7F SERIES 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Features 7F.50.8.xxx.1020 7F.50.8.xxx.2055 7F.50.8.xxx.3100 Filter Fan for electrical cabinets and enclosures 120 V or 230 V AC versions Very low acoustic noise Minimal depth within enclosure * Air volume (14...370) m/h/(8.2...217.8) CFM (with Exhaust Filter installed in cabinet) * Air volume (24...500) m/h (free flow) (14.1...294.3) CFM (free flow) * Power consumption (4...70) W * Operating voltage: 120 or 230 V AC (50/60Hz) * Time-saving installation and maintenance * Further available versions*: - EMC Filter Fan (7F.70) and EMC Exhaust Filter (7F.07) - Filter Fan supplied in Reverse flow mode (7F.80) * * Operating voltage 120, 230 V AC * Air volume 24 m/h (14.1 CFM) * Rated power 13 W * Size 1 * Operating voltage 120, 230 V AC * Air volume 55 m/h (32.4 CFM) * Rated power 22 W * Size 2 * Operating voltage 120, 230 V AC * Air volume 100 m/h (58.9 CFM) * Rated power 22 W * Size 3 * * Product codes, see pages 5 & 8 Note: By reversing the fan motor, the air direction can be changed from "Draw-In" Filter Fan mode to "Exhaust" Filter Fan mode ** (except for the types 7F.50.8.xxx.4370 and 7F.50.8.xxx.5500). ** Supplied in "Draw-In" Filter Fan mode (Standard). Fan data Air volume (free flow) m/h (CFM) 21 55 102 24 (14.1) 55 (32.4) 100 (58.9) 14 (8.2) 40 (23.5) 75 (44.1) 30 43 43 50 000 50 000 50 000 Air volume (with exhaust filter installed) m/h (CFM) Noise level dB (A) Life time at 40C h Electrical data Operating voltage V AC (50/60 Hz) 120 230 120 230 120 230 A 0.14 0.1 0.26 0.14 0.26 0.14 W 13 13 22 22 22 22 Current consumption Rated power Other data Housing, cover Plastics according to UL94 V-0, light gray (RAL 7035) Filter mat (included) EU3 according to DIN 24185, filtering degree (80...90) % Filter material Synthetic fibre with progressive construction, temperature resistant to +100C, VII-2013, www.findernet.com self extinguishing, Class F1 (DIN 53438) Electrical connections / wire size Screw torque 3-pole screw terminals / max. 2.5 mm Nm 0.8 C -10...+70 Ambient temperature range Protection class Protection category according to EN 60529 I IP54 Approvals (according to type) 1 7F SERIES 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Features 7F.50.8.xxx.4230 7F.50.8.xxx.4370 7F.50.8.xxx.5500 Filter Fan for electrical cabinets and enclosures 120 V or 230 V AC versions Very low acoustic noise Minimal depth within enclosure * Air volume (14...370) m/h/(8.2...217.8) CFM (with Exhaust Filter installed in cabinet) * Air volume (24...500) m/h (free flow) (14.1...294.3) CFM (free flow) * Power consumption (4...70) W * Operating voltage: 120 or 230 V AC (50/60Hz) * Time-saving installation and maintenance * Further available versions*: - EMC Filter Fan (7F.70) and EMC Exhaust Filter (7F.07) - Filter Fan supplied in Reverse flow mode (7F.80) * * Operating voltage 120, 230 V AC * Air volume 230 m/h (135.4 CFM) * Rated power 40 W * Size 4 * Operating voltage 120, 230 V AC * Air volume 370 m/h (217.8 CFM) * Rated power 70 W * Size 4 * Operating voltage 120, 230 V AC * Air volume 500 m/h (294.3 CFM) * Rated power 70 W * Size 5 * * Product codes, see pages 5 & 8 Note: By reversing the fan motor, the air direction can be changed from "Draw-In" Filter Fan mode to "Exhaust" Filter Fan mode ** (except for the types 7F.50.8.xxx.4370 and 7F.50.8.xxx.5500). ** Supplied in "Draw-In" Filter Fan mode (Standard). Fan data 200 300 550 m/h (CFM) 230 (135.4) 370 (217.8) 500 (294.3) Air volume (with exhaust filter installed) m/h (CFM) 180 (105.9) 250 (147.1) 370 (217.8) 53 65 65 50 000 50 000 50 000 Air volume (free flow) Noise level dB (A) Life time at 40C h Electrical data Operating voltage V AC (50/60 Hz) 120 230 120 230 120 230 A 0.34 0.17 0.8 0.4 0.8 0.4 40 40 70 70 70 70 Current consumption Rated power W Other data 5 Housing, cover Plastics according to UL94 V-0, light gray (RAL 7035) Filter mat (included) EU3 according to DIN 24185, filtering degree (80...90) % Filter material Synthetic fibre with progressive construction, temperature resistant to +100C, Electrical connections / wire size Screw torque 3-pole screw terminals / max. 2.5 mm Nm 0.8 C -10...+70 Ambient temperature range Protection class Protection category according to EN 60529 Approvals (according to type) 2 I IP54 VII-2013, www.findernet.com self extinguishing, Class F1 (DIN 53438) 7F SERIES 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Features 7F.50.9.024.1020 7F.50.9.024.2055 Filter Fan for electrical cabinets and enclosures 24 V DC versions Very low acoustic noise Minimal depth within enclosure * Air volume (14...180) m/h/(8.2...105.9) CFM (with Exhaust Filter installed in cabinet) * Air volume (24...230) m/h (free low) (14.1...135.4) CFM (free flow) * Power consumption (4...26) W * Operating voltage: 24 V DC * Time-saving installation and maintenance * Further available versions*: - EMC Filter Fan (7F.70) and EMC Exhaust Filter (7F.07) - Filter Fan supplied in Reverse flow mode (7F.80) * * Operating voltage 24 V DC Air volume 24 m/h (14.1 CFM) * Rated power 4 W * Size 1 Operating voltage 24 V DC Air volume 55 m/h (32.4 CFM) * Rated power 9 W * Size 2 * * * * * Product codes, see pages 5 & 8 Note: By reversing the fan motor, the air direction can be changed from "Draw-In" Filter Fan mode to "Exhaust" Filter Fan mode ** (except for the types 7F.50.8.xxx.4370 and 7F.50.8.xxx.5500). ** Supplied in "Draw-In" Filter Fan mode (Standard). Fan data Air volume (free flow) m/h (CFM) Air volume (with exhaust filter installed) m/h (CFM) Noise level dB (A) Life time at 40C h 24 (14.1) 55 (32.4) 14 (8.2) 40 (23.5) 35 45 50 000 50 000 Electrical data Operating voltage V DC Current consumption Rated power 24 24 A 0.16 0.37 W 4 9 Other data Housing, cover Plastics according to UL94 V-0, light gray (RAL 7035) Filter mat (included) EU3 according to DIN 24185, filtering degree (80...90) % Filter material Synthetic fibre with progressive construction, temperature VII-2013, www.findernet.com resistant to 100C, self extinguishing, Class F1 (DIN 53438) Electrical connections / wire size Screw torque 3-pole screw terminals / max. 2.5 mm Nm 0.8 C -10...+70 Ambient temperature range Protection class Protection category according to EN 60529 I IP54 Approvals (according to type) 3 7F SERIES 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Features 7F.50.9.024.3100 7F.50.9.024.4230 Filter Fan for electrical cabinets and enclosures 24 V DC versions Very low acoustic noise Minimal depth within enclosure * Air volume (14...180) m/h/(8.2...105.9) CFM (with Exhaust Filter installed in cabinet) * Air volume (24...230) m/h (free flow) (14.1...135.4) CFM (free flow) * Power consumption (4...26) W * Operating voltage: 24 V DC * Time-saving installation and maintenance * Further available versions*: - EMC Filter Fan (7F.70) and EMC Exhaust Filter (7F.07) - Filter Fan supplied in Reverse flow mode (7F.80) * * Operating voltage 24 V DC Air volume 100 m/h (58.9 CFM) * Rated power 9 W * Size 3 Operating voltage 24 V DC Air volume 230 m/h (135.4 CFM) * Rated power 26 W * Size 4 * * * * * Product codes, see pages 5 & 8 Note: By reversing the fan motor, the air direction can be changed from "Draw-In" Filter Fan mode to "Exhaust" Filter Fan mode ** (except for the types 7F.50.8.xxx.4370 and 7F.50.8.xxx.5500). ** Supplied in "Draw-In" Filter Fan mode (Standard). Fan data Air volume (free flow) m/h (CFM) Air volume (with exhaust filter installed) m/h (CFM) Noise level dB (A) Life time at 40C h 100 (58.9) 230 (135.4) 75 (44.1) 180 (105.9) 45 61 50 000 50 000 Electrical data Operating voltage V DC Current consumption A Rated power W Other data 24 24 0.37 1.08 9 26 Kunststoff nach UL94 V-0, lichtgrau (RAL 7035) Housing, cover Plastics according to UL94 V-0, light gray (RAL 7035) Filter mat (included) EU3 according to DIN 24185, filtering degree(80...90) % Filter material Synthetic fibre with progressive construction, temperature Electrical connections / wire size Screw torque 3-pole screw terminals / max. 2.5 mm Nm 0.8 C -10...+70 Ambient temperature range Protection class Protection category according to EN 60529 Approvals (according to type) 4 I IP54 VII-2013, www.findernet.com resistant to 100C, self extinguishing, Class F1 (DIN 53438) 7F SERIES 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Ordering information Example: Series 7F, Filter Fan for mounting in sidewalls, operating voltage 230 V AC, size 1, air volume 24 m/h. 7 F . 5 0 . 8 . 2 3 0 . 1 0 2 0 Series Type 50 = Filter Fan - for indoor use 70 = EMC Filter Fan - for indoor use 80 = Reverse flow Filter Fan - for indoor use Supply version 8 = AC (50/60 Hz) 9 = DC Operating voltage 024 = 24 V DC 120 = 120 V AC 230 = 230 V AC Enclosure cut-out 1 = Size 1 (92+0.5 x 92+0.5) mm 2 = Size 2 (125+1.0 x 125+1.0) mm 3 = Size 3 (177+1.0 x 177+1.0) mm 4 = Size 4 (224+1.0 x 224+1.0) mm 5 = Size 5 (291+1.0 x 291+1.0) mm Air volume (free flow) 020 = 24 m/h (14.1 CFM) 055 = 55 m/h (32.4 CFM) 100 = 100 m/h (58.9 CFM) 230 = 230 m/h (135.4 CFM) 370 = 370 m/h (217.8 CFM) 500 = 500 m/h (294.3 CFM) Filter Fans - All versions Standard versions EMC versions Reverse flow versions 7F.50.8.120.1020 -- 7F.80.8.120.1020 Filter Fan, Size 1 7F.50.8.120.2055 -- 7F.80.8.120.2055 Filter Fan, Size 2 7F.50.8.120.3100 -- 7F.80.8.120.3100 Filter Fan, Size 3 7F.50.8.120.4230 -- 7F.80.8.120.4230 Filter Fan, Size 4 7F.50.8.120.4370 -- 7F.80.8.120.4370 Filter Fan, Size 4 7F.50.8.120.5500 -- 7F.80.8.120.5500 Filter Fan, Size 5 7F.50.8.230.1020 7F.70.8.230.1020 7F.80.8.230.1020 Filter Fan, Size 1 7F.50.8.230.2055 7F.70.8.230.2055 7F.80.8.230.2055 Filter Fan, Size 2 7F.50.8.230.3100 7F.70.8.230.3100 7F.80.8.230.3100 Filter Fan, Size 3 7F.50.8.230.4230 7F.70.8.230.4230 7F.80.8.230.4230 Filter Fan, Size 4 7F.50.8.230.4370 7F.70.8.230.4370 7F.80.8.230.4370 Filter Fan, Size 4 7F.50.8.230.5500 7F.70.8.230.5500 7F.80.8.230.5500 Filter Fan, Size 5 7F.50.9.024.1020 7F.70.9.024.1020 7F.80.9.024.1020 Filter Fan, Size 1 7F.50.9.024.2055 7F.70.9.024.2055 7F.80.9.024.2055 Filter Fan, Size 2 7F.50.9.024.3100 7F.70.9.024.3100 7F.80.9.024.3100 Filter Fan, Size 3 7F.50.9.024.4230 7F.70.9.024.4230 7F.80.9.024.4230 Filter Fan, Size 4 VII-2013, www.findernet.com Note: The technical features (air volume, dimensions and electrical parameters) for the Standard Filter Fans (7F.50), the EMC Filter Fans (7F.70) and the Reverse flow versions (7F.80) - are exactly the same. 5 7F SERIES 7F Series - Exhaust Filter Features 7F.05.0.000.1000 7F.05.0.000.2000 7F.05.0.000.3000 Exhaust Filter The size of the Exhaust Filter should match the size of the Filter Fan to achieve the best ventilation within the cabinet Minimum depth within enclosure Time-saving installation and maintenance * Further available versions*: - EMC Exhaust Filters (7F.07) * * * Product codes, see page 8 For Filter Fans 7F.50.x.xxx.1020 * Size 1 * For Filter Fans 7F.50.x.xxx.2055 * Size 2 * For Filter Fans 7F.50.x.xxx.3100 * Size 3 * Other data Housing, Cover Filter mat (included) Filter material Plastics according to UL94 V-0, light gray (RAL 7035) EU3 according to DIN 24185, filtering degree (80...90) % Synthetic fibre with progressive construction, temperature resistant to +100C, self extingiushing, Class F1 (DIN 53438) Protection category according to EN 60529 IP54 VII-2013, www.findernet.com Approvals (according to type) 6 7F SERIES 7F Series - Exhaust Filter Features 7F.05.0.000.4000 7F.05.0.000.5000 Exhaust Filter The size of the Exhaust Filter should match the size of the Filter Fan to achieve the best ventilation within the cabinet Minimum depth within enclosure Time-saving installation and maintenance * Further available versions*: - EMC Exhaust Filters (7F.07) * * * Product codes, see page 8 For Filter Fans 7F.50.x.xxx.4230 or 7F.50.8.xxx.4370 * Size 4 * For Filter Fans 7F.50.8.xxx.5500 * Size 5 * Other data Housing, Cover Filter mat (included) Filter material Plastics according to UL94 V-0, light gray (RAL 7035) EU3 according to DIN 24185, filtering degree (80...90) % Synthetic fibre with progressive construction, temperature resistant to +100C, self extingiushing, Class F1 (DIN 53438) Protection category according to EN 60529 IP54 VII-2013, www.findernet.com Approvals (according to type) 7 7F SERIES 7F Series - Exhaust Filter Ordering information Example: Series 7F, Exhaust Filter for mounting in sidewalls, size 1. 7 F . 0 5 . 0 . 0 0 0 . 1 0 0 0 Series Type 05 = Exhaust Filter - for indoor use 07 = EMC Exhaust Filter - for indoor use Supply version 0 = Not applicable for Exhaust Filter Operating voltage 000 = Not applicable for Exhaust Filter Enclosure cut-out 1000 = Size 1 (92+0.5 x 92+0.5) mm 2000 = Size 2 (125+1.0 x 125+1.0) mm 3000 = Size 3 (177+1.0 x 177+1.0) mm 4000 = Size 4 (224+1.0 x 224+1.0) mm 5000 = Size 5 (291+1.0 x 291+1.0) mm Components Exhaust Filter - All versions Standard-versions EMC - versions 7F.05.0.000.1000 7F.07.0.000.1000 Exhaust Filter, Size 1 7F.05.0.000.2000 7F.07.0.000.2000 Exhaust Filter, Size 2 7F.05.0.000.3000 7F.07.0.000.3000 Exhaust Filter, Size 3 7F.05.0.000.4000 7F.07.0.000.4000 Exhaust Filter, Size 4 7F.05.0.000.5000 7F.07.0.000.5000 Exhaust Filter, Size 5 Standard-Filter Fan Standard-Exhaust Filter EMC-Filter Fan EMC-Exhaust Filter Filter mat 7F.50.8.xxx.1020 7F.05.0.000.1000 7F.70.8.xxx.1020 7F.07.0.000.1000 07F.15 1 7F.50.8.xxx.2055 7F.05.0.000.2000 7F.70.8.xxx.2055 7F.07.0.000.2000 07F.25 2 7F.50.8.xxx.3100 7F.05.0.000.3000 7F.70.8.xxx.3100 7F.07.0.000.3000 07F.35 3 7F.50.8.xxx.4230 7F.05.0.000.4000 7F.70.8.xxx.4230 7F.07.0.000.4000 07F.45 4 7F.50.8.xxx.4370 7F.05.0.000.4000 7F.70.8.xxx.4370 7F.07.0.000.4000 07F.45 4 7F.50.8.xxx.5500 7F.05.0.000.5000 7F.70.8.xxx.5500 7F.07.0.000.5000 07F.55 5 7F.50.9.024.1020 7F.05.0.000.1000 7F.70.9.024.1020 7F.07.0.000.1000 07F.15 1 7F.50.9.024.2055 7F.05.0.000.2000 7F.70.9.024.2055 7F.70.0.000.2000 07F.25 2 7F.50.9.024.3100 7F.05.0.000.3000 7F.70.9.024.3100 7F.70.0.000.3000 07F.35 3 7F.50.9.024.4230 7F.05.0.000.4000 7F.70 9 024 4230 7F.70.0.000.4000 07F.45 4 07F.25 07F.45 07F.55 Spare Filter mats 07F.15 Protection category Accessories Size IP54 Pressure compensation device, for pressure compensation in closed cabinets or enclosures Air interface area cm Mounting Torque Nm 7 5 (max. 10) plastic according to UL94-V0 mm Mounting position Ambient temperature 07F.80 PG 29 thread with union nut Material Dimensions (diameter / depth) 07F.35 65.5 / 30.5 upper part of cabinet sidewalls C Protection category -45...+70 IP55 Unit package contains 2 pressure compensation devices 8 VII-2013, www.findernet.com 07F.80 7F SERIES 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Mounting instructions for Filter Fans and Exhaust Filters Mounting arrangement of Filter Fans and Exhaust Filters Filter Fan Drilling template and mounting cut-outs for Filter Fans and Exhaust Filter Size 1 Size 2 Size 3 Size 4 Size 5 VII-2013, www.findernet.com Mounting and maintenance 1. Make the panel cut-out according to the size of the Filter Fan or Exhaust Filter in the sidewall of the cabinet as appropriate. A template of the panel cut-out is included in the packaging of the Filter Fan or Exhaust Filter. 2. Make the electrical connection. 3. Mount by simply snapping the side-located lugs on the Filter Fan or Exhaust Filter into the panel cut-out (without using screws for sidewall thickness of 1,2...2,4 mm). At other thickness it is recommended to mount the Filter Fan by the screws supplied (for size 1, the template shows the mounting cut-out only). 4. When screws are needed for the mounting, remove the plastic cover and fix the Filter Fan with the 4 screws supplied. Then insert the filter mat and snap the plastic cover to the mounting frame. 5. During maintenance or when replacing the filter mat remove the plastic cover, replace the filter mat and snap on the plastic cover. 9 SERIE 7F 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Fan selection Power dissipation (W) Temperature difference ( C) between the inside and the outside of the cabinet Air Flow (m3/h) 24 m3/h 55 m3/h 100 m3/h 230 m3/h 370 m3/h 500 m3/h VII-2013, www.findernet.com Example: First, estimate the power dissipated within the cabinet. Then calculate the maximum difference between the internal and external temperature (green lines) by considering the difference between the maximum permitted internal temperature (as dictated by the temperature rating of the enclosed components, or specification) and the maximum temperature expected outside the cabinet. The projection onto the X axis, of the intersection between the power (watts) and the appropriate green line, corresponds to the air flow rate in m3/h required to meet the maximum internal temperature limit. Extending this line vertically to intersect with the blue horizontal lines, indicates the most appropriate model of 7F fan to be fitted to the cabinet to provide the requisite air flow. The example above considers a cabinet with an internal thermal power dissipation of 500 W, and assumes the maximum temperature difference between the inside and the outside of the cabinet to be 20 C. The required air flow can be seen to be a little less than 80 m3/h. It is suggested that this is increased by 10% to allow for the affects of a dirty filter. And so, it can be seen that models of the 7F with100 m3 / h flow rate will provide the proper dissipation of heat under these circumstances. 10 7F SERIES 7F Series - Filter Fan (24...500) m/h (14.1...294.3) CFM Application notes Filter Fan The ball-bearing axial fan housing is made of aluminium and the rotor is made of plastic or metal (depending on the type). Filter classes Within DIN 24185 are specified 9 filter classes, categorised into 4 coarse dust filters und 5 fine dust filters. The coarse dust filters (EU1 - EU4) are able to filter particles > 10 m and the fine dust filters (EU5 - EU9) are able to filter particles from (1...10) m. Filter classes Example of particle Particle size EU1 - EU4 Textile fibers, hair, sand, pollen, spores, insects, cement dust > 10 m EU5 - EU9 Pollen, spores, cement dust, tobacco smoke, oil smoke, soot (1...10) m Mounting of the pressure compensation device In sealed cabinets and enclosures the internal pressure can vary due to changes in temperature. The pressure compensation device (07F.80) will relieve this internal/external pressure differential whilst maintaining a high level of protection - preventing the ingress of dust and moisture into the cabinet or the enclosure. The pressure compensation device is approved for use in cabinets and enclosures according to DIN EN 62208. Drill a hole O 37+1.0 mm in the housing wall and fix the pressure compensation device with the accompanying nut. It is important to ensure that the sealing ring is located on the outside. To ensure optimum pressure balance, it is recommended to fit 2 pressure compansation device at the upper sides of the cabinet or enclosure. Filtering degree (Am) The degree of filtering (Am) is the percentages of dust, by weight, that is caught and retained by the filter. Filter mats The quality of these filters mats has been independently tested, according DIN 24185 and branded after passing the test. The filter mats are to filter class EU3 and have an average filtering degree of (80...90) %. Filter material The filter material consists of a synthetic fiber with progressive construction which is moisture-resistant to 100 % RH and temperature resistant to +100C. According to the strict requirements of fire class F1, DIN 53438, these filter mats are self extinguishing. Progressive construction at filter mats The individual fibers of these filter mats are bonded by a special process to provide a progressive construction where the fiber size and spacing varies through the thickness of the filter mat. This means that coarse dust particles are caught early and fine dust later through the thickness of the mat. In this way the entire depth of the filter mat is used. Flammability class of the housing and the cover The plastic materials used comply with flammability class V-0, according UL94. EMC Filter Fans and EMC Exhaust Filters The plastic mounting frame of the EMC Filter Fans (7F.70) and EMC Exhaust Filters (7F.07) are sprayed with a conductive (metallic) paint. The gasket located on the mounting frame, for sealing the Filter Fan or Exhaust Filter in the cabinet is also metalised. In addition; located at the EMC Filter Fan between the metalized mounting frame and the filter mat, is a metal grid. Therefore, between the metal parts of the Filter Fan and the metal cabinet, there is a conductive connection. VII-2013, www.findernet.com Filter Fan in "reverse flow" version As supplied, the standard Filter Fan is in "Draw-In"- mode, which means that cool air is filtered and drawn into the cabinet. In some cases it may be required that the warm air is blown out of the cabinet. In which case it is possible to get Filter Fans in "Exhaust Filter" mode version (7F.80). 11