CSH Series 25W/50W/100W/150W CSJ Series 10W/15W CSH Series 25W, 50W, 100W, 150W CSJ Series 10W, 15W SINGLE OUTPUT FEATURES * * * * * * Similar printed circuit board (PCB) and open frame structure for low cost Wide range of models (25 W to 150 W) to meet any need Resonant topology design for high efficiency and low noise (FCC class B) Proprietary SANKEN power hybrid IC STR-Z makes them small and light Complies with UL and CSA safety standards (pending approval) The low-capacity CSJ Series is also available (Ringing Choke Converter (RCC) type design, 10 W and 15 W models) * CSJ series meet FCC class B standard 1 CSH Series 25W/50W/100W/150W CSJ Series 10W/15W 2 CSH Series 25W/50W/100W/150W CSJ Series 10W/15W Environmental Additional Functions Other Output Input Rating Item Conditions Rated Input Voltage Input Voltage Range Input Current Rated input/output conditions Rated Frequency Frequency Range Efficiency (typ) Rated input/output conditions Inrush Current (see Note 1) Rated input/output conditions Rated Output Voltage Adjustable Output Voltage Range (see Note 5-a, b) Rated Output Current Adjustable Output Current Range Maximum Output Power Ripple Noise (mVp-p) (see Notes 2, 3) Rated input/output conditions Constant Voltage Accuracy (see Notes 4, 5-a, b) Leakage Current Rated input/output conditions Startup Time Rated input/output conditions Output Holdup Time Rated input/output conditions Over Current Protection (see Note 7) Over Voltage Protection (see Note 7) Remote Sensing Remote On/Off Control Display Operating Temperature Storage Temperature Operating Humidity Storage Humidity Cooling Requirements Vibration Resistance Vibration Frequency Test Duration Acceleration Vibration Direction Vibration Duration Shock Resistance Applicable Structural Standards Specifications Insulation Installation Conditions Insulation Withstand Voltage (see Note 6) Insulation Resistance (see Note 6) External Appearance Size (dimensions in mm) Weight Safety Standards EMI Standards Between Input and Output Between Input and Frame Between Output and Frame Between Input and Output Between Input and Frame Between Output and Frame 25W CSH 025-05 CSH 025-12 CSH 025-15 CSH 025-24 100-120V AC 85 to 132V AC 0.6/0.5A (typ) 50/60 Hz 47 to 440 Hz 80% 83% 84% 86% 30 A (max) +5V +12V +15V +24V Rated voltage 10% 5A 2.1A 1.7A 1.1A 0 to 100% 25W 25.2W 25.5W 26.4W 80mVp-p 100mVp-p 100mVp-p 100mVp-p 3% 0.5mA (max) 400ms (typ) 16ms (min) Detection above 105% of rated current (output cutoff) Detection above 115% of rated voltage (output cutoff) Not provided Not provided Not provided -10 to +60C (70% load at -10C, 60C) -25 to +85C 30 to 90% (no condensation) 30 to 90% (no condensation) Natural air cooling 10 to 55 Hz 3 minutes 2G X, Y, and Z directions One hour in each direction 10 G With the unit resting on a smooth-surfaced wooden plank, at least 10 mm thick, each side of the unit is raised 50 mm and allowed to fall freely. This is performed three times for each of the four sides. Derating is necessary depending on the installation conditions. Refer to (1) below. 2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less) 500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less) 100 M (measured with 500 V DC Megger) Open frame 115 x 50 (or less) x 23 (W x D x H) about 85 g Designed to meet UL 1950 / Designed to meet CSA C22.2 No. 234 Level 3 / Designed to comply with the Electrical Appliance and Materials Control Law Designed to meet FCC Class B (100 to 120 V AC) / Designed to meet VCCI Class 2 Note 1: Note 2: More current may flow at restart. (Power thermistor type) Ripple noise is measured at a point 5 cm from the output connector, with a 63 V 47 F electrolytic capacitor attached at that point. Constant voltage accuracy is measured at the output connector. Note 3: Ripple noise is measured with a 100 MHz oscilloscope, using a 1:1 probe. Note 4: Constant voltage accuracy is the output voltage accuracy with a static input voltage over the range of 85 to 132 V AC, with a static load over the range of 0 to 100%, time drift of 10 minutes to 8 hours, over an ambient temperature range of -10 to 60C. Note 5: a) When varying the output voltage, the unit may be used in a range such that the output does not exceed the rated maximum output voltage or rated current. b) When adjusting downwards with a light load, the output voltage may rise and exceed the constant voltage accuracy specification. Note 6: Insulation specifications are for normal temperature and humidity. Note 7: To reset the power supply, turn off the input power, then re-apply power after about one minute. 3 CSH Series 25W/50W/100W/150W CSJ Series 10W/15W Environmental Additional Functions Other Output Input Rating Item Conditions Rated Input Voltage Input Voltage Range Input Current (see Note 8) Rated input/output conditions Rated Frequency Frequency Range Efficiency (typ) (see Note 8) Rated input/output conditions Inrush Current (see Note 1, 8) Rated input/output conditions Rated Output Voltage Adjustable Output Voltage Range (see Note 5-a, b) Rated Output Current Adjustable Output Current Range Maximum Output Power Ripple Noise (mVp-p) (see Notes 2, 3, 8) Rated input/output conditions Constant Voltage Accuracy (see Notes 4, 5-a, b) Leakage Current (see Note 8) Rated input/output conditions Startup Time (see Note 8) Rated input/output conditions Output Holdup Time (see Note 8) Rated input/output conditions Over Current Protection Over Voltage Protection Remote Sensing Remote On/Off Control Display Operating Temperature Storage Temperature Operating Humidity Storage Humidity Cooling Requirements Vibration Resistance Vibration Frequency Test Duration Acceleration Vibration Direction Vibration Duration Shock Resistance Applicable Standards Structural Specifications Insulation Installation Conditions Insulation Withstand Voltage (see Note 6) Insulation Resistance (see Note 6) External Appearance Size (dimensions in mm) Weight PCB Material Safety Standards EMI Standards Between Input and Output Between Input and Frame Between Output and Frame Between Input and Output Between Input and Frame Between Output and Frame 50W CSH 050-05 CSH 050-12 CSH 050-15 CSH 050-24 100-120V AC 85 to 132V AC 1A (typ) 50/60 Hz 47 to 440 Hz 81% 86% 87% 90% 30 A (max) +5V +12V +15V +24V Rated voltage 10% 10A 4.2A 3.4A 2.1A 0 to 100% 50W 50.4W 51W 50.4W 80mVp-p 100mVp-p 100mVp-p 100mVp-p 3% 0.3mA (max) 400ms (typ) 16ms (min) Detection above 105% of rated current (output cutoff) Detection above 115% of rated voltage (output cutoff) Not provided Not provided Not provided -10 to +60C (70% load at -10C, 60C) -25 to +85C 30 to 90% (no condensation) 30 to 90% (no condensation) Natural air cooling 10 to 55 Hz 3 minutes 2G X, Y, and Z directions One hour in each direction 10 G With the unit resting on a smooth-surfaced wooden plank, at least 10 mm thick, each side of the unit is raised 50 mm and allowed to fall freely. This is performed three times for each of the four sides. Derating is necessary depending on the installation conditions. Refer to (2) below. 2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less) 500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less) 100 M (measured with 500 V DC Megger) Open frame 150 x 50 (or less) x 25 (W x D x H) about 150 g Designed to meet UL 1950 / Designed to meet CSA C22.2 No. 234 Level 3 / Designed to comply with the Electrical Appliance and Materials Control Law Designed to meet FCC Class B (100 to 120 V AC) / Designed to meet VCCI Class 2 Note 1: Note 2: More current may flow at restart. (Power thermistor type) Ripple noise is measured at a point 5 cm from the output connector, with a 63 V 47 F electrolytic capacitor attached at that point. Constant voltage accuracy is measured at the output connector. Note 3: Ripple noise is measured with a 100 MHz oscilloscope, using a 1:1 probe. Note 4: Constant voltage accuracy is the output voltage accuracy with a static input voltage over the range of 85 to 132 V AC, with a static load over the range of 0 to 100%, time drift of 10 minutes to 8 hours, over an ambient temperature range of -10 to 60C. Note 5: a) When varying the output voltage, the unit may be used in a range such that the output does not exceed the rated maximum output voltage or rated current. b) When adjusting downwards with a light load, the output voltage may rise and exceed the constant voltage accuracy specification. 4 CSH Series 25W/50W/100W/150W CSJ Series 10W/15W 100W CSH 100-05 82% +5V 20.0A 100W 120mVp-p CSH 100-12 150W CSH 100-15 100-120V AC 85 to 132V AC (see Note 9) 2.2A (typ) (see Note 8, 9) 50/60 Hz 47 to 440 Hz 87% 90% 30 A (max) +12V +15V Rated voltage 10% (see Note 4, 5-a, b) 8.5A 7.0A 0 to 100% 102W 105W 150mVp-p 150mVp-p 3% (see Note 4, 5-a, b) 0.3mA (max) (see Note 8) 300ms (typ) (see Note 8) 17ms (min) (see Note 8) CSH 100-24 CSH 150-05 90% 78% +24V +5V 4.3A 30.0A 103.2W 200mVp-p 150W 120mVp-p CSH 150-12 CSH 150-15 120V AC 85 to 132V AC (90 to 132V AC) (see Note 9) 3.5A (typ) (see Note 8) 50/60 Hz 47 to 440 Hz 84% 86% 30 A (max) +12V +15V Rated voltage 10% (see Note 4) 12.5A 10.0A 0 to 100% 150W 150W 150mVp-p 150mVp-p 3% (see Note 4, 5-a, b) 0.3mA (max) (see Note 8) 600ms (typ) (see Note 8) 17ms (min) (see Note 8) CSH 150-24 87% +24V 6.3A 151.2W 200mVp-p Detection above 105% of rated current (output cutoff) (see Note 10) Detection above 115% of rated voltage (output cutoff) (see Note 10) Not provided Not provided Not provided -10 to +60C -25 to +85C 30 to 90% (no condensation) Natural air cooling 10 to 55 Hz 3 minutes 2G X, Y, and Z directions One hour in each direction 10 G With the unit resting on a smooth-surfaced wooden plank, at least 10 mm thick, each side of the unit is raised 50 mm and allowed to fall freely. This is performed three times for each of the four sides. Derating is necessary depending on the installation conditions. Refer to (3) below. Derating is necessary depending on the installation conditions. Refer to (4) below. 2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less) (see Note 6) 500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less) (see Note 6) 100 M (measured with 500 V DC Megger) (see Note 6) Open frame (PCB only) 222 x 62 x 32 (W x D x H) about 520 g (380 g without high harmonic suppression reactor) (max) (see Note 9) CEM-1 Open frame (PCB only) 222 x 75 x 36 (W x D x H) about 520 g (without high harmonic suppression reactor) (max) CEM-1 Designed to meet UL 1950 / Designed to meet CSA C22.2 No. 234 Level 3 / Designed to comply with the Electrical Appliance and Materials Control Law Designed to meet FCC Class B (100 to 120 V AC) / Designed to meet VCCI Class 2 Note 6: Note 7: Note 8: Note 9: Note 10: Insulation specifications are for normal temperature and humidity. To reset the power supply, turn off the input power, then re-apply power after about one minute. Under standard input/output conditions at an ambient temperature of 25C. Values in parentheses are with the high harmonic reactor installed. If shutdown occurs due to over current or over voltage conditions, remove the source of the problem and re-apply power after about one minute powered off. * "Under rated input/output conditions" means that the switching power supply is operated under the rated input voltage, rated output current, rated frequency, and normal temperature and humidity. 5 CSH Series 25W/50W/100W/150W CSJ Series 10W/15W Environmental Additional Functions Other Output Input Rating Item Conditions Rated Input Voltage Input Voltage Range Input Current (see Note 8) Rated input/output conditions Rated Frequency Frequency Range Efficiency (typ) (see Note 8) Rated input/output conditions Inrush Current (see Note 1, 8) Rated input/output conditions Rated Output Voltage Adjustable Output Voltage Range (see Note 5-a) Rated Output Current Adjustable Output Current Range Maximum Output Power Ripple Noise (mVp-p) (see Notes 2, 3) Rated input/output conditions Constant Voltage Accuracy (see Notes 4, 5-a) Leakage Current (see Note 8) Rated input/output conditions Startup Time (see Note 8) Rated input/output conditions Output Holdup Time (see Note 8) Rated input/output conditions Over Current Protection Over Voltage Protection Remote Sensing Remote On/Off Control Display Operating Temperature Storage Temperature Operating Humidity Storage Humidity Cooling Requirements Vibration Resistance Vibration Frequency Test Duration Acceleration Vibration Direction Vibration Duration Shock Resistance Applicable Structural Standards Specifications Insulation Installation Conditions Insulation Withstand Voltage (see Note 6) Insulation Resistance (see Note 6) External Appearance Size (dimensions in mm) Weight PCB Material Safety Standards EMI Standards Between Input and Output Between Input and Frame Between Output and Frame Between Input and Output Between Input and Frame Between Output and Frame 10W CSJ 010-05 CSJ 010-12 CSJ 010-15 CSJ 010-24 100-120V AC 85 to 132V AC 0.3A (typ) 50/60 Hz 47 to 440 Hz 72% 73% 75% 77% 30 A (max, at cold start) +5V +12V +15V +24V Rated voltage 10% 2.0A 0.85A 0.7A 0.45A 0 to 100% 10.0W 10.2W 10.5W 10.8W 120mVp-p 150mVp-p 150mVp-p 200mVp-p 3% 0.3mA (max) 20ms (typ) 17ms (min) Detection above 105% of rated current (output cutoff) Detection above 115% of rated voltage (output cutoff) Not provided Not provided Not provided -10 to +60C (70% load at 60C) -25 to +85C 30 to 90% (no condensation) 30 to 90% (no condensation) Natural air cooling 10 to 55 Hz 3 minutes 2G X, Y, and Z directions One hour in each direction 10 G With the unit resting on a smooth-surfaced wooden plank, at least 10 mm thick, each side of the unit is raised 50 mm and allowed to fall freely. This is performed three times for each of the four sides. Derating is necessary depending on the installation conditions. Refer to (5) below. 2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less) 500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less) 100 M (measured with 500 V DC Megger) Open frame (PCB only) 94 x 49 x 17 (W x D x H) about 55 g CEM-1 Designed to meet UL 1950 / Designed to meet CSA C22.2 No. 234 Level 3 / Designed to comply with the Electrical Appliance and Materials Control Law Designed to meet FCC Class B (100 to 120 V AC) / Designed to meet VCCI Class 2 Note 1: Note 2: More current may flow at restart. (Power thermistor type) Ripple noise is measured at a point 5 cm from the output connector, with a 63 V 47 F electrolytic capacitor attached at that point. Constant voltage accuracy is measured at the output connector. Note 3: Ripple noise is measured with a 100 MHz oscilloscope, using a 1:1 probe. Note 4: Constant voltage accuracy is the output voltage accuracy with a static input voltage over the range of 85 to 132 V AC, with a static load over the range of 0 to 100%, time drift of 10 minutes to 8 hours, over an ambient temperature range of -10 to 60C. Note 5: a) When varying the output voltage, the unit may be used in a range such that the output does not exceed the rated maximum output voltage or rated current. b) When adjusting downwards with a light load, the output voltage may rise and exceed the constant voltage accuracy specification. 6 CSH Series 25W/50W/100W/150W CSJ Series 10W/15W 15W CSJ 015-05 CSJ 015-12 CSJ 015-15 CSJ 015-24 100-120V AC 85 to 132V AC 0.4A (typ) 50/60 Hz 47 to 440 Hz 72% 73% 75% 77% 30 A (max, at cold start) +5V +12V +15V +24V Rated voltage 10% 3.0A 1.25A 1.0A 0.65A 0 to 100% 15.0W 15.0W 15.0W 15.6W 120mVp-p 150mVp-p 150mVp-p 200mVp-p 3% 0.3mA (max) 20ms (typ) 16ms (min) Detection above 105% of rated current (output cutoff) Detection above 115% of rated voltage (output cutoff) Not provided Not provided Not provided -10 to +60C (70% load at 60C) -25 to +85C 30 to 90% (no condensation) 30 to 90% (no condensation) Natural air cooling 10 to 55 Hz 3 minutes 2G X, Y, and Z directions One hour in each direction 10 G With the unit resting on a smooth-surfaced wooden plank, at least 10 mm thick, each side of the unit is raised 50 mm and allowed to fall freely. This is performed three times for each of the four sides. Derating is necessary depending on the installation conditions. Refer to (6) below. 2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less) 500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less) 100 M (measured with 500 V DC Megger) Open frame (PCB only) 115 x 50 x 17 (W x D x H) about 70 g CEM-1 Designed to meet UL 1950 / Designed to meet CSA C22.2 No. 234 Level 3 / Designed to comply with the Electrical Appliance and Materials Control Law Designed to meet FCC Class B (100 to 120 V AC) / Designed to meet VCCI Class 2 Note 6: Note 7: Note 8: Note 9: Note 10: Insulation specifications are for normal temperature and humidity. To reset the power supply, turn off the input power, then re-apply power after about one minute. Under standard input/output conditions at an ambient temperature of 25C. Values in parentheses are with the high harmonic reactor installed. If shutdown occurs due to over current or over voltage conditions, remove the source of the problem and re-apply power after about one minute powered off. * "Under rated input/output conditions" means that the switching power supply is operated under the rated input voltage, rated output current, rated frequency, and normal temperature and humidity. 7 CSH Series 25W/50W/100W/150W CSJ Series 10W/15W Model CSH025-05 CSH025-12 CSH025-15 CSH025-24 Component mounting area 4- 3.5 Mounting holes 25 W (weight: approx. 85 g) 4 4 1 7 CN2 CN2 3.5 43 50 1 RV1 1 108 3.5 Compatible connectors and contacts 23 1 115 1 [lead cut] 3 mm max. Pin Compatible Compatible number Function Connector connectors contacts 1 AC (L) 2 NC SXH-001 3 NC B3 (7.5) BT-P0.6 CN1 4 AC (N) XH-A XHP-7 (JST) (JST) 5 NC (JST) or 6 NC BXH-001 7 FG T-P0.6 1-2 - B4B-XH-A XHP-4 (JST) CN2 3-4 + (JST) (JST) Vertical or horizontal mounting Adjustment knob CN2 CN2 Adjustment knob CN2 Adjustment knob * Compatible hand crimping tool for crimped connectors (made by JST): YC-110R, YRS-11 Vertical mounting 50 W (weight: approx. 150 g) Horizontal mounting 4- 3.5 CN2 1 FG5 40 50 1 Model CSH050-05 CSH050-12 CSH050-15 CSH050-24 N 4 5 L1 CN1 140 5 Compatible connectors and contacts [lead cut] 3 mm max. 25 1 150 1 Pin Compatible Compatible number Function Connector connectors contacts CN1 CN2 1 2 3 4 5 1-2 3-4 AC (L) NC AC (N) NC FG - + B5P3-VH (JST) VHR-5N (JST) Vertical or horizontal mounting Adjustment knob SVH-21TP1.1 (JST) CN2 CN2 Adjustment knob B4P-VH (JST) VHR-4N (JST) CN2 Adjustment knob Vertical mounting 8 Horizontal mounting Component mounting area Mounting holes CSH Series 25W/50W/100W/150W CSJ Series 10W/15W 100 W (weight: approx. 520 g) Model CSH100-05 CSH100-12 CSH100-15 CSH100-24 Vertical or horizontal mounting Compatible connectors and contacts Pin Compatible Compatible number Function Connector connectors contacts 1 AC (L) B3P5-VH VHR-5N CN1 3 AC (N) (JST) (JST) SVH-21T5 FG P1.1 (JST) 1-4 - B8P-VH VHR-8N CN2 5-8 + (JST) (JST) Adjustment knob CN2 CN2 Adjustment knob CN2 Adjustment knob Vertical mounting Horizontal mounting 150 W (weight: approx. 520 g) Model CSH150-05 CSH150-12 CSH150-15 CSH150-24 Vertical or horizontal mounting Compatible connectors and contacts Pin number Function Connector 1 AC (L) B3P5-VH CN1 3 AC (N) (JST) 5 FG CN2 1 - 6 + B6P-VH (JST) CN3 1 - 7 - B7P-VH (JST) CN2 Compatible Compatible connectors contacts VHR-5N (JST) SVH-21TP1.1 VHR-6N (JST) (JST) VHR-7N (JST) Fin CN3 CN2 CN3 Fin 10mm minimum 10mm minimum Vertical mounting 9 Horizontal mounting CSH Series 25W/50W/100W/150W CSJ Series 10W/15W 2- 3.5 Mounting holes 90.5 RV1 49 1 1 3.5 4 2 1 7 CN1 45.5 Model CSJ010-05 CSJ010-12 CSJ010-15 CSJ010-24 Component mounting area 10 W (weight: approx. 55 g) CN2 3.5 94 1 Vertical or horizontal mounting Adjustment knob CN2 CN2 Adjustment knob Vertical mounting Horizontal mounting 4- 3.5 15 W (weight: approx. 520 g) 43 Mounting holes 1 CN2 4 4 1 7 CN1 RV1 3.5 50 1 Model CSJ015-05 CSJ015-12 CSJ015-15 CSJ015-24 CN2 Adjustment knob Component mounting area * Compatible hand crimping tool for crimped connectors (made by JST): YC-110R, YRS-11 [lead cut] 3 mm max. Pin Compatible Compatible number Function Connector connectors contacts 1 AC (L) 2 NC SXH-001 3 NC B3 (7.5) BT-P0.6 CN1 4 AC (N) XH-A XHP-7 (JST) (JST) 5 NC (JST) or 6 NC BXH-001 7 FG T-P0.6 1 - B2B-XH-A XHP-2 (JST) CN2 2 + (JST) (JST) 17 1 Compatible connectors and contacts 108 3.5 Pin Compatible Compatible number Function Connector connectors contacts 1 AC (L) 2 NC SXH-001 3 NC B3 (7.5) BT-P0.6 CN1 4 AC (N) XH-A XHP-7 (JST) (JST) 5 NC (JST) or 6 NC BXH-001 7 FG T-P0.6 1-2 - B4B-XH-A XHP-4 (JST) CN2 3-4 + (JST) (JST) * Compatible hand crimping tool for crimped connectors (made by JST): YC-110R, YRS-11 [lead cut] 3 mm max. Compatible connectors and contacts 17 1 115 1 Vertical or horizontal mounting Adjustment knob CN2 CN2 Adjustment knob CN2 Adjustment knob Vertical mounting 10 Horizontal mounting CSH Series 25W/50W/100W/150W CSJ Series 10W/15W Output current derating for ambient temperature, installation conditions (1) CSH025 (4) CSH150 % 100 70 70 Output current Output current % 100 -10 0 50 60 C 60 -10 Ambient temperature (2) CSH050 25 50 Ambient temperature 60 C (5) CSJ010 % 100 70 70 Output current Output current % 100 -10 0 60 C 50 Ambient temperature -10 (3) CSH100 50 Ambient temperature 60 C 50 60 C (6) CSJ015 % 100 70 70 Output current Output current % 100 -10 50 60 C -10 Ambient temperature Ambient temperature 11