UNIVERSAL INPUT POWER FACT OR CORRECTION AC-DC
SINGLE & MULTIPLE OUTPUT 100 WATT S 19” COMPATIBLE
SWITCHING POWER SUPPLIES APS100PU SERIES EUROCARD
FOR VMEbus SYSTEM
Advanced Power Solutions
FEATURES:
! ACCOMMODATES UNIVERSAL AC SOURCES
! MEETS IEC1000-3-2 HARMONIC CORRECTION
! MEETS UNIVERSAL SAFETY STANDARDS
! 19” COMPATIBLE EUROCARD FORMAT
! EMI MEETS EN 55022 AND FCC CLASS B
! CE MARKING COMPLIANCE
! 10HP X 3U X 160MM VMEbus STANDARD
GENERAL SPECIFICATION
Efficiency: Typ. 73-76%
Switching Frequency: Fixed frequency 80KHz
Circuit Topology: Fixed frequency forward circuit
Transient Response: Output voltage returns in
less than 3mS following
a 25% load change
Safety Standard: IEC950/UL1950 Class I
Operating Temperature: 0 to +50°C full load &
+50 to +70°C by de-rating 2%/°C
Storage Temperature: -25 to +85°C
Temperature Coefficient: Typ. 0.03% /°C
Cooling: Free air convection cooling
Construction format: Enclosure metal box format
Power Density: 2.0 Watts / Cubic Inch
Note: All measurements are at nominal input, full load, and +25• unless otherwise specified.
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC
Input Connector: DIN 41612 at rear
Input Frequency: 47-63Hz
Inrush Current: 32A peak @ 230Vac
Input Current: 1.0A @ 115Vac,0.5A @ 230Vac
Dielectric Withstand: Meets IEC950
EMI: Meet EN 55022 B. & FCC B
Power Factor Correction: Meets Harmonic Correction
IEC1000-3-2 .PF typ.0.97-0.98
Power Indicator: Green LED
Power OK Signal: Installed
Logic Inhibit: Installed
Hold-up Time: 20mS @ 115Vac & 230Vac
Earth Leakage: Less than 0.40mA @ 230Vac
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart
Output Current: See Ratings Chart
Output Connector: DIN 41612 at rear
Line Regulation: Typ. 0.5%
Load Regulation: Main VO1 typ. ±1-2.0%
Aux.VO2 typ. ±2.0% (Mag. Amp.)
Aux.VO3 typ. ±3.0% (P.R.)
Noise & Ripple: Typ. 1% peak to peak
OVP: Built-in at main VO1
Adjustability: Available at VO1 & VO2
Overload Protection (OLP): Fully protected against
output overload and short circuit
Consult the factory for OLP setting