Inductive sensors IWRM 18I97T4/S14 Inductive linear sensors dimension drawing 60 45 M18 x 1 SW 24 M12 x 1 general data photo mounting type quasi-flush special type Outdoor measuring distance Sd 0 ... 8 mm resolution repeat accuracy < 0,005 mm (stat.) < 0,01 mm (dynam.) < 0,015 mm linearity error 400 m temperature drift 10 % (Full Scale) electrical data response time (factory characteristic) < 2 ms voltage supply range +Vs 15 ... 30 VDC current consumption max. (no load) 40 mA output circuit current output output signal 4 ... 20 mA load resistance +Vs min. < 330 Ohm load resistance +Vs max. < 1000 Ohm short circuit protection yes reverse polarity protection yes connection diagram IWRM ~ ~ ~ BN (1) +VS WH/BK (2/4) BU(3) output Z 0V mechanical data cylindrical threaded material (sensing face) PBT housing material brass nickel plated dimension 18 mm housing length 60 mm connection types connector M12 installation drawing 8 4 0,2 type ambient conditions operating temperature -40 ... +70 C protection class IP 67 www.baumer.com 5/9/2012