Current Transducers HTB 50..400-P and HTB 50..100-TP IPN DC = 50 .. 400 A For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data Primary continuous direct current (nominal) IPN DC (A) 50 100 200 300 400 VC IC Vd RIS VOUT ROUT RL Primary current, measuring range IPM (A) 150 300 500 600 600 Type RoHS since date code Features HTB 50-P, HTB 50-TP1) HTB 100-P, HTB 100-TP1) HTB 200-P HTB 300-P HTB 400-P 46104, 46166 45178, 46183 45198 45225 46224 Supply voltage ( 5 %) 2) 12 .. 15 Current consumption < 15 Rms voltage for AC isolation test, 50 Hz, 1 min 2.5 Isolation resistance @ 500 VDC > 500 Output voltage (Analog) @ IPN DC, RL = 10 k, TA = 25C 4 Output internal resistance 100 Load resistance 10 V mA kV M V k Accuracy - Dynamic performance data X L VOE VOH TCVOE TCVOUT tr BW Accuracy @ IPN DC, TA = 25C (excluding offset) Linearity error (0 .. IPN DC) Electrical offset voltage, TA = 25C Hysteresis offset voltage @ IP = 0; after an excursion of 1 x IPN DC Temperature coefficient of VOE HTB 50-(T)P HTB 100-(T)P..400-P Temperature coefficient of VOUT (% of reading) Response time to 90% of IPN DC Frequency bandwidth (0..-3 dB) 3) and secondary circuit * Isolation voltage 2500V * Low power consumption * Wide power supply: 12V to 15V * Primary bus bar option for 50A and 100A version for ease of connection Advantages * Small size and space saving * Only one design for wide current ratings range < 1 % of IPN DC < 1 % of IPN DC < 30 mV < 1 % of IPN DC < 2.0 mV/K < 1.0 mV/K < 0.1 %/K <3 s DC .. 50 kHz * High immunity to external interference. Applications * AC variable speed drives * Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies (UPS) * Switched Mode Power Supplies (SMPS) General data TA TS m * Hall effect measuring principle * Galvanic isolation between primary * Power supplies for welding Ambient operating temperature - 20 .. + 80 C Ambient storage temperature - 25 .. + 85 C Mass (-TP version) < 30 (< 36) g Standards EN 50178: 1997 2 pins of O2mm diameter are available on transducer for PCB soldering. applications. Application domain * Industrial Notes : -TP version is equipped with a primary bus bar. 2) Operating at 12V Vc < 15V will reduce measuring range. 3) Derating is needed to avoid excessive core heating at high frequency. 1) Page 1/2 070313/11 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Dimensions HTB 50..400-P and HTB 50..100-TP (in mm. 1 mm = 0.0394 inch) HTB 50..400-P Positive Current Flow 39 9 +/-1 1.5 19.5 34 d1 6 14 MAX. 3.5 4321 4-0.635x0.635 24.5 Secondary Pin Identification 5.5 3-P=2.5 10 1 2 3 4 7 11 3 6 +/-1 2-d2 Mounting Pins 3 19 +Vc -Vc Output 0V General tolerance: 0.5 mm HTB 50..100-TP 39 10 1.5 1.5 3.5 3.5 44 3 2 1 4-0.635x0.635 4-0.635x0.635 3.5 3.5 1.5 1.5 17 34 14 14 MAX. MAX. 1.5 1.5 Positive Current Flow 10.5 3 3 3-P=2.5 3-P=2.5 3.25 3.25 6-1.5x1.5 6-1.5x1.5 3 3 11 11 33 14 14 22 6.5 6.5 Secondary Pin Secondary Pin Identification Identification 11 22 33 44 +Vc +Vc -Vc -Vc Output Output 0V 0V General tolerance: 0.5 mm Page 2/2 070313/11 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com