1
Bridgelux® Gen 7 V18 Array Series
Product Data Sheet DS102
Introduction
The V Series™ LED Array products deliver high quality light in a compact and cost-eective solid-state lighting package.
These chip on board (CoB) arrays can be eciently driven at twice the nominal drive current, enabling design exibility not
previously possible. This high ux density light source is designed to support a wide range of high quality, low cost directional
luminaires and replacement lamps for commercial and residential applications.
The V18 LED Array is available in a variety of electrical, CCT and CRI combinations providing substantial design exibility and
energy eciencies.
Lighting system designs incorporating these LED arrays deliver increased system level ecacy and longer service life. Typical
applications include, replacement lamps, and task, accent, spot, track, wide area, security, wall pack and down lights.
Bridgelux Décor Series is our state of the art color line designed specically for premium applications, producing unmatched
LED light quality with brilliant color-rendering options and oer pleasing and inspiring lighting palettes. Bridgelux Décor
Series color points are available on Vero® SE Series, Vero® Series, V Series™ and H Series™.
Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is designed as a replacement for halogen lamps.
Décor Series™ Food products oer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white
light with enhanced spectrum coverage and higher ecacy.
V Series
Features
Ecacy of 160 lm/W typical
Compact high ux density light source
Uniform high quality illumination
Minimum 65, 70, 80, 90 and 95 CRI options
Streamlined thermal path
ENERGY STAR® / ANSI compliant color binning
structure with 2, 3 and 4 SDCM options
More energy ecient than incandescent, halogen
and uorescent lamps
Low voltage DC operation
Instant light with unlimited dimming
• Vf bin code backside marking
Benets
Enhanced optical control
Clean white light without pixilation
High quality true color reproduction
Signicantly reduced thermal resistance and
increased operating temperatures
Uniform consistent white light
Lower operating costs
Easy to use with daylight and motion detectors to
enable increased energy savings
Reduced maintenance costs
Environmentally friendly, no disposal issue
1
Contents
Product Feature Map 2
Product Nomenclature 2
Product Selection Guide 3
Performance at Commonly Used Drive Currents 7
Electrical Characteristics 13
Eye Safety 14
Absolute Maximum Ratings 15
Performance Curves 16
Typical Radiation Pattern 19
Typical Color Spectrum 20
Mechanical Dimensions 21
Color Binning Information 22
Packaging and Labeling 23
Design Resources 25
Precautions 25
Disclaimers 25
About Bridgelux 26
2
Product Feature Map
Product Nomenclature
The part number designation for Bridgelux V Series LED arrays is explained as follows:
1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14
Product Family CCT Bin Options
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
CRI
B = 63 CRI typ.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
Array Conguration
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
BXRE 30 E 400 0 C – 7 3
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Décor Series Showcase Target
Gen. 7
Nominal CCT
Flux Indicator
400x = 4000 lm
Bridgelux arrays are fully engineered devices that
provide consistent thermal and optical performance on an
engineered mechanical platform. The V Series arrays are
the most compact chip-on-board devices across all of
Bridgelux’s LED Array products. The arrays incorporate
several features to simplify design integration and
assembly. Please visit www.bridgelux.com for more
information on the V Series family of products.
Fully engineered substrate
for consistent thermal, mechanical
and optical properties
Yellow phosphor Light
Emitting Surface (LES)
Note: Part number and lot codes are scribed on back of array
Polarity symbols
Solder Pads
White ring around LES
Case Temperature (Tc) Measurement Point
Designed to comply with global
safety standards for creepage
and clearance distances
3
Product Selection Guide
The following product congurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Ecacy
(lm/W)
BXRE-17E4000-B-74 1750 80 900 2774 2497 34.8 31.3 89
BXRE-20B4001-C-73 2000 65 1170 6081 5473 34.8 40.7 149
BXRE-25E4000-B-74 2500 80 900 4484 4036 34.8 31.3 143
BXRE-27E4000-B-7X 2700 80 900 4807 4326 34.8 31.3 153
BXRE-27E4000-C-7X 2700 80 1170 6249 5624 34.8 40.7 153
BXRE-27G40H0-B-7X 2700 90 900 4166 3749 34.8 31.3 133
BXRE-27G40H0-C-7X 2700 90 1170 5415 4874 34.8 40.7 133
BXRE-27G4000-B-7X 2700 90 900 4000 3600 34.8 31.3 128
BXRE-27G4000-C-7X 2700 90 900 5200 4680 34.8 40.7 128
BXRE-27H4000-B-7X 2700 97 1170 3484 3136 34.8 31.3 111
BXRE-30C4001-B-74 3000 70 900 5512 4961 34.8 31.3 176
BXRE-30C4001-C-74 3000 70 1170 7166 6449 34.8 40.7 176
BXRE-30E4000-B-7X 3000 80 1170 5000 4500 34.8 31.3 160
BXRE-30E4000-C-7X 3000 80 900 6500 5850 34.8 40.7 160
BXRE-30G40H0-B-7X 3000 90 900 4353 3918 34.8 31.3 139
BXRE-30G40H0-C-7X 3000 90 1170 5660 5094 34.8 40.7 139
BXRE-30G4000-B-7X 3000 90 900 4161 3745 34.8 31.3 133
BXRE-30G4000-C-7X 3000 90 1170 5410 4869 34.8 40.7 133
BXRE-30G400C-B-73 3000 90 900 3881 3493 34.8 31.4 124
BXRE-30H4000-B-7X 3000 97 900 3710 3339 34.8 31.3 118
BXRE-35E4000-B-7X 3500 80 1170 5162 4645 34.8 31.3 165
BXRE-35E4000-C-7X 3500 80 900 6710 6039 34.8 40.7 165
BXRE-35G4000-B-7X 3500 90 1170 4291 3861 34.8 31.3 137
BXRE-35G4000-C-7X 3500 90 900 5578 5020 34.8 40.7 137
BXRE-35A4001-B-738,9 3500 93 1170 4040 3636 34.8 31.3 129
BXRE-40C4001-B-74 4000 70 900 5645 5081 34.8 31.3 180
BXRE-40C4001-C-74 4000 70 1170 7339 6605 34.8 40.7 180
BXRE-40E4000-B-7X 4000 80 900 5194 4674 34.8 31.3 166
BXRE-40E4000-C-7X 4000 80 1170 6752 6077 34.8 40.7 166
BXRE-40G4000-B-7X 4000 90 900 4452 4007 34.8 31.3 142
BXRE-40G4000-C-7X 4000 90 1170 5787 5209 34.8 40.7 142
BXRE-50C4001-B-74 5000 70 900 5710 5139 34.8 31.3 182
BXRE-50C4001-C-74 5000 70 1170 7423 6681 34.8 40.7 182
Notes for Table 1:
1. Nominal CCT as dened by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on ux measurements.
7. Minimum ux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is dened by the Lighting Research Center’s Class A denition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal xture level performance, GAI is measured at the xture level, on axis, at a case temperature of 70°C. GAI may vary
depending on xture design and performance.
4
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2 CRI3
Nominal Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Ecacy
(lm/W)
BXRE-35A4001-B-73 3500 80 93 900 3757 3382 34.3 30.9 121
Notes for Table 2:
1. Nominal CCT is dened by the Lighting Research Center’s Class A denition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal xture level performance, GAI is measured at the xture level, on axis, at a case temperature of 70°C. GAI may vary depending on
xture design and performance.
3. All CRI values are measured at Tj = Tc = 25°C. CRI Values are specied as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on ux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specied temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum ux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
The following product congurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Ecacy
(lm/W)
BXRE-50E4001-B-74 5000 80 900 5355 4820 34.8 31.3 171
BXRE-50E4001-C-74 5000 80 1170 6962 6265 34.8 40.7 171
BXRE-50G4001-B-74 5000 90 900 4549 4094 34.8 31.3 145
BXRE-50G4001-C-74 5000 90 1170 5913 5322 34.8 40.7 145
BXRE-57C4001-B-74 5700 70 900 5516 4965 34.8 31.3 176
BXRE-57C4001-C-74 5700 70 1170 7171 6454 34.8 40.7 176
BXRE-57E4001-B-74 5700 80 900 5293 4764 34.8 31.3 169
BXRE-57E4001-C-74 5700 80 1170 6881 6193 34.8 40.7 169
BXRE-65C4001-B-74 6500 70 900 5613 5052 34.8 31.3 179
BXRE-65C4001-C-74 6500 70 1170 7297 6567 34.8 40.7 179
BXRE-65E4001-B-74 6500 80 900 5387 4848 34.8 31.3 172
BXRE-65E4001-C-74 6500 80 1170 7003 6303 34.8 40.7 172
Notes for Table 1:
1. Nominal CCT as dened by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all oth-
er products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is
93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on ux measurements.
7. Minimum ux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is dened by the Lighting Research Center’s Class A denition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal xture level performance, GAI is measured at the xture level, on axis, at a case temperature of 70°C. GAI may
vary depending on xture design and performance.
5
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Notes for Table 3:
1. Nominal CCT as dened by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum ux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is dened by the Lighting Research Center’s Class A denition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal xture level performance, GAI is measured at the xture level, on axis, at a case temperature of 70°C. GAI may
vary depending on xture design and performance.
Part Number Nominal CCT1
(K) CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Ecacy
(lm/W)
BXRE-17E4000-B-74 1750 80 900 2497 2497 2247 30.6 82
BXRE-20B4001-C-73 2000 65 1170 5473 5473 4926 39.8 138
BXRE-25E4000-B-74 2500 80 900 4036 4036 3632 30.6 132
BXRE-27E4000-B-7X 2700 80 900 4326 4326 3893 30.6 142
BXRE-27E4000-C-7X 2700 80 1170 5624 5624 5061 39.7 142
BXRE-27G40H0-B-7X 2700 90 900 3600 3749 3374 30.6 123
BXRE-27G40H0-C-7X 2700 90 1170 4680 4874 4386 39.7 123
BXRE-27G4000-B-7X 2700 90 900 3136 3600 3240 30.6 118
BXRE-27G4000-C-7X 2700 90 1170 4500 4680 4212 39.7 118
BXRE-27H4000-B-7X 2700 97 900 5850 3136 2822 30.6 103
BXRE-30C4001-B-74 3000 70 900 3745 4961 4465 30.6 162
BXRE-30C4001-C-74 3000 70 1170 4869 6449 5804 39.7 162
BXRE-30E4000-B-7X 3000 80 900 3493 4500 4050 30.6 147
BXRE-30E4000-C-7X 3000 80 1170 3339 5850 5265 39.7 147
BXRE-30G40H0-B-7X 3000 90 900 4645 3918 3526 30.6 128
BXRE-30G40H0-C-7X 3000 90 1170 6039 5094 4584 39.7 128
BXRE-30G4000-B-7X 3000 90 900 3861 3745 3371 30.6 123
BXRE-30G4000-C-7X 3000 90 1170 5020 4869 4382 39.7 123
BXRE-30G400C-B-73 3000 90 900 3636 3493 3144 30.6 114
BXRE-30H4000-B-7X 3000 97 900 4674 3339 3005 30.6 109
BXRE-35E4000-B-7X 3500 80 900 6077 4645 4181 30.6 152
BXRE-35E4000-C-7X 3500 80 1170 4007 6039 5435 39.7 152
BXRE-35G4000-B-7X 3500 90 900 5209 3861 3475 30.6 126
BXRE-35G4000-C-7X 3500 90 1170 5139 5020 4518 39.7 126
BXRE-35A4001-B-738,9 3500 93 900 6681 3636 3273 30.6 119
BXRE-40C4001-B-74 4000 70 900 4820 5081 4573 30.6 166
BXRE-40C4001-C-74 4000 70 1170 6265 6605 5945 39.7 166
BXRE-40E4000-B-7X 4000 80 900 4094 4674 4207 30.6 153
BXRE-40E4000-C-7X 4000 80 1170 5322 6077 5469 39.7 153
BXRE-40G4000-B-7X 4000 90 900 4965 4007 3606 30.6 131
BXRE-40G4000-C-7X 4000 90 1170 6454 5209 4688 39.7 131
BXRE-50C4001-B-74 5000 70 900 4764 5139 4625 30.6 168
BXRE-50C4001-C-74 5000 70 1170 6193 6681 6013 39.7 168
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number Nominal CCT1
(K) CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Ecacy
(lm/W)
BXRE-50E4001-B-74 5000 80 900 4820 4338 33.9 30.6 158
BXRE-50E4001-C-74 5000 80 1170 6265 5639 33.9 39.7 158
BXRE-50G4001-B-74 5000 90 900 4094 3684 33.9 30.6 134
BXRE-50G4001-C-74 5000 90 1170 5322 4790 33.9 39.7 134
BXRE-57C4001-B-74 5700 70 900 4965 4468 33.9 30.6 162
BXRE-57C4001-C-74 5700 70 1170 6454 5809 33.9 39.7 162
BXRE-57E4001-B-74 5700 80 900 4764 4287 33.9 30.6 156
BXRE-57E4001-C-74 5700 80 1170 6193 5574 33.9 39.7 156
BXRE-65C4001-B-74 6500 70 900 5052 4547 33.9 30.6 165
BXRE-65C4001-C-74 6500 70 1170 6567 5911 33.9 39.7 165
BXRE-65E4001-B-74 6500 80 900 4848 4364 33.9 30.6 159
BXRE-65E4001-C-74 6500 80 1170 6303 5673 33.9 39.7 159
Notes for Table 3:
1. Nominal CCT as dened by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. 4. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum ux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is dened by the Lighting Research Center’s Class A denition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal xture level performance, GAI is measured at the xture level, on axis, at a case temperature of 70°C. GAI may
vary depending on xture design and performance.
7
Performance at Commonly Used Drive Currents
V Series LED arrays are tested to the specications shown using the nominal drive currents in Table 1. V Series may also
be driven at other drive currents dependent on specic application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1 & 2 and the ux vs. current
characteristics shown in Figures 3 & 4. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Ecacy
Tc = 25ºC
(lm/W)
BXRE-17E4000-B-74 80
450 33.2 14.9 1467 1344 98
600 33.8 20.3 1923 1758 95
900 34.8 31.4 2774 2497 88
1350 36.3 49.0 4014 3641 82
1800 37.5 67.5 5119 4621 76
BXRE-20B4001-C-73 65
585 33.2 19.4 3132 2759 161
780 33.8 26.3 4102 3595 156
1170 34.8 40.8 6081 5473 149
1755 36.2 63.6 8536 7286 134
2340 37.5 87.6 10864 9112 124
BXRE-25E4000-B-74 80
450 33.2 14.9 2371 2172 159
600 33.8 20.3 3108 2842 153
900 34.8 31.4 4484 4036 143
1350 36.3 49.0 6488 5885 133
1800 37.5 67.5 8274 7469 123
BXRE-27E4000-B-7X 80
450 33.2 14.9 2542 2329 170
600 33.8 20.3 3332 3046 164
900 34.8 31.4 4807 4326 153
1350 36.3 49.0 6955 6309 142
1800 37.5 67.5 8869 8006 131
BXRE-27E4000-C-7X 80
585 33.2 19.4 3218 2835 166
780 33.8 26.3 4215 3694 160
1170 34.8 40.8 6249 5624 153
1755 36.2 63.6 8772 7487 138
2340 37.5 87.6 11164 9363 127
BXRE-27G40H0-B-7X 90
450 33.2 14.9 2203 2018 147
600 33.8 20.3 2887 2640 142
900 34.8 31.4 4166 3749 133
1350 36.3 49.0 6027 5467 123
1800 37.5 67.5 7686 6939 114
BXRE-27G40H0-C-7X 90
585 33.2 19.4 2789 2457 144
780 33.8 26.3 3653 3201 139
1170 34.8 40.8 5415 4874 133
1755 36.2 63.6 7602 6488 120
2340 37.5 87.6 9675 8114 110
BXRE-27G4000-B-7X 90
450 33.2 14.9 2116 1938 142
600 33.8 20.3 2773 2535 137
900 34.8 31.4 4000 3600 128
1350 36.3 49.0 5788 5250 118
1800 37.5 67.5 7381 6663 109
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on ux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Ecacy
Tc = 25ºC
(lm/W)
BXRE-27G4000-C-7X 90
585 33.2 19.4 2678 2360 138
780 33.8 26.3 3508 3074 133
1170 34.8 40.8 5200 4680 128
1755 36.2 63.6 7300 6230 115
2340 37.5 87.6 9291 7792 106
BXRE-27H4000-B-7X 97
450 33.2 14.9 1843 1688 123
600 33.8 20.3 2415 2208 119
900 34.8 31.4 3484 3136 111
1350 36.3 49.0 5041 4573 103
1800 37.5 67.5 6428 5803 95
BXRE-30C4001-B-74 70
450 33.2 14.9 2839 2501 190
600 33.8 20.3 3719 3258 184
900 34.8 31.4 5512 4961 176
1350 36.3 49.0 7738 6604 158
1800 37.5 67.5 9848 8260 146
BXRE-30C4001-C-74 70
585 33.2 19.4 3790 3472 195
780 33.8 26.3 4967 4541 189
1170 34.8 40.8 7166 6449 176
1755 36.2 63.6 10368 9405 163
2340 37.5 87.6 13222 11936 151
BXRE-30E4000-B-7X 80
450 33.2 14.9 2644 2422 177
600 33.8 20.3 3466 3169 171
900 34.8 31.4 5000 4500 159
1350 36.3 49.0 7235 6563 148
1800 37.5 67.5 9226 8329 137
BXRE-30E4000-C-7X 80
585 33.2 19.4 3348 2949 172
780 33.8 26.3 4385 3842 166
1170 34.8 40.8 6500 5850 159
1755 36.2 63.6 9125 7788 143
2340 37.5 87.6 11613 9740 133
BXRE-30G40H0-B-7X 90
450 33.2 14.9 2302 2109 154
600 33.8 20.3 3017 2759 149
900 34.8 31.4 4353 3918 139
1350 36.3 49.0 6299 5714 129
1800 37.5 67.5 8033 7252 119
BXRE-30G40H0-C-7X 90
585 33.2 19.4 2915 2568 150
780 33.8 26.3 3818 3345 145
1170 34.8 40.8 5660 5094 139
1755 36.2 63.6 7945 6781 125
2340 37.5 87.6 10111 8480 115
BXRE-30G4000-B-7X 90
450 33.2 14.9 2201 2016 147
600 33.8 20.3 2884 2637 142
900 34.8 31.4 4161 3745 133
1350 36.3 49.0 6021 5462 123
1800 37.5 67.5 7678 6932 114
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on ux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
9
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Ecacy
Tc = 25ºC
(lm/W)
BXRE-30G4000-C-7X 90
585 33.2 19.4 2786 2455 143
780 33.8 26.3 3650 3198 139
1170 34.8 40.8 5410 4869 133
1755 36.2 63.6 7594 6482 119
2340 37.5 87.6 9665 8106 110
BXRE-30G400C-B-73 90
450 33.2 14.9 2052 1880 137
600 33.8 20.3 2690 2459 133
900 34.8 31.4 3881 3493 124
1350 36.3 49.0 5615 5094 115
1800 37.5 67.5 7161 6465 106
BXRE-30H4000-B-7X 97
450 33.2 14.9 1962 1797 131
600 33.8 20.3 2571 2351 127
900 34.8 31.4 3710 3339 118
1350 36.3 49.0 5368 4869 110
1800 37.5 67.5 6845 6180 101
BXRE-35E4000-B-7X 80
450 33.2 14.9 2730 2501 183
600 33.8 20.3 3577 3271 177
900 34.8 31.4 5162 4645 165
1350 36.3 49.0 7468 6774 153
1800 37.5 67.5 9524 8598 141
BXRE-35E4000-C-7X 80
585 33.2 19.4 3456 3045 178
780 33.8 26.3 4527 3966 172
1170 34.8 40.8 6710 6039 165
1755 36.2 63.6 9419 8039 148
2340 37.5 87.6 11988 10054 137
BXRE-35G4000-B-7X 90
450 33.2 14.9 2269 2079 152
600 33.8 20.3 2974 2719 147
900 34.8 31.4 4291 3861 137
1350 36.3 49.0 6208 5631 127
1800 37.5 67.5 7916 7147 117
BXRE-35G4000-C-7X 90
585 33.2 19.4 2873 2531 148
780 33.8 26.3 3763 3297 143
1170 34.8 40.8 5578 5020 137
1755 36.2 63.6 7830 6683 123
2340 37.5 87.6 9965 8358 114
BXRE-35A4001-B-73 93
450 33.2 14.9 2137 1957 143
600 33.8 20.3 2800 2560 138
900 34.8 31.4 4040 3636 129
1350 36.3 49.0 5846 5303 119
1800 37.5 67.5 7455 6730 110
BXRE-40C4001-B-74 70
450 33.2 14.9 2908 2562 195
600 33.8 20.3 3808 3337 188
900 34.8 31.4 5645 5081 180
1350 36.3 49.0 7925 6764 162
1800 37.5 67.5 10086 8459 149
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on ux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Ecacy
Tc = 25ºC
(lm/W)
BXRE-40C4001-C-74 70
585 33.2 19.4 3881 3555 200
780 33.8 26.3 5087 4651 193
1170 34.8 40.8 7339 6605 180
1755 36.2 63.6 10619 9632 167
2340 37.5 87.6 13541 12225 155
BXRE-40E4000-B-7X 80
450 33.2 14.9 2747 2516 184
600 33.8 20.3 3600 3291 178
900 34.8 31.4 5194 4674 166
1350 36.3 49.0 7515 6817 153
1800 37.5 67.5 9583 8651 142
BXRE-40E4000-C-7X 80
585 33.2 19.4 3478 3064 179
780 33.8 26.3 4555 3991 173
1170 34.8 40.8 6752 6077 166
1755 36.2 63.6 9478 8089 149
2340 37.5 87.6 12063 10117 138
BXRE-40G4000-B-7X 90
450 33.2 14.9 2354 2157 158
600 33.8 20.3 3086 2821 152
900 34.8 31.4 4452 4007 142
1350 36.3 49.0 6441 5843 132
1800 37.5 67.5 8214 7415 122
BXRE-40G4000-C-7X 90
585 33.2 19.4 2981 2626 153
780 33.8 26.3 3904 3421 148
1170 34.8 40.8 5787 5209 142
1755 36.2 63.6 8124 6934 128
2340 37.5 87.6 10340 8672 118
BXRE-50C4001-B-74 70
450 33.2 14.9 3020 2766 202
600 33.8 20.3 3958 3618 195
900 34.8 31.4 5710 5139 182
1350 36.3 49.0 8261 7494 169
1800 37.5 67.5 10535 9511 156
BXRE-50C4001-C-74 70
585 33.2 19.4 3823 3368 197
780 33.8 26.3 5007 4388 190
1170 34.8 40.8 7423 6681 182
1755 36.2 63.6 10420 8893 164
2340 37.5 87.6 13262 11123 151
BXRE-50E4001-B-74 80
450 33.2 14.9 2832 2594 190
600 33.8 20.3 3712 3394 183
900 34.8 31.4 5355 4820 171
1350 36.3 49.0 7748 7028 158
1800 37.5 67.5 9881 8920 146
BXRE-50E4001-C-74 80
585 33.2 19.4 3586 3159 185
780 33.8 26.3 4696 4115 178
1170 34.8 40.8 6962 6265 171
1755 36.2 63.6 9773 8341 154
2340 37.5 87.6 12437 10431 142
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on ux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Ecacy
Tc = 25ºC
(lm/W)
BXRE-50G4001-B-74 90
450 33.2 14.9 2406 2204 161
600 33.8 20.3 3153 2882 156
900 34.8 31.4 4549 4094 145
1350 36.3 49.0 6581 5970 134
1800 37.5 67.5 8393 7577 124
BXRE-50G4001-C-74 90
585 33.2 19.4 3046 2683 157
780 33.8 26.3 3989 3495 151
1170 34.8 40.8 5913 5322 145
1755 36.2 63.6 8301 7085 131
2340 37.5 87.6 10564 8860 121
BXRE-57C4001-B-74 70
450 33.2 14.9 2917 2672 195
600 33.8 20.3 3823 3496 189
900 34.8 31.4 5516 4965 176
1350 36.3 49.0 7981 7240 163
1800 37.5 67.5 10178 9189 151
BXRE-57C4001-C-74 70
585 33.2 19.4 3694 3254 190
780 33.8 26.3 4838 4239 184
1170 34.8 40.8 7171 6454 176
1755 36.2 63.6 10067 8592 158
2340 37.5 87.6 12812 10746 146
BXRE-57E4001-B-74 80
450 33.2 14.9 2799 2564 187
600 33.8 20.3 3669 3354 181
900 34.8 31.4 5293 4764 169
1350 36.3 49.0 7658 6947 156
1800 37.5 67.5 9766 8817 145
BXRE-57E4001-C-74 80
585 33.2 19.4 3544 3122 182
780 33.8 26.3 4642 4067 176
1170 34.8 40.8 6881 6193 169
1755 36.2 63.6 9660 8244 152
2340 37.5 87.6 12293 10311 140
BXRE-65C4001-B-74 70
450 33.2 14.9 2969 2719 199
600 33.8 20.3 3890 3557 192
900 34.8 31.4 5613 5052 179
1350 36.3 49.0 8121 7367 166
1800 37.5 67.5 10357 9350 153
BXRE-65C4001-C-74 70
585 33.2 19.4 3759 3311 194
780 33.8 26.3 4923 4313 187
1170 34.8 40.8 7297 6567 179
1755 36.2 63.6 10244 8743 161
2340 37.5 87.6 13037 10934 149
BXRE-65E4001-B-74 80
450 33.2 14.9 2849 2610 191
600 33.8 20.3 3734 3414 184
900 34.8 31.4 5387 4848 172
1350 36.3 49.0 7794 7070 159
1800 37.5 67.5 9940 8973 147
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on ux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Ecacy
Tc = 25ºC
(lm/W)
BXRE-65E4001-C-74 80
585 33.2 19.4 3607 3178 186
780 33.8 26.3 4724 4140 179
1170 34.8 40.8 7003 6303 172
1755 36.2 63.6 9831 8390 155
2340 37.5 87.6 12512 10494 143
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on ux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Electrical Characteristics
Table 5: Electrical Characteristics
Part Number Drive Current
(mA)
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical
Coecient
of Forward
Voltage4
Vf/Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Minimum Typical Maximum
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
BXRE-xxx400x-B-7x
900 32.2 34.8 37.5 -14.5 0.15 31.1 38.4
1800 34.7 37.5 40.3 -14.5 0.18 33.5 41.2
BXRE-xxx400x-C-7x
1170 32.2 34.8 37.5 -14.5 0.11 31.1 38.4
2340 34.6 37.5 40.3 -14.5 0.13 33.5 41.2
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coecient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The work-
ing voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.
14
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classications
Part Number
Drive
Current 5
(mA)
CCT1,5
2700K/3000K 4000K25000K36500K4
BXRE-xxx400x-B-7x
900 RG1 RG1 RG1 RG1
1350 RG1 RG1 RG1 RG2
1800 RG1 RG1 RG2 RG2
BXRE-xxx400x-C-7x
1170 RG1 RG1 RG1 RG1
1755 RG1 RG1 RG2 RG2
2340 RG1 RG1 RG2 RG2
Notes for Table 6:
1. Eye safety classication for the use of Bridgelux V Series LED arrays is in accordance with specication IEC/TR 62778: Application of IEC 62471 for the assess-
ment of blue light hazard to light sources and luminaires.
2. For products classied as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classied as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classied as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specic drive currents and CCTs not listed.
15
Absolute Maximum Ratings
Parameter Maximum Rating
LED Junction Temperature (Tj)125°C
Storage Temperature -40°C to +105°C
Operating Case Temperature1 (Tc)105°C
Soldering Temperature2300°C or lower for a maximum of 6 seconds
BXRE-xxx400x-B-7x BXRE-xxx400x-C-7x
Maximum Drive Current31800mA 2340mA
Maximum Peak Pulsed Drive Current42570mA 3340mA
Maximum Reverse Voltage5-60V -60V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specied. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
Table 7: Maximum Ratings
16
Performance Curves
Figure 3: V18B Typical Relative Flux vs. Current Figure 4: V18C Typical Relative Flux vs. Current
Notes for Figures 1-4:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming eects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
Figure 1: V18B Drive Current vs. Voltage Figure 2: V18C Drive Current vs. Voltage
0
200
400
600
800
1000
1200
1400
1600
1800
2000
32 33 34 35 36 37 38
Forward Current (mA)
Forward Voltage (V)
0
250
500
750
1000
1250
1500
1750
2000
2250
2500
32 33 34 35 36 37 38
Forward Current (mA)
Forward Voltage (V)
0%
20%
40%
60%
80%
100%
120%
140%
160%
180%
200%
0200 400 600 800 1000 1200 1400 1600 1800 2000
Relative Luminous Flux
Forward Current (mA)
0%
20%
40%
60%
80%
100%
120%
140%
160%
180%
200%
0250 500 750 1000 1250 1500 1750 2000 2250 2500
Relative Luminous Flux
Forward Current (mA)
17
Performance Curves
Figure 5: Typical DC Flux vs. Case Temperature
82%
85%
88%
91%
94%
97%
100%
103%
025 50 75 100 125
Relative Luminous Flux
Case Temperature (°C)
Warm White
Neutral White
Cool White
25°C Pulsed
Notes for Figures 5-7:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
Figure 7: Typical DC ccx Shift vs. Case Temperature
Figure 6: Typical DC ccy Shift vs. Case Temperature
-0.012
-0.010
-0.008
-0.006
-0.004
-0.002
0.000
025 50 75 100 125
ccx Shift
Case Temperature (°C)
Warm White
Neutral White
Cool White
25°C Pulsed
-0.015
-0.012
-0.009
-0.006
-0.003
0.000
0.003
025 50 75 100 125
ccy Shift
Case Temperature (°C)
Warm White
Neutral White
Cool White
25°C Pulsed
Figure 8: 1750K Color Shift vs. Case Temperature1
0.368
0.3685
0.369
0.3695
0.37
0.3705
0.5196 0.5198 0.52 0.5202 0.5204 0.5206
ccy
ccx
15°C
25°C
45°C
70°C
85°C
105°C
Pulsed Center Point
Tc = 25°C
18
Performance Curves
Figure 11: 2700K, 97 CRI Color Shift vs. Case Temperature1
Figure 13: 3000K, 97 CRI Color Shift vs. Case Temperature1 Figure 14: 3500K Class A Color Shift vs. Case Temperature1
Note for Figures 8-14:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Characteristics shown for Decor Series Showcase products, BXRE-30G400C-x-73
Figure 10: 2500K Color Shift vs. Case Temperature1
0.4105
0.411
0.4115
0.412
0.4125
0.413
0.4135
0.414
0.4145
0.468 0.47 0.472 0.474 0.476 0.478
ccy
ccx
15°C
25°C
45°C
70°C
85°C
105°C
Pulsed
Center Point
Tc = 25°C
15°C
25°C
45°C
65°C
85°C
105°C
Pulsed Center
Point
Tc= 25°C
0.4030
0.4040
0.4050
0.4060
0.4070
0.4080
0.4090
0.4100
0.4110
0.457 0.4572 0.4574 0.4576 0.4578 0.458
ccy
ccx
15°C
25°C
45°C
70°C
85°C
105°C
Pulsed Center
Point
Tc= 25°C
0.3950
0.3970
0.3990
0.4010
0.4030
0.4050
0.4323 0.4328 0.4333 0.4338 0.4343 0.4348 0.4353
ccy
ccx
0.358
0.36
0.362
0.364
0.366
0.368
0.37
0.392 0.393 0.394 0.395 0.396 0.397
ccy
ccx
Pulsed
Center Point
Tc=25°C
15°C
45°C
85°C
105°C
70°C
25°C
Figure 12: 3000K, 90 CRI Color Shift vs. Case Temperature3
Figure 9: 2000K, 65 CRI Color Shift vs. Case Temperature
105°C
85°C
65°C
45°C
25°C
15°C
Pulsed Center
Point Tc=25°C
0.409
0.4091
0.4092
0.4093
0.4094
0.4095
0.4096
0.4097
0.4098
0.4099
0.41
0.4101
0.525 0.526 0.527 0.528 0.529 0.53 0.531 0.532
ccy
ccx
Pulsed Center
Point Tc=25°C
15°C
25°C
45°C
65°C
85°C
105°C
0.395
0.396
0.397
0.398
0.399
0.4
0.401
0.402
0.403
0.444 0.4445 0.445 0.4455 0.446 0.4465 0.447
ccy
ccx
19
Typical Radiation Pattern
Figure 15: Typical Spatial Radiation Pattern
Figure 16: Typical Polar Radiation Pattern
Note for Figure 15:
1. Typical viewing angle is 120.
2. The viewing angle is dened as the o axis angle from the centerline where intensity is ½ of the peak value.
20
Typical Color Spectrum
Figure 17: Typical Color Spectrum
Note for Figure 17:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
110%
400 450 500 550 600 650 700 750 800
Relative Spectral Power Distribution
Wavelength (nm)
3000K
4000K
5000K
6500K
Figure 18: Typical Color Spectrum for Décor Series
Note for Figure 18:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
400 450 500 550 600 650 700 750 800
Relative Spectral Power Distribution
Wavelength (nm)
17E
20B
25E
27H
30G (Décor Series Showcase)
30H
21
Mechanical Dimensions
Figure 19: Drawing for V18 LED Array
Notes for Figure 19;
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specied, tolerances are ±0.1mm.
4. Solder pad labeled “+” denotes positive contact.
5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations.
6. The optical center of the LED Array is nominally dened by the mechanical center of the array to a tolerance of ± 0.2mm.
7. Bridgelux maintains a atness of 0.10mm across the mounting surface of the array.
22
Figure 20: Warm and Neutral White Test Bins in xy Color Space
Figure 21: Graph of Cool White Test Bins in xy Color Space
Color Binning Information
Bin Code 1750K 2000K 2500K 2700K 3000K13500K14000K1
ANSI Bin
(for reference only) ---(2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K)
73 (3 SDCM) ---(2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K)
72 (2 SDCM) ---(2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K)
Center Point (x,y) (0.5167, 0.336) (0.5280, 0.4100) (0.4765, 0.4137) (0.4578, 0.4101) (0.4338, 0.403)
(0.4465, 0.4024)2(0.4073, 0.3917) (0.3818, 0.3797)
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code 5000K 5700K 6500K
ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K)
74 (4 SDCM) (4801K - 5282K) (5829K - 5481K) (6270K - 6765K)
73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K)
Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282)
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Note for Table 8:
1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
2. Center Point for Decor Series Showcase.
0.34
0.36
0.38
0.4
0.42
0.44
0.36 0.39 0.42 0.45 0.48 0.51 0.54
Y
X
3 SDCM
4 SDCM
3500K
2500K
4SDCM
1750K
4SDCM
2000K
3SDCM
2700K
3000K
4000K
0.3
0.31
0.32
0.33
0.34
0.35
0.36
0.37
0.38
0.39
0.3 0.31 0.32 0.33 0.34 0.35 0.36
Y
X
4 SDCM
3 SDCM
6500K
5700K
23
Packaging and Labeling
Figure 22: Drawing for V18 Packaging Tube
Notes for Figure 22:
1. Each tube holds 20 V18 COB arrays.
2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four
boxes may be used to ship products.
3. Each bag and box is to be labeled as shown above.
4. Dimensions for each tube are 26.3 (W) x 9.5(H) x 510 (L). Dimensions for the anti-static bag are 75 (W) x 615 (L) x 3.1 (T) mm. Dimensions for the shipping
box are 58.7 x 13.3 x 7.9 cm
24
Packaging and Labeling
Figure 23: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identication. In
addition to the product identication markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number 30E4000C 73 2F Customer Use- Vf Bin Code
included to enable greater
luminaire design exibility.
Refer to AN92 for bin code
denitions.
25
Design Resources
Disclaimers
Precautions
Application Notes
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the V Series
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Optical Source Models
Optical source models and ray set les are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
MINOR PRODUCT CHANGE POLICY
The rigorous qualication testing on products oered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not aect form, t, or function
may occur as Bridgelux continues product optimization.
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN101 for additional information.
CAUTION: RISK OF BURN
Do not touch the V Series LED array during operation.
Allow the array to cool for a sucient period of time
before handling. The V Series LED array may reach
elevated temperatures such that could burn skin when
touched.
3D CAD Models
Three dimensional CAD models depicting the product
outline of all Bridgelux V Series LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
LM80
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales
representative for LM-80 report.
STANDARD TEST CONDITIONS
Unless otherwise stated, array testing is performed
at the nominal drive current.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reectors must not be mounted in contact
with the LES (yellow phosphor resin area).
26
About Bridgelux: Bridging Light and Life™
© 2018 Bridgelux, Inc. All rights reserved 2018. Product specications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are
registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 V18 Array Series Product Data Sheet DS102 Rev. M (09/2018)
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy ecient,
cost eective and easy to integrate. Our focus is on light’s impact on human behavior, deliver-
ing products that create better environments, experiences and returns—both experiential and
nancial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina