Temperature Compensated Directional Power Detector
10 - 30 GHz
Rev. V1
MACP-010573
1
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0018081
Ordering Information1,2
MACP-010573-TR1000 1000 Part Reel
MACP-010573-001SMB Sample Board
1. Reference Application Note M513 for reel size information.
2. All sample boards include 5 loose parts.
Functional Schematic
Pin Configuration3
1 RFIN RF Input
2 N/C No Connection3
3 VBIAS Bias Voltage
4 VDET Detector Voltage
5 N/C No Connection3
6 RFOUT RF Output
7 GND Ground
3. Pins 2 and 5 are not connected internally and should not be
used for grounding. Package has exposed bottom metal pad-
dle (Pin 7) which should be connected to the circuit ground.
The parasitic inductance introduced by this connection should
be as small as possible.
Features
Integrated Directional Coupler
Low Insertion Loss: 0.40 dB @ 20 GHz
Min. detectable power: -18 dBm @ 20 GHz
Built-In Temperature Compensation
Lead-Free 1.5 x 1.2 mm 6-Lead TDFN Plastic
Package
Halogen-Free GreenMold Compound
RoHS* Compliant and 260°C Reflow Compatible
Description
The MACP-010573 belongs to a series of small,
easy-to-use, broadband, directional detectors. With
integrated low loss directional couplers and built-in
temperature compensation circuits, these detectors
provide an easy way to monitor the power of a signal
travelling in a specific direction along a transmission
line. Detectors are housed in a miniature, surface
mount, lead less plastic package. They require a
small amount of bias for proper performance. The
total bias current is less than 0.5 mA.
Typical applications include power monitoring and
leveling in Point-to-Point radios, IMS, Radar, VSAT,
EW, and Aerospace & Defense systems.
The surface mount package is small yet can be
handled and placed with standard pick and place
assembly equipment. Detectors are fabricated on a
well established GaAs process featuring full
passivation for performance and reliability.
* Restrictions on Hazardous Substances, European Union Directive 2011/65/EU.
RFIN
N/C
VBIAS VDET
N/C Detector
Engine
3
2
1 6
5
4
7
RFOUT
Termination
Directional Coupler
7
GND
Temperature Compensated Directional Power Detector
10 - 30 GHz
Rev. V1
MACP-010573
2
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0018081
Electrical Specifications:
Freq. = 20 GHz, TA = 25°C, VB = +3.2 V, Z0 = 50 Ω (unless otherwise specified)
Insertion Loss dB
0.15
0.40
0.90
10 GHz
20 GHz
30 GHz
Detect Voltage mV
240
495
745
10 dBm applied to Input
10 GHz
20 GHz
30 GHz
Directivity dB
16.5
13.0
11.5
Into 50 Ω load
10 GHz
20 GHz
30 GHz
Sensitivity dBm
-13
-18
-21
Minimum recommended power level
10 GHz
20 GHz
30 GHz
Maximum Power dBm 30
Maximum recommended power level
10 - 30 GHz
Input Return Loss dB 15 10 - 30 GHz
Output Return Loss dB 18 10 - 30 GHz
DC Offset mV 50 100 150 Detect voltage with no RF input power
Bias Current mA 0.3 0.35 V Bias = 3.2 V
Absolute Maximum Ratings4,5
Input Power 40 dBm
Operating Voltage 8 V
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
4. Exceeding any one or combination of these limits may cause
permanent damage to this device.
5. MACOM does not recommend sustained operation near these
survivability limits.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive to
electrostatic discharge (ESD) and can be damaged
by static electricity. Proper ESD control techniques
should be used when handling these HBM Class 0A
devices.
Temperature Compensated Directional Power Detector
10 - 30 GHz
Rev. V1
MACP-010573
3
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0018081
Recommended PCB Configuration
Application Information
The MACP-010573 is designed to deliver high
performance and to be easy to use.
No external components are needed. The RF
connections required by the MACP-010573 are
shown in a schematic below.
Pin 1 should be connected to the RF input signal.
Pin 6 is the RF output. The third required connection
is that to the RF ground. The exposed metal paddle
on the back of the package must be connected to
the RF ground of the board housing the detector.
This can be accomplished by using conductive via
holes. It is important to ensure that the parasitic
inductance associated with the connection between
the detector and the RF ground is as small as
possible. The RF ground also provides the return
path for the DC bias current.
DC Bias
The MACP-010573 operates with a positive 3.2 V
bias applied to pin 3. The output voltage is available
on pin 4.
Evaluation Board
MACOM will supply an evaluation board and loose
samples upon qualified request. The kit consists of a
PCB and SMA connectors. MACOM suggests a
Rogers 4350 dielectric of 0.008” (0.20 mm) with ½
ounce copper. Proper grounding is always
important, we suggest 8 mil (0.20 mm) vias placed
generously underneath the part.
RFIN
(Pin 1)
RFOUT
(Pin 6)
MACP-010573
Temperature Compensated Directional Power Detector
10 - 30 GHz
Rev. V1
MACP-010573
4
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0018081
Typical Performance Curves:
Directivity
Detect Voltage vs. Input Power
Input Return Loss
Temperature Compensation Accuracy
Output Return Loss
Insertion Loss
0
5
10
15
20
25
10 15 20 25 30
+25°C
-40°C
+85°C
Directivity (dB)
Frequency (GHz)
-10
0
10
20
30
-5 0 5 10 15 20
10 GHz
20 GHz
30 GHz
Total Percentage Error (%)
Input Power (dBm)
0
1
2
3
4
-10 0 10 20 30
10 GHz
20 GHz
30 GHz
VDET (V)
Input Power (dBm)
-1
-0.8
-0.6
-0.4
-0.2
0
0 5 10 15 20 25 30
+25°C
-40C
+85C
S21 (dB)
Frequency (GHz)
-60
-50
-40
-30
-20
-10
0
0 5 10 15 20 25 30
+25°C
-40°C
+85°C
S22 (dB)
Frequency (GHz)
-60
-50
-40
-30
-20
-10
0
0 5 10 15 20 25 30
+25°C
-40°C
+85°C
S11 (dB)
Frequency (GHz)
Temperature Compensated Directional Power Detector
10 - 30 GHz
Rev. V1
MACP-010573
5
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0018081
Lead-Free 1.5 x 1.2 mm 6-Lead TDFN
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Plating is 100% matte tin over copper.
All dimensions are in inches/mm.
Temperature Compensated Directional Power Detector
10 - 30 GHz
Rev. V1
MACP-010573
6
MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
DC-0018081
MACOM Technology Solutions Inc. All rights reserved.
Information in this document is provided in connection with MACOM Technology Solutions Inc ("MACOM")
products. These materials are provided by MACOM as a service to its customers and may be used for
informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or
in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM
assumes no responsibility for errors or omissions in these materials. MACOM may make changes to spec-
ifications and product descriptions at any time, without notice. MACOM makes no commitment to update the in-
formation and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future chang-
es to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to
any intellectual property rights is granted by this document.
THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR
INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR
OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY
OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN
THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS,
WHICH MAY RESULT FROM THE USE OF THESE MATERIALS.
MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM
customers using or selling MACOM products for use in such applications do so at their own risk and agree to
fully indemnify MACOM for any damages resulting from such improper use or sale.