Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES
AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 2
The TE logo, Tyco Electronics and Raychem are trademarks. Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2005-2007 Tyco Electronics Corporation. All rights reserved.
COMPONENT WIRES - FLHT+0311
SPECIFICATION CONTROL DRAWING FLHT+0321
TWO CONDUCTOR CABLE, UNSHIELDED, UNJACKETED, 600 VOLT 10-12-07 D
The complete requirements for procuring the wire described herein shall consist of this document and the issue in effect of
Raychem Specication WCD 3106 and UL Subject 758, Style 3557, File E303150 and carries UL labels to this effect.
TITLE Date Revision
Due to UL limitations on the usage of small strand bare and tin plated conductors, products with conductor strand diameters less than .015" (.381 mm) are intended for dry locations only.
All spool/reel labels shall include " For Dry Locations Only ". For wet locations, other UL Recognized products are available.
The "+" in the part number in the upper right hand corner shall be replaced with a letter designator to dene conductor stranding (see part numbers in tables).
B = 7 Strands C = 19 Strands D = 37 Strands
TABLE I. CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
OUTSIDE DIAMETER
(inch) (mm) NOMINAL
WEIGHT
(lbs/1000 ft.)
(kg/km)
NOMINAL MAXIMUM
FLHTC0321-26-* 26 .063 (1.60) .066 (1.68) 2.59 (3.85)
FLHTC0321-24-* 24 .073 (1.85) .076 (1.93) 3.77 (5.61)
FLHTC0321-22-* 22 .085 (2.16) .088 (2.24) 5.59 (8.32)
FLHTC0321-20-* 20 .101 (2.57) .104 (2.64) 8.51 (12.66)
FLHTC0321-18-* 18 .120 (3.05) .123 (3.12) 12.93 (19.24)
FLHTC0321-16-* 16 .135 (3.43) .139 (3.53) 16.50 (24.55)
FLHTC0321-14-* 14 .164 (4.17) .168 (4.27) 25.48 (37.92)
FLHTD0321-12-* 12 .202 (5.13) .207 (5.26) 39.35 (58.56)
Revision
SPECIFICATION CONTROL DRAWING Page 2 of 2 DFLHT+0321
SCD
TEMPERATURE RATING: 200°C
VOLTAGE RATING: 600 volts (rms) at sea level
INSULATION ELONGATION AND TENSILE STRENGTH:
Elongation, 100% (minimum)
Tensile Strength, 5470 lbf/in2 (minimum)
INSULATION FLAWS:
Spark Test, 6.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak)
PART NUMBER:
The "*" in the part numbers on page 1 shall be replaced by color code designators
with a slash separating the component wire colors.
1/ Example: AWG 16, red and blue component wires: FLHTC0321-16-2/6
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
1/ See footer section on page 1