Weekly/Yearly Timer LE365S-41 W48xH48mm, Weekly/Yearly timer (A) Photo electric sensor Features (B) Fiber optic sensor Easy to check and change the program setting Customizable weekly or yearly unit time setting and control by user Includes daylight saving time function 1 independent control output.(Relay) Flush and surface, DIN rail mounting are in one unit. (C) Door/Area sensor (D) Proximity sensor (E) Pressure sensor Please read "Caution for your safety" in operation manual before using. (F) Rotary encoder Ordering information LE365 S 4 (G) Connector/ Socket 1 Output Power supply Size Item 1 1 Relay outputs 4 100-240VAC S DIN W48xH48mm LE365 Weekly/Yearly timer (H) Temp. controller (I) SSR/ Power controller (J) Counter Specifications Model (K) Timer LE365S-41 Power supply 100-240VAC 50/60 Allowable voltage range 90 to 110% of rated voltage Power consumption 2.4VA Timing program 48 steps for weekly, 24 steps for yearly Operation mode ON/OFF mode, cycle mode, pulse mode Mounting Panel flush, surface, DIN rail Time deviation 15sec/month(25) (4sec/week) Temperature error 0.01% 0.05sec. Memory protection Over 5 years(at 25) Control Output Contact type SPST(Single Pole Single Throw) Contact capacity 250VAC 15A resistive load Output number Independent 1 output(1a) Mechanical Relay life cycle Electrical Min. 5,000,000 operations(Switching capacity 30 times/minute) Insulation resistance Min. 100M(at 500VDC megger) Dielectric strength 2000VAC 50/60Hz for 1minute Noise strength 2kV the square wave noise(pulse width : 1) by the noise simulator Environ -ment (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller (P) Switching mode power supply (Q) Stepper motor& Driver&Controller 50,000 operations (R) Graphic/ Logic panel Ambient temperature -10 to 55, storage: -25 to 65 Ambient humidity Unit weight (S) Field network device 35 to 85%RH, storage: 35 to 85%RH Approx. 110g (T) Software Environment resistance is rated at no freezing or condensation. Connections 1 (U) Other 2 CONTACT OUT: 250VAC 15A RESISTIVE LOAD 3 4 SOURCE: 100-240VAC 50/60 K-87 LE365S-41 Dimensions & Mounting 1) Front panel mounting 6.8 6 48 (unit: mm) Panel cut-out 60 Min. 55 45 +0.6 0 61 44.8 Min. 65 2) Surface mounting Panel hole cut-out 4 16 45 +0.6 0 Panel 59 61.5 2-M3 TAP Fix the Weekly/Yearly timer on the panel with M3 tapping screws. 42.7 3) DIN rail mounting 48 3 61 35 66 DIN rail 43 How to switch from the flush mounting to surface or DIN rail mounting type Remove terminals from the body after unscrewing terminals screws, and then assemble terminals to the body after rotating terminals as shown below. Unscrew 1 bolts from terminal block (front panel mounting) To raise panel holder, tools must be used. (surface mounting type) K-88 Detach the terminal block after unscrew terminal screws with tools. Screw terminals block with a fixing bolt. (DIN rail type) Detach terminal block from case and rotate it 180degree. Assemble case and terminal block Weekly/Yearly Timer Parts description (A) Photo electric sensor 10 1 2 (B) Fiber optic sensor 11 12 3 4 5 6 7 13 (C) Door/Area sensor 14 (D) Proximity sensor 15 16 8 9 17 18 (E) Pressure sensor (F) Rotary encoder 19 20 1. Day indicator 2. Day display Light : Day is selected. Light-out : Day is not selected. 3. Current time setting mode indicator 4. DST display(Daylight saving time) 5. AM/PM display(Main display) 6. Season display 7. Program display 8. Display ON time/day, OFF time/day, ON time width, OFF time width 9. AM/PM display(Sub-display) 10. YEAR display : It turns ON when set, check, modify, delete yearly program, set yearly holidays and operate yearly program. 11. Yearly START/STOP day display 12. Main display 21 22 23 (G) Connector/ Socket 13. Remaining step display 14. Operation mode display 15. Output mode display 16. Year, month, date display 17. Unit of pulse width display 18. Sub display 19. CHECK key 20. MODE key 21. Operation key : Press +1h key over 3sec. in RUN mode, DST mode is set and released. 22. SET key 23. Output selection switch AUTO : Control output according to the set program. ON : Output is ON.(Operation) OFF : Output is OFF.(Block) Record: A part of program that controls output operation. Step: Basic component of Record. Operation modes If the operation mode of Program1 (program2) is set on pulse mode initially, the pulse mode is fixed for additional programs. If the operation mode of Program1 (program2) is set on ON/OFF or cycle mode initially, pulse mode cannot be used for additional pulse programs. If the weekly operation mode is set on ON/OFF or cycle mode, the yearly operation mode is fixed on ON/OFF mode. If the yearly operation mode is set on ON/OFF, the weekly operation mode is fixed on ON/OFF or cycle mode. If the weekly operation mode is set on pulse mode, the yearly operation mode is fixed on pulse mode. If the yearly operation mode is set on pulse mode, the weekly operation mode is fixed on pulse. (I) SSR/ Power controller (J) Counter (K) Timer (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller Functions Definitions (H) Temp. controller (P) Switching mode power supply Weekly ON/OFF mode Output operation by ON/OFF set time. * Min. time setting unit : 1 min. * It is able to set ON/OFF day separately. * One record in two steps (ON day/ON time, OFF day/OFF time) ON Time (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device OFF Time Weekly Cycle operation It outputs ON the set ON time width which is from Cycle operation ON time to Cycle operation OFF time, and it outputs OFF the set OFF time width. (T) Software (U) Other K-89 LE365S-41 Power restore mode * Set range for ON/OFF time width : 1min. to 12 hour 59min. * One record in 3 steps(ON day/ON time, OFF day/OFF time, ON time width/OFF time width) In setting group 2 - LEVEL2 (RET turns ON, AT or NOR flashes), select Auto[AT] or Normal [NOR] by or key and press SET key to set. Auto [AT] power restore mode Output operates according to program when power turns ON again after power failure. Normal[NOR] power restore mode When power turns ON again after power failure, output is kept OFF and rIN flashes on the lower row of screen and power restore input (press SET key over 3 sec. in RUN mode) is applied, rIN turns OFF and output operates according to program. OFF width ON Time ON width OFF Time Weekly pulse mode Output turns ON at ON time for a specified pulse width. (Pulse width : 1 to 59sec., 1 to 60min.) * One record in two steps(ON day/ON time, pulse width) Season switching mode Pulse width (1 to 59sec., 1 to 60min.) ON time Yearly ON/OFF mode Output turns ON at ON time on START date and turns OFF at OFF time on STOP date. * One Record in three Steps(START/STOP date, ON/OFF time) Yearly pulse mode Output turns ON at ON time on START date and turns OFF at OFF time on STOP time for a specified pulse width repeatedly. * One record in three steps(START/STOP date, ON time, Pulse width) Program operation Weekly setting 1 of Program1 Weekly setting 2 of Program1 Yearly setting 1 of Program1 Output operation to : Operated by weekly setting 1 of Program 1. to : Operated by weekly setting 2 of Program 1. to : Operated by weekly setting 1 of Program 1. to : Operated by yearly setting 1 of Program 1. (During weekly program operation at 12:00 AM on START date, the weekly program operation stops, and it changes to yearly program operation mode. The yearly program operation stops at 12:00 AM on the next day of STOP date.) Display and change of next mode The day of next mode in Program is displayed on the day indicator, and the time of next mode is displayed on the lower row of screen. In ON/OFF operation mode, set ON time and OFF time to next mode. In Pulse operation mode, set Pulse ON time to next mode. K-90 This feature uses for setting seasonal weekly operation mode. To operate this mode, save starting month and date, ending month and date of each season which displays S1, S2, S3, S4 then set day and time of each season in weekly program setting. It is also able to operate only in summer and winter season. (S1: set summer season, S2: set winter season, S3/S4: do not set) In setting group 2-Level 2(SEN turns ON, OFF flashes.), select ON[ON] by or key and press SET key to save. When the season switching mode changed from OFF to ON or vice versa, previous set programs are deleted. ON[ON] mode Weekly program is switched automatically by season switching. * Period setting per season Press SET key in period setting per season mode of setting group 2.(SEN flashes, season with preset period turns ON and START and STOP turn ON.) Advance to the flashing position of season selection among S1, S2, S3, S4 by or key and press SET key. After set START month, date per season and press SET key. SET key is pressed after set STOP month, date per season, it is advanced to LEVEL1 of period setting per season. Add or adjust the period setting by SET key. It is disable to use when it is OFF [OFF]. If season terms are overlapped, these are prioritized in S4>S3>S2>S1 order. Weekly/Yearly Timer Daylight saving time To utilize daylight during the summer season, daylight saving time is adjusted forward one hour from standard time. In setting group 2-LEVEL 2(DST turns ON, AT or NOR flashes), select Auto [AT] or Normal [NOR] by or key and press SET key to set. Auto [AT] daylight saving time mode Current time will be faster as an hour when it is started and slower as an hour when it is finished. * Automatic daylight saving time period setting Automatic daylight saving time period setting LEVEL 1 of setting group 2. (Press SET key when DST flashes and START and STOP turn ON.) Set START date(month, date) of automatic daylight saving time mode and press SET key. Set START time(AM/PM, hour) of automatic daylight saving time mode and press SET key. But, the minute will be fixed as 00. Set STOP date(Month, date) of automatic daylight saving time mode and press SET key. Set STOP time(AM/PM, hour) of automatic daylight saving time mode and press SET key. But, the minute will be fixed as 00. Normal [NOR] daylight saving time mode Press +1h key over 3sec. in RUN mode, "+1h" turns ON and current time is faster as an hour and "+1h" turns ON out or vice versa, when press +1h key over 3sec. again. Current time setting (A) Photo electric sensor (Ex) Set the current time as 10, Mar, 2008, 5:10 PM. Advance to the current time setting mode SUN MON TUE WED THU FRI SAT MODE + SET keys are pressed over 3sec. in RUN mode, it is advanced to current time setting of setting group 2 and clock will be flashed and tAJ will be lighted in second display part, press SET key. (H) Temp. controller Press or key to select PM and move the flashing digit to position hour by key. (I) SSR/ Power controller (J) Counter (K) Timer Current time(hour, min.) setting SUN MON TUE WED THU FRI SAT (D) Proximity sensor Press or key to set (F) Rotary 08 (year 2008) and move encoder the flashing digit to position (G) month by key. Connector/ Press SET key after pressing Socket or key to set date 10. Current time(AM, PM) setting SUN MON TUE WED THU FRI SAT (C) Door/Area sensor (E) Pressure sensor Year, Month, Date setting SUN MON TUE WED THU FRI SAT (B) Fiber optic sensor Press or key to set 5 PM and move the flashing digit to position min. by key. Press or key to set 10min. and press SET key and it is returned to RUN mode when pressing MODE key over 3sec. It advances to to "Current time setting mode" in ON status and set current time as shown above to by SET key. Current time is set up to 31, Dec., 2099. Check current year/month/date in RUN mode When key is pressed over 3sec. in RUN mode, it advances to current year/month/date display. After display current year/month/date for 3sec, it returns to RUN mode displaying current display. (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller (P) Switching mode power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device (T) Software (U) Other K-91 LE365S-41 Program setting Setting group 1 Setting group 2 RUN mode Press MODE key for 3sec. RUN mode Press MODE key for 3sec. (Setting group 1) LEVEL1 Weekly program setting mode flashes) ( Press MODE + SET key for 3sec. Press MODE key for 3sec. LEVEL2 SET Weekly program setting MODE Yearly program setting mode , YEAR flashes) ( LEVEL2 SET Yearly program setting LEVEL2 SET Current time setting mode (Clock icon flashes) MODE LEVEL1 (Setting group 2) LEVEL1 LEVEL2 LEVEL1 Power failure return selection mode (RET flashes, ATor NOR turns ON) Current time setting SET Power restore selection SET Season switching selection MODE MODE LEVEL2 LEVEL1 Weekly program delete mode , CLR flashes) ( SET All weekly program delete MODE LEVEL2 LEVEL1 Yearly program delete mode , CLR, YEAR flashes) ( SET All yearly program delete LEVEL1 Season switching selection mode (SEN flashes, ON or OFF turns ON) 1 Weekly day change mode (cDY flashes) MODE LEVEL2 LEVEL1 Yearly holiday operation mode (hDY, YEAR flashes) Standard day, change day setting SET Yearly holiday operation mode setting MODE LEVEL2 LEVEL1 MODE LEVEL2 SET MODE SET Period setting for season mode (SEN flashes, period-set season turns ON and START or STOP turns ON) MODE LEVEL1 LEVEL2 LEVEL1 Daylight saving time selection mode (DST flashes, AT or NOR turns ON) 2 Period setting per season LEVEL2 SET Daylight saving time selection MODE LEVEL1 Automatic[AT] daylight saving time period setting mode (DST flashes, START or STOP turns ON) LEVEL2 SET Automatic daylight saving time period setting MODE When it is advanced to setting group 1 in RUN mode, output will be OFF. It is returned to previous setting group 1 when power of time switch is ON again in setting group 1. When MODE key is pressed in LEVEL2 of setting group 1, current setting will be canceled and it is returned to previous LEVEL1. When press SET key to program over max. number of steps for weekly program in Weekly program setting mode of setting group 1-LEVEL 1, number of remaining steps and STEP flash and it returns to LEVEL 1 status. When press SET key to program over max. number of steps for yearly program in Yearly program setting mode of setting group 1-LEVEL 1, number of remaining steps and STEP flash it returns to LEVEL 1 status. K-92 1: Season switching selection is OFF. 2: Automatic switching selection of Daylight Saving Time is Normal[NOR]. When it advances to setting group 2 in RUN mode, output (OUT1, OUT2) will be OFF. When power of time switch is ON again in setting group 2, it is returned to previous setting group 1. Front MODE key is pressed in LEVEL2 of setting group 2, it is returned to previous LEVEL1. When season switching selection is changed from OFF to ON or ON to OFF, previous set weekly program will be deleted. Weekly/Yearly Timer OFF time setting(AM, PM) Example of Weekly program setting Weekly ON/OFF mode (Ex) Output1(OUT1) is ON from Monday to Friday at 8:00 AM and OFF at 6:10 PM. SUN MON TUE WED THU FRI Select PM by or key and move the flashing to hour position by key. SAT 8:00 6:10 8:00 6:10 8:00 6:10 8:00 6:10 8:00 6:10 AM PM AM PM AM PM AM PM AM PM Advance to weekly program setting mode SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT OFF time setting(Hour, Min.) SUN MON TUE WED THU FRI SAT Move the flashing to minute position by key after set 6:00 by or key and set the minute as 10 by or key and press SET key. key is pressed over 3sec in RUN mode P flashes and press SET key. Complete to set SUN MON TUE WED THU FRI SAT (B) Fiber optic sensor (C) Door/Area sensor MODE Mode type setting (A) Photo electric sensor SUN MON TUE WED THU FRI SAT Press SET key in ON/OFF mode. (D) Proximity sensor (E) Pressure sensor (F) Rotary encoder (G) Connector/ Socket Press SET key to set additional program. (H) Temp. controller (I) SSR/ Power controller ON day setting SUN MON TUE WED THU FRI SAT Press key to move the indicator to Monday, it will be lighted when or key are pressed and move it to Tuesday by key. Press SET key after Tuesday, Wednesday, Thursday, Friday turn ON. ON time setting(AM, PM) SUN MON TUE WED THU FRI SAT key is pressed, move the flashing to hour position and select PM by or key when ON time is afternoon. ON time setting(Hour, Min.) SUN MON TUE WED THU FRI SAT Set 8:00 by or press SET key. key and OFF day setting SUN MON TUE WED THU FRI SAT Press SET key to check ON/ OFF day. Weekly Pulse mode (Ex) Output2(OUT2) is ON for 10sec at 8:00AM from Monday to Friday during S2 season in case, period of S1, S2, S3, S4 is set. SUN MON 8:00 AM TUE 8:00 AM WED 8:00 AM THU 8:00 AM FRI 8:00 AM 8:00 AM MODE key is pressed for 3sec. in RUN mode, P flashes and press SET key. (N) Display unit (P) Switching mode power supply (Q) Stepper motor& Driver&Controller or key when ON/ Press OFF flashes, pulse flashes and press SET key. (R) Graphic/ Logic panel (S) Field network device (T) Software Season selection SUN MON TUE WED THU FRI SAT (M) Tacho/ Speed/ Pulse meter (O) Sensor controller Mode type setting SUN MON TUE WED THU FRI SAT (K) Timer (L) Panel meter 8:00 AM ON for 10sec. Advance to weekly program setting mode SUN MON TUE WED THU FRI SAT SAT (J) Counter Press or key to select season S2 and press SET key. (U) Other K-93 LE365S-41 ON day setting SUN MON TUE WED THU FRI SAT Press key to move the indicator to Monday, it will be lighted when or key is pressed and move it to tuesday by key. Press SET key after light tuesday, wednesday, thursday and friday. Weekly Cycle mode (Ex) Output1(OUT1) is ON for 10min and OFF for 5min from Monday 6:00AM to Saturday 5:30PM. SUN MON TUE WED 6:00 AM Start Cycle mode THU FRI SAT ON for 10min. 5:30 PM ON time setting(AM, PM) SUN MON TUE WED THU FRI SAT Press key, move the flashing to hour position and select PM by or key when ON time is afternoon. OFF for 5min. Advance to weekly program setting mode SUN MON TUE WED THU FRI SAT In RUN mode, press MODE key for 3 sec. and P flashes. Press SET key. ON time setting(Hour, Min.) SUN MON TUE WED THU FRI SAT or Set 8:00 by press SET key. key and Mode type setting SUN MON TUE WED THU FRI SAT or key when ON/ Press OFF flashes, cycle flashes and press SET key. Pulse width setting SUN MON TUE WED THU FRI SAT or key to select Press pulse width as 10s (10sec.) and press SET key. to Refer to to of "Weekly ON/OFF mode" to set ON day, ON time, OFF day and OFF time. ON time width setting SUN MON TUE WED THU FRI SAT Complete to set SUN MON TUE WED THU FRI SAT Press SET key to set additional program. key to move the Press flashing to minute position and set as 10min. by or key and press SET key. OFF time width setting SUN MON TUE WED THU FRI SAT Press key to move the flashing to minute position and set as 5min. by or key and press SET key. Complete to set SUN MON TUE WED THU FRI SAT K-94 Press SET key to set additional program. Weekly/Yearly Timer Weekly day change When the specified day mode is required to install in other day, it is started from the set day and returned to previous program setting automatically when it is finished. Weekly day change cancellation Change current year, month, date in current time setting mode Change standard day Delete all program in program Season switching Setting example Output is ON in saturday at 9:00AM and OFF at 12:00PM and it is ON 8:30AM and OFF at 6:00PM from monday to friday and the mode of monday and Tuesday is operated temporarily as saturday(standard) program. Yearly holiday mode It operates to off the output without program adjustment during previously set yearly holiday period available from present year to 31, Dec. of the next year. Designate the start date of yearly holiday and year of end date as every year [--] to repeat the holiday mode for specified in every year. Setting example Set every year 5, May to off the output. Advance to yearly holiday mode SUN MON TUE WED THU FRI SAT Advance to weekly day change mode SUN MON TUE WED THU FRI SAT Press MODE key over 3sec. to move to the setting group1 in RUN mode and press it repeatedly until cDY flashes in second display part and press SET key. Press MODE key over 3sec. to move to the setting group1 in RUN mode and press it repeatedly until hDY flashes in second display part and press SET key. Press SET key after check yearly holiday No. Press key to move the indicator to saturday and press SET key. after select saturday as standard day(Sat turns ON) by or key. Press key to move the indicator to monday and select monday to change (Monday turns ON) by or key and repeat the procedure to select tuesday to change (Tue turns ON) and press SET key to complete. (D) Proximity sensor (E) Pressure sensor (F) Rotary encoder (I) SSR/ Power controller (J) Counter Start date of yearly holiday setting SUN MON TUE WED THU FRI SAT Change day selection SUN MON TUE WED THU FRI SAT (C) Door/Area sensor (H) Temp. controller Standard day selection SUN MON TUE WED THU FRI SAT (B) Fiber optic sensor (G) Connector/ Socket Yearly holiday No. display SUN MON TUE WED THU FRI SAT (A) Photo electric sensor key until month[--] Press position flashes and set May by or key and press key until date position flashes. Press SET key after set 5th by or key. End date of yearly holiday setting SUN MON TUE WED THU FRI SAT The flashing is moved to month[--] position directly and press or key to set May and press key until date position flashes. Press SET key after set 5th by or key. Complete to yearly holiday SUN MON TUE WED THU FRI SAT Press MODE key to finish the additional yearly holiday setting and press SET key to set . It is able to set yearly holiday up to 12 times. (K) Timer (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller (P) Switching mode power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device (T) Software (U) Other K-95 LE365S-41 Yearly program setting Yearly ON/OFF mode (Ex) Output(OUT) is ON from every 5, Apr to 7, Apr at 9:00AM and OFF 5:10PM. Advance to Program1(P1) yearly program setting mode SUN MON TUE WED THU FRI SAT Press MODE key for 3 sec. in RUN mode, P flashes and press MODE key once, then, P and YEAR flash and press SET key to set. OFF time setting(Hour, Min.) SUN MON TUE WED THU FRI SAT Move the flashing to minute position after set 5:00 by or key and set the minute as 10 and press SET key. Complete to set SUN MON TUE WED THU FRI SAT Press SET key to set additional program. Mode type setting SUN MON TUE WED THU FRI SAT Press SET key when ON/OFF flashes. Yearly pulse mode (Ex) Output(OUT) is ON from 2, Oct., 2008 to 4,Oct, 2008 at 10:00AM and OFF after 5sec. (Present is 2007.) 2, Oct Start date setting SUN MON TUE WED THU FRI SAT Press key until month position flashes and set Apr by or key and press key until date position flashes. Press SET key after set 5th by or key. 8:00 AM 4, Oct 3, Oct 8:00 AM 8:00 AM The flashing is moved to month position directly and press or key to set April and press key until date position flashes. Press SET key after set 7th by or key. 10:00AM Advance to yearly program setting mode SUN MON TUE WED THU FRI SAT End date setting SUN MON TUE WED THU FRI SAT ON for 5sec. MODE key is pressed for 3sec in RUN mode, P flashes and press MODE key again, P flashes and press SET key. Mode type setting SUN MON TUE WED THU FRI SAT or key is pressed when ON/OFF flashes to set pulse mode and press SET key. ON time setting(AM, PM) SUN MON TUE WED THU FRI SAT key is pressed, move the flashing to hour position and select PM by or key when ON time is afternoon. Start date setting SUN MON TUE WED THU FRI SAT ON time setting(Hour, Min.) SUN MON TUE WED THU FRI SAT Press or key to set 9 and press SET key after check 00min. End date setting SUN MON TUE WED THU FRI SAT OFF time setting(AM, PM) SUN MON TUE WED THU FRI SAT K-96 Select PM by or key and move the flashing to hour position by key. Press or key twice to set 08(year 2008) and move to month position by key. Set Oct. by or key and move to date position by key and press SET key after set 2nd by or key. The flashing is moved to month position directly by key and set 4th by or key after move it to date position by key, then press SET key. Weekly/Yearly Timer ON time setting(AM, PM) SUN MON TUE WED THU FRI SAT Yearly program check, modify and delete key is pressed, move the flashing to hour position and select PM by or key when ON time is afternoon. Press or key twice to set 10 and press SET key after check 00min. Press SET key for 3sec. Yearly program record No.1[r01] setting modify and delete CHECK Yearly program record No.2[r02] setting check Press SET key for 3sec. Yearly program record No.2[r02] setting modify and delete Press or key 4 times to select pulse width as 5s and press SET key. Yearly program record No.n[rN] setting check Press SET key for 3sec. Yearly program record No.n[rN] setting modify and delete CHECK Press SET key to set additional program. It is able to set year of start/end date in yearly program setting up to 2 years later from the present year. Program check, modify and delete Weekly program check, modify and delete RUN mode Press MODE key for 3sec. Press CHECK key for 1sec. Weekly program record No.1[r01] setting check (E) Pressure sensor (F) Rotary encoder Press SET key for 1sec. Weekly program record No.1[r01] setting modify and delete Press SET key for 3sec. (G) Connector/ Socket (H) Temp. controller (J) Counter If any key is untouched for 60sec., it is returned to RUN mode in weekly or yearly program check. In weekly or yearly program check, it controls output according to program setting and output is OFF in modify or delete mode. When MODE key is pressed in weekly or yearly program record modify, delete stand by or delete mode, current work is cancelled and it is returned to check mode. Weekly or yearly program record modify and delete (1) Program record modify When press SET key over 3sec. in program check, EDT flashes in second display part, press SET key. It returns to check mode when finish the modify same as the above procedure. (2) Program record delete When press SET key over 3sec. in program check, EDT flashes in second display part, press or key until CLR flashes in second display part and press SET key. Press CLR key over 3sec. when SET turns ON in second display part, it returns to program check. (K) Timer (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller (P) Switching mode power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel CHECK Weekly program record No.2[r02] setting check (D) Proximity sensor (I) SSR/ Power controller YEAR turns ON when check, modify or delete yearly program. Complete to set SUN MON TUE WED THU FRI SAT (C) Door/Area sensor CHECK Pulse width setting SUN MON TUE WED THU FRI SAT (B) Fiber optic sensor Press CHECK key for 1sec. Yearly program record No.1[r01] setting check ON time setting(Hour, Min.) SUN MON TUE WED THU FRI SAT RUN mode Press MODE key for 3sec. (A) Photo electric sensor (S) Field network device Weekly program record No.2[r02] setting modify and delete (T) Software CHECK Weekly program record No.n[rN] setting check Press SET key for 3sec. (U) Other Weekly program record No.n[rN] setting modify and delete CHECK K-97