CSH Series 25W/50W/100W/150W
CSJ Series 10W/15W
3
Rating
Item Conditions
Rated Input Voltage
Input Voltage Range
Input Current Rated input/output conditions
Rated Frequency
Frequency Range
Efficiency (typ) Rated input/output conditions
Inrush Current (see Note 1) Rated input/output conditions
Rated Output Voltage
Adjustable Output Voltage Range (see Note 5-a, b)
Rated Output Current
Adjustable Output Current Range
Maximum Output Power
Ripple Noise (mVp-p) (see Notes 2, 3) Rated input/output conditions
Constant Voltage Accuracy (see Notes 4, 5-a, b)
Leakage Current Rated input/output conditions
Startup Time Rated input/output conditions
Output Holdup Time Rated input/output conditions
Over Current Protection (see Note 7)
Over Voltage Protection (see Note 7)
Remote Sensing
Remote On/Off Control
Display
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Cooling Requirements
Vibration Resistance Vibration Frequency
Test Duration
Acceleration
Vibration Direction
Vibration Duration
Shock Resistance
Installation Conditions
Insulation Withstand Voltage Between Input and Output
(see Note 6) Between Input and Frame
Between Output and Frame
Insulation Resistance Between Input and Output
(see Note 6) Between Input and Frame
Between Output and Frame
External Appearance
Size (dimensions in mm)
Weight
Safety Standards
EMI Standards
Input
Note 1: More current may flow at restart. (Power thermistor type)
Note 2: Ripple noise is measured at a point 5 cm from the output connector, with a 63 V 47 µF electrolytic capacitor attached at that point. Constant voltage accuracy is measured at
the output connector.
Note 3: Ripple noise is measured with a 100 MHz oscilloscope, using a 1:1 probe.
Note 4: Constant voltage accuracy is the output voltage accuracy with a static input voltage over the range of 85 to 132 V AC, with a static load over the range of 0 to 100%, time drift
of 10 minutes to 8 hours, over an ambient temperature range of -10 to 60°C.
Note 5: a) When varying the output voltage, the unit may be used in a range such that the output does not exceed the rated maximum output voltage or rated current.
b) When adjusting downwards with a light load, the output voltage may rise and exceed the constant voltage accuracy specification.
Note 6: Insulation specifications are for normal temperature and humidity.
Note 7: To reset the power supply, turn off the input power, then re-apply power after about one minute.
OutputOther
Additional
Functions
EnvironmentalInsulation
Structural
Specifications
Applicable
Standards
25W
CSH 025-05 CSH 025-12 CSH 025-15 CSH 025-24
100-120V AC
85 to 132V AC
0.6/0.5A (typ)
50/60 Hz
47 to 440 Hz
80% 83% 84% 86%
30 A (max)
+5V +12V +15V +24V
Rated voltage ±10%
5A 2.1A 1.7A 1.1A
0 to 100%
25W 25.2W 25.5W 26.4W
80mVp-p 100mVp-p 100mVp-p 100mVp-p
±3%
0.5mA (max)
400ms (typ)
16ms (min)
Detection above 105% of rated current (output cutoff)
Detection above 115% of rated voltage (output cutoff)
Not provided
Not provided
Not provided
-10 to +60°C (70% load at -10°C, 60°C)
-25 to +85°C
30 to 90% (no condensation)
30 to 90% (no condensation)
Natural air cooling
10 to 55 Hz
3 minutes
2 G
X, Y, and Z directions
One hour in each direction
10 G
With the unit resting on a smooth-surfaced wooden plank, at least 10 mm thick, each side of the unit is
raised 50 mm and allowed to fall freely. This is performed three times for each of the four sides.
Derating is necessary depending on the installation conditions. Refer to (1) below.
2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less)
500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less)
100 MΩ(measured with 500 V DC Megger)
Open frame
115 x 50 (or less) x 23 (W x D x H)
about 85 g
Designed to meet UL 1950 / Designed to meet CSA C22.2 No. 234 Level 3 /
Designed to comply with the Electrical Appliance and Materials Control Law
Designed to meet FCC Class B (100 to 120 V AC) / Designed to meet VCCI Class 2