30
Hamlin USA Tel: +1 920 648 3000 •Fax:+1 920 648 3001 •Email: sales.us@hamlin.com
Hamlin UK Tel: +44 (0)1379 649700 •Fax:+44 (0)1379 649702 •Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6181 953660 •Fax:+49 (0) 6181 9536666 •Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 4687 0202 •Fax:+33 (0) 1 4686 6786 •Email: sales.fr@hamlin.com
TABLE 2
Cable Type:-
24 AWG 7/32 PVC 105oC
UL1430/UL1569
Standard Lengths
SELECT CABLE
OPTION LENGTH
(in) mm
01 (3,94) 100
02 (11,81) 300
03 (19,69) 500
04 (29,53) 750
05 (39,37) 1000
TABLE 3
Termination Options:-
SELECT DESCRIPTION
OPTION (2 WIRE VERSIONS ILLUSTRATED)
A or F Tinned or untinned leads
B Crimped terminals
C 6.35mm fastons
D AMP MTE 2.54mm pitch
E JST XHP 2.5mm pitch
ACTIVATION
CUSTOMER OPTIONS - Switching Specifications
CUSTOMER OPTIONS - Cable Length and Termination Specification
ORDERING INFORMATION
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURA TE FOR ANY P AR TICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request,HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
59036
Switch Type Table 1
Table 2
Table 3
Sensitivity
Cable Length
Termination
File E61760(N)
www.hamlin.com
X T XX X
DIMENSIONS (in) mm
Series 59085
Features
•Sensor and magnet contained in
single housing
•Sensor operates when ferrous vane
passes through slot
•Normally open,normally closed or
change over options
•Choice of cable length and
connector
Benefits
•Quick and reliable single screw
mounting with location feature
•No standby power requirement
•Hermetically sealed,magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
Applications
•Position and limit sensing
•Security system switch
•Linear actuators
•Industrial process control
•Shaft rotation sensing
59085 Vane Sensor Features and Benefits
59085 Sensor
MUST OPERATE
MUST RELEASE
.285 (7.3)
MAX
Mu METAL
1.0 SQ x .062
VANE
MOVEMENT
59085
ISSUE No:4 DATE: 1/5/3
TABLE 1 Form A Normally Change Normally Normally
Contact Type Open Over Closed Closed H.V.
Switch T ype 13 45
Power Watt - max. 5 5 10 10
Voltage Switching Vdc - max. 175 175 200 300
Breakdown Vdc - min. 200 200 250 450
Current Switching A - max. 0.25 0.25 0.5 0.5
Carry A - max. 1.5 1.5 1.2 1.5
Resistance Contact,Initial Ω- max. 0.2 0.2 0.2 0.2
Insulation Ω- min. 1091091010 1010
Capacitance Contact pF - typ. 0.3 0.3 0.3 0.2
Temperature Operating °C -40 to +105 -40 to +105 -40 to +105 -20 to +105
Storage °C -65 to +105 -65 to +105 -65 to +105 -65 to +105
Time Operate ms - max. 3.0 3.0 1.0 1.0
Release ms - max. 3.0 3.0 1.0 1.0
Shock 11ms 1⁄2 sine G - max. 50 50 100 100
Vibration 50-2000 Hz G - max. 30 30 30 30