Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance 3-phase RFI Filters for WYE Applications A Series UL Recognized CSA Certified VDE Approved A Series Specifications * For 3-phase, four wire, WYE Applications * Filters each of the three lines plus the neutral and ground line * Both common mode and differential mode suppression from 50kHz to 30MHz * Effective for both balanced and unbalanced loads * Ground choke included Maximum leakage current, each Line to Ground: @ 120 VAC 60 Hz: 1.4 mA @ 250 VAC 50 Hz: 3.4 mA Hipot rating (one minute): Line to Ground: Neutral to Ground: Line to Neutral: 1500 VAC 1500 VAC 1450 VDC * Optional end bell kits available to shield input and output terminals Rated Voltage (max): Phase to Phase: Phase to Neutral / Ground: 440 VAC 250 VAC * AYP single stage for lower noise environments Operating Frequency: 50/60 Hz * AYT dual stage provides highest performance Rated Current: Ordering Information 45 AYT 6 C 20 to 60A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics Suffix C - Ground Choke Input / Output Style 6 - Threaded 1/4 - 20 bolt AYP6C Models LINE A LOAD A Series designation AYP - Single Stage AYT - Dual Stage B B C C Current Rating 20, 30, 45 or 60A N N LINE GND LOAD GND 98 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance 3-phase RFI Filters for WYE Applications (continued) A Series Electrical Schematics (continued) Case Style AYT6C Models LINE A B B C C N LINE GND LOAD GND N A C E LOAD A D B 2 Available Part Numbers 20AYT6C 30AYT6C 45AYT6C 60AYT6C Terminals: 1/4 x 20 (10) Torque: Three Phase Filters 20AYP6C 30AYP6C 45AYP6C 60AYP6C Mounting studs: No. 8-32 (8) 56 lbf-in 2 6.33 N-m .23 Accessories Mounting bracket kit with captive nuts: AA400: 20A & 30A versions Case Dimensions AA405: 45A & 60A versions Part No. AA406A AA407A 20AYP6C AA405 30AYP6C Protective cover for use with mounting bracket: (For Europe only. Limited availability in other regions) AA406A: 20A & 30A versions 45AYP6C AA400 AA407A: 45A & 60A versions End bell kit (bracket and cover) with captive nuts: 60AYP6C 20AYT6C AA406: 20A & 30A versions 30AYT6C AA407: 45A & 60A versions AA406 / AA407 45AYT6C Kits includes both bracket and cover 60AYT6C Additional captive nuts: A* B C D E AA401: 10 nuts 99 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance 3-phase RFI Filters for WYE Applications (continued) A Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 20AYP6C 30AYP6C 45AYP6C 60AYP6C db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.01 0.1 0.15 1 10 30 Frequency in MHz 0.01 0.1 0.15 1 10 30 Frequency in MHz 10 0.01 0.1 0.15 1 0 10 30 Frequency in MHz 0.01 0.1 0.15 20AYT6C 30AYT6C 45AYT6C 60AYT6C db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.01 0.1 0.15 1 10 30 Frequency in MHz 0.01 0.1 0.15 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 80 10 0.01 0.1 0.15 1 0 10 30 Frequency in MHz 0.01 0.1 0.15 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system AYP6C Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) AYT6C Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 100 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com