TCXO CCO 1000 Typical Applications Features SONET / SDH High frequency Hermetically Sealed Package Wide Temperature Range High Stability Standard Frequencies 622.08 MHz Note 1 Frequency stabilities Parameter vs. Operating temperature range Code I Frequency stability Operating temp range 03 04 05 06 2.0 ppm 1.0 ppm 1.0 ppm 0.5 ppm -20....+70 Parameter vs. Supply voltage change vs. Load change vs. Aging / year 0....+50C Value Condition < 0.1 ppm < 0.1 ppm < 1.0 ppm VS 5% Load 5% Frequency tuning Parameter Mechanical (No EFC) Option Value Condition E > 5.0 ppm external trimmer 22k Code III Value Condition 02 Sinewave 50 2% 0 dBm 3 dB @ 50 Code II Value Condition 12 12.0 V 5% < 70 mA RF output Parameter Signal Load Output power Supply voltage Parameter Supply voltage (VS) Current consumption Corning Frequency Control * Worldwide Data Book 2001 v1.0.2000-11-01 Corning Frequency Control Inc. * 100 Watts Street * Mt. Holly Springs, PA 17065 * Tel 1-717-486-3411 * Fax 1-717-486-5920 * www.corningfrequency.com Tele Quarz GmbH & Co. KG * Landstrasse * D-74924 Neckarbischofsheim, Germany * Tel +49-7268-801-0 * Fax +49-07268-801-281 * www.telequarz.de 1/2 TCXO CCO 1000 Additional parameters Parameter Value Phase Noise Condition <- 50 dBc/Hz <-75 dBc/Hz <-95 dBc/Hz <-100 dBc/Hz <-105 dBc/Hz <-110 dBc/Hz < 23 g -30 ... +80C -55 ... +105C Weight Operable temperature range Storage temperature range Processing & Packing 10 100 1 10 100 1 Hz Hz kHz kHz kHz MHz Note 2 handling&processing note Enclosure Type G134 Drawing 36,1max. 25,4 0,2 19,4max. 5 4,5min. 1 0,8max. 6 2 27,2max. 4 0,2 7 17,8 3 0,5 15,240,5 17,78 o0,8 all units in mm Pin Connections Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Ordering Code Model Example: Order: Notes 1 2 CC0300 CCO300 trimmer,sl trimmer, cw Supply Voltage (Vs) I.C. GND, case GND, case RF output Option Frequency tuning E Code I Frequency Stability 03. Code II Supply Voltage 12. Code III RF Output 02. Frequency 622M08000 other frequencies: (300 MHz to 1.3GHz) on request Typical values @ 622.08 MHz Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25C) Subject to technical modification; Not all options are available at all Frequencies Corning Frequency Control * Worldwide Data Book 2001 v1.0.2000-11-01 Corning Frequency Control Inc. * 100 Watts Street * Mt. Holly Springs, PA 17065 * Tel 1-717-486-3411 * Fax 1-717-486-5920 * www.corningfrequency.com Tele Quarz GmbH & Co. KG * Landstrasse * D-74924 Neckarbischofsheim, Germany * Tel +49-7268-801-0 * Fax +49-07268-801-281 * www.telequarz.de 2/2