ID Number: 40103 NI5-M12-Y1X-H1141 Inductive Sensor Features M12x1 threaded barrel Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NAMUR) M12 x 1 male connector ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1 Wiring diagram Type NI5-M12-Y1X-H1141 Ident. no. 40103 Rated switching distance 5mm Mounting conditions Non-flush Secured operating distance (0.81xSn)mm Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy 2% of full scale Temperature drift 10 % Hysteresis 1...10% Ambient temperature -25...+70C Output function 2-wire, NAMUR Switching frequency 2kHz Voltage Nom.8.2VDC Non-actuated current consumption 2.1mA Actuated current consumption 1.2mA Approval acc. to KEMA 02 ATEX 1090X Internal capacitance (Ci)/inductance (Li) 150 nF/150 H Device marking E II 1 G Ex ia IIC T6 Ga/II 1 D Ex ia IIIC T115 C Da Functional principle Inductive sensors detect metal objects contactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil. (max. Ui = 20 V, Ii = 20 mA, Pi = 200 mW) Design Threaded barrel,M12 x 1 Dimensions 52mm Housing material Metal, CuZn, Chrome-plated Active area material Plastic, PA12-GF30 TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com NI5-M12-Y1X-H1141| 05/27/2020 11-55 | technical changes reserved Technical data 1|4 Technical data Max. tightening torque housing nut 10Nm Electrical connection Connector,M12 x 1 Vibration resistance 55Hz (1 mm) Shock resistance 30g (11 ms) Protection class IP67 MTTF 6198years acc. to SN 29500 (Ed. 99) 40 C Switching state LED,Yellow Mounting instructions Mounting instructions/Description Distance D 3xB Distance W 3 x Sn Distance T 3xB Distance S 1.5 x B Distance G 6 x Sn Distance N 2 x Sn NI5-M12-Y1X-H1141| 05/27/2020 11-55 | technical changes reserved Diameter active area O12mm B TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|4 Accessories 7560003 IMX12-DI01-2S-2T-0/24VDC 2-channel isolating switching amplifier with M12x1 males, for peripheral use, IP67, zones 2/22, input circuits II(1) Ex ia, PNP transistor output NO QM-12 6945101 BST-12B 6947212 Quick-mount bracket with dead-stop; material: Chrome-plated brass. Male thread M16 x 1. Note: The switching distance of the proximity switches may change when using quick-mount brackets. MW12 6945003 7580020 Isolating switching amplifier, 2channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/ NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply Mounting clamp for threaded barrel sensors, with dead-stop; material: PA6 BSS-12 6901321 Mounting bracket for threaded barrel sensors; material: Stainless steel A2 1.4301 (AISI 304) Mounting clamp for smooth and threaded barrel sensors; material: Polypropylene Wiring accessories Dimension drawing Type Ident. no. RKC4.221T-2/TEB 6628420 Connection cable, female M12, straight, 2-pin, cable length: 2 m, sheath material: PVC, black; cULus approval; other cable lengths and qualities available, see www.turck.com WKC4.221T-2/TEB 6628427 Connection cable, M12 female connector, angled, 2-pin, cable length: 2m, jacket material: PVC, black; cULus approval; other cable lengths and qualities available, see www.turck.com TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com NI5-M12-Y1X-H1141| 05/27/2020 11-55 | technical changes reserved IMC-DI-22EX-PNO/24VDC 3|4 Operating Instructions Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012.Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508.In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) E II 1 G and Ex ia IIC T6 Ga acc. to EN60079-0 and -26 and E II 1 D Ex ia IIIC T115C Da acc. to EN60079-0 Local admissible ambient temperature -25...+70 C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.Please verify that the classification and the marking on the device comply with the actual application conditions. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device.If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields.The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com NI5-M12-Y1X-H1141| 05/27/2020 11-55 | technical changes reserved This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values.After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14).Attention! When used in safety systems, all content of the security manual must be observed. 4|4