Timers GT5P Series Circuit Breakers Terminal Blocks Timers Relays & Sockets Display Lights Switches & Pilot Lights GT5P Series -- ON Delay Timers Key features of the GT5P series include: * * * * * * * SPDT, 5A contacts 8-pin, octal base 9 time ranges Repeat error 0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same sockets and hold down clips as IDEC's RR2P 8-pin relays UL Recognized File No. E55996 CSA Certified File No. LR66809 Specifications Rated Operating Voltage 100 to 120V AC (50/60Hz) 200 to 240V AC (50/60Hz) 24V AC/DC 12V DC Voltage Tolerance AC type: 15% DC type: 10% (ripple 10% maximum) Resistive load 120V AC/24V DC, 5A 240V AC, 3A Inductive load 240V AC, 0.8A 120V AC, 1.4A 24V DC, 1.7A Contact Rating Allowable Contact Power (resistive load) 960VA AC 120W DC Contact Form SPDT Voltage 250V AC, 150V DC Repeat Error 0.2% 10msec Voltage Error 0.5% 10msec Temperature Error 3% maximum (over -10 to 50C, reference temperature 20C) Setting Error 10% maximum Reset Time When turning power off after time up: 0.1 sec maximum When turning power off before time up: 1 sec maximum Insulation Resistance 100M minimum Dielectric Strength 2000V AC, 1 minute (except between contacts of the same pole) Vibration Resistance 100N (approximate 10G) Shock Resistance Operating extremes: 100N (approximate 10G) Damage limits: 500N (approximate 50G) Power Consumption 100V AC type: 1.5VA (at 50Hz) 200V AC type: 1.6VA (at 50Hz) 24V DC type: 0.9W Electrical Life 100,000 operations minimum (at rated load) Mechanical Life 20,000,000 operations minimum Operating Temperature -10 to +50C Operating Humidity 45 to 85% RH 1. Inductive load (reference), cos o =0.3 to 0.4 or L/R=15msec. 2. Minimum applicable load: 5VDC/10mA (reference). 848 www.idec.com Timers GT5P Series Part Numbering List Contact Output Rated Voltage 100 to 120V AC SPDT 24V DC/120V AC, 5A 240V AC, 3A 24V AC/DC -- 3S GT5P-N3SA100 6S -- 10S GT5P-N10SA100 30S GT5P-N30SA100 60S GT5P-N60SA100 3M GT5P-N3MA100 6M GT5P-N6MA100 10M GT5P-N10MA100 1S GT5P-N1SA200 3S -- 6S GT5P-N6SA200 10S GT5P-N10SA200 30S GT5P-N30SA200 60S GT5P-N60SA200 3M GT5P-N3MA200 6M GT5P-N6MA200 10M GT5P-N10MA200 1S GT5P-N1SAD24 3S -- 6S GT5P-N6SAD24 10S GT5P-N10SAD24 30S -- 60S GT5P-N60SAD24 3M -- 6M GT5P-N6MAD24 10M GT5P-N10MAD24 1S -- 3S -- -- 10S GT5P-N10SD12 30S GT5P-N30SD12 60S GT5P-N60SD12 3M -- 6M -- 10M GT5P-N10MD12 Terminal Blocks 6S Timers 12V DC 1S Relays & Sockets ON-Delay Complete Part No. Display Lights 200 to 240V AC Time Range Switches & Pilot Lights Mode of Operation For sockets and accessories, see page 851. Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 849 Timers GT5P Series Switches & Pilot Lights Timing Diagram/Schematic/Electrical Life Curves SPDT m n l (-) k Operation Mode o p (+) j q POWER Do not apply voltage to terminals 1, 3, and 4. Display Lights Item Set Time Terminal Number Power ON-Delay Operation 2 - 7 (8p) Delayed Contact 5 - 8 (8p) (NC) 6 - 8 (8p) (NO) POWER Indicator Electrical Life Curves Life (x 10,000 operations) Relays & Sockets OUT 100 70 50 30 20 24V DC Resistive Load 120V AC Resistive Load 10 7 5 240V AC Resistive Load 24V DC Inductive Load 3 2 120V AC Inductive Load 240V AC Inductive Load 1 1 2 3 4 Load Current (A) Circuit Breakers Terminal Blocks Timers 0 850 www.idec.com 5 Timers GT5P Series Accessories Switches & Pilot Lights Mounting Mounting Accessories and Sockets Style Appearance Applicable Hold-Down Springs Use with Timers Part No. GT5P SR2P-05 8-Pin Screw Terminal (dual tier) Appearance Part No. Display Lights SFA-203 8-Pin Fingersafe Socket GT5P SR2P-05C 8-Pin Screw Terminal GT5P SR2P-06 -- BNDN1000 DIN Rail/ Surface Mounting Accessories 8-Pin Solder Terminal Applicable Hold-Down Springs SR2P-51 SFA-402 Terminal Blocks Installation of Hold-Down Springs DIN Rail Mount Socket Timers Part Numbers: Mounting Accessories and Sockets Mounting Accessories Relays & Sockets DIN Mounting Rail Length 1000mm SFA-202 Panel Mount Socket Hold-down Spring SFA-402 Insert the springs into the outer slots with the projections facing inside. Insert the springs into the slots. Insert 8-pin Socket SR2P-51 Hold-down Spring (sold separately) SFA-202 (use two springs) Circuit Breakers Socket SR2P-05 Socket SR2P-06 Hold-down Spring (sold separately) SFA-203 (use two springs) USA: 800-262-IDEC Canada: 888-317-IDEC 851 Timers GT5P Series Switches & Pilot Lights GT5P Timer, 8-Pin with SR2P-06 Circuit Breakers Terminal Blocks Timers Relays & Sockets GT5P Timer, 8-Pin with SR2P-05 Display Lights Dimensions 852 www.idec.com Timers GT5Y Series GT5Y Series -- ON Delay Timers Switches & Pilot Lights Key features of the GT5Y series include: * * * * * * 4PDT, 3A or DPDT, 5A contacts 4 time ranges Repeat error 0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same sockets and hold-down clips as IDEC's RY4S and RU series relays UL, c-UL Listed File No. E55996 Display Lights Specifications GT5Y-2 100 to 120V AC (50/60Hz) 200 to 240V AC (50/60Hz) 24V DC 24V AC 12V DC Rated Operating Voltage DPDT 4PDT Resistive Load 220V AC, 5A 30V DC, 5A 220V AC, 3A 30V DC, 3A Inductive Load 220V AC, 2A 30V DC, 2.5A 220V AC, 0.8A 30V DC, 1.5A Resistive Load 1100VA AC 150W DC 660VA AC 90W DC Inductive Load Cos o = 0.3 L/R = 7msec 440VA AC 75W DC 176VA AC 45W DC Rated Load Allowable Voltage Temperature Error 250V AC, 125V DC 5A 3A 3% maximum (over -10 to 50C, reference temperature 20C) Setting Error Reset Time 10% maximum When turning power off after time up: 0.1 second maximum When turning power off before time up: 1 second maximum Insulation Resistance Dielectric Strength Vibration Resistance Power Consumption Electrical Life Mechanical Life 100M minimum 2,000V AC, 1 minute (except between contacts of the same pole) 100N (approximate 10G) Terminal Blocks Shock Resistance Timers Allowable Current Relays & Sockets Contact Form Allowable Contact Power GT5Y-4 Operating extremes: 100N (approximate 10G) Damage limits: 500N (approximate 50G) 100V AC type: 1.5VA (at 50Hz) 200V AC type: 1.6VA (at 50Hz) 24V DC type: 0.9W 500,000 operations minimum (220V AC, 5A) 200,000 operations minimum (110V AC, 3A) 50,000,000 operations minimum -10 to +50C Operating Humidity 45 to 85% RH Circuit Breakers Operating Temperature 1. Minimum applicable load: GT5Y-2: 5V DC, 20mA (reference value); GT5Y-4: 5V DC, 10mA (reference value). 2. Inductive load: cos o =0.3, L/R=7msec. USA: 800-262-IDEC Canada: 888-317-IDEC 853 Timers GT5Y Series Switches & Pilot Lights Part Numbering List Mode of Operation Contact Output Rated Voltage 100 to 120V AC 200 to 240V AC Display Lights DPDT 220V AC/ 30V DC, 5A 12V DC 24V DC 24V AC ON-Delay Relays & Sockets 100 to 120V AC 200 to 240V AC 4PDT 220V AC/30V DC, 3A 12V DC Timers 24V DC 24V AC Time Range Complete Part No. 1S/10S/1M/10M GT5Y-2SN1A100 3S/30S/3M/30M GT5Y-2SN3A100 6S/60S/6M/60M GT5Y-2SN6A100 1S/10S/1M/10M GT5Y-2SN1A200 3S/30S/3M/30M GT5Y-2SN3A200 6S/60S/6M/60M GT5Y-2SN6A200 1S/10S/1M/10M GT5Y-2SN1D12 3S/30S/3M/30M GT5Y-2SN3D12 6S/60S/6M/60M GT5Y-2SN6D12 1S/10S/1M/10M GT5Y-2SN1D24 3S/30S/3M/30M GT5Y-2SN3D24 6S/60S/6M/60M GT5Y-2SN6D24 1S/10S/1M/10M GT5Y-2SN1A24 3S/30S/3M/30M GT5Y-2SN3A24 6S/60S/6M/60M GT5Y-2SN6A24 1S/10S/1M/10M GT5Y-4SN1A100 3S/30S/3M/30M GT5Y-4SN3A100 6S/60S/6M/60M GT5Y-4SN6A100 1S/10S/1M/10M GT5Y-4SN1A200 3S/30S/3M/30M GT5Y-4SN3A200 6S/60S/6M/60M GT5Y-4SN6A200 1S/10S/1M/10M -- 3S/30S/3M/30M GT5Y-4SN3D12 6S/60S/6M/60M -- 1S/10S/1M/10M GT5Y-4SN1D24 3S/30S/3M/30M GT5Y-4SN3D24 6S/60S/6M/60M GT5Y-4SN6D24 1S/10S/1M/10M GT5Y-4SN1A24 3S/30S/3M/30M GT5Y-4SN3A24 6S/60S/6M/60M GT5Y-4SN6A24 Terminal Blocks For sockets and accessories, see page 856. Timing Ranges Code 1S Time Range Indication Time Range x 0.1 S x1 S 0.2 second to 10 seconds x 0.1 M 1.2 seconds to 1 minute 10M x1 M 12 seconds to 10 minutes 3S x1 S 0.1 second to 3 seconds x 10 S 0.5 second to 30 seconds x1 M 3 seconds to 3 minutes 30M x 10 M 30 seconds to 30 minutes 6S x1 S 0.1 second to 6 seconds 60S x 10 S 1 second to 60 seconds x1 M 6 seconds to 6 minutes x 10 M 1 minute to 60 minutes 10S 1M Circuit Breakers Scale 30S 3M 6M 60M 854 0 to 10 0 to 3 0 to 6 0.1 second to 1 second www.idec.com Timers GT5Y Series Timing Diagram/Schematics/Electrical Life Curves GT5Y-4 DPDT 4PDT Switches & Pilot Lights GT5Y-2 Internal Connections (bottom view) Power 13 - 14 Delayed Contact 1 - 9, 2 - 10 3 - 11, 4 - 12 5 - 9, 6 - 10 7 - 11, 8 - 12 Operation (NC) (NO) POWER Indicator OUT For an explanation of timing modes, see page 794. Relays & Sockets Electrical Life Curves 5000 AC Load 1000 110V AC Resis. Load 220V AC Resis. Load 110V AC Induc. Load 220V AC Induc. Load 500 100 50 Timers Life (x 10,000 operations) GT5Y-2 GT5Y-4 10 0 1 2 3 4 5 Load Current (A) 5000 DC Load GT5Y-2 GT5Y-4 30V DC Resis. Load 30V DC Induc. Load 100V DC Resis. Load 100V DC Induc. Load 1000 500 Terminal Blocks Life (x 10,000 operations) Operation Mode: ON-Delay Terminal Number Display Lights Item Set Time 100 50 10 0 1 2 3 4 5 Load Current (A) Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 855 Timers GT5Y Series Switches & Pilot Lights Accessories DIN Rail Mounting Accessories DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Style Applicable Hold-Down Springs Appearance Part No. 14-Blade Screw Terminal Appearance Part No. SY4S-05 Relays & Sockets Display Lights SFA-202 14-Blade Screw Terminal (fingersafe) SY4S-05C DIN Mounting Rail Length 1000mm BNDN1000 Panel Mounting Accessories Part Numbers: Panel Mount Socket and Hold-Down Springs Panel Mount Socket Style Appearance 14-Blade Solder Terminal Applicable Hold-Down Springs Part No. Appearance Part No. SFA-302 Timers SY4S-51 PCB Mounting Accessories Part Numbers: PCB Mount Sockets with Applicable Hold-Down Springs PCB Mount Socket Appearance Part No. Appearance Part No. 14 Blade, PCB Terminal SY4S-61 SFA-302 14 Blade, PCB Terminal SY4S-62 SY4S-02F1 Circuit Breakers Terminal Blocks Style Applicable Hold-Down Springs 856 www.idec.com Timers GT5Y Series Dimensions Switches & Pilot Lights GT5Y Timer, Blade with SY4S-05 When using BAA/BAP: 28.5 0.7 30 When using DIN Rail When using BAA/BAP: 87.6 maximum 6 M3 Terminal Screw 58.6 6.4 Holddown Spring DIN Rail (BAA/BAP) 2-o4.2 Mounting Holes (or M4 Tapped Holes) 45 DIN Rail 26 Terminal Arrangement 8 7 6 5 4 3 2 1 26 4 max. 4.8 min. 14 13 12 11 10 9 18.5 18.5 25 18 4.2 52.6 3 6 3 21 62 62 27.5 83.6 maximum 25 (Top View) 5.9 max. o3.2 min. Display Lights Relays & Sockets Timers Terminal Blocks Circuit Breakers USA: 800-262-IDEC Canada: 888-317-IDEC 857 Timers General Instructions Relays & Sockets Display Lights Switches & Pilot Lights General Instructions for All Timer Series Load Current Vibration and Shock With inductive, capacitive, and incandescent lamp loads, inrush current more than 10 times the rated current may cause welded contacts and other undesired effects. The inrush current and steady-state current must be taken into consideration when specifying a timer. Excessive vibration or shocks can cause the output contacts to bounce, the timer should be used only within the operating extremes for vibration and shock resistance. In applications with significant vibration or shock, use of hold down springs or clips is recommended to secure a timer to its socket. Contact Protection Time Setting Switching an inductive load generates a counter-electromotive force (back EMF) in the coil. The back EMF will cause arcing, which may shorten the contact life and cause imperfect contact. Application of a protection circuit is recommended to safeguard the contacts. The time range is calibrated at its maximum time scale; so it is desirable to use the timer at a setting as close to its maximum time scale as possible. For a more accurate time delay, adjust the control knob by measuring the operating time with a watch before application. Temperature and Humidity Input Contacts Use the timer within the operating temperature and operating humidity ranges and prevent freezing or condensation. After the timer has been stored below its operating temperature, leave the timer at room temperature for a sufficient period of time to allow it to return to operating temperatures before use. Use mechanical contact switch or relay to supply power to the timer. When driving the timer with a solid-state output device (such as a two-wire proximity switch, photoelectric switch, or solid-state relay), malfunction may be caused by leakage current from the solid-state device. Since AC types comprise a capacitive load, the SSR dielectric strength should be two or more times the power voltage when switching the timer power using an SSR. Environment Avoid contact between the timer and sulfurous or ammonia gases, organic solvents (alcohol, benzine, thinner, etc.), strong alkaline substances, or strong acids. Do not use the timer in an environment where such substances are prevalent. Do not allow water to run or splash on the timer. Generally, it is desirable to use mechanical contacts whenever possible to apply power to a timer or its signal inputs. When using solid state devices, be cautious of inrushes and back-EMF that may exceed the ratings on such devices. Some timers are specially designed so that signal inputs switch at a lower voltage than is used to power the timer (models designated as "B" type). Timing Accuracy Formulas Timers Timing accuracies are calculated from the following formulas: Repeat Error = 1 x Maximum Measured Value - Minimum Measured Value x 100% 2 Maximum Scale Value Voltage Error = Tv - Tr x 100% Tr Tv: Average of measured values at voltage V Tr: Average of measured values at the rated voltage = Tt - T20 x 100% T20 Tt: Average of measured values at C T20: Average of measured values at 20C Setting Error = Average of Measured Values - Set Value x 100% Maximum Scale Value Circuit Breakers Terminal Blocks Temperature Error 858 www.idec.com