93
XTRA
GUARD®Flexible Cables
HIGH-FLEX CONTROL CABLE
CONTINUOUS FLEXING, OIL RESISTANT, MULTICONDUCTOR, SHIELDED
12 AWG (4,0mm
2
), 413/38 (413/0,1mm), Insulation Thickness: 0.022" (0,56mm)
85204CY 4 0.075 1,9 0.646 16,4
85207CY 7 0.100 2,5 0.814 20,7
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
10 AWG (6,0mm
2
), 658/38 (658/0,10mm), Insulation Thickness: 0.022" (0,56mm)
85104CY 40.070 1,80 0.706 17,9
85107CY 70.100 2,50 0.934 23,7
Alpha No. of Jacket Thickness Nominal Diameter
PartNo. Cond. Inches mm Inches mm
UL AWM STYLE 2587
CSA AWM II A/B FT1
600 VOLT
CHARACTERISTICS
OPERATING TEMPERATURE:
–5°C to 90°C (Flexing)
–40°C to 90°C (Stationary)
VOLTAGE RATING:
600 Volt
COLOR DESCRIPTION:
Color Code: Numerically Numbered (Alternate and
Inverted) Red Conductors with One Green/Yellow
Conductor on Outside Layer
Jacket Color: Black
PRODUCT DESCRIPTION:
Conductor: Super Finely Stranded Bare Copper
Insulation: Lubricated PVC
Fillers: Non-Wicking, Solid PVC Rod
Wrap: Non-Wicking Fabric
Inner Jacket: PVC
Shield: Tinned Copper Braid (85% Coverage)
Outer Jacket: Oil Resistant PVC
SPECIFICATIONS
Bend Radius: 10X Cable Diameter
UL AWM Style 2587
CSA AWM II A/B FT1
Jacket Meets VDE 0472, Section 803 Oil Test
Passes MIL-C-13777G Flexlife Test
CE LVD-CD 73/23/EEC Modified by CD 93/68/EEC
CHOOSE
XTRAGUARD
HIGH-FLEX CONTROL
CABLES FOR
:
Extra Flexibility and Durability for Continuous Motion
Extended Cycle Life 13.8 Million
(Test Report Available)
Outstanding Oil and Chemical Resistance
Jacket Meets VDE 0472, Section 803 Oil Test
UL Recognized and CSA Certified, CE Marked
XTRAGUARD
HIGH-FLEX
CONTROL CABLE APPLICATIONS
:
Applications Requiring Continuous Flexing
Robotics
Installation in Cable Track
Assembly Lines
Automation Equipment
Material Handling Equipment
AVAILABILITY
In Stock: Bulk, Cut to Length
20 AWG (0,5mm
2
), 65/38 (65/0,1mm), Insulation Thickness: 0.022" (0,56mm)
85003CY 3 0.035 0,89 0.353 9,0
85004CY 4 0.035 0,89 0.374 9,5
85005CY 5 0.040 1,00 0.416 10,6
85007CY 7 0.040 1,00 0.471 12,0
85010CY 10 0.040 1,00 0.551 14,0
85012CY 12 0.050 1,30 0.567 14,4
85018CY 18 0.060 1,50 0.658 16,7
85025CY 25 0.070 1,80 0.791 20,1
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
18 AWG (1,0mm
2
), 105/38 (105/0,1mm), Insulation Thickness: 0.022" (0,56mm)
85803CY 3 0.035 0,89 0.373 9,5
85804CY 4 0.040 1,00 0.407 10,3
85805CY 5 0.040 1,00 0.444 11,3
85807CY 7 0.050 1,30 0.520 13,2
85812CY 12 0.060 1,50 0.625 15,9
85818CY 18 0.060 1,50 0.708 18,0
85825CY 25 0.080 2,00 0.867 22,0
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
16 AWG (1,5mm
2
), 168/38 (168/0,1mm), Insulation Thickness: 0.022" (0,56mm)
85603CY 3 0.035 0,89 0.422 10,7
85604CY 4 0.040 1,00 0.461 11,7
85605CY 5 0.040 1,00 0.500 12,7
85607CY 7 0.060 1,50 0.599 15,2
85612CY 12 0.060 1,50 0.702 17,8
85618CY 18 0.060 1,50 0.797 20,2
85625CY 25 0.065 1,70 0.962 24,4
Alpha No. of Jacket Thickness Nominal Diameter
PartNo. Cond. Inches mm Inches mm
14 AWG (2,5mm
2
), 266/38 (266/0,10mm), Insulation Thickness: 0.022" (0,56mm)
85404CY 40.050 1,30 0.538 13,7
85407CY 70.065 1,70 0.676 17,2
Alpha No. of Jacket Thickness Nominal Diameter
Part No. Cond. Inches mm Inches mm
®
MADE IN U.S.A.
FIT
®TUBING RECOMMENDATION
FIT
®FLEX Highly Flexible, Irradiated Silicone Rubber
(See Page 134 for Product Specifications)
FIT
®-650 Chemical and Temperature Resistant Irradiated Viton®
(See Page 132 for Product Specifications)
Viton®is a registered trademark of DuPont Dow Elastomers
Web Site: www.alphawire.com Toll Free: 1-800-52 ALPHA • Telephone: 908-925-8000 • Fax: 908-925-6923
Email: info@alphawire.com Europe/UK Telephone: +44 (0) 1932 772422 • Europe/UK Fax: +44 (0) 1932 772433