NOTICE - These drawings, specificati ons, or other data (1) are, and rema in the
are given by Amphenol Corp. The fur nishing of these drawings, specifica tions, or
not to be regarded by implication or otherwise in any manner licensing, granting
confidential and not to be disclosed to any person other than those to w hom they
other data by Amphenol Corp., or to any other person to anyone for any p urpose is
rights or permitting such holder or any other person to manufacture, use or sell any
product, process or design, patented or otherwise, that may in any way b e related to
UNLESS OTHERWISE SPECIFIED, DIMENSIO NS ARE IN INCHES AND TOLERANCES ARE:
property of Amphenol Corp. (2) must be returned upon request; and (3) ar e
or disclosed by said drawings, speci fications, or other data.
#.015 (0,381 mm)
REFERENCE
MATERIAL
#.005 (0,127 mm)
3 PLACE DECIMAL2 PLACE DECIMAL ANGLES
# 1 $
CAD FILE
APPROVED
ENGINEER
DRAWN
THIRD ANGLE PROJ.
DRAWING NO.
TITLE
DATE
DATE
DATE
DRAWING NO.DWG SIZE
B
SCALE:
REV
SHEET OF
DATEDESCRIPTIONREV
REVISIONS
ECO APPR
335104-08-XXXX
12.0:1 11
335104-08-XXXX
Amphenol
Connex
LENGTH XXXX MM (SEE TABLE)
KARTHIK R 24-Sep-10 MICRO COAX CABLE
PLUG TO PLUG,
USING RG-178 CABLE
XXXX MM, LENGTH
KARTHIK R 24-Sep-10
TASK - 429
Root Folder/Cable_Assy/ 335104-08-XXXX A
A RELEASE TO MFG. 24-Sep-10 -- KR
INS. LOSS ____________ dB MAX OTHER
VSWR ____________ : 1 MAX X HI-POT : 250 VRMS
FREQUENCY____________ TO ________________ GHz XCONTINUITY
DESIGN REQUIREMENTS:
QTY ITEM DESCRIPTION FINISH
1 1 W.FL PLUG
A/R 2 1.13MM CABLE
BLACK
1 3 U.FL PLUG
CONNEX NUMBER CABLE LENGTH (IN) CABLE LENGTH (MM)
335104-08-0050 1.968 #0.150 50 #3.81
335104-08-0100 3.936 #0.150 100 #3.81
335104-08-0150 5.905 #0.150 150 #3.81
335104-08-0200 7.873 #0.200 200 #5.08
335104-08-0250 9.842 #0.200 250 #5.08
335104-08-0300 11.810 #0.200 300 #5.08
NOTES:
1. PACKAGE CABLE ASSEMBLY IN BAG. TAG IN BAG WITH "AMPHENOL CONNEX, 335104-08-XXXX AND DATE CODE".
2. CABLE ASSEMBLY TO BE 100% TESTED FOR HI-POT, CONTINUITY, SHORTS AND OPEN.
* ADDITIONAL LENGTHS CAN BE PROVIDED
BY CHANGING XXXX TO DESIRED LEGNTH IN MM
CONTACT CONNEX MARKETING FOR QUOTE
ORIENT MICRO-COAXIAL INTERFACE WITH
RESPECT TO MICRO-COAXIAL INTERFACE
AS SHOWN WITH IN #10$