www.clare.com
2
LAA110L
Rev. 7.0
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
Electrical Characteristics
Absolute Maximum Ratings (@ 25˚ C)
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 50 mA
Peak (10ms) - - 1 A
Blocking Voltage DC or AC peak - - 350 V
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 8002mW
Isolation Voltage
Input to Output 3750 - - VRMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
(10 Seconds Max.)
DIP Package - - +260 °C
Flatpack/Surface Mount
Package - - +220 °C
1Derate Linearly 1.33 mw/˚C
2Derate Linearly 6.67 mw/˚C
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current (Continuous)* - IL- - 120 mA
Peak Load Current 10ms max ILPK - - 350 mA
On-Resistance IL=120mA RON -3035Ω
Off-State Leakage Current VL=350V ILEAK --1µA
Switching Speeds
Turn-On IF=5mA, VL=10V TON --3ms
Turn-Off IF=5mA, VL=10V TOFF --3ms
Output Capacitance 50V; f=1MHz COUT -25-pF
Load Current Limiting - ICL 130 170 210 mA
Input Characteristics @ 25°C
Input Control Current IL=120mA IF5-50mA
Input Dropout Current - - 0.4 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Voltage - VR--5V
Reverse Input Current VR=5V IR- - 10 µA
Input to Output Capacitance - CI/O -3-pF
*Note: If both poles operate load current must be derated so as not to exceed the package power dissipation valve.