Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com
MODEL PWR OUTPUT #1 OUTPUT #2 OUTPUT #3 OUTPUT #4
DBX-273-0512 275 +5V @ 50A +12V @ 8/12A pk -12V @ 4A
DBX-274-1205 275 +5V @ 50A +12V @ 8/12A pk -12V @ 4A 5.2V @ 2 A
DBX-274-1224 275 +5V @ 50A +12V @ 8/12A pk -12V @ 4A 24V @ 1.5A
24/28 VDC INPUT – MULTIPLE OUTPUT
MODEL PWR OUTPUT #1 OUTPUT #2 OUTPUT #3 OUTPUT #4
DCT-253-0512 250 +5V @ 30A +12V @ 5A -12V @ 5A
DCT-353-0512 350 +5V @ 45A +12V @ 6A -12V @ 6A
DCX-353-0512 350 +5V @ 50A +12V @ 8/12A pk -12V @ 4A
DCX-354-1205 350 +5V @ 50A +12V @ 8/12A pk -12V @ 4A 5.2V @ 2A
48 VDC INPUT – MULTIPLE OUTPUT
These series are particularly suitable for
critical, “can’t fail”; mobile; or transportable
systems. All models share the same foot-
print and can include current sharing for
redundancy (consult factory for details).
Optional DC power fail, covers, and
fan/cover assemblies are available.
These series are form-fit compatible with
the 9” SC, MAX, MTC, and MPS Series
DCT-250
DBX-275
DCT-350
DCX-350
Featuring:
Over 3 watts/in3power density
Meets international safety
requirements
All outputs regulated ±1%
High peak currents for motor
starting
System air and self-cooling options
Available in dual AC input range
STANDARD DBX SERIES
STANDARD DCT, DCX SERIES
Option F
Option C
250, 275, 350 WATTS
MULTIPLE OUTPUT
24/28 AND 48 VDC INPUT
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com
FUNCTION LOCATION NOTES CONNECTOR
Output #1 Terminal marked +V Main Output
Terminal marked -V Rtn (Common)
Output #2 TB2-3
(If provided) TB2-4 Rtn (Common)
Output #3 TB2-5
(If provided) TB2-4 Rtn (Common)
Output #4 TB2-1 (+) Floating Output
(If provided)) TB2-2 (–) Floating Output
SPECIFICATIONS: ALL MODELS
INPUT
DC Input: DB, DBT, and DBX models 20-32 Vdc range, internally fused for 20 A. DC, DCT,
DCX, and DPS models 40.8-60 Vdc range, internally fused for 15 A.
Efficiency: 70 to 75% typical.
OUTPUT
Adjustability: All outputs user adjustable ±5% minimum.
Line & Load Reg: ±1% over DC input range and 0 to 100% load change, except DPS models
hold ±3% on +5 V output (preprogrammed slope). Multiple output units require a
minimum load of 10% on the +5 V output when drawing full load on the auxiliary outputs.
Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater.
Remote Sense (Output #1):Compensates for 250 mV total line drop. Open sense lead
protection. (See Redundancy, below.)
Temperature Coefficient: 0.02% per degree C.
Stability: 0.1% over 8 hours after 30 minutes warm-up.
Transient Response: Output voltage returns to within 1% in less than 500 µs for a 50% load
change. Peak transient does not exceed 5%.
Overload Protection: All outputs are protected against overload and short circuit. Automatic
recovery upon removal of fault.
Overvoltage Protection (Output #1):Protects load against power supply induced overvoltage.
Trip point is factor y set so that output voltage cannot exceed 136% of nominal.
Peak Output Current: Dual current ratings define continuous and peak currents. The peak
current shown can be delivered for a maximum period of 30 seconds.
Remote Inhibit: Contact closure to the negative sense line drops output power to nominal
zero.
Redundancy (DPS only): External OR-ing diodes and slope program current sharing on
output #1 provide “N+1” capability. Remote sense (+S) compensates for additional 0.6 V
diode voltage drop. Current sharing remains within 10% of the unit’s full output current
rating.
Reverse Voltage: Protected against reverse voltage up to supply current rating.
ENVIRONMENTAL
Thermal Protection: Shuts down power supply if overheated. Automatic recovery.
Temperature Range: to 50°C at full ratings.
Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV
EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive).
Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B.
Cooling: 30 CFM required to achieve full ratings.
Output Isolation: Isolated from ground 50 Vdc, except 100 Vdc for models rated 48 Vdc
output.
250, 275, 350 WATTS
9”x 5”x 2.5”
DCT-250,350, DBX-275, DCX-350
DC OUTPUT
Barrier strip
#6-32 screws
3/8” centers
Bus bars
#10-32 screws
FUNCTION LOCATION NOTES CONNECTOR
J1-1(+ S) Output #1 Sense
J1-2 (– S) Output #1 Sense Rtn
J1-3 Reference to J1-2
Inhibit J1-4 (IH) Short to J1-2
*Optional function
STATUS AND CONTROL
AMP MTA type
#640456-4 pin
header (locking)
Remote Sense
DC Power Good*
FUNCTION –48 Vdc +24 Vdc CONNECTOR
TB1- –48 Vdc Input +24 Vdc Return
TB1- –48 Vdc Return +24 Vdc Input
TB1- Safety Ground Safety Ground
Barrier strip
#6-32 screws
3/8” centers
OPTIONS:
Option “C”, Cover: Limits contact with power supply interior.
Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling
to achieve full ratings at 50°C ambient temperature.
Option “G”, DC Power Good: Provides a TTL “1” open collector when output #1 is above
4.6 V nominal.
Option “V”, Fan/Cover Assembly: Low profile, end venting cover with integral
ball-bearing fan.
Consult factory for other available options.
DC INPUT
DBX, DCT, DCX
with Option F
3.8 lbs - 1.7 kgs
DBX, DCT, DCX
3.2 lbs - 1.5 kgs
Dimensions: Inches
Millimeters
(–)
(+)
( )