111-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
JWS508 Series
Features
u 5 Year Warranty
u Power factor Corrected
u Approved to UL508
u Universal Input (85 - 265VAC)
u 200% Peak power capable (JWS-P models)
u Level B EMI
Key Market Segments & Applications
u Factory Automation Process Control, NC-Machining,
Automotive, Packaging Equipment,
Chemical Processing, Robots
Single Output Industrial Power Supplies
JWS70P JWS120P JWS240P JWS480P
Model JWS50 JWS75 JWS100 JWS150 JWS300 JWS600
Input Voltage range - 85 - 265VAC (47 - 63Hz) or 120 - 330VDC (no DC input on JWS-P)
Inrush Current (100 / 200VAC) A 14 / 28 25 / 50 20 / 40
Power Factor - Meets EN61000-3-2
Temperature Coeffi cient - <0.02%/°C
Overcurrent Protection - >105%
Overvoltage Protection V Yes
Hold Up Time (Typ) ms 20
Leakage Current (max) mA 0.75
Remote Sense - No Yes
Remote On / Off - Not Available Standard
AC Power Fail - Not Available Standard
Parallel Connection - Not Available Avail. JWS300 & 600 only
Operating Temperature - See derating table
Storage Temperature °C -30 to +85°C
Operating Humidity (1) - 30 - 90% RH (10 - 90% RH on JWS300 & 600 only)
Storage Humidity (1) - 10 - 95% RH
Cooling - JWS50 - JWS150 Convection, JWS240 - JWS600 Internal fan
Withstand Voltage - Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA)
Output to Ground 500VAC (100mA) for 1 min.
Isolation Resistance - >100M at 25C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock - < 196.1 m/s2
Safety Agency Approvals - UL508
Conducted & Radiated EMI EN55011 / EN55022-B, FCC Class B, VCCI-B
Weight (Typ) g 400 500 700 900 1900 3000
Recommended EMI Filter - MAW1202-22 MAW1202-22 MAW1205-22 MB1210
MAW1203-22 MB1210 MB1216
Size (WxHxD) mm See sheet 2
Cover - Standard
Warranty - Five Years
Specifi cations
Not recommended for new designs - see HWS series
(1) Non condensing
121-800-526-2324 • www.us.tdk-lambda.com/lp/ Revision A7: Feb 2012
JWS508 Series
For Additional Information, please visit
us.tdk-lambda.com/lp/products/jws-series.htm See website for detailed drawing.
HWS 15 to 1500W Single output
JWS, JWS-P & JWT 50 to 600W Single and triple output
LZSa 500 to 1500W Single output
JFS 500 to 2000W Single output
DLP/DSP/DPP 10 to 480W DIN Rail Mount
Other Industrial Products
JWS Outline Drawing
Code Wattage Max Slots Size (H x W x L) Input Voltage
CA1500 1500 8 2.5” x 8” x 11” 150 - 264VAC
1 Case Codes
FRONT VIEW
SIDE VIEW
H
H
W
D
W
(BOTH SIDES)
MOUNTING SURFACE
Model 40°C 45°C 50°C 55°C 60°C 65°C
JWS50-24/508 100% 100% 80% 60% - -
JWS70P-24/508 100% 100% 100% 80% 60% -
JWS75-24/508 100% 80% 60% - - -
JWS100-24/508 100% 100% 100% 60% - -
JWS120P-24/508 100% 100% 100% 80% 60% -
JWS150-24/508 100% 100% 100% 60% - -
JWS240P-24/508 100% 100% 100% 85% 70% 55%
JWS300-24/508 100% 100% 100% 85% 70% 55%
JWS480P-24/508 100% 100% 100% 85% 70% 55%
JWS600-24/508 100% 100% 100% 85% 70% 55%
* % of full power rating at specifi ed temperature
Height (H) Width (W) Depth (D)
JWS50 1.45” 3.35” 6.25”
JWS75 1.65” 3.62” 6.88”
JWS70P, JWS100 1.97” 3.62” 7.40”
JWS120P, JWS150 2.56” 3.62” 7.80”
JWS240P, JWS300 3.62” 4.72” 7.48”
JWS480P, JWS600 3.62” 6.29” 7.90”
Model Derating*
Dimensions Table
Max Avg. Peak Load Line Ripple Effi ciency
Model Voltage Adjustment Range Current Current Current Reg mV Reg mV Noise mV (typ) %
JWS50-24/508 24V 21.6 - 26.4 2.2 - - 150 96 150 79
JWS70P-24/508 24V 21.6 - 26.4 - 3 6 192 96 240 80
JWS75-24/508 24V 21.6 - 26.4 3.2 - - 150 96 150 79
JWS100-24/508 24V 21.6 - 26.4 4.5 - - 150 96 150 79
JWS120P-24/508 24V 21.6 - 26.4 - 5 10 192 96 240 80
JWS150-24/508 24V 21.6 - 26.4 6.5 - - 150 96 150 80
JWS240P-24/508 24V 21.6 - 28.8 - 10 20 192 96 240 80
JWS300-24/508 24V 21.6 - 28.8 14 - - 144 96 150 80
JWS480P-24/508 24V 21.6 - 28.8 - 20 40 192 96 240 80
JWS600-24/508 24V 21.6 - 28.8 27 - - 144 96 150 82
Note 1: Peak current for up to 10 seconds with a 50% duty cycle
Model Selector
Not recommended for new designs - see HWS series