2007/08 EDITION MAGNETIC COMPONENTS SELECTOR GUIDE
We reserve the right to change specifications without prior notice
www.bitechnologies.com
81
HM76-101R0JLF 1.0 0.03 2.90 A 1
HM76-101R5JLF 1.5 0.05 2.80 A 1
HM76-102R2JLF 2.2 0.06 2.40 A 1
HM76-103R3JLF 3.3 0.09 2.00 A 1
HM76-104R7JLF 4.7 0.09 1.50 A 1
HM76-106R8JLF 6.8 0.17 1.30 A 1
HM76-10100JLF 10 0.16 1.10 A 1
HM76-10150JLF 15 0.30 0.80 A 1
 22 0.43 0.70 A 1
HM76-10330JLF 33 0.69 0.57 A 1
HM76-10470JLF 47 0.92 0.46 A 1
HM76-10680JLF 68 1.39 0.37 A 1
HM76-10101JLF 100 1.98 0.28 A 1
HM76-10151JLF 150 3.08 0.22 A 1
HM76-10221JLF 220 4.47 0.18 A 1
HM76-10331JLF 330 6.90 0.15 A 1
HM76-10471JLF 470 11.55 0.12 A 1
HM76-20100JLF 10 0.07 2.00 A 3
HM76-20150JLF 15 0.09 1.50 A 3
HM76-20220JLF 22 0.15 1.30 A 3
HM76-20330JLF 33 0.21 1.10 A 3
HM76-20470JLF 47 0.31 0.80 A 3
HM76-20680JLF 68 0.42 0.70 A 3
HM76-20101JLF 100 0.58 0.60 A 3
HM76-20151JLF 150 0.89 0.50 A 3
HM76-20221JLF 220 1.30 0.40 A 3
HM76-20331JLF 330 2.00 0.30 A 3
HM76-20471JLF 470 2.50 0.20 A 3
HM76-20681JLF 680 3.50 0.10 A 3
HM76-20102JLF 1,000 6.00 0.05 A 3
Specifications (Case Size 10 and 20)
DC Resistance Rated
Part Inductance @ 25°C (3) Current (2,4)
Number µH ± 20% (1) Max Amps Schematic Figure
Schematics
Schematic A Schematic B
Specifications (Case Size 30 and 40)
DC Resistance Rated
Part Inductance @ 25°C (3) Current (2,4)
Number µH ± 20% (1) Max Amps Schematic Figure
HM76-301R0JLF 1.0 0.01 8.50 A 1
HM76-301R5JLF 1.5 0.01 7.90 A 1
HM76-302R2JLF 2.2 0.02 7.40 A 1
HM76-303R3JLF 3.3 0.02 6.60 A 1
HM76-304R7JLF 4.7 0.02 6.00 A 1
HM76-306R8JLF 6.8 0.03 5.20 A 1
HM76-308R2JLF 8.2 0.03 5.00 A 1
1
2
1
2
3
4
Operating Temperature Range -40°C to +125°C
Ambient Temperature, Maximum 80°C
Insulation System Class B, 130°C
Temperature Rise, Maximum 40°C

Electrical / Environmental
Drum Core, Space Efficient High Performance
Surface Mount Inductors
RoHS
Compliant
Last Updated: 14 June 2007
www.bitechnologies.com
MAGNETIC COMPONENTS SELECTOR GUIDE 2007/08 EDITION
We reserve the right to change specifications without prior notice.
82
HM76-30100JLF 10 0.04 4.60 A 1
HM76-30150JLF 15 0.05 3.70 A 1
HM76-30220JLF 22 0.07 3.10 A 1
HM76-30330JLF 33 0.11 2.50 A 1
HM76-30470JLF 47 0.16 2.00 A 1
HM76-30680JLF 68 0.20 1.80 A 1
HM76-30820JLF 82 0.24 1.58 A 1
HM76-30101JLF 100 0.30 1.50 A 1
HM76-30151JLF 150 0.44 1.20 A 1
HM76-30221JLF 220 0.64 1.00 A 1
HM76-30331JLF 330 1.00 0.80 A 1
HM76-30471JLF 470 1.50 0.50 A 1
HM76-30681JLF 680 2.20 0.40 A 1
HM76-30102JLF 1,000 3.15 0.30 A 1
HM76-403R3JLF 3.3 0.01 9.80 B 2
HM76-404R7JLF 4.7 0.01 9.30 B 2
HM76-406R8JLF 6.8 0.02 7.70 B 2
HM76-408R2JLF 8.2 0.02 7.00 B 2
HM76-40100JLF 10 0.02 6.50 B 2
HM76-40150JLF 15 0.03 5.30 B 2
HM76-40220JLF 22 0.04 4.40 B 2
HM76-40330JLF 33 0.06 3.50 B 2
HM76-40470JLF 47 0.07 3.00 B 2
HM76-40680JLF 68 0.11 2.50 B 2
HM76-40820JLF 82 0.12 2.20 B 2
HM76-40101JLF 100 0.15 2.00 B 2
HM76-40151JLF 150 0.22 1.70 B 2
HM76-40221JLF 220 0.33 1.30 B 2
HM76-40331JLF 330 0.45 1.10 B 2
HM76-40471JLF 470 0.70 0.93 B 2
HM76-40681JLF 680 1.00 0.78 B 2
HM76-40102JLF 1,000 1.45 0.65 B 2
HM76-50R78JLF 0.78 0.003 15.0 A 3
HM76-501R3JLF 1.3 0.0043 13.7 A 3
HM76-502R2JLF 2.2 0.006 12.0 A 3
HM76-503R3JLF 3.3 0.008 9.80 A 3
HM76-505R6JLF 5.6 0.010 7.50 A 3
HM76-50100JLF 10 0.023 6.00 A 3
HM76-50150JLF 15 0.035 4.50 A 3
HM76-50220JLF 22 0.045 4.00 A 3
HM76-50330JLF 33 0.075 3.00 A 3
HM76-50470JLF 47 0.096 2.60 A 3
HM76-50680JLF 68 0.140 2.30 A 3
HM76-50101JLF 100 0.190 1.70 A 3
HM76-50151JLF 150 0.290 1.50 A 3
HM76-50221JLF 220 0.410 1.20 A 3
HM76-50331JLF 330 0.540 1.00 A 3
HM76-50471JLF 470 0.800 0.83 A 3
HM76-50681JLF 680 1.150 0.72 A 3
HM76-50102JLF 1,000 1.800 0.56 A 3
Notes: (1) Inductance is measured at 100kHz, 0.1 Vrms, without DC current.
(2) Rated DC current at which inductance will be decreased by 10% from its initial value or the DC current
at which T = 40°C, whichever is smaller.
(3) Resistance is measured with both windings connected in parallel (case size 40 only).
(4) Rated current will be decreased by 50% when parts are connected as coupled inductors.
Specifications (Case Size 30 and 40)
DC Resistance Rated
Part Inductance @ 25°C (3) Current (2,4)
Number µH ± 20% (1) Max Amps Schematic Figure
Specifications (Case Size 50)
DC Resistance Rated
Part Inductance @ 25°C (3) Current (2,4)
Number µH ± 20% (1) Max Amps Schematic Figure
2007/08 EDITION MAGNETIC COMPONENTS SELECTOR GUIDE
We reserve the right to change specifications without prior notice
www.bitechnologies.com
83
Packaging
Standard: Embossed Tape and Reel
All units orientated with lead #1 to the same side of sprocket hole.
Reel: Diameter: Case size 10 = 7” (177.8mm)
All Other Case Sizes = 13” (330.2mm)
Capacity: Case size 10 = 500 Units
Case size 20 = 1,000 Units
Case size 30 = 350 Units
Case size 40 = 200 Units
Case size 50 = 200 Units
Ordering Information
Inductance Code:
First 2 digits are significant. Last digit
denotes the number of trailing zeros.
Model Series
Case Size:
10 (Figure 1) 40 (Figure 2)
20 (Figure 3) 50 (Figure 3)
30 (Figure 1)
Termination Type
HM76 20 100 J LF TR13
Outline Dimensions (Inch/mm)
Figure 1
( Case Size: 10 & 30 )
Figure 2
( Case Size: 40 )
Figure 3
( Case Size: 20 & 50 )
Recommended Solder Pad Layout
(1) For Case Size: 10, 20, 30 & 50
(2) For Case Size: 40
Lead-Free
TR: Tape & Reel
Packing
7 – 7” reel
13 – 13” reel