TYPE
ORDER NO.
Australian type U.K type European type US type Mix four type
AC plug-AU2 AC plug-UK2 AC plug-EU2 AC plug-US2 AC plug-MIX2
Interchangeable AC plug Specifically for GEM18I
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
LOCK
OPEN
LOCK
PUSH
OPEN
PUSH
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
LOCK
OPEN
LOCK
PUSH
OPEN
PUSH
SPECIFICATION
GEM18 seriesI
File Name:GEM18 -SPEC 2015-05-05I
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
LIFE
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V 9V 12V 15V 18V 24V 48V
GEM18 05IGEM18 09IGEM18 12IGEM18 15IGEM18 18IGEM18 24IGEM18 48I
GEM18 05-P1J
IGEM18 09-P1JIGEM18 12-P1JIGEM18 15-P1JIGEM18 18-P1JIGEM18 24-P1JIGEM18 48-P1JI
3A 2A 1.5A 1.2A 1A 0.75A 0.38A
0 ~ 3A 0 ~ 2A
0 ~ 1.5A
0 ~ 1.2A 0 ~ 1A 0 ~ 0.75A
60mVp-p 60mVp-p 80mVp-p 80mVp-p 80mVp-p 80mVp-p 80mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
0.45A / 115VAC 0.25A / 230VAC
30A / 115VAC 60A / 230VAC
ANSI/AAMI ES60601-1 / 60601-1-11, TUV EN60601-1 / 60601-1-11 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:5656VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
3 years : 100% load 40 , 12hours / day℃
400Khrs min. MIL-HDBK-217F(25 )℃
-20 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
75.5*39.1*56.2mm (L*W*H)
140g ; 60pcs / 14kg / CARTON
CONNECTOR
PLUG
CABLE
15W 18W 18W 18W 18W 18W 18W
0 ~ 0.38A
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
Compliance to EN55011 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B
Compliance to EN61000-4,-2,3,4,5,6,8,11, light industry level, criteria A
500ms, 30ms, 16ms/230VAC 500ms, 30ms, 16ms/115VAC at full load
80% 84% 84% 84% 84% 85% 87%
EMC EMISSION
EMC IMMUNITY
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
18WAC-DC High Reliability Interchangeable MedicalAdaptor
Touch current < 100 A/264VAC
μ