K-87
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
LE365S-41
CONTACT OUT:
250VAC 15A
RESISTIVE LOAD
SOURCE:
100-240VAC
50/60
1 2 3 4
Ordering information
Features
Specications
W48×H48mm, Weekly/Yearly timer
● Easy to check and change the program setting
● Customizable weekly or yearly unit time setting and
control by user
● Includes daylight saving time function
● 1 independent control output.(Relay)
● Flush and surface, DIN rail mounting are in one unit.
Connections
Model LE365S-41
Power supply 100-240VAC 50/60
Allowable voltage range 90 to 110% of rated voltage
Power consumption 2.4VA
Timing program 48 steps for weekly, 24 steps for yearly
Operation mode ON/OFF mode, cycle mode, pulse mode
Mounting Panel ush, surface, DIN rail
Time deviation ±15sec/month(25) (±4sec/week)
Temperature error ±0.01% ±0.05sec.
Memory protection Over 5 years(at 25)
Control
Output
Contact type SPST(Single Pole Single Throw)
Contact capacity 250VAC 15A resistive load
Output number Independent 1 output(1a)
Relay
life cycle
Mechanical Min. 5,000,000 operations(Switching capacity 30 times/minute)
Electrical 50,000 operations<Switching capacity 20 times/1 minute, at 250VAC 15A(resistive load)>
Insulation resistance Min. 100MΩ(at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1minute
Noise strength ±2kV the square wave noise(pulse width : 1) by the noise simulator
Environ
-ment
Ambient temperature -10 to 55, storage: -25 to 65
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Unit weight Approx. 110g
Item
Size
Power supply
Output
LE365 S 4 1
1 1 Relay outputs
4 100-240VAC
S DIN W48×H48mm
LE365 Weekly/Yearly timer
Environment resistance is rated at no freezing or condensation.
Please read “Caution for your safety” in operation
manual before using.
K-88
LE365S-41
6
16
42.7
66 3
DIN rail
59
61
61.5 4
35
61
43
Panel
2-M3 TAP
Fix the Weekly/Yearly
timer on the panel with
M3 tapping screws.
6.8 60
44.8
48
48
Unscrew 1 bolts
from terminal block
Remove terminals from the body after unscrewing terminals screws, and then assemble terminals to the body after rotating
terminals as shown below.
(front panel mounting)
(surface mounting type) (DIN rail type)
Detach terminal
block from case
and rotate it
180˚degree.
Detach the terminal
block after unscrew
terminal screws with
tools.
To raise panel holder, tools
must be used.
Screw terminals block
with a xing bolt.
Assemble case
and terminal
block
Dimensions & Mounting
How to switch from the ush mounting to surface or DIN rail mounting type
(unit: mm)
1) Front panel mounting
2) Surface mounting
3) DIN rail mounting
● Panel hole cut-out
Min. 55
Min. 65
● Panel cut-out
45+0.6
0
45+0.6
0
K-89
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
Parts description
Functions
1
10
2
11
3
12
413
514
615
7
16
8
17
9
18
19 20 21 22 23
ON Time OFF Time
1. Day indicator
2. Day display
● Light : Day is selected.
● Light-out : Day is not selected.
3. Current time setting mode indicator
4. DST display(Daylight saving time)
5. AM/PM display(Main display)
6. Season display
7. Program display
8. Display ON time/day, OFF time/day, ON time width,
OFF time width
9. AM/PM display(Sub-display)
10. YEAR display
: It turns ON when set, check, modify, delete yearly
program, set yearly holidays and operate yearly
program.
11. Yearly START/STOP day display
12. Main display
13. Remaining step display
14. Operation mode display
15. Output mode display
16. Year, month, date display
17. Unit of pulse width display
18. Sub display
19. CHECK key
20. MODE key
21. Operation key
: Press +1h key over 3sec. in RUN mode, DST mode is
set and released.
22. SET key
23. Output selection switch
AUTO : Control output according to the set program.
● ON : Output is ON.(Operation)
● OFF : Output is OFF.(Block)
Definitions
● Record: A part of program that controls output operation.
● Step: Basic component of Record.
Operation modes
● If the operation mode of Program1 (program2) is set on
pulse mode initially, the pulse mode is xed for additional
programs. If the operation mode of Program1 (program2)
is set on ON/OFF or cycle mode initially, pulse mode
cannot be used for additional pulse programs.
● If the weekly operation mode is set on ON/OFF or cycle
mode, the yearly operation mode is xed on ON/OFF
mode.
If the yearly operation mode is set on ON/OFF, the
weekly operation mode is xed on ON/OFF or cycle
mode.
● If the weekly operation mode is set on pulse mode, the
yearly operation mode is xed on pulse mode. If the
yearly operation mode is set on pulse mode, the weekly
operation mode is xed on pulse.
●Weekly ON/OFF mode
Output operation by ON/OFF set time.
• Min. time setting unit : 1 min.
• It is able to set ON/OFF day separately.
• One record in two steps
(ON day/ON time, OFF day/OFF time)
●Weekly Cycle operation
It outputs ON the set ON time width which is from Cycle
operation ON time to Cycle operation OFF time, and it
outputs OFF the set OFF time width.
K-90
LE365S-41
ON time
Pulse width
(1 to 59sec., 1 to 60min.)
Weekly setting 1 of Program1
Weekly setting 2 of Program1
Yearly setting 1 of Program1
Output operation
ON Time ON width OFF Time
OFF width
• Set range for ON/OFF time width
: 1min. to 12 hour 59min.
• One record in 3 steps(ON day/ON time, OFF day/OFF
time, ON time width/OFF time width)
● Weekly pulse mode
Output turns ON at ON time for a specied pulse width.
(Pulse width : 1 to 59sec., 1 to 60min.)
• One record in two steps(ON day/ON time, pulse width)
● Yearly ON/OFF mode
Output turns ON at ON time on START date and turns OFF
at OFF time on STOP date.
• One Record in three Steps(START/STOP date, ON/OFF
time)
● Yearly pulse mode
Output turns ON at ON time on START date and turns
OFF at OFF time on STOP time for a specied pulse width
repeatedly.
• One record in three steps(START/STOP date, ON time,
Pulse width)
Program operation
to : Operated by weekly setting 1 of Program 1.
to : Operated by weekly setting 2 of Program 1.
to : Operated by weekly setting 1 of Program 1.
to : Operated by yearly setting 1 of Program 1.
(During weekly program operation at 12:00 AM on
START date, the weekly program operation stops, and it
changes to yearly program operation mode. The yearly
program operation stops at 12:00 AM on the next day of
STOP date.)
Display and change of next mode
● The day of next mode in Program is displayed on the day
indicator, and the time of next mode is displayed on the
lower row of screen.
● In ON/OFF operation mode, set ON time and OFF time
to next mode. In Pulse operation mode, set Pulse ON
time to next mode.
Power restore mode
In setting group 2 - LEVEL2 (RET turns ON, AT or NOR
ashes), select Auto[AT] or Normal [NOR] by or key
and press SET key to set.
Auto [AT] power restore mode
Output operates according to program when power turns
ON again after power failure.
●Normal[NOR] power restore mode
When power turns ON again after power failure, output
is kept OFF and rIN ashes on the lower row of screen
and power restore input (press SET key over 3 sec.
in RUN mode) is applied, rIN turns OFF and output
operates according to program.
Season switching mode
This feature uses for setting seasonal weekly operation
mode. To operate this mode, save starting month and date,
ending month and date of each season which displays S1,
S2, S3, S4 then set day and time of each season in weekly
program setting. It is also able to operate only in summer
and winter season. (S1: set summer season, S2: set winter
season, S3/S4: do not set)
In setting group 2-Level 2(SEN turns ON, OFF ashes.),
select ON[ON] by or key and press SET key to save.
When the season switching mode changed from OFF
to ON or vice versa, previous set programs are deleted.
● ON[ON] mode
Weekly program is switched automatically by season
switching.
• Period setting per season
Press SET key in period setting per season mode of
setting group 2.(SEN ashes, season with preset period
turns ON and START and STOP turn ON.)
Advance to the ashing position of season selection
among S1, S2, S3, S4 by or key and press SET
key.
After set START month, date per season and press SET
key.
SET key is pressed after set STOP month, date per
season, it is advanced to LEVEL1 of period setting per
season. Add or adjust the period setting by SET key.
● It is disable to use when it is OFF [OFF].
● If season terms are overlapped, these are prioritized in
S4>S3>S2>S1 order.
K-91
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
Daylight saving time
To utilize daylight during the summer season, daylight
saving time is adjusted forward one hour from standard
time.
In setting group 2-LEVEL 2(DST turns ON, AT or NOR
ashes), select Auto [AT] or Normal [NOR] by or key
and press SET key to set.
Auto [AT] daylight saving time mode
Current time will be faster as an hour when it is started and
slower as an hour when it is nished.
Automatic daylight saving time period setting
Automatic daylight saving time period setting LEVEL 1
of setting group 2.
(Press SET key when DST ashes and START and
STOP turn ON.)
Set START date(month, date) of automatic daylight
saving time mode and press SET key.
Set START time(AM/PM, hour) of automatic daylight
saving time mode and press SET key. But, the minute
will be xed as 00.
Set STOP date(Month, date) of automatic daylight
saving time mode and press SET key.
Set STOP time(AM/PM, hour) of automatic daylight
saving time mode and press SET key. But, the minute
will be xed as 00.
● Normal [NOR] daylight saving time mode
Press +1h key over 3sec. in RUN mode, "+1h" turns ON
and current time is faster as an hour and "+1h" turns ON
out or vice versa, when press +1h key over 3sec. again.
Current time setting
(Ex) Set the current time as 10, Mar, 2008, 5:10 PM.
● It advances to to "Current time setting mode" in ON
status and set current time as shown above to by
SET key.
● Current time is set up to 31, Dec., 2099.
● Check current year/month/date in RUN mode When
key is pressed over 3sec. in RUN mode, it advances to
current year/month/date display. After display current
year/month/date for 3sec, it returns to RUN mode
displaying current display.
Advance to the current time setting mode
MODE + SET keys are pressed
over 3sec. in RUN mode, it
is advanced to current time
setting of setting group 2
and clock will be ashed and
tAJ will be lighted in second
display part, press SET key.
SUN MON TUE WED THU FRI SAT
Year, Month, Date setting
Press or key to set
08 (year 2008) and move
the ashing digit to position
month by key.
Press SET key after pressing
or key to set date 10.
SUN MON TUE WED THU FRI SAT
Current time(AM, PM) setting
Press or key to select
PM and move the ashing
digit to position hour by
key.
SUN MON TUE WED THU FRI SAT
Current time(hour, min.) setting
Press or key to set 5
PM and move the ashing
digit to position min. by
key. Press or key to set
10min. and press SET key
and it is returned to RUN
mode when pressing MODE
key over 3sec.
SUN MON TUE WED THU FRI SAT
K-92
LE365S-41
RUN mode RUN mode
(Setting group 1)
1
2
(Setting group 2)
Weekly program setting mode
( ashes)
Weekly program
setting
Current time setting mode
(Clock icon ashes)
Power failure return selection mode
(RET ashes, ATor NOR turns ON)
Season switching selection mode
(SEN ashes, ON or OFF turns ON)
Period setting for season mode
(SEN ashes, period-set season turns ON and
START or STOP turns ON)
Daylight saving time selection mode
(DST ashes, AT or NOR turns ON)
Automatic[AT] daylight saving
time period setting mode
(DST ashes, START or STOP turns ON)
Current time
setting
Power restore
selection
Season switching
selection
Period setting
per season
Daylight saving
time selection
Automatic
daylight
saving time
period setting
Yearly program setting mode
(, YEAR ashes)
Weekly program delete mode
(, CLR ashes)
Yearly program delete mode
(, CLR, YEAR ashes)
Weekly day change mode
(cDY ashes)
Yearly holiday operation mode
(hDY, YEAR ashes)
Yearly program
setting
All weekly
program delete
All yearly
program delete
Standard day,
change day
setting
Yearly holiday
operation mode
setting
Program setting
LEVEL1 LEVEL1
LEVEL1
LEVEL1
LEVEL1
LEVEL1
LEVEL1
LEVEL2 LEVEL2
LEVEL2
LEVEL2
LEVEL2
LEVEL2
LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
LEVEL1 LEVEL2
SET SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
MODE MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
Setting group 1 Setting group 2
● When it is advanced to setting group 1 in RUN mode,
output will be OFF.
● It is returned to previous setting group 1 when power of
time switch is ON again in setting group 1.
● When MODE key is pressed in LEVEL2 of setting group
1, current setting will be canceled and it is returned to
previous LEVEL1.
● When press SET key to program over max. number
of steps for weekly program in Weekly program setting
mode of setting group 1-LEVEL 1, number of remaining
steps and STEP ash and it returns to LEVEL 1 status.
● When press SET key to program over max. number of
steps for yearly program in Yearly program setting mode
of setting group 1-LEVEL 1, number of remaining steps
and STEP ash it returns to LEVEL 1 status.
1: Season switching selection is OFF.
2: Automatic switching selection of Daylight Saving Time
is Normal[NOR].
● When it advances to setting group 2 in RUN mode,
output (OUT1, OUT2) will be OFF.
● When power of time switch is ON again in setting group 2,
it is returned to previous setting group 1.
● Front MODE key is pressed in LEVEL2 of setting group 2,
it is returned to previous LEVEL1.
● When season switching selection is changed from OFF
to ON or ON to OFF, previous set weekly program will be
deleted.
Press
MODE
key
for 3sec.
Press
MODE
key
for 3sec.
Press
MODE
+
SET
key for 3sec.
Press
MODE
key
for 3sec.
K-93
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
SUN MON TUE WED THU FRI SAT
8:00
AM
8:00
AM
8:00
AM
8:00
AM
8:00
AM
8:00
AM
ON for 10sec.
8:00 AM
Example of Weekly program setting
Weekly ON/OFF mode
(Ex) Output1(OUT1) is ON from Monday to Friday at 8:00
AM and OFF at 6:10 PM.
● Weekly Pulse mode
(Ex) Output2(OUT2) is ON for 10sec at 8:00AM from Mon-
day to Friday during S2 season in case, period of S1, S2,
S3, S4 is set.
8:00
AM
8:00
AM
8:00
AM
8:00
AM
8:00
AM
6:10
PM
6:10
PM
6:10
PM
6:10
PM
6:10
PM
SUN MON TUE WED THU FRI SAT
Advance to weekly program setting mode
MODE key is pressed over
3sec in RUN mode P ashes
and press SET key.
SUN MON TUE WED THU FRI SAT
Mode type setting
Press SET key in ON/OFF
mode.
SUN MON TUE WED THU FRI SAT
ON time setting(AM, PM)
key is pressed, move the
ashing to hour position and
select PM by or key
when ON time is afternoon.
ON day setting
Press key to move the
indicator to Monday, it will
be lighted when or key
are pressed and move it to
Tuesday by key.
Press SET key after Tuesday,
Wednesday, Thursday,
Friday turn ON.
SUN MON TUE WED THU FRI SAT
SUN MON TUE WED THU FRI SAT
ON time setting(Hour, Min.)
Set 8:00 by or key and
press SET key.
SUN MON TUE WED THU FRI SAT
OFF day setting
Press SET key to check ON/
OFF day.
SUN MON TUE WED THU FRI SAT
OFF time setting(AM, PM)
Select PM by or key
and move the ashing to hour
position by key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set
additional program.
SUN MON TUE WED THU FRI SAT
Advance to weekly program setting mode
MODE key is pressed for
3sec. in RUN mode, P
ashes and press SET key.
SUN MON TUE WED THU FRI SAT
Mode type setting
Press or key when ON/
OFF ashes, pulse ashes
and press SET key.
SUN MON TUE WED THU FRI SAT
Season selection
Press or key to select
season S2 and press SET
key.
SUN MON TUE WED THU FRI SAT
OFF time setting(Hour, Min.)
SUN MON TUE WED THU FRI SAT
Move the ashing to minute
position by key after set
6:00 by or key and set
the minute as 10 by or
key and press SET key.
K-94
LE365S-41
ON day setting
Press key to move the
indicator to Monday, it will be
lighted when or key is
pressed and move it to tuesday
by key. Press
SET
key after
light tuesday, wednesday,
thursday and friday.
SUN MON TUE WED THU FRI SAT
ON time setting(AM, PM)
Press key, move the
ashing to hour position and
select PM by or key
when ON time is afternoon.
SUN MON TUE WED THU FRI SAT
ON time setting(Hour, Min.)
Set 8:00 by or key and
press SET key.
SUN MON TUE WED THU FRI SAT
Pulse width setting
Press or key to select
pulse width as 10s (10sec.)
and press SET key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set
additional program.
SUN MON TUE WED THU FRI SAT
③ to ⑧
Refer to to of "Weekly ON/OFF mode" to set ON
day, ON time, OFF day and OFF time.
Mode type setting
Press or key when ON/
OFF ashes, cycle ashes
and press SET key.
SUN MON TUE WED THU FRI SAT
ON time width setting
Press key to move the
ashing to minute position
and set as 10min. by or
key and press SET key.
SUN MON TUE WED THU FRI SAT
OFF time width setting
Press key to move the
ashing to minute position
and set as 5min. by
or
key and
press SET key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press
SET
key to set additional
program.
SUN MON TUE WED THU FRI SAT
6:00 AM
Start Cycle mode
5:30
PM
ON for 10min.
OFF for 5min.
● Weekly Cycle mode
(Ex) Output1(OUT1) is ON for 10min and OFF for 5min
from Monday 6:00AM to Saturday 5:30PM.
SUN MON TUE WED THU FRI SAT
Advance to weekly program setting mode
SUN MON TUE WED THU FRI SAT
In RUN mode, press MODE
key for 3 sec. and P
ashes. Press SET key.
K-95
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
Complete to yearly holiday
Press MODE key to nish
the additional yearly holiday
setting and press SET key to
set .
It is able to set yearly
holiday up to 12 times.
SUN MON TUE WED THU FRI SAT
Yearly holiday mode
It operates to off the output without program adjustment
during previously set yearly holiday period available from
present year to 31, Dec. of the next year.
Designate the start date of yearly holiday and year of end
date as every year [--] to repeat the holiday mode for
specied in every year.
● Setting example
Set every year 5, May to off the output.
Advance to weekly day change mode
Press MODE key over 3sec.
to move to the setting group1
in RUN mode and press it
repeatedly until cDY ashes
in second display part and
press SET key.
SUN MON TUE WED THU FRI SAT
Standard day selection
Press key to move the
indicator to saturday and
press SET key. after select
saturday as standard day(Sat
turns ON) by or key.
SUN MON TUE WED THU FRI SAT
Change day selection
Press key to move the
indicator to monday and
select monday to change
(Monday turns ON) by
or key and repeat the
procedure to select tuesday
to change (Tue turns ON)
and press SET key to
complete.
SUN MON TUE WED THU FRI SAT
Advance to yearly holiday mode
Press MODE key over 3sec.
to move to the setting group1
in RUN mode and press it
repeatedly until hDY ashes
in second display part and
press SET key.
SUN MON TUE WED THU FRI SAT
Yearly holiday No. display
Press SET key after check
yearly holiday No.
SUN MON TUE WED THU FRI SAT
Start date of yearly holiday setting
Press key until month[--]
position ashes and set May
by or key and press
key until date position
ashes. Press SET key after
set 5th by or key.
SUN MON TUE WED THU FRI SAT
End date of yearly holiday setting
The ashing is moved to
month[--] position directly
and press or key to set
May and press key until
date position ashes.
Press SET key after set 5th
by or key.
SUN MON TUE WED THU FRI SAT
Weekly day change
When the specied day mode is required to install in other
day, it is started from the set day and returned to previous
program setting automatically when it is nished.
● Weekly day change cancellation
Change current year, month, date in current time setting
mode
Change standard day
Delete all program in program
Season switching
Setting example
Output is ON in saturday at 9:00AM and OFF at 12:00PM
and it is ON 8:30AM and OFF at 6:00PM from monday to
friday and the mode of monday and Tuesday is operated
temporarily as saturday(standard) program.
K-96
LE365S-41
2, Oct 3, Oct 4, Oct
8:00
AM
8:00
AM
8:00
AM
ON for 5sec.
10:00AM
Yearly pulse mode
(Ex) Output(OUT) is ON from 2, Oct., 2008 to 4,Oct, 2008
at 10:00AM and OFF after 5sec. (Present is 2007.)
End date setting
The ashing is moved to
month position directly and
press or key to set April
and press key until date
position ashes. Press SET
key after set 7th by or
key.
SUN MON TUE WED THU FRI SAT
ON time setting(AM, PM)
key is pressed, move the
ashing to hour position and
select PM by or key
when ON time is afternoon.
SUN MON TUE WED THU FRI SAT
ON time setting(Hour, Min.)
Press or key to set
9 and press SET key after
check 00min.
SUN MON TUE WED THU FRI SAT
OFF time setting(AM, PM)
Select PM by or key
and move the ashing to
hour position by key.
SUN MON TUE WED THU FRI SAT
Advance to yearly program setting mode
MODE key is pressed for 3sec
in RUN mode, P ashes and
press MODE key again, P
ashes and press SET key.
SUN MON TUE WED THU FRI SAT
Mode type setting
or key is pressed when
ON/OFF ashes to set pulse
mode and press SET key.
SUN MON TUE WED THU FRI SAT
Start date setting
Press or key twice to
set 08(year 2008) and move
to month position by key.
Set Oct. by or key and
move to date position by
key and press SET key after
set 2nd by or key.
SUN MON TUE WED THU FRI SAT
End date setting
The ashing is moved to
month position directly by
key and set 4th by or
key after move it to date
position by key, then press
SET key.
SUN MON TUE WED THU FRI SAT
Yearly program setting
● Yearly ON/OFF mode
(Ex) Output(OUT) is ON from every 5, Apr to 7, Apr at
9:00AM and OFF 5:10PM.
Advance to Program1(P1) yearly program setting mode
Press MODE key for 3 sec.
in
RUN mode,
P
ashes
and
press MODE key once, then,
P and YEAR ash and press
SET key to set.
SUN MON TUE WED THU FRI SAT
Mode type setting
Press
SET
key when ON/OFF
ashes.
SUN MON TUE WED THU FRI SAT
Start date setting
Press key until month
position ashes and set Apr
by or key and press
key until date position
ashes. Press SET key after
set 5th by or key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set
additional program.
SUN MON TUE WED THU FRI SAT
OFF time setting(Hour, Min.)
SUN MON TUE WED THU FRI SAT
Move the ashing to minute
position after set 5:00 by
or key and set the minute
as 10 and press SET key.
K-97
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
mode power
supply
(Q)
Stepper
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Weekly/Yearly Timer
RUN mode
Weekly program
record No.1[r01]
setting check
Weekly program
record No.1[r01] setting
modify and delete
Weekly program
record No.2[r02] setting
modify and delete
Weekly program
record No.n[rN] setting
modify and delete
Weekly program
record No.2[r02]
setting check
Weekly program
record No.n[rN]
setting check
Program check, modify and delete
CHECK
CHECK
CHECK
Weekly program check, modify and delete
Press CHECK
key for 1sec.
Press
MODE
key
for 3sec.
Press SET
key for 1sec.
Press SET
key for 3sec.
Press SET
key for 3sec.
RUN mode
Yearly program
record No.1[r01]
setting check
Yearly program
record No.1[r01] setting
modify and delete
Yearly program
record No.2[r02] setting
modify and delete
Yearly program
record No.n[rN] setting
modify and delete
Yearly program
record No.2[r02]
setting check
Yearly program
record No.n[rN]
setting check
CHECK
CHECK
CHECK
Yearly program check, modify and delete
YEAR turns ON when check, modify or delete yearly
program.
● If any key is untouched for 60sec., it is returned to RUN
mode in weekly or yearly program check.
● In weekly or yearly program check, it controls output
according to program setting and output is OFF in modify
or delete mode.
● When MODE key is pressed in weekly or yearly program
record modify, delete stand by or delete mode, current
work is cancelled and it is returned to check mode.
● Weekly or yearly program record modify and delete
(1) Program record modify
When press SET key over 3sec. in program check, EDT
ashes in second display part, press SET key.
It returns to check mode when nish the modify same
as the above procedure.
(2) Program record delete
When press SET key over 3sec. in program check, EDT
ashes in second display part, press or key until
CLR ashes in second display part and press SET key.
Press CLR key over 3sec. when SET turns ON in
second display part, it returns to program check.
Press SET
key for 3sec.
Press SET
key for 3sec.
Press SET
key for 3sec.
Press CHECK
key for 1sec.
Press
MODE
key
for 3sec.
It is able to set year of start/end date in yearly program
setting up to 2 years later from the present year.
ON time setting(AM, PM)
key is pressed, move the
ashing to hour position and
select PM by or key
when ON time is afternoon.
SUN MON TUE WED THU FRI SAT
ON time setting(Hour, Min.)
Press or key twice to
set 10 and press SET key
after check 00min.
SUN MON TUE WED THU FRI SAT
Pulse width setting
Press or key 4 times to
select pulse width as 5s and
press SET key.
SUN MON TUE WED THU FRI SAT
Complete to set
Press SET key to set
additional program.
SUN MON TUE WED THU FRI SAT