Bridgelux Gen 7 V18 Array Series (R) Product Data Sheet DS102 1 V Series Introduction The V SeriesTM LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven at twice the nominal drive current, enabling design flexibility not previously possible. This high flux density light source is designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for commercial and residential applications. The V18 LED Array is available in a variety of electrical, CCT and CRI combinations providing substantial design flexibility and energy efficiencies. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and longer service life. Typical applications include, replacement lamps, and task, accent, spot, track, wide area, security, wall pack and down lights. Bridgelux Decor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Decor Series color points are available on Vero(R) SE Series, Vero(R) Series, V SeriesTM and H SeriesTM. Decor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Decor SeriesTM Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Decor Series Ultra is designed as a replacement for halogen lamps. Decor SeriesTM Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Decor Series Food products are a must have for any butcher counter or bakery. Decor SeriesTM Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Decor SeriesTM Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features Benefits * Efficacy of 160 lm/W typical * Enhanced optical control * Compact high flux density light source * Clean white light without pixilation * Uniform high quality illumination * High quality true color reproduction * Minimum 65, 70, 80, 90 and 95 CRI options * Significantly reduced thermal resistance and increased operating temperatures * Streamlined thermal path * ENERGY STAR(R) / ANSI compliant color binning structure with 2, 3 and 4 SDCM options * Uniform consistent white light * Lower operating costs * More energy efficient than incandescent, halogen and fluorescent lamps * Easy to use with daylight and motion detectors to enable increased energy savings * Low voltage DC operation * Reduced maintenance costs * Instant light with unlimited dimming * Environmentally friendly, no disposal issue * Vf bin code backside marking Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 7 Electrical Characteristics 13 Eye Safety 14 Absolute Maximum Ratings 15 Performance Curves 16 Typical Radiation Pattern 19 Typical Color Spectrum 20 Mechanical Dimensions 21 Color Binning Information 22 Packaging and Labeling 23 Design Resources 25 Precautions 25 Disclaimers 25 About Bridgelux 26 1 Product Feature Map Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux's LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. Polarity symbols Designed to comply with global safety standards for creepage and clearance distances Fully engineered substrate for consistent thermal, mechanical and optical properties White ring around LES Yellow phosphor Light Emitting Surface (LES) Case Temperature (Tc) Measurement Point Solder Pads Note: Part number and lot codes are scribed on back of array Product Nomenclature The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 56 7 8 9 10 11 - 12 - 13 14 BXRE - 30 E 400 0 - C - 7 3 CCT Bin Options Product Family Nominal CCT 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI B = 63 CRI typ. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 400x = 4000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25C (lm) Minimum Pulsed Flux6,7 Tc = 25C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-17E4000-B-74 1750 80 900 2774 2497 34.8 31.3 89 BXRE-20B4001-C-73 2000 65 1170 6081 5473 34.8 40.7 149 BXRE-25E4000-B-74 2500 80 900 4484 4036 34.8 31.3 143 BXRE-27E4000-B-7X 2700 80 900 4807 4326 34.8 31.3 153 BXRE-27E4000-C-7X 2700 80 1170 6249 5624 34.8 40.7 153 BXRE-27G40H0-B-7X 2700 90 900 4166 3749 34.8 31.3 133 BXRE-27G40H0-C-7X 2700 90 1170 5415 4874 34.8 40.7 133 BXRE-27G4000-B-7X 2700 90 900 4000 3600 34.8 31.3 128 BXRE-27G4000-C-7X 2700 90 900 5200 4680 34.8 40.7 128 BXRE-27H4000-B-7X 2700 97 1170 3484 3136 34.8 31.3 111 BXRE-30C4001-B-74 3000 70 900 5512 4961 34.8 31.3 176 BXRE-30C4001-C-74 3000 70 1170 7166 6449 34.8 40.7 176 BXRE-30E4000-B-7X 3000 80 1170 5000 4500 34.8 31.3 160 BXRE-30E4000-C-7X 3000 80 900 6500 5850 34.8 40.7 160 BXRE-30G40H0-B-7X 3000 90 900 4353 3918 34.8 31.3 139 BXRE-30G40H0-C-7X 3000 90 1170 5660 5094 34.8 40.7 139 BXRE-30G4000-B-7X 3000 90 900 4161 3745 34.8 31.3 133 BXRE-30G4000-C-7X 3000 90 1170 5410 4869 34.8 40.7 133 BXRE-30G400C-B-73 3000 90 900 3881 3493 34.8 31.4 124 BXRE-30H4000-B-7X 3000 97 900 3710 3339 34.8 31.3 118 BXRE-35E4000-B-7X 3500 80 1170 5162 4645 34.8 31.3 165 BXRE-35E4000-C-7X 3500 80 900 6710 6039 34.8 40.7 165 BXRE-35G4000-B-7X 3500 90 1170 4291 3861 34.8 31.3 137 BXRE-35G4000-C-7X 3500 90 900 5578 5020 34.8 40.7 137 BXRE-35A4001-B-738,9 3500 93 1170 4040 3636 34.8 31.3 129 BXRE-40C4001-B-74 4000 70 900 5645 5081 34.8 31.3 180 BXRE-40C4001-C-74 4000 70 1170 7339 6605 34.8 40.7 180 BXRE-40E4000-B-7X 4000 80 900 5194 4674 34.8 31.3 166 BXRE-40E4000-C-7X 4000 80 1170 6752 6077 34.8 40.7 166 BXRE-40G4000-B-7X 4000 90 900 4452 4007 34.8 31.3 142 BXRE-40G4000-C-7X 4000 90 1170 5787 5209 34.8 40.7 142 BXRE-50C4001-B-74 5000 70 900 5710 5139 34.8 31.3 182 BXRE-50C4001-C-74 5000 70 1170 7423 6681 34.8 40.7 182 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a 7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center's Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70C. GAI may vary depending on fixture design and performance. 3 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25C (lm) Minimum Pulsed Flux6,7 Tc = 25C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 171 BXRE-50E4001-B-74 5000 80 900 5355 4820 34.8 31.3 BXRE-50E4001-C-74 5000 80 1170 6962 6265 34.8 40.7 171 BXRE-50G4001-B-74 5000 90 900 4549 4094 34.8 31.3 145 BXRE-50G4001-C-74 5000 90 1170 5913 5322 34.8 40.7 145 BXRE-57C4001-B-74 5700 70 900 5516 4965 34.8 31.3 176 BXRE-57C4001-C-74 5700 70 1170 7171 6454 34.8 40.7 176 BXRE-57E4001-B-74 5700 80 900 5293 4764 34.8 31.3 169 BXRE-57E4001-C-74 5700 80 1170 6881 6193 34.8 40.7 169 BXRE-65C4001-B-74 6500 70 900 5613 5052 34.8 31.3 179 BXRE-65C4001-C-74 6500 70 1170 7297 6567 34.8 40.7 179 BXRE-65E4001-B-74 6500 80 900 5387 4848 34.8 31.3 172 BXRE-65E4001-C-74 6500 80 1170 7003 6303 34.8 40.7 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a 7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center's Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70C. GAI may vary depending on fixture design and performance. Table 2: Selection Guide, Stabilized DC Performance (Tc = 70C) 7,8 Part Number Nominal CCT1 (K) GAI BXRE-35A4001-B-73 3500 80 2 CRI Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70C (lm) Minimum DC Flux6,9 Tc = 70C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 93 900 3757 3382 34.3 30.9 121 3 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center's Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70C. GAI may vary depending on fixture design and performance. 3. All CRI values are measured at Tj = Tc = 25C. CRI Values are specified as typical. 4. 5. 6. 7. 8. Drive current is referred to as nominal drive current. Typical performance values are provided as a reference only and are not a guarantee of performance. Bridgelux maintains a 7% tolerance on flux measurements. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 4 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85C (lm) Minimum DC Flux6 Tc = 85C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-17E4000-B-74 1750 80 900 2497 2497 2247 30.6 82 BXRE-20B4001-C-73 2000 65 1170 5473 5473 4926 39.8 138 BXRE-25E4000-B-74 2500 80 900 4036 4036 3632 30.6 132 BXRE-27E4000-B-7X 2700 80 900 4326 4326 3893 30.6 142 BXRE-27E4000-C-7X 2700 80 1170 5624 5624 5061 39.7 142 BXRE-27G40H0-B-7X 2700 90 900 3600 3749 3374 30.6 123 BXRE-27G40H0-C-7X 2700 90 1170 4680 4874 4386 39.7 123 BXRE-27G4000-B-7X 2700 90 900 3136 3600 3240 30.6 118 BXRE-27G4000-C-7X 2700 90 1170 4500 4680 4212 39.7 118 BXRE-27H4000-B-7X 2700 97 900 5850 3136 2822 30.6 103 BXRE-30C4001-B-74 3000 70 900 3745 4961 4465 30.6 162 BXRE-30C4001-C-74 3000 70 1170 4869 6449 5804 39.7 162 147 BXRE-30E4000-B-7X 3000 80 900 3493 4500 4050 30.6 BXRE-30E4000-C-7X 3000 80 1170 3339 5850 5265 39.7 147 BXRE-30G40H0-B-7X 3000 90 900 4645 3918 3526 30.6 128 BXRE-30G40H0-C-7X 3000 90 1170 6039 5094 4584 39.7 128 BXRE-30G4000-B-7X 3000 90 900 3861 3745 3371 30.6 123 BXRE-30G4000-C-7X 3000 90 1170 5020 4869 4382 39.7 123 BXRE-30G400C-B-73 3000 90 900 3636 3493 3144 30.6 114 BXRE-30H4000-B-7X 3000 97 900 4674 3339 3005 30.6 109 BXRE-35E4000-B-7X 3500 80 900 6077 4645 4181 30.6 152 BXRE-35E4000-C-7X 3500 80 1170 4007 6039 5435 39.7 152 BXRE-35G4000-B-7X 3500 90 900 5209 3861 3475 30.6 126 126 BXRE-35G4000-C-7X 3500 90 1170 5139 5020 4518 39.7 BXRE-35A4001-B-738,9 3500 93 900 6681 3636 3273 30.6 119 BXRE-40C4001-B-74 4000 70 900 4820 5081 4573 30.6 166 BXRE-40C4001-C-74 4000 70 1170 6265 6605 5945 39.7 166 BXRE-40E4000-B-7X 4000 80 900 4094 4674 4207 30.6 153 BXRE-40E4000-C-7X 4000 80 1170 5322 6077 5469 39.7 153 BXRE-40G4000-B-7X 4000 90 900 4965 4007 3606 30.6 131 BXRE-40G4000-C-7X 4000 90 1170 6454 5209 4688 39.7 131 BXRE-50C4001-B-74 5000 70 900 4764 5139 4625 30.6 168 BXRE-50C4001-C-74 5000 70 1170 6193 6681 6013 39.7 168 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85C. 2. All CRI values are measured at Tj = Tc = 25C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center's Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70C. GAI may vary depending on fixture design and performance. 5 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85C (lm) Minimum DC Flux6 Tc = 85C (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-50E4001-B-74 5000 80 900 4820 4338 33.9 30.6 158 BXRE-50E4001-C-74 5000 80 1170 6265 5639 33.9 39.7 158 BXRE-50G4001-B-74 5000 90 900 4094 3684 33.9 30.6 134 BXRE-50G4001-C-74 5000 90 1170 5322 4790 33.9 39.7 134 BXRE-57C4001-B-74 5700 70 900 4965 4468 33.9 30.6 162 BXRE-57C4001-C-74 5700 70 1170 6454 5809 33.9 39.7 162 BXRE-57E4001-B-74 5700 80 900 4764 4287 33.9 30.6 156 BXRE-57E4001-C-74 5700 80 1170 6193 5574 33.9 39.7 156 BXRE-65C4001-B-74 6500 70 900 5052 4547 33.9 30.6 165 BXRE-65C4001-C-74 6500 70 1170 6567 5911 33.9 39.7 165 BXRE-65E4001-B-74 6500 80 900 4848 4364 33.9 30.6 159 BXRE-65E4001-C-74 6500 80 1170 6303 5673 33.9 39.7 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85C. 2. All CRI values are measured at Tj = Tc = 25C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. 4. Bridgelux maintains a 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center's Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70C. GAI may vary depending on fixture design and performance. 6 Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the flux vs. current characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRE-17E4000-B-74 80 BXRE-20B4001-C-73 65 BXRE-25E4000-B-74 80 BXRE-27E4000-B-7X 80 BXRE-27E4000-C-7X 80 BXRE-27G40H0-B-7X 90 BXRE-27G40H0-C-7X 90 BXRE-27G4000-B-7X 90 Drive Current1 (mA) Typical Vf Tc = 25C (V) Typical Power Tc = 25C (W) Typical Flux2 Tc = 25C (lm) Typical DC Flux3 Tc = 85C (lm) Typical Efficacy Tc = 25C (lm/W) 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 1467 1923 2774 4014 5119 3132 4102 6081 8536 10864 2371 3108 4484 6488 8274 2542 3332 4807 6955 8869 3218 4215 6249 8772 11164 2203 2887 4166 6027 7686 2789 3653 5415 7602 9675 2116 2773 4000 5788 7381 1344 1758 2497 3641 4621 2759 3595 5473 7286 9112 2172 2842 4036 5885 7469 2329 3046 4326 6309 8006 2835 3694 5624 7487 9363 2018 2640 3749 5467 6939 2457 3201 4874 6488 8114 1938 2535 3600 5250 6663 98 95 88 82 76 161 156 149 134 124 159 153 143 133 123 170 164 153 142 131 166 160 153 138 127 147 142 133 123 114 144 139 133 120 110 142 137 128 118 109 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 7 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-27G4000-C-7X 90 BXRE-27H4000-B-7X 97 BXRE-30C4001-B-74 70 BXRE-30C4001-C-74 70 BXRE-30E4000-B-7X 80 BXRE-30E4000-C-7X 80 BXRE-30G40H0-B-7X 90 BXRE-30G40H0-C-7X 90 BXRE-30G4000-B-7X 90 Drive Current1 (mA) Typical Vf Tc = 25C (V) Typical Power Tc = 25C (W) Typical Flux2 Tc = 25C (lm) Typical DC Flux3 Tc = 85C (lm) Typical Efficacy Tc = 25C (lm/W) 585 780 1170 1755 2340 450 600 900 1350 1800 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 2678 3508 5200 7300 9291 1843 2415 3484 5041 6428 2839 3719 5512 7738 9848 3790 4967 7166 10368 13222 2644 3466 5000 7235 9226 3348 4385 6500 9125 11613 2302 3017 4353 6299 8033 2915 3818 5660 7945 10111 2201 2884 4161 6021 7678 2360 3074 4680 6230 7792 1688 2208 3136 4573 5803 2501 3258 4961 6604 8260 3472 4541 6449 9405 11936 2422 3169 4500 6563 8329 2949 3842 5850 7788 9740 2109 2759 3918 5714 7252 2568 3345 5094 6781 8480 2016 2637 3745 5462 6932 138 133 128 115 106 123 119 111 103 95 190 184 176 158 146 195 189 176 163 151 177 171 159 148 137 172 166 159 143 133 154 149 139 129 119 150 145 139 125 115 147 142 133 123 114 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-30G4000-C-7X 90 BXRE-30G400C-B-73 90 BXRE-30H4000-B-7X 97 BXRE-35E4000-B-7X 80 BXRE-35E4000-C-7X 80 BXRE-35G4000-B-7X 90 BXRE-35G4000-C-7X 90 BXRE-35A4001-B-73 93 BXRE-40C4001-B-74 70 Drive Current1 (mA) Typical Vf Tc = 25C (V) Typical Power Tc = 25C (W) Typical Flux2 Tc = 25C (lm) Typical DC Flux3 Tc = 85C (lm) Typical Efficacy Tc = 25C (lm/W) 585 780 1170 1755 2340 450 600 900 1350 1800 450 600 900 1350 1800 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 450 600 900 1350 1800 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.3 37.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 14.9 20.3 31.4 49.0 67.5 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 14.9 20.3 31.4 49.0 67.5 2786 3650 5410 7594 9665 2052 2690 3881 5615 7161 1962 2571 3710 5368 6845 2730 3577 5162 7468 9524 3456 4527 6710 9419 11988 2269 2974 4291 6208 7916 2873 3763 5578 7830 9965 2137 2800 4040 5846 7455 2908 3808 5645 7925 10086 2455 3198 4869 6482 8106 1880 2459 3493 5094 6465 1797 2351 3339 4869 6180 2501 3271 4645 6774 8598 3045 3966 6039 8039 10054 2079 2719 3861 5631 7147 2531 3297 5020 6683 8358 1957 2560 3636 5303 6730 2562 3337 5081 6764 8459 143 139 133 119 110 137 133 124 115 106 131 127 118 110 101 183 177 165 153 141 178 172 165 148 137 152 147 137 127 117 148 143 137 123 114 143 138 129 119 110 195 188 180 162 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 9 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-40C4001-C-74 70 BXRE-40E4000-B-7X 80 BXRE-40E4000-C-7X 80 BXRE-40G4000-B-7X 90 BXRE-40G4000-C-7X 90 BXRE-50C4001-B-74 70 BXRE-50C4001-C-74 70 BXRE-50E4001-B-74 80 BXRE-50E4001-C-74 80 Drive Current1 (mA) Typical Vf Tc = 25C (V) Typical Power Tc = 25C (W) Typical Flux2 Tc = 25C (lm) Typical DC Flux3 Tc = 85C (lm) Typical Efficacy Tc = 25C (lm/W) 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 3881 5087 7339 10619 13541 2747 3600 5194 7515 9583 3478 4555 6752 9478 12063 2354 3086 4452 6441 8214 2981 3904 5787 8124 10340 3020 3958 5710 8261 10535 3823 5007 7423 10420 13262 2832 3712 5355 7748 9881 3586 4696 6962 9773 12437 3555 4651 6605 9632 12225 2516 3291 4674 6817 8651 3064 3991 6077 8089 10117 2157 2821 4007 5843 7415 2626 3421 5209 6934 8672 2766 3618 5139 7494 9511 3368 4388 6681 8893 11123 2594 3394 4820 7028 8920 3159 4115 6265 8341 10431 200 193 180 167 155 184 178 166 153 142 179 173 166 149 138 158 152 142 132 122 153 148 142 128 118 202 195 182 169 156 197 190 182 164 151 190 183 171 158 146 185 178 171 154 142 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-50G4001-B-74 90 BXRE-50G4001-C-74 90 BXRE-57C4001-B-74 70 BXRE-57C4001-C-74 70 BXRE-57E4001-B-74 80 BXRE-57E4001-C-74 80 BXRE-65C4001-B-74 70 BXRE-65C4001-C-74 70 BXRE-65E4001-B-74 80 Drive Current1 (mA) Typical Vf Tc = 25C (V) Typical Power Tc = 25C (W) Typical Flux2 Tc = 25C (lm) Typical DC Flux3 Tc = 85C (lm) Typical Efficacy Tc = 25C (lm/W) 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 585 780 1170 1755 2340 450 600 900 1350 1800 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 33.2 33.8 34.8 36.2 37.5 33.2 33.8 34.8 36.3 37.5 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 19.4 26.3 40.8 63.6 87.6 14.9 20.3 31.4 49.0 67.5 2406 3153 4549 6581 8393 3046 3989 5913 8301 10564 2917 3823 5516 7981 10178 3694 4838 7171 10067 12812 2799 3669 5293 7658 9766 3544 4642 6881 9660 12293 2969 3890 5613 8121 10357 3759 4923 7297 10244 13037 2849 3734 5387 7794 9940 2204 2882 4094 5970 7577 2683 3495 5322 7085 8860 2672 3496 4965 7240 9189 3254 4239 6454 8592 10746 2564 3354 4764 6947 8817 3122 4067 6193 8244 10311 2719 3557 5052 7367 9350 3311 4313 6567 8743 10934 2610 3414 4848 7070 8973 161 156 145 134 124 157 151 145 131 121 195 189 176 163 151 190 184 176 158 146 187 181 169 156 145 182 176 169 152 140 199 192 179 166 153 194 187 179 161 149 191 184 172 159 147 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number BXRE-65E4001-C-74 CRI Drive Current1 (mA) Typical Vf Tc = 25C (V) Typical Power Tc = 25C (W) Typical Flux2 Tc = 25C (lm) Typical DC Flux3 Tc = 85C (lm) Typical Efficacy Tc = 25C (lm/W) 80 585 780 1170 1755 2340 33.2 33.8 34.8 36.2 37.5 19.4 26.3 40.8 63.6 87.6 3607 4724 7003 9831 12512 3178 4140 6303 8390 10494 186 179 172 155 143 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25C (V) 1, 2, 3, 8 Part Number BXRE-xxx400x-B-7x BXRE-xxx400x-C-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 Vf/Tc (mV/C) Typical Thermal Resistance Junction to Case5,6 Rj-c (C/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105C (V) Vf Max. Cold Tc = -40C (V) 0.15 31.1 38.4 -14.5 0.18 33.5 41.2 37.5 -14.5 0.11 31.1 38.4 40.3 -14.5 0.13 33.5 41.2 Minimum Typical Maximum 900 32.2 34.8 37.5 -14.5 1800 34.7 37.5 40.3 1170 32.2 34.8 2340 34.6 37.5 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 13 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRE-xxx400x-B-7x BXRE-xxx400x-C-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 900 RG1 RG1 RG1 RG1 1350 RG1 RG1 RG1 RG2 1800 RG1 RG1 RG2 RG2 1170 RG1 RG1 RG1 RG1 1755 RG1 RG1 RG2 RG2 2340 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 14 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 125C Storage Temperature -40C to +105C Operating Case Temperature1 (Tc) 105C Soldering Temperature2 300C or lower for a maximum of 6 seconds BXRE-xxx400x-B-7x BXRE-xxx400x-C-7x Maximum Drive Current3 1800mA 2340mA Maximum Peak Pulsed Drive Current4 2570mA 3340mA Maximum Reverse Voltage5 -60V -60V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 15 Performance Curves Figure 2: V18C Drive Current vs. Voltage 2000 2500 1800 2250 1600 2000 1400 1750 Forward Current (mA) Forward Current (mA) Figure 1: V18B Drive Current vs. Voltage 1200 1000 800 600 1500 1250 1000 750 400 500 200 250 0 32 33 34 35 36 37 0 38 32 33 34 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux 200% 120% 100% 80% 60% 80% 60% 40% 20% 0% 600 800 1000 1200 Forward Current (mA) 38 100% 20% 400 37 120% 40% 200 36 Figure 4: V18C Typical Relative Flux vs. Current Figure 3: V18B Typical Relative Flux vs. Current 0 35 Forward Voltage (V) Forward Voltage (V) 1400 1600 1800 2000 0% 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 Forward Current (mA) Notes for Figures 1-4: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25C. 16 Performance Curves Figure 5: Typical DC Flux vs. Case Temperature Figure 6: Typical DC ccy Shift vs. Case Temperature 0 103% Neutral White 50 75 100 125 0.000 Cool White 25C Pulsed 97% -0.003 ccy Shift Relative Luminous Flux 100% 25 0.003 Warm White 94% 91% -0.006 -0.009 88% Warm White Neutral White -0.012 85% Cool White 25C Pulsed -0.015 82% 0 25 50 75 100 125 Case Temperature (C) Case Temperature (C) Figure 8: 1750K Color Shift vs. Case Temperature1 Figure 7: Typical DC ccx Shift vs. Case Temperature 0.3705 0 25 50 75 100 125 0.37 0.000 Pulsed Center Point Tc = 25C 15C 25C -0.002 0.3695 45C ccy ccx Shift -0.004 -0.006 0.369 70C -0.008 85C Warm White -0.010 -0.012 Neutral White 0.3685 Cool White 105C 25C Pulsed Case Temperature (C) 0.368 0.5196 0.5198 0.52 0.5202 0.5204 0.5206 ccx Notes for Figures 5-7: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 17 Performance Curves Figure 9: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 10: 2500K Color Shift vs. Case Temperature1 0.4145 0.4101 0.41 15C 0.413 45C 0.4096 0.4095 65C 0.4093 45C 0.4125 70C 0.412 0.4094 85C 0.4115 85C 0.4092 0.526 0.527 0.528 0.529 0.53 0.531 105C 0.411 105C 0.4091 0.409 0.525 0.4105 0.468 0.532 0.47 0.472 0.474 ccx 0.476 0.478 ccx Figure 11: 2700K, 97 CRI Color Shift vs. Case Temperature1 Figure 12: 3000K, 90 CRI Color Shift vs. Case Temperature3 0.4110 0.403 15C Pulsed Center Point Tc = 25C 0.4100 25C 15C 0.402 Pulsed Center Point Tc=25C 25C 0.401 0.4090 0.4080 45C 0.4 45C ccy ccy Pulsed Center Point Tc = 25C 0.4135 25C 0.4097 ccy 25C ccy 0.4099 0.4098 15C 0.414 Pulsed Center Point Tc=25C 0.4070 0.399 65C 65C 0.398 0.4060 85C 0.397 85C 0.4050 105C 0.396 0.4040 105C 0.4030 0.457 0.4572 0.4574 0.4576 0.4578 0.395 0.444 0.458 0.4445 0.445 0.4455 0.446 0.4465 0.447 ccx ccx Figure 13: 3000K, 97 CRI Color Shift vs. Case Temperature1 Figure 14: 3500K Class A Color Shift vs. Case Temperature1 0.4050 0.37 15C Pulsed Center Point Tc = 25C 15C 0.4030 25C 0.368 25C 0.366 0.4010 45C ccy ccy 45C 70C 0.3990 0.364 70C 0.362 85C 0.3970 Pulsed Center Point Tc=25C 105C 85C 0.36 105C 0.3950 0.4323 0.4328 0.4333 0.4338 0.4343 0.4348 0.4353 ccx 0.358 0.392 0.393 0.394 0.395 0.396 0.397 ccx Note for Figures 8-14: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of 0.002. 3. Characteristics shown for Decor Series Showcase products, BXRE-30G400C-x-73 18 Typical Radiation Pattern Figure 15: Typical Spatial Radiation Pattern Note for Figure 15: 1. Typical viewing angle is 120. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is 1/2 of the peak value. Figure 16: Typical Polar Radiation Pattern 19 Typical Color Spectrum Figure 17: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 17: 1. Color spectra measured at nominal current for Tj = Tc = 25C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 18: Typical Color Spectrum for Decor Series 1 17E 20B 0.9 25E 27H 0.8 30G (Decor Series Showcase) Relative Spectral Power Distribution 30H 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 18: 1. Color spectra measured at nominal current for Tj = Tc = 25C. 20 Mechanical Dimensions Figure 19: Drawing for V18 LED Array Notes for Figure 19; 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are 0.1mm. 4. Solder pad labeled "+" denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 21 Color Binning Information Figure 20: Warm and Neutral White Test Bins in xy Color Space 0.44 2500K 4SDCM 3 SDCM 4 SDCM 2000K 3SDCM 2700K 0.42 3000K 3500K 0.4 Y 4000K 1750K 4SDCM 0.38 0.36 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 Note: Pulsed Test Conditions, Tc = 25C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 1750K 2000K 2500K ANSI Bin (for reference only) - - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5167, 0.336) (0.5280, 0.4100) (0.4765, 0.4137) 2700K 3000K1 (0.4578, 0.4101) 3500K1 4000K1 (0.4338, 0.403) (0.4073, 0.3917) (0.3818, 0.3797) (0.4465, 0.4024)2 Note for Table 8: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Figure 21: Graph of Cool White Test Bins in xy Color Space 0.39 4 SDCM 3 SDCM 0.38 0.37 5000K 0.36 5700K Y 0.35 0.34 6500K 0.33 0.32 0.31 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25C Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 22 Packaging and Labeling Figure 22: Drawing for V18 Packaging Tube Notes for Figure 22: 1. Each tube holds 20 V18 COB arrays. 2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. 4. Dimensions for each tube are 26.3 (W) x 9.5(H) x 510 (L). Dimensions for the anti-static bag are 75 (W) x 615 (L) x 3.1 (T) mm. Dimensions for the shipping box are 58.7 x 13.3 x 7.9 cm 23 Packaging and Labeling Figure 23: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E4000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 24 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN101 for additional information. CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 25 About Bridgelux: Bridging Light and LifeTM At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we've designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light's impact on human behavior, delivering products that create better environments, experiences and returns--both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com (c) 2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 V18 Array Series Product Data Sheet DS102 Rev. M (09/2018) 26