Micro Commercial Corp.
21201 Itasca St.
Chatsworth, CA 91311
Phone: (818) 701-4933
Fax: (818) 701-4939
MBR20020CT
THRU
MBR200100CT
200 Amp
Rectifier
20 to 100 Volts
Features
Operating Temperature: -65°C to +150°C
Storage Temperature: -65°C to +150°C
MCC
Part Number
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS Voltage
Maximum DC
Blocking
Voltage
MBR20020CT 20V 14V 20V
MBR20030CT 30V 21V 30V
MBR20035CT 35V 24.5V 35V
MBR20040CT 40V 28V 40V
MBR20045CT 45V 31.5V 45V
MBR20060CT 60V 42V 60V
MBR20080CT 80V 56V 80V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 200 A TA = 140°C
Peak Forward Surge
Current IFSM 1500A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage VF
IFM = 100 A;
TA = 25°C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 5 mA
TA = 25°C
Typical Junction
Capacitance CJ 300pF Measured at
1.0MHz, VR=4.0V
DIMENSIONS
INCH
ES MM
DIM MIN MAX MIN MAX NOTE
B 1.565 1.585 39.75 40.26
A 3.150 NOM 80.01 NOM
C .700 .800 17.78 20.32
E .119 .132 3.02 3.35
G 3.55 3.65 90.17 92.71
F 1.375 REF 34.92 REF
H .590 .620 14.99 15.75
J 1/4 - UNF FULL
K .380 .410 9.65 10.41
MCC
www.mccsemi.com
Schottky Barrier
Maximum Ratings
Metal of siliconrectifier, majonty carrier conducton
Guard ring for transient protection
Low power loss high efficiency
High surge capacity, High current capability
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
20020-20045CT
20060CT
20080-200100CT
.63 V
.84 V
.75 V
MBR200100CT 100V 70V 100V
FULL PACK
A
B
C
D
E
F
G
H
J
K
L
M
L .185 .195 4.70 4.95
L .275 .295 6.99 7.49
Junct i on Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Vol ts
Figure 1
Typical Forward Characteri stics
40
60
200
100
Amps
0.6 0.8 1.0 1.4 1.8 2.0
.1
.2
.4
.6
1
2
4
6
10
20 25°C
Volts
Figure 3
Junct i on Capacitance
.1 .2 1.4 2 10 20 404 100 200
10
20
60
100
200
1000
pF
Volts
600
400
40
400 1000
TJ=25°C
MBR200 20CT thru MBR200100CT
www.mccsemi.com
MCC
Average Forward Rectifi ed Current - Amperes versus
Ambi ent Temperat ure - °C
Figure 2
Forward Derating Curve
0
150
50 70 90 110
0
20
40
80
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
130
120
160
200
MBR20020CT thru MBR200100CT
www.mccsemi.com
MCC
Inst ant aneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - V ol ts
Figure 4
Typical Revers e Characteris tics
Volts
40
60
200
100
mAmps
10
100
20 40 60 80
.1
.2
.4
.6
1.0
2.0
3.0
4.0
5.0
20
TA=25°C
400
600
1000
120
TA=125°C1 100
4
0
100
300
600
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2610 20 60 80
40
900
1200
1500