Commercial Wire Family
FlexLite DW (Continued)
9-48 Catalog 1654025 Dimensions are in millimeters Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-3611-1514
Revised 12-04 and inches unless otherwise reference purposes only. Canada: 1-905-470-4425 Japan: 81-44-900-5102
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Singapore: 65-4866-151
www.tycoelectronics.com are U.S. equivalents. to change. C. America: 52-55-5-729-0425 UK: 44-1793-528171
Construction Details
Finished Wire
Wire Conductor Nominal Maximum Diameter Nominal
Part No. Size Stranding Diameter Resistance Minimum Nominal Maximum Weight in
(AWG) (No. x AWG) mm [inch] at 20°C (68°F) mm [inch] mm [inch] mm [inch] kg/km
Ω/km [Ω/1000 ft] [lb/1000 ft]
FLDWC0311-26-* 26 19 x 38 .470 [.0185] 132 [40.1] .965 [.038] 1.02 [.040] 1.07 [.042] 2.38 [1.6]
FLDWC0311-24-* 24 19 x 36 .597 [.0235] 83.3 [25.4] 1.12 [.044] 1.17 [.046] 1.22 [.048] 3.57 [2.4]
FLDWC0311-22-* 22 19 x 34 .749 [.0295] 52.2 [15.9] 1.32 [.052] 1.37 [.054] 1.42 [.056] 5.21 [3.5]
FLDWC0311-20-* 20 19 x 32 .953 [.0375] 32.0 [9.76] 1.52 [.060] 1.57 [.062] 1.63 [.064] 7.59 [5.1]
FLDWC0311-18-* 18 19 x 30 1.18 [.0465] 20.4 [6.22] 1.78 [.070] 1.85 [.073] 1.93 [.076] 11.46 [7.7]
FLDWC0311-16-* 16 19 x 29 1.33 [.0525] 15.8 [4.82] 1.98 [.078] 2.06 [.081] 2.13 [.084] 14.58 [9.8]
FLDWC0311-14-* 14 19 x 27 1.68 [.0660] 10.0 [3.05] 2.39 [.094] 2.49 [.098] 2.59 [.102] 21.88 [14.7]
FLDWD0311-12-* 12 37 x 28 2.16 [.0850] 6.59 [2.01] 2.87 [.113] 2.97 [.117] 3.07 [.121] 32.89 [22.1]
*Replace asterisk with color code designator:
0=Black 3 = Orange 7 = Violet
1 = Brown 4 = Yellow 8 = Gray
2=Red 5 = Green 9 = White
For example: FLDWC0311-20-9 = AWG 20, white.
Construction Details
Finished Wire
Nominal Wire Conductor Diameter Maximum Diameter Nominal
CSA Size Stranding (min.) (max.) Resistance Lower Target Upper Weight in
Part No. (mm2) (No. x Dia.) at 20°C (68°F) Spec. Limit Value Spec. Limit kg/km
mm [inch] mm [inch] Ω/km [Ω/1000 ft] mm [inch] mm [inch] mm [inch] [lb/1000 ft]
FLDWC0311-0.25* 0.25 19 x 0.127 0.55 [.022] 0.63 [.025] 83.6 [25.5] 1.12 [.044] 1.17 [.046] 1.22 [.048] 3.77 [2.53]
FLDWC0311-0.35* 0.35 19 x 0.15 0.72 [.028] 0.77 [.030] 56.1 [17.1] 1.31 [.052] 1.37 [.054] 1.42 [.056] 5.17 [3.46]
FLDWC0311-0.50* 0.50 19 x 0.19 0.86 [.034] 0.88 [.035] 40.1 [12.2] 1.46 [.057] 1.51 [.059] 1.56 [.061] 6.92 [4.64]
FLDWC0311-0.75* 0.75 19 x 0.23 1.05 [.041] 1.08 [.043] 24.7 [7.53] 1.65 [.065] 1.70 [.067] 1.75 [.069] 9.53 [6.39]
FLDWC0311-1.00* 1.00 19 x 0.25 1.17 [.046] 1.26 [.050] 20.0 [6.1] 1.78 [.070] 1.85 [.073] 1.93 [.076] 11.88 [7.96]
FLDWC0311-1.50* 1.50 19 x 0.32 1.46 [.057] 1.51 [.059] 13.7 [4.2] 2.21 [.095] 2.28 [.090] 2.36 [.093] 17.88 [11.98]
*Replace asterisk with color code designator:
0=Black 3 = Orange 6 = Blue 9 = White
1 = Brown 4 = Yellow 7 = Violet
2=Red 5 = Green 8 = Gray
For example: FLDWC0311-20-9 = AWG 20, white.
FLDWC0311-1.00-9 = Size 1.00 mm2,white.
For product requiring CUR (Canadian UL) or CSA marking in 14-10 AWG, 19 strand conductors only, the part numbering
descriptions above DO NOT apply. Please contact Tyco Electronics for further information.