IDH number: 270640 Produc t name: Di el ect ric Grease
Page 2 of 5
Eye contact: Get medical attenti on. Immedi ately fl ush eyes with plenty of water for at least
15 minutes. Check for and rem ove any contact lenses.
Ingestion: Do not induce vomiting. Get medical at tention.
5. FIRE FIGHTING MEASURES
Flash point: > 260 °C (> 500°F) HST-US D09F; Flash/Fire Point By Cleveland Open Cup
Autoignition temperature: Not determi ned
Flammable/Explosive limits - lower: Not available.
Flammable/Explosive limits - upper: Not available.
Extinguishing media: Water spray (f og), f oam, dry chemical or carbon di oxide.
Special firefighting procedures: Water should be used to cool closed cont ai ners to prevent pressure build-up
and possible aut oignit i on or explosion when exposed to extrem e heat. Wear a
self-cont ai ned breat hing apparat us with a full face piece operat ed in pressure-
demand or other positive press ure m ode.
Unusual fire or explosion hazards: None
Hazardous com bustion products: Oxides of carbon.
6. ACCIDENTAL RELEASE ME ASURES
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected
personnel.
Environmental precautions: Ventilate area. Do not allow product to enter sewer or waterways.
Clean-up methods: Scrape up spilled material and place in a closed container for disposal.
7. HANDLING AND STORAGE
Handling: Avoid contact with eyes, skin and clothing. Use only with adequate ventil ation.
Storage: Keep away from heat, spark and flame. Keep in a cool, well ventilated area.
For information on product shelf life contact Henkel Customer Service at (800) 243-4874.
8. EXPOSURE CONTROLS / PERSONAL PRO TECTION
Employers should complete an assessm ent of all workplaces to determine the need for, and selection of, proper exposure
controls and protective equipment for each task performed.
Hazardous components ACGIH TLV OSHA PEL AIHA W EEL OTHER
Dimethyl pol ysil oxane None None None None
Silica, amorphous, fumed, crystal-free
10 mg/m3 T WA
Inhalable dust .
3 mg/m3 T WA
Respirable f ract i on.
20 MPPCF TWA
0.8 mg/ m3 TWA None None
Engineering controls: Use local vent ilat i on if general venti lation is insufficient to maintain vapor
concent ration bel ow establi shed exposure limits.
Respiratory protection: Observe OSHA regulati ons for respirat ory use (29 CFR 1910.134). Use
NIOSH approved respi rator if there is potential to exceed exposure limit(s).
Eye/face protection: Safety goggl es or safety gl asses with side shiel ds.