AN48840B
37
■ Absolute Maximum Ratings
Parameter Symbol Rating Unit
Supply voltage VCC 5V
Output voltage VOUT 5V
Supply current ICC 5mA
Output current IOUT 15 mA
Power dissipation *1, *2PD60 mW
Operating ambient temperature *1Topr −25 to +75 °C
Storage temperature *1Tstg −55 to +125 °C
Note) *1: Except for the power dissipation, operating ambient temperature and storage temperature, all ratings are for Ta = 25°C.
*2: Ta = 75°C. For the independent IC without a heat sink. Please use within the range of power dissipation, refering to PD Ta curve.
■ Recommended Operating Range
Parameter Symbol Range Unit
Supply voltage VCC 2.5 to 3.5V
■ Electrical Characteristics Ta = 25°C ± 2°C
Parameter Symbol Conditions Min Typ Max Unit
Operating magnetic flux density 1
*1BHL VCC = 3 V, VCC = 2.5 V 0.56mT
Operating magnetic flux density 2
*2BLH VCC = 3 V, VCC = 2.5 V −6 − 0.5mT
Output voltage 1VOL1VCC = 3 V, IO = 2 mA, B = 6.0 mT 0.1 0.3V
Output voltage 1VOL2VCC = 2.5 V, IO = 2 mA, B = 6.0 mT 0.1 0.3V
Output voltage 2VOH1VCC = 3 V, IO = −2 mA, B = −6.0 mT 2.7 2.9V
Output voltage 2VOH2VCC = 2.5 V, IO = −2 mA, B = −6.0 mT 2.7 2.9V
Supply current 1 *3ICCAVE VCC = 3 V 56.0 85.0µA
Supply current 2 *3ICC2AVE VCC = 2.5 V 48.0 72.0µA
Intermittent action time Tsam VCC = 3 V 490 670 850 µS
Intermittent action time 2Tsam2VCC = 2.5 V 513 710 890 µS
Note) *1: Symbol BH-LS , BH-LN stands for the operating magnetic flux density where its output level varies from high to low.
*2: Symbol BL-HS , BL-HN stands for the operating magnetic flux density where its output level varies from low to high.
*3: ICCAVE = {ICCON × tON + ICCOFF × tOFF}/{tON + tOFF}
Design reference data
Parameter Symbol Conditions Min Typ Max Unit
Hysteresis width BW VCC = 3 V 7mT
Supply current 3ICCON VCC = 3 V 1.4 2.1mA
Supply current 4ICCOFF VCC = 3 V 2.5 µA
Supply current 5ICC2ON VCC = 2.5 V 1.12 1.68 mA
Supply current 6ICC2OFF VCC = 2.5 V 2.2 µA
Operating time tON Ta = −25°C to 75°C, VCC = 3 V 10 26 42 µS
Stop time tOFF Ta = −25°C to 75°C, VCC = 3 V 258 644 1 030 µS
Operating time 2t2ON Ta = −25°C to 75°C, VCC = 2.5 V 11 27 43 µS
Stop time 2t2OFF Ta = −25°C to 75°C, VCC = 2.5 V 270 674 1 078 µS
Note) It will operate normally in approximately 0.67 ms after power on.