Product Data Sheet 614 J/2HHPR-010 The engineer's choice Product Data Sheet 614 J/2HHPR-010 614 J/2HHPR-010 INDEX 1 General ...................................................................................................................................................................... 3 2 Mechanics ................................................................................................................................................................. 3 2.1 2.2 3 Operating Data .......................................................................................................................................................... 4 3.1 3.2 3.3 3.4 3.5 3.6 4 Operating Data - Electrical Interface - Input ...................................................................................................... 4 Electrical Operating Data ................................................................................................................................... 5 Operating Data - Electrical Interface -Output .................................................................................................... 5 Electrical Features ............................................................................................................................................. 6 Aerodynamic ...................................................................................................................................................... 7 Sound Data ........................................................................................................................................................ 7 Environment .............................................................................................................................................................. 8 4.1 4.2 5 General .............................................................................................................................................................. 3 Connections ....................................................................................................................................................... 3 General .............................................................................................................................................................. 8 Climatic requirements*)...................................................................................................................................... 8 Safety ......................................................................................................................................................................... 9 5.1 5.2 Electrical Safety ................................................................................................................................................. 9 Approval Tests ................................................................................................................................................... 9 5/7/2012 page 2 of 10 Product Data Sheet 614 J/2HHPR-010 1 General Fan type Rotational direction looking at rotor Airflow direction Bearing system Mounting position 2 Mechanics 2.1 General Width Height Depth Weight Housing material Impeller material 2.2 Fan clockwise Air outlet over struts Ball bearing any 60,0 mm 60,0 mm 32,0 mm 0,100 kg Plastic Plastic Connections Electrical connection Length of lead wire Wires 400 mm +- 10,0 mm Tolerance Wire gauge (AWG) Insulation diameter Wire 1 Wire 2 Wire 3 Wire 4 24 1,45 mm Colour red blue black white Operation + UB - GND PWM Tacho The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. 5/7/2012 page 3 of 10 Product Data Sheet 614 J/2HHPR-010 3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input PWM Features Inpute type PWM - Frequency Open collector 1 kHz - 30 kHz Typical: 5 kHz Characteristics Schematics 5/7/2012 page 4 of 10 Product Data Sheet 614 J/2HHPR-010 3.2 Electrical Operating Data Measurement conditions: p = 0: I: Normal air density = 1,2 kg/m3; Temperature 23C +/- 3C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).In the intake and outlet area should not be any solid obstruction within 0,5 m. corresp. to free air flow (see section 3.5) corresp. to arithm. mean current value Name PWM 0001 Features Voltage range Nominal voltage Power consumption Tolerance Current consumption Tolerance Speed Tolerance Condition PWM: 95 %; Condition p = 0 p = 0 p = 0 f: 1 kHz Symbol U UN Values 18,0 V 30,0 V P 7,5 W +- 17,5 % 24,0 V 14,2 W +- 25,0 % I 415 mA +- 17,5 % 590 mA +- 25,0 % 490 mA +- 25,0 % n 11.900 1/min +- 12,5 % 15.000 1/min +- 6,0 % 15.000 1/min +- 6,0 % PWM 0001 p = 0 PWM 0001 p = 0 14,7 W +- 25,0 % PWM 0001 Starting current consumption 3.3 f: 30 kHz 2.000 mA Operating Data - Electrical Interface -Output Tacho type Features Tacho operating voltage (UBS) Tacho signal Low Tacho signal High Maximum sink current /2 (Open collector) Note I sink: 2 mA I source: 0 mA 5/7/2012 Values <= 60 V <= 0,4 V <= 60 V <= 20 mA page 5 of 10 Product Data Sheet 614 J/2HHPR-010 External resistor Tacho frequency Tacho isolated from motor Slew rate Alarm type 3.4 External resistor Ra from UBS to US required. All voltages measured to GND. (2 x n) / 60 No => 0,5 V/us None Electrical Features Electronic function Reversed polarity protection Max. residual current at Un Locked rotor protection Locked rotor current at Un Clock signal t3/t4 at locked rotor Speed-Controlled Rectifying diode IF <= 2 mA Auto restart approx. 1.650 mA Typical: 0,3 s / 5,3 s 5/7/2012 page 6 of 10 Product Data Sheet 614 J/2HHPR-010 3.5 Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23C +/- 3C; In the intake and outlet area should not be any solid obstruction within 0,5 m. a.) Operation condition: 15.000 1/min at free air flow PWM 95 %; f: 1 kHz Max. free-air flow (p = 0 / = max.) Max. static pressure (p = max. / =0) 3.6 f: 30 kHz 83,0 m3/h 570 Pa Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see section 3.5 a.) Operation condition: 15.000 1/min at free air flow PWM 95 % PWM min.: ; f: 1 kHz Optimal operating point 75,0 m3/h @ 121 Pa Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 7,6 bel(A) PWM max.:; f: 30 kHz 62,0 dB(A) 5/7/2012 page 7 of 10 Product Data Sheet 614 J/2HHPR-010 4 Environment 4.1 General Min. permitted ambient temperature TU min. Max. permitted ambient temperature TU max. Min. permitted storage temperature TL min. Max. permitted storage temperature TL max. -40 C 78 C -40 C 80 C for start up conditions ambient temperature has to be > -20C 4.2 Climatic requirements*) Humidity requirements Water exposure Radiation exposure Dust requirements Salt fog requirements Harmful gas requirements humid heat, cyclic; according to DIN EN 60068-2-30, 6 cycle None None Dust check; according to DIN EN 60068-2-68, 6g/m2d, 1 day None None *) Permittet application area: The product is for the use in sheltered rooms with limited controlled temperature. Occasionally condensed water is allowed. Direct exposure to water must be avoided. Saline ambient conditions must be avoided. Pollution degree 2 (according DIN EN 60664-1) It occurs only non-conductive pollution. Occassionally, temporary conductivity caused by condensation occurs. 5/7/2012 page 8 of 10 Product Data Sheet 614 J/2HHPR-010 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25C measured with U=500 VDC for 1 min. Air and leakage distances Protection class 5.2 CE UL VDE 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III Approval Tests Yes Yes / UL507, Electric Fans Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment No No CSA CCC The approval tests are observed to: Maximal permitted operating voltage (see section 3.1) and max. permitted ambient temperature TU max. 5/7/2012 page 9 of 10