Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
SPECIFICATION
MODEL T-60A T-60B T-60C
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V
CH2
-5V
CH3
5V
CH1
12V
CH2
-12V
CH3
5V
CH1
15V
CH2
-15V
CH3
5A 2.5A 0.5A 5A 2.5A 0.5A 5A 2A 0.5A
0.5~7A 0.2~3.5A 0~1A 0.5~7A 0.2~3.5A 0~1A 0.5~7A 0.2~3A 0~1A
57.5W 61W 62.5W
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
CH1:4.75~5.5V CH1:4.75~5.5V CH1:4.75~5.5V
2.0% 6.0% 6.0% 2.0% 6.0% 6.0% 2.0% 6.0% 6.0%
0.5% 1.0% 0.5% 0.5% 1.0% 0.5% 0.5% 1.0% 0.5%
1.0% 4.0% 1.0% 1.0% 4.0% 1.0% 1.0% 4.0% 1.0%
300ms,50ms/230VAC 800ms,50ms/115VACatfullload
80ms/230VAC 10ms/115VACatfullload
85~264VAC120~370VDC
47~63Hz
72% 72% 72%
5V:5.75~6.75V
2A/115VAC1A/230VAC
COLDSTART 20A/115VAC40A/230VAC
<3.5mA /240VAC
105~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL1012,UL60950, TUVEN60950 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,Lightindustrylevel,criteria A
-10~+60 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )on+5Voutput
10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
281.1Khrsmin.MIL-HDBK-217F(25 )
159*97*38mm(L*W*H)
FileName:T-60-SPEC2005-09-13
0.55Kg;24pcs/14.1Kg/0.75CUFT
60W TripleOutputSwitchingPowerSupply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
Fixed switching frequency at 50KHz
2 years warranty
Features :
T-60 series
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
EMICONDUCTION&RADIATION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
CH1
OUTPUTNUMBER
MechanicalSpecification
StaticCharacteristics(B)
FileName:T-60-SPEC2005-09-13
AMBIENTTEMPERATURE( ) INPUTVOLTAGE(V)60Hz
LOAD(%)
OUTPUTVOLTAGE(V)
OUTPUTRIPPLE(mVp-p)
-12V
+5V
60 80 120100 180 200160140 220 260240
13
7
9
8
12
11
10
300
250
200
100
150
50
25
4.8
5.0
5.2
4.4
4.6
4.2
4.0
+12V
+12V
+5V
-12V
Ta=25
OutputDerating
-10
-10
0
0
2010 30 40
20
40
80
60
100
60
55
50
45 (HORIZONTAL)
(VERTICAL)
4.5
9
152.5
3.5
97
84.5
3.5
65
9.5
8.2
3.5
3.5
2-M3
7
150
6.5
18.5
78
24
159
22 117
9
7
6
5
4
3
2
1
28.5
18
3-M3
38
CaseNo.901Unit:mm
TerminalPin.No Assignment
PinNo. PinNo. PinNo.
1
2
4
3
5
6
7
Assignment Assignment Assignment
DCOUTPUT -V
DCOUTPUT +V2
DCOUTPUT COM
DCOUTPUT +V1
FG
AC/L
AC/N
60W TripleOutputSwitchingPowerSupply T-60 se r i e s