A. Electrical Specifications
(1) AC Input Voltage Rating
AC Input Voltage Range
(2) Input Surge Current
(3) DC Output Adjustment Range
(4) Line Regulation
(5) Load Regulation
(6) Output Ripple and Noise
(7) Hold-up Time
(8) Output Transient Response
(9) Output Voltage Rise Time
(10) Efficiency
(11) Overload Protection
(12) OverVoltage Protection
(13) Leakage Current
(14) Overshoot
(15) Output Voltage Stability
(16) Temperature Coefficient
(17) Remote/Local Sensing
(18) (18) Remote ON/OFF Control
AC115V/AC230V by Manual Voltage Selector,
50/60Hz (47 - 63Hz)
AC90 – 132V
AC180 - 264V
30A MAX at nominal line (115/230V) cold start
± 10% MIN
± 0.5% MAX under specified input range
± 0.5% MAX from no load to full rated load
5 - 15V output 75mVp-p MAX
24V output 120mVp-p MAX DC to 20MHz BW
20msec MIN under nominal line and rated load
1msec MAX over ±2% of rated voltage
under 50 - 100% load change
100msec MAX, from 10% to 90% of rated output voltage
70% MIN at nominal line and rated load
120% TYP of rated load, fold-back limiting type
5V output 5.7 - 6.7V
12V output 14.25 - 15.75V
15V output 17.25 - 18.75V
24V output 27.0 - 29.0V
0.75mA rms MAX
No overshoot during turn ON/OFF
± 0.1% MAX for 8 hours after 20 minute warm-up
±0.02% per deg. C MAX
Built-in
Built-in F, G, H and J Series, 300uA MIN
< 1V for inhibit, > 4.5V for ON
FILE NAME: CAD1:MSWORD:PA212243.DOC SCALE: NONE REV: - DATE: 10/27/99 SH 2 OF 7
TITLE:
43352 BUSINESS PARK DRIVE • TEMECULA • CA • 92590
TEL: (909) 699-1270 • FAX: 9096769482 DOCUMENT NUMBER:
P-A2-12243