SERIES IR Isolated Regulated up to 10 Watts DC-DC Converters Wide Input Range up to 3.33:1 Fully Regulated All Units Shielded New 100 VDC Output Models SERIES IR - SINGLE OUTPUT [ Now 2 Volts and 3.3 Volts DC OUTPUT AVAILABLE FEATURES: * Voltage regulation over input of LOW Hi IRE5V (15V IRF8V (24V IRA 18V 36V IRB 36V_ 60V IAC 18V 60V Encapsulated semiconductors conservatively rated for maximum reliability. * Load regulation (see table for typical variation at different loads) Line regulation = Typical values -15V DC =+1.5% 8-24 V DC = + 1.5% 18-36 V DG = + 1.0% 36-60 V DC = + 1.0% 18-60 V DC = + 1.5% * High efficiency-up to 84% * Will operate over a temperature range of -25C to +70C with no heat sink or electrical derating 6 sided shielding Isolation-100 megohms at 500 volts DC External output trimming pin standard, +5% Single and dual isolated outputs Each unit is supplied with an external control pin. This 'C pin, when connected to the negative (-) input, will disable the unit, allowing for remote shutdown, OPTIONS AVAILABLE Selected MIL-STD-883 Stabilization Bake (125C ambient) Temperature Cycle (-55C to +125C) Hi Temp, full power burn in (100% power, 125C case temp} * Expanded operating temp. (-55C to +85C) 92 INPUT OUTPUT EFE@ | CURRENT | RIPPLE + UNE MAX. MAX. FULL PULL @ FULL vio ree =| REGU PICO eur | ourpur | Loa | ourrur | Loap LOAD aD QUT VOLT | 26% - 100% | LATION PART VOLTAGE | VOLTAGE | CURRENT | POWER | TYPICAL | TYPICAL Bw TOLERANCE LOAD PRICE NUMBER | RANGE pe (ma) | qwarrs) | (%)* tmay | avppe | (2%)* | (2%)* | (2%)* 1-24 IRE2S 5-15 2 2000 4 68 588 250 1.50 5.00 5.50 128.40 (RE3.3S -15 3.3 1515 5 76 858 250 1.00 3.50 5.00 128.40 IRE5S -15 5 1200 6 80 750 175 0.75 2.00 2.00 128.40 IRES.2S -15 5.2 1154 6 80 750 175 0.75 2.00 2.00 128.40 IRESS -15 9 889 8 80 1000 150 0.50 1.50 1.00 128.40 fRE12S 5-15 12 667 8 78 1025 150 0.50 1.50 1.00 128.40 IRE15S 5-15 15 533 8 78 1025 150 0.50 1.50 1.00 128.40 IRE24S 5-15 24 333 8 82 975 150 0.50 0.75 1.00 128.40 IRE28S 5-15 28 286 8 83 965 200 0.50 0.50 0.50 128.40 IRE48S 5-15 48 187 8 83 905 250 0.50 0.50 0.50 428.40 5-15 100 60 6 &0 760 300 0.50 0.50 0.75 160.50 8-24 2 2600 5 70 446 250 1.50 4.00 4,00 128.40 8-24 3.3 2424 8 77 650 200 1.00 2.50 2.50 128.40 8-24 5 2000 10 80 780 200 0.75 1.50 1.75 128.40 8-24 .2 1923 10 80 780 200 0.75 1.50 1.76 128.40 8-24 9 1111 10 81 770 150 0.50 0.75 1.25 128.40 8-24 12 833 10 78 800 150 0.50 0.75 0.75 128.40 8-24 15 687 10 78 800 150 0.50 0.75 0.75 128.40 8-24 24 417 10 83 755 150 0.50 0.76 0.75 128.40 8-24 28 387 10 83 755 200 0.50 0.50 0.50 128.40 8-24 48 208 10 84 745 250 0.50 0.50 0.50 128.40 8-24 100 100 10 80 780 300 0.50 0.50 0.75 160.50 18-36 2 3000 6 71 313 200 1.50 4.00 2.50 128.40 18-36 33 2727 9 78 427 200 1.00 2.00 1.50 128.40 18-36 5 2000 10 a1 465 125 0.75 1.25 0.75 128.40 18-36 5.2 1923 10 81 455 125 0.75 1.25 0.75 128.40 18-36 9 4111 10 83 445 100 0.50 1.00 0.50 128.40 IRA12S 18-36 12 833 10 78 475 75 0.50 1.00 0.25 128.40 IRA15S 18-36 15 687 10 78 476 75 0.50 0.75 0.25 128.40 IRA24S 18-36 24 417 19 83 445 75 0.50 0.75 0.25 128.40 IRA28S 18-36 28 357 10 83 445 100 0.50 0.75 0.25 128.40 IRA4BS 18-36 48 208 10 84 440 150 0.50 0.60 0.25 128.40 | 1Ai00s_| 18. 100 100 19 81 455 250 0.50 9.50 | 9,50 | 160,50 IRB2S 36-60 2 3000 6 70 179 200 1.50 3.50 1.50 149.80 IRB3.35 36-60 3.3 2727 9 76 247 200 1.00 2.00 1.50 149.80 IRB5S 36-60 5 2000 10 81 255 125 0.75 1.25 0.50 149.80 IRBS.2S 36-60 5.2 1923 10 81 255 125 0.75 1.25 0.50 149,80 IRB9S 36-60 9 1111 10 83 250 100 0.50 0.75 0.50 149,80 IRB12S 36-60 12 833 10 83 260 75 0.50 0.75 0.25 149,80 IRBi5S 36-60 15 687 10 83 250 75 0.50 0.75 0.25 149.80 IRB24S 36-60 24 417 10 83 260 7 0.50 0.75 0.25 149.80 IRB28S, 36-60 28 357 10 83 260 100 0.50 0.50 0.25 149.80 IRB48S 36-60 48 208 10 84 250 150 0.50 0.50 0.26 149,80 IRBIOGS. 36-60 100 100 190 81 255, 250 0.50 0.50 9,50 187.25 IRC2S 18-60 2 3000 6 70 220 200 1.50 4.00 3.00 160.50 IRC3.3S 18-60 33 2727 3 76 304 200 1.00 2.00 1,60 160.50 IRC5S 18-60 5 2000 10 81 320 125 0.75 1.25 1.00 160.50 IRC5.2S 18-60 5.2 1923 10 81 320 125 0.75 1.26 1.00 160.50 IRC9S 18-60 9 1111 10 83 310 100 0.50 0.75 0.75 160.50 IRC12S 18-60 12 833 10 83 310 75 0.50 0.75 0.50 160.50 IRC15S 18-60 15 687 10 83 310 75 0.50 0.75 0.50 160.50 IRO245 18-60 24 417 10 83 310 75 0.50 0.75 0.50 160.50 IRC28S 18-60 28 357 10 83 310 100 0.50 0.50 0.50 160.50 IRC48S 18-60 48 208 40 a4 305 150 0.50 0.50 0.50 160.50 IRG100 18-60 100 100 10 at 310 250 | 050 | 050 | 075 J 200.63 *Measurements taken with input voltage set at mid value. 10% minimum load required. Ordering Instructions: No minimum. Net 30 days F.0.B. Pelham, New York Series IR-Single Output Gh wn Sonncved tothe Taare (pt a uae te unit allowing for remote shutdown. rT 2.200 I 4 LOAD .500 F lon ok +IN IN TRIM c v I 8 CONTROL (, PIN a e ATE -OUT EXERNAL OUTPUT TRIMMING 1.100 Output can be extemally timmed up by +5% a -IN TRIM *7* TRMUP SRT y, Leel,500 TRIM NOTE: ALL RADIIVE 7/64 URE S01 OM TIM PO ATE AT ETM : . VOLTAGE TO A MAXIMUM OF 5%. 00 NOT GO BEYOND 5% BOTTOM Mew DAMAGE THE MOOULE. ANGE VALUE GOULD Typical Weight: 95 Grams