temperature 270C/5 s Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C **without spark suppression 5 6 9 12 18 24 48 60 3,5 4,2 6,3 8,4 12,6 16,8 33,6 42,0 0,5 0,6 0,9 1,2 1,8 2,4 4,8 6,0 54,9 46,1 30,5 23,0 15,2 11,4 5,7 4,5 91 10% 130 10% 295 10% 520 10% 1180 10% 2100 10% 8350 13% 13100 15% AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) 2 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 250 Excitation Voltage Range 3,0 2,5 1 2,0 1,5 Tests, Regulations 1,0 Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories none available Sec. 5 250 VAC VDE 0106 UL 94 / V0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 100 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Product Key ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 200 1) Inductive load L/R 40 ms 2) Resistive load SIS 1 1 2 24VDC 4 3 4 5 6 7 8910 Load Limit Curve with Direct Current Additional Data Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms DC 1: 24V 500 Maximal switching characteristics(EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) 0,3 18,7 2,8 0,4 2,2 11 - 3,3 16,5 0,2 1,6 1000 12 A1 5000 Insulation Data 16,6 1,6 23 24 Dimensions 29,2 Contact Lifetime for NO Contact Operations x 1000 Relay Key Data (c) Copyright 12/2014 SIS 2 sensitive Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >10 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS112 1 NO / 1 NC - Small external dimensions - Nominal coil power 0,2 W - Holding coil power 0,04 W 10000 1,6 0,2 1,6 18,7 6 1 1,6 2,3 10 16,6 11 3,3 3,3 2,2 0,4 O 1,3 [mm] 15 7,7 29,2 2,3 4,2 2,3 A2 - Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA 3 3,3 4,5 5 6 9 12 24 48 60 2,25 2,47 3,37 3,75 4,50 6,75 9,00 18,00 36,00 45,00 0,3 0,33 0,45 0,5 0,6 0,9 1,2 2,4 4,8 6,0 66,6 60,6 44,5 40,0 33,3 22,2 16,6 8,3 4,1 3,3 Resistance in Ohm at 20 C Nominal voltage VDC (other voltages on request) 45 10% 54,4 10% 101 10% 125 10% 180 10% 405 10% 720 10% 2880 10% 11520 13% 18000 13% >10x106 operations 12 Hz typically 15 ms typically 5 ms typically 2 ms typically 15 ms NO > 17g NC > 7g NO > 7g NC > 2g Vibration resistance (10-200 Hz) Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40 C to +85 C Thermal Resistance 55 K / W Temperature limit for coil 120 C Weight ca. 18 g Mounting position any Type of protection RT III Solder bath temperature 270 C / 5 s AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 Schaltstrom (A) 1 2 3 4 5 6 7 8910 Load Limit Curve with Direct Current 6 4 3 2 Additional Data Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms AC 1:230V 100 Maximal switching characteristics(EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) 0,3 2,8 0,4 SIS112SEN DC 1: 24V 500 11 Insulation Data 3,3 16,5 0,2 1,6 5000 1000 12 A1 16,6 23 24 Dimensions 29,2 Contact Lifetime for NO Contact Schaltspiele x 1000 Relay Key Data 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 200 250 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 4,0 3,5 1 3,0 **without spark suppression 1 2,5 Tests, Regulations 2,0 Approvals 1,5 UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories 1,0 UB UN 2 2 0,5 0 -10 10 30 Ambient Temperaure C none available 50 70 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation Product Key SIS 1 1 2 24VDC SEN sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: Sec. 5 250 VAC VDE 0106 UL 94 / V0 +41 (0)81 303 54 00 +41 (0)81 303 54 01 No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. (c) Copyright 12/2014 5 SIS 3 Series Circuit Diagram (view on relay upper side) 12 A1 0,4 0,3 2 6 2,8 1 0,2 2,3 10 3,3 2,3 4,2 6,5 8,5 7,7 29,2 2,3 [mm] 3,3 16,6 11 O 1,3 11 SIS212 A2 - 0,2 16,5 6,5 12,2 3,3 2,2 0,4 1000 Insulation Data 16,6 0,2 2 29,2 25,2 5000 23 24 Dimensions 10000 33 34 Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Additional Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 9 12 18 24 48 60 110 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 0,5 0,9 1,2 1,8 2,4 4,8 6,0 11,0 120,0 66,6 50,0 33,3 25,0 12,5 10,0 5,4 41,5 10% 135 10% 240 10% 540 10% 960 10% 3840 10% 6000 13% 20150 15% Contact Lifetime for NO contacts >10x106 operations 15 Hz typically 10 ms typically 3 ms typically 2 ms typically 15 ms NO > 17g NC > 10g NO > 7g NC > 3g Vibration resistance (10-200 Hz) Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight ca. 20 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s **without spark suppression Operations x 1000 - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >8 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS212 2 NO / 1 NC - Small external dimensions - Nominal coil power 0,6 W - Holding coil power 0,18 W - For railway application (EN50155) on request DC 1: 24V 500 AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) 2 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) Tests, Regulations 250 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 2,0 1,0 Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories 1 Sec. 5 250 VAC VDE 0106 UL 94 / V0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 SIS 2 1 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 100 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Product Key ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 200 1,5 none available 6 3 4 5 6 7 8910 Maximal switching characteristics (DIN EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) Relay Key Data (c) Copyright 12/2014 SIS 3 sensitive Series Circuit Diagram (view on relay upper side) 12 A1 29,2 25,2 0,4 0,3 6 2,8 1 0,2 2,3 10 3,3 2,3 4,2 6,5 8,5 7,7 29,2 2,3 [mm] 3,3 16,6 11 O 1,3 11 SIS212SEN A2 - 0,2 16,5 6,5 12,2 3,3 2,2 0,4 1000 Insulation Data 16,6 2 0,2 2 5000 23 24 Dimensions 10000 33 34 Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance 5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact Data Additional Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 6 9 12 18 24 48 60 3,75 4,5 6,75 9,0 13,5 18,0 36,0 45,0 0,5 0,6 0,9 1,2 1,8 2,4 4,8 6,0 80,0 66,6 44,5 33,3 22,2 16,6 8,3 6,6 62,5 10% 90 10% 202 10% 360 10% 810 10% 1440 10% 5750 13% 9000 15% Contact Lifetime for NO Contacts Operations x 1000 - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >8 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS212 2 NO / 1 NC - Small external dimensions - Nominal coil power 0,4 W - Holding coil power 0,14 W - For railway application (EN50155) on request >10x106 operations 15 Hz typically 10 ms typically 3 ms typically 2 ms typically 15 ms NO > 17g NC > 10g NO > 7g NC > 3g Vibration resistance (10-200 Hz) Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight ca. 20 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s AC 1:230V 100 6 4 3 2 Product Key ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 200 250 60 80 100 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 1 2,0 0,5 UB UN 0 2 0 20 40 Ambient Temperature C 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available SIS 2 1 2 24VDC SEN 3 4 5 6 7 8910 Load Limit Curve with Direct Current 1,0 Options, Accessories 2 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each Tests, Regulations Sec. 5 250 VAC VDE 0106 UL 94 / V0 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) 1,5 UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements AC 15: 230V 50 **without spark suppression Approvals DC 1: 24V 500 Maximal switching characteristics (DIN EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) Relay Key Data sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 7 SIS 4 Series Circuit Diagram (view on relay upper side) 0,2 2,8 2,3 3,3 SIS312 KV2 0,3 2,8 0,4 0,2 16,5 0,2 48 13 18,7 5 7 O1,3 11 0,2 0,3 2,8 0,4 3,3 2,3 16,5 0,2 SIS312 2 2,3 10 8,5 13,7 48 4 13 15 8,7 5 2,3 2 6,5 6,5 18,7 12 2,3 O1,3 11 2,3 4 6,5 13 [mm] 4 6,5 6,5 15 13,7 10 O1,3 2,3 10 8,5 12 2,3 Contact Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current 13 14 SIS222 A2 A1 SIS312 12 A2 A1 11 SIS312 KV2 A2 Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10x106 operations 15 Hz typically 15 ms typically 5 ms typically 2 ms typically 15 ms NO > 10g NC > 10g NO > 10g NC > 4g Vibration resistance (10-200 Hz) Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight ca. 30 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 0,5 0,9 1,2 1,8 2,4 4,8 6,0 11,0 100 56,2 42,1 28,1 20,8 10,4 8,3 4,5 50 10% 160 10% 285 10% 640 10% 1150 10% 4600 10% 7200 13% 24200 15% DC 1: 24V 500 AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 5 250 VAC VDE 0106 UL 94 / V0 2 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 150 200 60 80 3,0 2,5 1 2,0 1,5 0,5 UB UN 0 2 0 20 40 Ambient Temperature C 100 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation Product Key SIS 3 1 2 24VDC KV2 Contact variant Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 250 Excitation Voltage Range No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 3 4 5 6 7 8910 Maximal switching characteristics (DIN EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 1,0 Tests, Regulations 5 9 12 18 24 48 60 110 1000 Additional Data **without spark suppression (other voltages on request) 8 21 - 1 2,3 16,5 0,2 16,7 11 3,3 2 6,5 0,3 22 5000 23 Insulation Data 16,6 0,4 11 10000 33 24 21 12 43 44 33 34 34 22 Dimensions SIS222 43 44 33 34 A1 48 43 44 Contact Lifetime for NO Contacts Operations x 1000 - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >8 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact Mounting: SIS312 3 NO / 1 NC SIS222 2 NO / 2 NC - Small external dimensions - Nominal coil power 0,5 W - Holding coil power 0,15 W - For railway application (EN50155) on request Current (A) Relay Key Data (c) Copyright 12/2014 SIS 4 sensitive Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >8 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact Mounting: SIS312 3 NO / 1 NC SIS222 2 NO / 2 NC - Small external dimensions - Nominal coil power 0,33 W - Holding coil power 0,08 W - For railway application (EN50155) on request 22 2,3 2,8 0,3 13 18,7 3,3 2,3 5 7 O1,3 11 3,3 0,2 SIS312 KV2 2 2,3 4 13 15 8,7 5 2,3 2 6,5 6,5 18,7 12 2,3 4 13 14 A2 A1 A1 12 A2 A1 SIS312 SEN 23 11 A2 SIS312 SEN KV2 6,5 6,5 15 Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 1000 13,7 2,3 Contact Data Contact material AgCuNi+0,2-0,4 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10x106 operations 15 Hz typically 20 ms typically 4 ms typically 2 ms typically 15 ms NO > 10g NC > 10g NO > 10g NC > 4g Vibration resistance (10-200 Hz) Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight ca. 30 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s **without spark suppression (other voltages on request) Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C 2,3 2,5 3,4 3,8 4,5 9,0 18,0 45,0 0,3 0,3 0,5 0,5 0,6 1,2 2,4 6,0 111 100 73,7 66,6 55,5 27,9 13,8 5,5 27 10% 33 10% 61 10% 75 10% 108 10% 430 10% 1730 10% 10800 10% AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 5 250 VAC VDE 0106 UL 94 / V0 2 3 4 5 6 7 8910 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each Load Limit Curve with Direct Current 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 150 200 250 Excitation Voltage Range 3,0 1 2,5 2,0 1,5 2 1,0 Tests, Regulations 3 3,3 4,5 5 6 12 24 60 DC 1: 24V 500 Maximal switching characteristics (DIN EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Additional Data O1,3 11 2,8 0,3 2,3 0,2 SIS312 48 16,5 0,2 [mm] 10 8,5 13,7 48 21 5000 Current (A) 2,3 10 O1,3 16,5 0,2 2,3 0,2 8,5 12 10 16,5 0,2 16,7 0,4 22 10000 33 - 1 2,8 0,3 11 3,3 0,4 0,4 11 43 Insulation Data 16,6 SIS222 4 6,5 13 24 21 12 44 33 34 34 SIS222 SEN 48 43 44 33 34 Dimensions 2 6,5 43 44 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data 0,5 UB UN 0 0 20 40 60 80 100 Ambient Temperature C 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available Product Key SIS 3 1 2 24VDC SEN KV2 ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: Contact Variant Sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 9 SIS 6 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >8 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS422 4 NO / 2 NC - Small external dimensions - Nominal coil power 0,66 W - Holding coil power 0,20 W - For railway application (EN50155) on request 64 54 32 48 10000 53 5000 1000 31 22 21 13 14 A1 63 43 44 Dimensions SIS422 A2 16,6 16,5 0,2 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data Insulation Data 0,3 2,8 0,4 3,3 2 6,5 6,5 10,2 8,5 5 7 2,3 10 11 O1,3 4 6,5 6,5 6,5 8,5 8,7 5 2,3 1 [mm] 2,3 Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 9 12 18 24 48 60 110 3,5 6,3 8,4 12,6 16,8 33,6 42,0 77,0 0,5 0,9 1,2 1,8 2,4 4,8 6,0 11,0 133 73,7 55,8 37,1 29,7 13,9 11,1 6,0 37,5 10% 122 10% 215 10% 485 10% 860 10% 3450 10% 5400 13% 18300 15% Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M >10 x 106 operations 15 Hz typically 15 ms typically 5 ms typically 2 ms typically 15 ms NO > 10g NC > 9g Vibration resistance NO > 10g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight ca. 35 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s **without spark suppression AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 5 250 VAC VDE 0106 UL 94 / V0 150 200 60 80 3,0 2,5 1 2,0 1,5 2 0 20 40 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation Product Key SIS 4 2 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 10 ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 100 Ambient Temperature C No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available 250 Excitation Voltage Range 0,5 UB UN 0 Approvals 3 4 5 6 7 8910 Load Limit Curve with Direct Current 1,0 Tests, Regulations 2 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each 4 contacts with 3 A each Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms AC 1:230V 100 Maximal switching characteristics (DIN EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) 0,2 - DC 1: 24V 500 (c) Copyright 12/2014 SIS 6 sensitive Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between control and load curcuit (leakage and creepage distances >8 mm) - EN50205 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS422 4 NO / 2 NC - Small external dimensions - Nominal coil power 0,44 W - Holding coil power 0,10 W - For railway application (EN50155) on request 64 54 32 48 1000 21 13 14 SIS422SEN A2 16,5 0,2 16,6 - 2 6,5 6,5 10,2 8,5 5 7 1 2,3 10 O1,3 4 6,5 6,5 6,5 8,5 8,7 5 [mm] 2,3 Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) >90000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 6 A Switching capacity range* 40 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 3 3,3 4,5 5 6 9 12 24 48 60 2,3 2,5 3,4 3,8 4,5 6,8 9,0 18,0 36,0 45,0 0,3 0,3 0,5 0,5 0,6 0,9 1,2 2,4 4,8 6,0 147 134 97,8 88,9 73,6 48,9 36,9 18,4 9,2 7,3 20,4 10% 24,5 10% 46 10% 56,2 10% 81,5 10% 184 10% 325 10% 1300 10% 5200 13% 8150 13% Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M >10 x 106 operations 15 Hz typically 20 ms typically 4 ms typically 2 ms typically 15 ms NO > 10g NC > 9g Vibration resistance NO > 10g (10-200 Hz) NC > 3g Resistance to short circuiting contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +85C Thermal Resistance 45 K / W Temperature limit for coil 120C Weight ca. 35 g Mounting position any Type of protection RT III Solder bath temperature 270C / 5 s **without spark suppression AC 1:230V 100 AC 15: 230V 50 DC 13: 24V 10 0,1 0,5 1 Switching Current (A) 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 5 250 VAC VDE 0106 UL 94 / V0 150 200 60 80 250 Excitation Voltage Range 3,0 2,5 2,0 1 1,5 0,5 UB UN 0 Approvals 3 4 5 6 7 8910 Load Limit Curve with Direct Current 2 1,0 Tests, Regulations 2 Maximal contact load at AC 1 with 230 V: 2 contacts with 6 A each 3 contacts with 4 A each 4 contacts with 3 A each Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms DC 1: 24V 500 Maximal switching characteristics (DIN EN60947-5-1) AC 1: 250 V / 6 A AC 15: 230 V / 3 A DC 1: 24 V / 6 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) 0,2 2,8 0,3 11 3,3 5000 Insulation Data 0,4 2,3 10000 53 31 22 A1 63 43 44 Dimensions Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data 0 20 40 100 Ambient Temperature C 1) Max. excitation voltage with contact load: 4 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available Product Key SIS 4 2 2 24VDC SEN Sensitive Coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 11 SIF 3 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5 mm) - EN50205 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact Mounting: SIF212 2 NO / 1 NC - Compact height: only 10,9 mm - Nominal coil power 0,60 W - Holding coil power 0,18 W - For railway application (EN50155) on request Dimensions 1 4,2 11 12 A1 A2 SIF212 15,8 10,5 6,4 18,2 3 1, [mm] * 20,8 at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data 5,3 3,1 4,8 21 23,2 24 * Do not drill if SMD arrangement ** Open breathing hole Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 12 ms typically 5 ms typically 1,5 ms typically 15 ms NO > 15g NC > 6g NO > 10g NC > 2g Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 10 A Switching capacity range* 40 mW to 2500 W(VA) Contact resitance (as delivered) 100 m / 6 V / 100 mA Vibration resistance (10-200 Hz) Resistance to short circuiting NO 1000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting NC 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 60 K / W Temperature limit for coil 120C Weight ca. 18 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s *Guided values **without spark suppression Standard coils for direct current Tests, Regulations (other voltages on request) Approvals Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C Contact Data 5 12 18 20 24 48 60 110 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 120,0 50,0 33,3 30,0 25,0 12,5 10,0 5,4 41,6 10% 240 10% 540 10% 665 10% 960 10% 3840 10% 6000 13% 20165 15% 12 1000 AC 1:230V 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each Load Limit Curve with Direct Current 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 150 200 250 60 80 100 Excitation Voltage Range 3,0 2,5 1 2,0 1,5 1,0 UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 6 250 VAC VDE 0106 UL 94 / V0 0,5 UB UN 0 2 0 20 40 Ambient Temperature C 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation none available Product Key SIF 2 1 2 24VDC ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: DC 1: 24V AC 15: 230V Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 10 A AC 15: 230 V / 5 A DC 1: 24 V / 10 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 Current (A) 2,2 4,2 * 7,6 3,1 7,5 7,5 1,8 * ** 4,2 3,1 23,2 1,2 3,1 10,9 3,1 2,9 4,2 1,5 15,4 O 23 - Double or reinforced insulation 29,4 0,5 * 10000 34 Insulation Data 33,7 5,1 7,6 1,5 33 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. (c) Copyright 12/2014 SIF 4 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5 mm) - EN50205 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact Mounting: SIF222 2 NO / 2 NC SIF312 3 NO / 1 NC - Compact height: only 10,9 mm - Nominal coil power 0,70 W - Holding coil power 0,21 W - For railway application (EN50155) on request 43 33 29,4 23,2 1,2 1 4,2 15,8 10,5 18,2 6,4 7,5 7,5 7,5 1,6 28,3 5,1 [mm] 12 A1 10000 A2 SIF312 Insulation Data - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M * Do not drill when SMD arrangement ** Open breathing hole Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 8 A AC1 2000 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 8 A Switching capacity range* 40 mW to 2000 W(VA) Contact resitance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 12 18 20 24 48 60 110 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 140,0 58,5 39,1 35,0 29,2 14,6 11,7 6,3 35,7 10% 205 10% 460 10% 570 10% 820 10% 3280 10% 5100 13% 17250 15% >10 x 106 operations 15 Hz typically 12 ms typically 5 ms typically 1,5 ms typically 15 ms NO > 15g NC > 5g NO > 10g NC > 2g Vibration resistance (10-200 Hz) Resistance to short circuiting NO 1000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting NC 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 60 K / W Temperature limit for coil 120C Weight ca. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression DC 1: 24V AC 15: 230V AC 1:230V 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 3 contacts with 6 A each Load Limit Curve with Direct Current Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms 1000 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 8 A AC 15: 230 V / 5 A DC 1: 24 V / 8 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 10 8 6 4 3 2 Current (A) 4,2 O1,3 7,6 3,1 3,1 4,8 2,9 4,2 3,1 15,4 21 23,2 4,2 3,1 3,1 2,2 10,9 5,1 1,6 0,5 1,5 A2 SIF222 41 37,8 1,5 7,6 24 11 12 A1 34 23 22 11 44 33 34 21 Dimensions 43 44 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 150 200 250 80 100 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 2,0 1 1,5 Tests, Regulations 1,0 Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories none available Sec. 6 250 VAC VDE 0106 UL 94 / V0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 1) Max. excitation voltage with contact load: 5 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Product Key SIF 3 1 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 13 SIF 6 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil and contacts (>5,5 mm) and contacts side by side (>5,5 mm) - EN50205 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact mounting: SIF422 4 NO / 2 NC - Compact height: only 10,9 mm - Nominal coil power 0,66 W - Holding coil power 0,20 W - For railway application (EN50155) on request 54 34 12 1,2 2,2 ** 1,5 4,1 3,1 3,3 1,6 11 21 44 22 A2 O1,3 * [mm] at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact oopen 1500 V / 50 Hz / 1 min Creepage resistance CTI 175 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data 3,1 1,5 - Double or reinforced insulation * Do not drill when SMD arrangement ** Open breathing hole Contact Data Contact material AgCuNi + 0,2 m Au Type of contact Single contact with notched crown Rated switching capacity 250 VAC 8 A AC1 2000 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 30 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 3 mA to 8 A Switching capacity range* 40 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 12 18 20 24 48 60 110 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 133,3 55,8 38,9 33,3 27,5 13,8 11,1 6,0 37,5 10% 215 10% 490 10% 600 10% 870 10% 3460 10% 5400 13% 18300 15% Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 20 ms typically 8 ms typically 1,5 ms typically 15 ms NO > 10g NC > 6g NO > 10g NC > 2g Vibration resistance (10-200 Hz) Resistance to short circuiting NO 1000 A SCPD 10 A gG / gL (pre-fuse) Resistance to short circuiting NC 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 47 K / W Temperature limit for coil 120C Weight ca. 35 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s AC 1:230V DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 3 contacts with 6 A each 4 contacts with 4,5 A each Load Limit Curve with Direct Current 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 200 250 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 Tests, Regulations 2,0 1 1,5 UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 6 250 VAC VDE 0106 UL 94 / V0 1,0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 100 1) Max. excitation voltage with contact load: 5 A 2) Min. excitation voltage (guaranteed values) without previous operation none available Product Key SIF 4 2 2 24VDC ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 5,0 Maximal switching characteristics (DIN EN 60947-5-1) AC 1: 250 V / 8 A AC 15: 230 V / 5 A DC 1: 24 V / 8 A DC 13: 24 V / 5 A / 0,1 Hz UL 508: B300 / R300 2,5 Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 14 AC 15: 230V 100 **without spark suppression Approvals DC 1: 24V 1000 Insulation Data 0,5 15,8 * * 33,5 30,4 1,6 15,4 7,5 7,5 1 15,8 * ** 43 Current (A) 3,1 10,9 2,9 15,8 33 10000 64 SIF422 53,6 47,4 4,1 3,1 63 A1 Dimensions 3,1 53 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data +41 (0)81 303 54 00 +41 (0)81 303 54 01 No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. (c) Copyright 12/2014 SGR 282 ZK Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances >14 mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5,5 mm) - EN50205 type B - 2 CO contacts with notched crown - Nominal coil power 0,7 W - Holding Power 0,21 W 10000 24 14 21 11 22 12 SGR282ZK Dimensions 30,2 12,7 A2 Contact Lifetime for NO Contacts Operations x 1000 Relay Key Data 1000 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 3,7 0,3 25,6 Insulation Data 5 5 15 2,6 7,5 O1,3 1 [mm] 2,5/2,54 Contact material AgCuNi + 0,2 m AU Type of contact notched crown Rated switching capacity 250 VAC 8 A AC1 2000 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 4 mA to 8 A Switching capacity range* 50 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 28 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 6 12 18 24 48 60 110 3,75 4,5 9,0 13,5 18,0 36,0 45,0 82,5 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 140,0 116,0 58,5 38,9 29,1 14,5 11,6 6,3 35,7 10% 51,4 10% 205 10% 462 10% 822 10% 3290 10% 5140 13% 17280 15% Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 12 ms typically 5 ms typically 4 ms typically 8 ms NO > 10g NC > 2,5g NO > 10g NC > 1,5g Vibration resistance (10-55 Hz) Resistance to short circuiting NO 1000 A SCPD 10 A gG / gL (pre-fuse) NC 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 50 K / W Temperature limit for coil 120C Weight ca. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Load Limit Curve with Direct Current 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 1 250 VAC VDE 0106 UL 94 / V1 Options, Accessories PCB socket, DIN rail socket Various modules Page 29 Page 29 150 200 250 60 80 100 Excitation Voltage Range 3,0 2,5 2,0 1 1,5 1,0 Tests, Regulations 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each Additional Data Contact Data 5,0 Maximal switching characteristics (DIN EN60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 6 A UL 508: C300 Current (A) 2,6 DC 1: 24V AC 1: 400V 100 A1 - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >14 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 550 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M AC 1:230V AC 15: 230V 0,5 UB UN 0 2 0 20 40 Ambient Temperature C 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Product Key SGR282ZK 24VDC Coil voltage Type designation ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 15 SGR 282 ZK Series Variants 1 NO / 1 NC Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances >14 mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5,5 mm) - EN50205 type A - 1 NO / 1 NC contact with notched crown - Nominal coil power 0,7 W - Holding Power 0,21 W VAR2 14 21 11 24 21 11 SGR282ZK 12,7 10000 1000 12 22 Dimensions 30,2 VAR1 A2 SGR282ZK A1 A2 Contact Lifetime for NO Contact Operations x 1000 Relay Key Data DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5 5 15 2,6 7,5 1 Var1 O1,3 2,5/2,54 Var2 [mm] Contact Data Contact material AgCuNi + 0,2 m AU Type of contact notched crown Rated switching capacity 250 VAC 8 A AC1 2000 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 4 mA to 8 A Switching capacity range* 50 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 28 V / 100 mA *Guided values Standard coils for direct current (other voltages on request) >10 x 106 operations 15 Hz typically 12 ms typically 5 ms typically 4 ms typically 8 ms NO > 10g NC > 2,5g NO > 10g NC > 1,5g Vibration resistance (10-55 Hz) Resistance to short circuiting NO 1000 A SCPD 10 A gG / gL (pre-fuse) NC 1000 A SCPD 6 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 50 K / W Temperature limit for coil 120C Weight ca. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C **without spark suppression 5 6 12 18 24 48 60 110 3,75 4,5 9,0 13,5 18,0 36,0 45,0 82,5 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 140,0 116,0 58,5 38,9 29,1 14,5 11,6 6,3 35,7 10% 51,4 10% 205 10% 462 10% 822 10% 3290 10% 5140 13% 17280 15% 8 6 4 3 2 Approvals 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 150 200 60 80 3,0 2,5 2,0 1 1,5 1,0 2 0 20 40 100 Ambient Temperature C UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 1 250 VAC VDE 0106 UL 94 / V1 Options, Accessories PCB socket, DIN rail socket Various modules 1) Max. excitation voltage with contact load: <4 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Page 29 Page 29 Product Key SGR282ZK VAR1 24VDC Coil voltage Contact variant Type designation 16 250 Excitation Voltage Range 0,5 UB UN 0 Tests, Regulations 10 Load Limit Curve with Direct Current Additional Data Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms 5,0 Maximal switching characteristics (DIN EN60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 6 A UL 508: C300 Current (A) 3,7 0,3 25,6 Insulation Data 2,6 DC 1: 24V AC 1: 400V 100 A1 - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >14 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 550 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M AC 1:230V AC 15: 230V ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 SIM 2 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided Contacts - Protective separation between coil and contacts (leakage and creepage distances >14 mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5,5 mm) - EN50205 type A - Contact mounting: SIM112 1 NO / 1 NC - Small external dimensions - Nominal coil power 0,5 W - Holding coil power 0,15 W SIM112 2,8 0,3 0,4 15,9 5 3,7 0,5 2,5 7,5 1 2,5 O 1,3 [mm] 15,9 5 A2 Insulation Data 26,2 2,9 2,5 7,5 2,5 2,8 Operations x 1000 11 24 A1 12,5 27,4 10000 12 23 Dimensions 3,7 Contact Data Contact material AgSnO2 + 0,2 m Type of contact Crest contact Rated switching capacity 250 VAC 8 A AC1 2000 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 20 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 8 A Switching capacity range* 60 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 28 V / 100 mA *Guided values Standard coils for direct current (other voltages on request) - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >14 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Mechanical endurance Switching frequency, mechanical Response time (NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 10 ms typically 3 ms typically 6 ms typically 12 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-200 Hz) NC > 1g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 55 K / W Temperature limit for coil 120C Weight ca. 20 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C 3,5 4,2 8,4 14,7 16,8 33,6 42,0 77,0 0,5 0,6 1,2 2,1 2,4 4,8 6,0 11,0 111,0 85,7 44,4 23,8 21,8 10,9 8,7 5,5 45 10% 70 10% 270 10% 880 10% 1100 10% 4400 13% 6850 15% 20000 15% Sec. 3 250 VAC VDE 0106 UL 94 / V1 Options, Accessories DC 1: 24V AC 15: 230V DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 10 Load Limit Curve with Direct Current 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 200 250 0 20 40 60 Ambient Temperature C 80 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 1 2,0 1,5 0,5 UB UN 0 Approvals AC 1:230V 100 1,0 Tests, Regulations UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements 1000 Maximal switching characteristics (DIN EN60947-5-1, Tab. C2) AC 1: 250 V / 8 A AC 15: 230 V / 3 A DC 1: 24 / 8 A DC 13: 24 V / 6 A / 0,1 Hz UL 508: C150 / R300 Additional Data **without spark suppression 5 6 12 21 24 48 60 110 Contact Lifetime NO-Contact Current (A) Relay Key Data 2 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available Product Key SIM 1 1 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 17 SIM 3 Series Circuit Diagram (view on relay upper side) Variant 1: Standard 12,5 0,3 0,4 15,9 5 5 5 0,5 2,5 2,4 O 1,3 7,5 1 2,5 Standard 2,8 15,9 5 5 5 2,4 2,5 7,5 2,5 O 1,3 KV2 2,8 15,9 5 5 5 12 23 11 11 24 SIM212 SIM212 A2 A1 A2 Insulation Data 26,2 2,9 2,5 7,5 2,5 2,8 44 12 A1 [mm] 2,4 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 8 A AC1 2000 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 20 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 8 A Switching capacity range* 60 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 6 12 21 24 48 60 110 3,75 4,5 9,0 15,75 18,0 36,0 45,0 82,5 0,5 0,6 1,2 2,1 2,4 4,8 6,0 11,0 151,0 125,0 63,1 35,5 30,0 15,4 12,5 6,8 33 10% 48 10% 190 10% 590 10% 800 10% 3100 10% 4800 13% 16000 15% 10000 43 34 44 Dimensions 36,1 Variant 2: KV2 33 43 Contact Lifetime NO-Contacts Operations x 1000 - PCB Relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances >14 mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5,5 mm) - EN50205 type A - Contact mounting: SIM212 2 NO / 1 NC - Small external dimensions - Nominal coil power 0,75 W - Holding coil power 0,21 W - For railway application (EN 50155) on request - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >14 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact oopen 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 10 ms typically 4 ms typically 6 ms typically 12 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-200 Hz) NC > 1g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 50 K / W Temperature limit for coil 120C Weight ca. 25 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression 1000 100 Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 3 250 VAC VDE 0106 UL 94 / V0 Options, Accessories PCB socket, DIN rail socket Page 30 AC 15: 230V DC 13: 24V 5,0 24VDC Load Limit Curve with Direct Current 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 150 200 250 60 80 100 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3.0 2.5 1 2.0 1.5 1.0 2 0 20 40 Ambient Temperature C 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. KV2 Contact Variant Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 18 ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each Product Key SIM 2 1 2 DC 1: 24V 10 0,1 0,5 1,0 Switching Current (A) 0.5 UB UN 0 Tests, Regulations AC 1:230V Maximal switching characteristics (DIN EN60947-5-1, Tab. C2) AC 1: 250 V / 8 A AC 15: 230 V / 3 A DC 1: 24 V / 8 A DC 13: 24 V / 6 A / 0,1 Hz UL 508: C150 / R300 Current (A) Relay Key Data (c) Copyright 12/2014 SIM 4 Series Circuit Diagram (view on relay upper side) 12,5 34 44 12 23 12 22 11 24 11 21 0,3 0,4 15,9 5 5 5 0,5 2,5 2,4 O 1,3 7,5 1 2,5 [mm] 15,9 5 5 5 2,4 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 8 A AC1 2000 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 20 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 8 A Switching capacity range* 60 mW to 2000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 6 12 21 24 48 60 110 3,75 4,5 9,0 15,75 18,0 36,0 45,0 82,5 0,5 0,6 1,2 2,1 2,4 4,8 6,0 11,0 181,8 166,0 85,7 46,6 40,0 20,8 16,6 9,6 27,5 10% 36 10% 140 10% 450 10% 600 10% 2300 10% 3600 13% 12000 15% 10000 SIM222 A2 A1 A2 Insulation Data 26,2 2,9 2,5 7,5 2,5 34 44 A1 36,1 2,8 33 43 SIM312 Dimensions 2,8 33 43 Contact Lifetime NO-Contacts Operations x 1000 - PCB Relay with forcibly guided contacts - Protective separation between coil and contacts (leakage and creepage distances >14 mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5,5 mm) - EN50205 type A - Contact mounting: SIM312 3 NO / 1 NC SIM222 2 NO / 2 NC - Small external dimensions - Nominal coil power 1 W - Holding coil power 0,29 W - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >5,5 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >14 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact oopen 1500 V / 50 Hz / 1 min Creepage resitance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M >10 x 106 operations 15 Hz typically 8 ms typically 4 ms typically 6 ms typically 12 ms NO > 10g NC > 2,5g Vibration resistance NO > 10g (10-200 Hz) NC > 1g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 50 K / W Temperature limit for coil 120C Weight ca. 25 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s 100 8 6 4 3 2 PCB socket, DIN rail socket Page 30 Product Key SIM 3 1 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 10 2 50 100 150 200 250 0 20 40 60 Ambient Temperature C 80 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 2,0 1,0 Options, Accessories 5,0 Load Limit Curve with Direct Current Tests, Regulations Sec. 3 250 VAC VDE 0106 UL 94 / V0 AC 15: 230V DC 13: 24V 1,5 UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements DC 1: 24V 10 0,1 0,5 1,0 Switching Current (A) **without spark suppression Approvals AC 1:230V Maximal contact load at AC 1 with 230 V: 2 contacts with 8 A each 3 contacts with 6 A each Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms 1000 Maximal switching characteristics (DIN EN60947-5-1, Tab. C2) AC 1: 250 V / 8 A AC 15: 230 V / 3 A DC 1: 24 V / 8 A DC 13: 24 V / 6 A / 0,1 Hz UL 508: C150 / R300 Current (A) Relay Key Data 0,5 UB UN 0 1 2 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 19 SLR 4 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts (>8 mm) as well as protective separation between the output contacts themselves (>10 mm) - EN50205 type A - Contact mounting: SLR312 3 NO / 1 NC SLR222 2 NO / 2 NC - Small external dimensions - Nominal coil power 0,6 W - Holding coil power 0,18 W - Coils for railway applications (EN 50155) on request 10000 42 41 12 11 23 24 12 11 23 24 SLR222 A2 A1 A2 [mm] 6,4 10,7 6,4 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Nominal voltage VDC Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C (other voltages on request) 5 6 12 18 24 48 60 110 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 121,0 100,0 50,0 33,3 25,2 12,6 10,0 5,5 41 10% 60 10% 240 10% 540 10% 950 10% 3800 10% 6000 13% 20000 15% - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M >10 x 106 operations 15 Hz typically 15 ms typically 4 ms typically 6 ms typically 12 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 1,5g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight ca. 30 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) Sec. 3 250 VAC VDE 0106 UL 94 / V0 Options, Accessories 5,0 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 3,0 2,5 2,0 1 1,5 2 0 20 40 60 Ambient Temperature C ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 24VDC +41 (0)81 303 54 00 +41 (0)81 303 54 01 80 100 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation 20 250 Excitation Voltage Range Product Key SLR 3 1 2 200 No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available 10 Load Limit Curve with Direct Current 0,5 UB UN 0 Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements AC 15: 230V 1,0 Tests, Regulations DC 1: 24V Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms AC 1:230V 1000 Maximal switching characteristics (DIN EN60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) 4 1 13,7 11,3 1,4 16,7 4 12,7 5,4 20,5 3 16,7 0,4 0,6 20,5 6,4 10,7 6,46,4 O 1,3 25 33 34 Insulation Data 33,4 Component Side 2,9 43 44 A1 0,3 2,9 16,5 3 2,9 33 34 SLR312 Dimensions 53,3 Contact Lifetime NO-Contacts Operations x 1000 Relay Key Data (c) Copyright 12/2014 SIR 4 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts (>10 mm) as well as protective separation between the output contacts themselves (>8 mm) - EN50205 type A - Contact mounting: SIR312 3 NO / 1 NC SIR222 2 NO / 2 NC - Small external dimensions - Nominal coil power 0,6 W - Holding coil power 0,18 W - Coils for railway applications (EN 50155) on request 33 43 34 44 33 43 34 44 12 23 12 22 11 24 11 21 SIR312 Contact Lifetime NO-Contacts 10000 Operations x 1000 Relay Key Data SIR222 Dimensions A2 A1 A2 2,9 0,7 30,7 Insulation Data 0,4 1,9 21 3 3 10 3 5 10,5 5 1,9 O 1,3 21 5 10,5 5 3 1 10 3 [mm] 3 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Drop-out voltage at 20 C Nominal current in mA Resistance in Ohm at 20 C 5 6 12 18 24 48 60 110 Min. pick-up voltage at 20 C Nominal voltage VDC (other voltages on request) 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 121,0 100,0 50,0 33,3 25,2 12,6 10,0 5,5 41 10% 60 10% 240 10% 540 10% 950 10% 3800 10% 6000 13% 20000 15% - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact oopen 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 15 ms typically 4 ms typically 6 ms typically 12 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 1,5g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 55 K / W Temperature limit for coil 120C Weight ca. 30 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) Sec. 3 250 VAC VDE 0106 UL 94 / V0 Options, Accessories 5,0 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each Load Limit Curve with Direct Current 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 200 250 Excitation Voltage Range 3,0 2,5 2,0 1 1,5 1,0 0,5 UB UN 0 Tests, Regulations DC 1: 24V AC 15: 230V Maximal switching characteristics (DIN EN60947-5-1, Tab. C2) AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) A1 16 46,4 AC 1:230V 1000 2 0 20 40 60 Ambient Temperature C 80 100 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Page 31 PCB socket Product Key SIR 3 1 2 24VDC Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 21 SIR 4 sensitive Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts (>10 mm) as well as protective seperation between the output contacts themselves (>8 mm) - EN50205 type A - Contact mounting: SIR312 3 NO / 1 NC SIR222 2 NO / 2 NC - Small external dimensions - Nominal coil power 0,36 W - Holding coil power 0,12 W - For railway application (EN50155) on request 33 43 34 44 10000 33 43 34 44 12 23 12 22 11 24 11 21 SIR312SEN Contact Lifetime NO-Contacts Operations x 1000 Relay Key Data SIR222SEN Dimensions 0,7 3 3 1 10 1,9 21 5 10,5 5 3 [mm] O 1,3 3 Contact Data Contact material AgSnO2 + 0,2 m Au Type of contact Crest Contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal current in mA 5 6 9 12 18 24 48 60 3,75 4,5 6,75 9,0 13,5 18,0 36,0 45,0 0,5 0,6 0,9 1,2 1,8 2,4 3,6 4,5 72,0 60,0 40,0 30,0 20,0 15,0 7,5 6,0 Resistance in Ohm at 20 C Nominal voltage VDC (other voltages on request) 69,4 10% 100 10% 225 10% 400 10% 900 10% 1600 10% 6400 13% 10000 15% A1 A2 Insulation Data 30,7 2,9 5 10,5 5 3 10 3 0,4 1,9 21 A2 - Basic insulation at 250 VAC Air and creepage distance >4 mm Test voltage 2500 V / 50 Hz / 1 min Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact oopen 1500 V / 50 Hz / 1 min Creepage resitance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resitance 16 ms >10 x 106 operations 15 Hz typically 18 ms typically 5 ms typically 6 ms typically 12 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 1,5g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight ca. 30 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Tests, Regulations Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 3 250 VAC VDE 0106 UL 94 / V0 Options, Accessories PCB socket 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 22 ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: Load Limit Curve with Direct Current 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 150 200 250 Excitation Voltage Range 3,0 2,5 1 2,0 1,5 1,0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 100 1) Max. excitation voltage with contact load: 6 A (2 contacts) 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Page 31 sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 10 Maximal contact load AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each Product Key SIR 3 1 2 24VDC SEN DC 1: 24V AC 15: 230V Maximal switching characteristics (DIN EN60947-5-1, Tab.C2) AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) A1 16 46,4 AC 1:230V 1000 (c) Copyright 12/2014 SIR 4 Power Series Circuit Diagram (view on relay upper side) 0,7 30,7 2,9 0,4 1,9 21 3 10 3 5 10,5 5 1,9 3 O 1,3 21 5 10,5 5 3 1 10 3 [mm] 3 Contact material AgSnO2 + 0,2 m Au Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 5 mA to 6 A Switching capacity range* 60 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Output Contacts Contact material AgSnO2 Rated switching capacity 250 VAC (440 VAC) 12 A AC1 3000 VA Electr. life AC 1(360 cycles / h) approx.250000 Inrush current max. 60 A for 20 ms Switching voltage range 5 to 250 VDC (480 VAC) Switching current range* 10 mA to 12 A Switching capacity range* 120 mW to 3000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 151,0 63,1 41,6 37,7 31,5 15,7 12,5 6,8 11 21 SIR312P A1 Operations x 1000 11 24 SIR222P A2 A1 DC 1: 24V 1000 A2 Insulation Data - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 15 ms typically 4 ms typically 6 ms typically 12 ms NO > 17g NC > 7g Vibration resistance NO > 10g (10-200 Hz) NC > 4,5g Resistance to short circuiting control contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Resistance to short circuiting output contacts 1000 A SCPD 16 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 55 K / W Temperature limit for coil 120C Weight ca. 32 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression DC 14: 24V 100 10 DC 13: 24V 1 Switching Current (A) 5 10 16 Contact Lifetime output contacts AC 10000 1000 AC 1: 400V AC 1: 230V AC 3: 230V 100 10 AC 15: 230V 1 Switching Current (A) AC 3: 400V 5 10 16 Maximal contact load AC 1 with 230 V: 2 contacts with 12 A each Load Limit Curve with Direct Current 12 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 0 50 100 Voltage (VDC) 150 200 250 80 100 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 Approvals 2,5 Resistance in Ohm at 20 C Nominal current in mA Min. pick-up voltage at 20 C Drop-out voltage at 20 C Nominal voltage VDC 0,5 1,2 1,8 2,0 2,4 4,8 6,0 11,0 12 22 Tests, Regulations Standard coils for direct current (other voltages on request) 3,5 8,4 12,6 14,0 16,8 33,6 42,0 77,0 12 23 Additional Data Control Contacts 5 12 18 20 24 48 60 110 33 43 34 44 Operations x 1000 16 46,4 33 43 34 44 Current (A) Dimensions Contact Lifetime output contacts DC 10000 Output contacts - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (>10 mm) and output contacts side by side (>8 mm) - EN50205 type A - Contact mounting: SIR312P Control contacts 1 NO / 1 NC Output contacts 2 NO SIR222P Control contacts 2 NC Output contacts 2 NO - Inrush current 60 A / continuous current 12 A - Nominal coil power 0,75 W - Holding coil power 0,23 W - For railway application (EN50155) on request Control contacts Relay Key Data 33 10% 190 10% 432 10% 530 10% 760 10% 3050 10% 4800 13% 16000 15% UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 3 250 VAC VDE 0106 UL 94 / V0 PCB socket Page 31 Product Key ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: Coil voltage Power version Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 1 1,5 1,0 Options, Accessories SIR 3 1 2 P 24VDC 2,0 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 1) Max. excitation voltage with contact load: 2 A control contacts, 10 A output contacts 2) Min. excitation voltage (guaranteed values) without previous operation (c) Copyright 12/2014 23 SIR 6 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (>10 mm) as well as protective separation between the output contacts themselves (>8 mm) - EN50205 type A - Contact mounting: SIR332 3 NO / 3 NC SIR422 4 NO / 2 NC SIR512 5 NO / 1 NC - Small external dimensions - Nominal coil power 0,75 W - Holding coil power 0,22 W - For railway application (EN50155) on request 16 0,4 21 5 10,5 5 7,5 5 3 3 10 1 3 3 10 3 O 1,3 [mm] 21 5 10,5 5 7,5 5 3 Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current 3,5 4,2 8,4 12,6 16,8 33,6 42,0 77,0 0,5 0,6 1,2 1,8 2,4 4,8 6,0 11,0 151,0 125,0 63,1 41,6 31,5 15,7 12,5 6,8 Resistance in Ohm at 20 C Nominal current in mA Drop-out voltage at 20 C Min. pick-up voltage at 20 C (other voltages on request) Nominal voltage VDC 54 64 32 42 33 42 33 43 31 41 34 41 34 44 12 23 12 23 12 23 11 24 11 24 11 24 SIR332 A1 SIR422 A2 A1 SIR512 A2 A1 A2 - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 33 10% 48 10% 190 10% 432 10% 760 10% 3050 10% 4800 13% 16000 15% Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms >10 x 106 operations 15 Hz typically 15 ms typically 4 ms typically 6 ms typically 12 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 2g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight ca. 35 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 3 250 VAC VDE 0106 UL 94 / V0 Options, Accessories Page 31 PCB socket ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: DC 1: 24V AC 15: 230V 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 10 Max. switching characteristics (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each 4 contacts with 7,3 A each 5 contacts with 6 A each Load Limit Curve with Direct Current 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 150 200 60 80 250 Excitation Voltage Range 3,0 2,5 2,0 1 1,0 Approvals SIR 4 2 2 24VDC AC 1:230V 1000 1,5 Tests, Regulations Product Key 24 10000 Additional Data Contacts Data 5 6 12 18 24 48 60 110 53 63 54 64 Current (A) 2,9 0,7 30,7 58,9 1,9 53 63 54 64 Insulation Data Dimensions 1,9 53 63 Contact Lifetime NO-Contacts Operations x 1000 Relay Key Data 0,5 UB UN 0 2 0 20 40 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 100 Ambient Temperature C (c) Copyright 12/2014 SIR 6 sensitive Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (>10 mm) as well as protective separation between the output contacts themselves (>8 mm) - EN50205 type A - Contact mounting: SIR332 3 NO / 3 NC SIR422 4 NO / 2 NC SIR512 5 NO / 1 NC - Small external dimensions - Nominal coil power 0,5 W - Holding coil power 0,18 W - For railway application (EN50155) on request 16 53 63 54 64 54 64 32 42 33 42 33 43 31 41 34 41 34 44 12 23 12 23 12 23 11 24 11 24 11 24 SIR332SEN SIR422SEN SIR512SEN A2 A1 A2 A1 A2 0,4 21 5 10,5 5 7,5 5 3 3 10 1 3 3 10 3 O 1,3 [mm] 21 5 10,5 5 7,5 5 3 - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact oopen 1500 V / 50 Hz / 1 min Creepage resitance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current Drop-out voltage at 20 C 3,75 4,5 6,75 9,0 13,5 18,0 36,0 45,0 0,5 0,6 0,9 1,2 1,8 2,4 3,6 4,5 100,0 83,3 56,2 41,6 27,7 20,8 10,4 8,3 Resistance in Ohm at 20 C Min. pick-up voltage at 20 C 5 6 9 12 18 24 48 60 Nominal current in mA Nominal voltage VDC (other voltages on request) 50 10% 72 10% 160 10% 288 10% 648 10% 1150 10% 4600 13% 7200 15% Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resitance 16 ms >10 x 106 operations 15 Hz typically 18 ms typically 5 ms typically 6 ms typically 12 ms NO > 10g NC > 6g Vibration resistance NO > 5g (10-200 Hz) NC > 2g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 55 K / W Temperature limit for coil 120C Weight ca. 35 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 10 Load Limit Curve with Direct Current 10 8 6 4 3 2 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 150 200 250 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 2,0 1,0 Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 3 250 VAC VDE 0106 UL 94 / V0 Options, Accessories Page 31 PCB socket 1 0,5 UB UN 0 2 0 20 40 60 Ambient Temperature C 80 100 1) Max. excitation voltage with contact load: 6 A (2 contacts) 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. Product Key ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 100 1,5 Tests, Regulations SIR 4 2 2 24VDC SEN DC 1: 24V AC 15: 230V Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each 4 contacts with 7,3 A each 5 contacts with 6 A each Additional Data Contacts Data AC 1:230V 1000 Max. switching characteristics (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) 2,9 0,7 30,7 58,9 1,9 53 63 54 64 Insulation Data Dimensions 1,9 10000 53 63 A1 Contact Lifetime NO-Contacts Operations x 1000 Relay Key Data Sensitive coil Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 25 SIR 8 Series Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil and output contacts (>10 mm) and contacts in one row (>8 mm) as well as protective separation between left and right contact side (>10 mm) - EN50205 type A - Contact mounting: SIR262 2 NO / 6 NC SIR352 3 NO / 5 NC SIR442 4 NO / 4 NC SIR532 5 NO / 3 NC SIR622 6 NO / 2 NC SIR712 7 NO / 1 NC - Small external dimensions - Nominal coil power 1,3 W - Holding coil power 0,39 W - For railway application (EN50155) on request 83 84 62 61 42 41 22 21 A1 SIR262 73 74 53 54 33 34 12 11 20 A1 A2 83 84 63 64 42 41 22 21 SIR532 73 74 52 51 32 31 12 11 83 84 62 61 42 41 23 24 A1 SIR352 73 74 53 54 32 34 12 11 A2 A1 A2 73 74 53 54 32 31 12 11 A1 83 84 63 64 42 41 22 21 SIR442 83 73 84 74 63 53 64 54 43 33 44 34 22 13 21 14 SIR622 A2 A1 A2 83 84 63 64 43 44 22 21 SIR712 A2 2,9 0,3 32 Insulation Data 3,75 12,5 3,75 2 0,5 1 5 7,5 57,5 5 7,5 5 3,1 3,75 12,5 3,75 0,4 37,9 O 1,3 [mm] 2 37,9 5 7,5 5 7,5 5 7,5 5 3,1 Contacts Data Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current 0,6 1,2 1,8 2,4 4,8 6,0 11,0 22,0 218,0 109,0 72,0 54,5 27,2 11,8 6,8 5,9 Resistance in Ohm at 20 C 4,2 8,4 12,6 16,8 33,6 42,0 77,0 154,0 Nominal current in mA Min. pick-up voltage at 20 C 6 12 18 24 48 60 110 220 Drop-out voltage at 20 C Nominal voltage VDC (other voltages on request) 27,5 10% 110 10% 250 10% 440 10% 1760 10% 2750 10% 9250 13% 37000 15% - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Operations x 1000 10000 73 74 52 51 32 31 12 11 Dimensions 85,5 Contact Lifetime NO-Contacts >10 x 106 operations 15 Hz typically 15 ms typically 4 ms typically 6 ms typically 12 ms NO > 10g NC > 6g Vibration resistance NO > 8g (10-200 Hz) NC > 2,5g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 40 K / W Temperature limit for coil 125C Weight ca. 60 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Tests, Regulations 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 3 250 VAC VDE 0106 UL 94 / V0 5,0 10 8 6 4 3 2 1 1 0,8 0,6 0,4 0,3 0,2 0,1 0 2 50 100 150 Voltage (VDC) ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 250 1) Inductive load L/R 40 ms 2) Resistive load Excitation Voltage Range 3,0 2,5 2,0 1,5 1 1,0 2 0 20 40 60 Ambient Temperature C 80 100 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation Product Key 26 200 No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available SIR 3 5 2 24VDC 10 Load Limit Curve with Direct Current 0,5 UB UN 0 Approvals DC 1: 24V AC 15: 230V Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each 4 contacts with 7,3 A each 5 contacts with 6,5 A each 6 contacts with 6 A each Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms AC 1:230V 1000 Max. switching characteristics (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) Relay Key Data Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 SIR 10 Series 93 94 72 71 52 51 32 31 12 11 A1 20 2,9 0,3 32 A1 0,5 0,4 1 25,4 5 7,5 5 7,5 5 7,5 5 7,5 5 3,1 3,75 12,5 3,75 3,75 2 3,75 12,5 O 1,3 2 [mm] 25,4 5 7,5 5 7,5 5 7,5 5 7,5 5 3,1 Contacts Data Contact material AgSnO2 + 0,2 m Au Type of contact Crest contact Rated switching capacity 250 VAC 10 A AC1 2500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 25 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 10 mA to 10 A Switching capacity range* 60 mW to 2500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values Standard coils for direct current 0,6 1,2 1,8 2,4 4,8 6,0 11,0 22,0 218,0 109,0 72,0 54,5 27,2 11,8 6,8 5,9 Resistance in Ohm at 20 C 4,2 8,4 12,6 16,8 33,6 42,0 77,0 154,0 Nominal current in mA Min. pick-up voltage at 20 C 6 12 18 24 48 60 110 220 Drop-out voltage at 20 C Nominal voltage VDC (other voltages on request) 27,5 10% 110 10% 250 10% 440 10% 1760 10% 2750 10% 9250 13% 37000 15% SIR282 93 94 73 74 53 54 32 31 12 11 Dimensions 85,5 103 93 104 94 82 72 81 71 62 52 61 51 42 32 41 31 22 12 21 11 A2 103 104 83 84 62 61 42 41 23 24 SIR642 A2 103 104 82 81 62 61 42 41 23 24 A1 SIR372 A2 93 94 73 74 53 54 32 31 12 11 A1 93 94 72 71 52 51 33 34 12 11 A1 103 93 104 94 82 73 81 74 62 52 61 51 42 32 41 31 23 12 24 11 SIR462 103 93 104 94 83 73 84 74 63 53 64 54 42 33 41 34 23 12 24 11 SIR732 A2 A1 A2 A1 103 104 83 84 62 61 42 41 23 24 SIR552 103 93 104 94 83 73 84 74 63 53 64 54 42 33 41 34 23 12 24 11 SIR822 A2 A1 Contact Lifetime NO-Contacts A2 103 104 83 84 63 64 43 44 23 24 SIR912 A2 Insulation Data - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M 10000 Operations x 1000 Circuit Diagram (view on relay upper side) - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (>8 mm) and output contacts in one row (>8 mm) as well as protective separation between left and right contact side (>10 mm) - EN50205 type A - Contact mounting: SIR282 2 NO / 8 NC SIR372 3 NO / 7 NC SIR462 4 NO / 6 NC SIR552 5 NO / 5 NC SIR642 6 NO / 4 NC SIR732 7 NO / 3 NC SIR822 8 NO / 2 NC SIR912 9 NO / 1 NC - Nominal coil power 1,3 W - Holding coil power 0,39 W - For railway application (EN50155) on request >10 x 106 operations 15 Hz typically 18 ms typically 5 ms typically 8 ms typically 12 ms NO > 10g NC > 6g Vibration resistance NO > 8g (10-200 Hz) NC > 2,5g Resistance to short circuiting contacts 1000 A SCPD 10 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal Resistance 40 K / W Temperature limit for coil 125C Weight ca. 60 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s **without spark suppression Tests, Regulations Approvals UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Options, Accessories Sec. 3 250 VAC VDE 0106 UL 94 / V0 DC 1: 24V AC 15: 230V 100 DC 13: 24V 10 0,1 0,5 1,0 Switching Current (A) 5,0 10 Maximal contact load at AC 1 with 230 V: 2 contacts with 10 A each 3 contacts with 8,4 A each 4 contacts with 7,3 A each 5 contacts with 6,5 A each 6 contacts with 6 A each 8 contacts with 5 A each 9 contacts with 4,2 A each Load Limit Curve with Direct Current 10 8 6 4 3 2 Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms AC 1: 230V 1000 Max. switching characteristics (DIN EN 60947-5-1, Tab. C2): AC 15: 230 V / 5 A DC 13: 24 V / 7,5 A / 0,1 Hz UL 508: C600 / R300 Current (A) Relay Key Data 1 0,8 0,6 0,4 0,3 0,2 1 2 0,1 50 100 0 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 150 200 250 Excitation Voltage Range 3,0 2,5 2,0 1,5 1 1,0 2 0,5 UB UN 0 0 20 40 60 Ambient Temperature C 80 100 1) Max. excitation voltage with contact load: 6 A 2) Min. excitation voltage (guaranteed values) without previous operation No heat accumulation due to intrinsic heating of other components. Continuous duty 100%. none available Product Key SIR 7 3 2 24VDC ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 27 SIP 6 Series Circuit Diagram (view on relay upper side) 14 1 3 [mm] 4,1 Control Contact Contact material AgSnO2 + 0,2 m Au Rated switching capacity 250 VAC 6 A AC1 1500 VA Electr. life AC 1(360 cycles / h) approx.100000 Inrush current max. 15 A for 20 ms Switching voltage range 5 to 250 VDC / VAC Switching current range* 5 mA to 6 A Switching capacity range* 60 mW to 1500 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA Output Contact Contact material AgSnO2 Rated switching capacity 250 VAC (440 VAC) 16 A AC1 4000 VA Electr. life AC 1(360 cycles / h) approx.250000 Inrush current max. 60 A for 20 ms Switching voltage range 5 to 250 VDC (480 VAC) Switching current range* 10 mA to 16 A Switching capacity range* 120 mW to 4000 W(VA) Contact resistance (as delivered) 100 m / 6 V / 100 mA *Guided values 0,6 1,2 1,8 2,4 4,8 6,0 11,0 22,0 218,0 109,0 72,0 54,5 27,2 21,8 11,8 5,9 43 44 44 33 34 34 12 23 11 24 12 22 11 21 SIP 512 SIP 422 A2 A1 A2 - Basic insulation at 250 VAC - Air and creepage distance >4 mm - Test voltage 2500 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >8 mm - Test voltage 4000 V / 50 Hz / 1 min - Double or reinforced insulation at 250 VAC - Air and creepage distance >10 mm - Test voltage 5000 V / 50 Hz / 1 min Test voltage contact open 1500 V / 50 Hz / 1 min Creepage resistance CTI 250 Pollution degree 2 Overvoltage category III Insulation resistance at Up 500 VDC >100 M Additional Data Mechanical endurance Switching frequency, mechanical Response time (all NO closed) Drop-out time** (all NC closed) Bounce time of NO contact Bounce time of NC contact Shock resistance 16 ms 27,5 10% 110 10% 248 10% 440 10% 1760 10% 2750 10% 9250 13% 37000 15% >10 x 106 operations 15 Hz typically 18 ms typically 5 ms typically 8 ms typically 12 ms NO > 10g NC > 8g Vibration resistance 10-200 Hz NO > 10g 10-50 Hz NC > 5g 50-200 Hz NC > 3,5g Resistance to short circuiting control contacts 1000 A SCPD 6 A gG / gL (pre-fuse) Resistance to short circuiting output contacts 1000 A SCPD 16 A gG / gL (pre-fuse) Ambient temperature -40C to +70C Thermal resistance 40 K / W Temperature limit for coil 125C Weight ca. 60 g Mounting position any Type of protection RT II Solder bath temperature 270C / 5 s DC 1: 24V DC 14: 24V 100 10 DC 13: 24V 1 5 Switching Current (A) 10 16 Contact Lifetime output contacts AC 10000 AC 3: 230V 1000 AC 1: 400V AC 3: 400V 100 AC 1: 230V AC 15: 230V 10 1 5 Switching Current (A) UL 508: A600 / R150 Maximal contact load at AC 1 with 230 V: 2 contacts with 16 A each 3 contacts with 12 A each 4 contacts with 10 A each 10 16 Load Limit Curve with Direct Current 16 8 4 2 1 0,8 0,4 1 2 0,2 0,1 0 50 100 150 200 0 20 40 60 Ambient Temperature C 80 Voltage (VDC) 1) Inductive load L/R 40 ms 2) Resistive load 250 Excitation Voltage Range 2,5 Approvals 2,0 UL File E188953 Insulation class IEC 60664-1 Protection class II Fire protection requirements Sec. 4 250 VAC VDE 0106 UL 94 / V0 1,5 1 1,0 2 0,5 UB UN 0 Options, Accessories none available Product Key ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: 1000 3,0 Tests, Regulations SIP 4 2 2 24VDC Operations x 1000 54 **without spark suppression Resistance in Ohm at 20 C Nominal current in mA Min. pick-up voltage at 20 C 4,2 8,4 12,6 16,8 33,6 42,0 77,0 154,0 Drop-out voltage at 20 C Nominal voltage VDC Standard coils for direct current (other voltages on request) 6 12 18 24 48 60 110 220 53 54 10000 Operations x 1000 33 64 Contact Lifetime output contacts DC Current (A) 3,75 3,75 6,5 14 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 6,5 0,5 32 2,9 12,5 0,4 2,1 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 4,1 0,5 3 O 1,3 3,75 12,5 3,75 43 63 64 Insulation Data 20 84,6 28 53 A1 Dimensions 2,1 63 Output Contacts - PCB Relay with forcibly guided contacts - Protective separation between coil/control contacts and output contacts (>8 mm) and output contacts in one row (>10 mm) - EN50205 type A - Contact mounting: SIP512 Control contacts 1 NO / 1 NC Output contacts 4 NO SIP422 Control contacts 2 NC Output contacts 4 NO - High switching power - Nominal coil power 1,3 W - Holding coil power 0,39 W - For railway application (EN50155) on request Control Contacts Relay Key Data Coil voltage Soldering tags Number of NC contacts Number of NO contacts Type designation +41 (0)81 303 54 00 +41 (0)81 303 54 01 100 1) Max. excitation voltage with contact load: control contacts 4 A, output contacts 12 A 2) Min. excitation voltage (guaranteed values) without previous operation (c) Copyright 12/2014 Relay Accessories for Series SGR 282 ZK PCB socket SRP-SGR2 DIN rail socket SRD-SGR2 Modules for SRD-SGR2 Socket data Socket data Module SRD-SGR2-M01 - With plastic hold down clip - Soldering tags for PCB - 2,5mm pinning - - For DIN rail socket SRD-SGR2 - Diode 6VDC to 230VDC (+ on terminal A1) A1 + With plastic grip and marking tag (1 pc) Screw terminals 2,5mm pinning Assembly on DIN rail 35mm or single-hole mounting with M3 screw A2 - Module SRD-SGR2-M02 - For DIN rail socket SRD-SGR2 - Diode with red LED, 6VDC to 24VDC (+ on terminal A1) Module SRD-SGR2-M03 - For DIN rail socket SRD-SGR2 - Diode with green LED, 6VDC to 24VDC (+ on terminal A1) A1 + Dimensions Dimensions 15 Modul SRD-SGR2-M05 - For DIN rail socket SRD-SGR2 - Green LED, 6VDC to 24VDC (+ on terminal A1) 12,7 6 12 22 COIL A1 + A2 A1 NC NO COM 24 14 21 15,5 11 60 10,8 31 O 1,5 37,5 A2 - 75 [mm] Technical data Rated current Rated voltage Test voltage coil/contacts Insulation class (IEC 60664-1) Creepage resistance Weight Ambient temperature Packing unit Approvals UL File - For DIN rail socket SRD-SGR2 - Red LED, 6VDC to 24VDC (+ on terminal A1) 24 4,8 3,2 A2 - Modul SRD-SGR2-M04 68,6 42,5 9,0 3 4,8 [mm] 2x8A 300VAC 4000Veff 250VAC CTI 250 approx. 4g -40C to +70C 100 pcs UL, cUL E113714 Technical data Rated current Rated voltage Test voltage coil/contacts Insulation class (IEC 60664-1) Creepage resistance Weight Ambient temperature Cross sections for connection with wires end sleeves for strands Maximales Drehmoment Packing unit Approvals UL File ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 2x8A 300VAC 2500Veff 250VAC CTI 250 approx. 40g -25C to +70C 2x2,5mm2 2x1,5mm2 0,8Nm 20 pcs UL, cUL E113714 (c) Copyright 12/2014 29 Relay Accessories for Series SIM 3 and SIM 4 Print socket SRP-SIM4 DIN rail socket SRD-SIM4 Socket data - With integrated retaining/ejector handels - Soldering tags for PCB - With integrated retaining/ejector handels - Screw terminals - Assembly on DIN rail 35mm or with 2xM3 screws Dimensions Dimensions 3,4 0,5 40,2 60 Socket data 31 11 A1 46,7 60 75,1 11,5 A2 24/21 44 23/22 43 33 [mm] 31 16 SA-SIM4 ELESTA 4,1 71 7,5 34 12 O1,5 5 5 5 15,9 [mm] SRD-SIM4 (SIM312...) SRD-SIM4 (SIM222...) 30 44 43 44 34 24 12 33 21 11 34 22 12 A1 A2 A1 A2 Technical data Technical data Rated current Rated voltage Test voltage coil/contacts Insulation class (IEC 60664-1) Creepage resistance Weight Ambient temperature Packing unit Approvals UL File 43 33 23 11 8A 250VAC 4000Veff 250VAC CTI 250 approx. 11g -25C to +70C 10 pcs UL, cUL E301947 Rated current Rated voltage Test voltage coil/contacts Insulation class (IEC 60664-1) Creepage resistance Weight Ambient temperature Cross sections for connection with wires end sleeves for strands Maximales Drehmoment Packing unit Approvals UL File ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 8A 250VAC 2500Veff 250VAC CTI 250 approx. 65g -25C to +70C 2x2,5mm2 2x1,5mm2 0,8Nm 10 pcs UL, cUL E238167 (c) Copyright 12/2014 Relay Accessories for Series SIR 4 and SIR 6 Print socket SRP-SIR4 Print socket SRP-SIR6 Socket data - PCB socket for SIR4 contacts - With integrated retaining/ejector handels - Soldering tags for PCB - PCB socket for SIR6 contacts - With integrated retaining/ejector handels - Soldering tags for PCB Dimensions Dimensions 10 [mm] 0,5 5 7,5 5 10,5 5 7,2 O1,5 10 [mm] 69,5 57 Technical data Rated current Rated voltage Test voltage coil/contacts Insulation class (IEC 60664-1) Creepage resistance Weight Ambient temperature Packing unit Approvals UL File 21 3,4 O 1,5 19,4 21 19,4 5 10,5 5 3,4 0,5 44,7 44,7 Socket data Technical data 8A 250VAC 4`000Veff 250VAC CTI 250 approx. 15g -25C to +70C 10 pcs UL, cUL E301947 Rated current Rated voltage Test voltage coil/contacts Insulation class (IEC 60664-1) Creepage resistance Weight Ambient temperature Packing unit Approvals UL File ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 8A 250VAC 4`000Veff 250VAC CTI 250 approx. 17g -25C to +70C 10 pcs UL, cUL E301947 (c) Copyright 12/2014 31 Notes 32 ELESTA GmbH, Heuteilstrasse 18, Fon: CH - 7310 Bad Ragaz, Switzerland Fax: +41 (0)81 303 54 00 +41 (0)81 303 54 01 (c) Copyright 12/2014 Switzerland: ELESTA GmbH Heuteilstrasse 18 CH-7310 Bad Ragaz Switzerland Phone: Fax: E-Mail: Internet: +41 (0) 81 303 54 00 +41 (0) 81 303 54 01 admin@elesta-gmbh.com www.elesta-gmbh.com Germany: ELESTA GmbH Sales Office Leipzig Unterer Haselberg 32 D-04683 Naunhof Germany Phone: Fax: E-Mail: Internet: +49 (0) 34293 47 38 18 +49 (0) 34293 45 99 88 m.meyer@elesta-gmbh.com www.elesta-gmbh.com ELESTA GmbH Sales Office Stuttgart Wiesbadener Platz 4 D-71672 Marbach Neckar Germany Phone: Fax: E-Mail: Internet: +49 (0) 7144 160 21 34 +49 (0) 7144 160 47 44 y.kihodu@elesta-gmbh.com www.elesta-gmbh.com Worldwide: see www.elesta-gmbh.com ELESTA GmbH en / 12_2014 Your ELESTA partner: