75W Single Output Industrial DIN RAIL EDR-75 series
File Name:EDR-75-SPEC 2014-08-10



Bauar
Sicher heit
egel gema
t gepru ft
od
be
www.
ID 2000000000
tuv.com
wac g
o s


OUTPUT
INPUT
PROTECTION
SPECIFICATION
75W Single Output Industrial DIN RAIL EDR-75 series
File Name:EDR-75-SPEC 2014-08-10
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.6
FREQUENCY RANGE
EFFICIENCY (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
NOTE
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1200ms, 60ms/230VAC 2000ms, 60ms/115VAC at full load
60ms/230VAC 12ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
47 ~ 63Hz
85.5%
1.45A/115VAC 0.9A/230VAC
29 ~ 33V
87.5%
56 ~ 65V
88.5%
20A/115VAC 35A/230VAC
<1mA / 240VAC
14 ~ 17V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
UL508, TUV EN60950-1 approved
Compliance to EN55022 (CISPR22) Class A, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
-20 ~ +60 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
506.6K hrs min. MIL-HDBK-217F (25)
32*125.2*102mm (W*H*D)
0.51Kg; 28pcs/15.3Kg/1.22CUFT
EDR-75-24 EDR-75-48
24V 48V
3.2A 1.6A
0 ~ 3.2A 0 ~ 1.6A
76.8W 76.8W
120mVp-p 150mVp-p
24 ~ 28V 48 ~ 55V
±1.0% ±1.0%
±0.5% ±0.5%
±1.0% ±1.0%
EDR-75-12
12V
6.3A
0 ~ 6.3A
75.6W
80mVp-p
12 ~ 14V
±2.0%
±0.5%
±1.0%
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH
ENVIRONMENT
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3








105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
TEMP. COEFFICIENT
SAFETY STANDARDS
VIBRATION
MTBF
DIMENSION
OTHERS
PACKING
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY &
EMC
(Note 4)
EMC IMMUNITY
EMC EMISSION
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD (%)
175
LOAD (%)
AMBIENT TEMPERATURE ()
LOAD (%)
-20 0-10 10 20 30 40 45 50 60 70
20
40
50
60
80
100
12V,24V,48V(115VAC)
12V(230VAC)
24V,48V(230VAC)
115VAC
230VAC
(VERTICAL)
fosc : 85KHz
DETECTION
PWM CIRCUIT
O.L.P.
O.T.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING FILTER
&
RECTIFIERS +V
-V
I/P
FG
CONTROL
O.V.P.
&
O.C.P.
75W Single Output Industrial DIN RAIL EDR-75 series
File Name:EDR-75-SPEC 2014-08-10
Derating Curve Static Characteristics
Block Diagram
75W Single Output Industrial DIN RAIL EDR-75 series
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the USER MANUAL on
http://www.meanwell.com/search/EDR-75/EDR_manual.pdf
Mechanical Specification
Installation Instruction
Case No.221B Unit:mm
ADMISSIBLE DIN rail:TS35/7.5 OR TS35/15
(For reference only. Not included with unit.)
102
39
35
234
1
TB1
23
1
TB2
125.2
DC OK
+V ADJ.
Back View
35
Terminal Pin No. Assignment (TB1)
Terminal Pin No. Assignment (TB2)
Pin No.
Pin No.
1
2
1,2
3,4
3
Assignment
Assignment
FG
AC/L or DC +
AC/N or DC -
DC OUTPUT -V
DC OUTPUT+V
Side ViewSide View Front View
Top View
Bottom View
File Name:EDR-75-SPEC 2014-08-10
(48V only)
(12V,24V only)
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
EDR-75-12 EDR-75-48 EDR-75-24