Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices New TWND Series -- Full Size NEMA Pushbuttons Signaling Lights Relays & Sockets New! TWND Series: Heavy duty switches built to last Key features: * Variety of button sizes up to 2 9/16" (65mm) * LED illumination With button sizes up to 2 9/16" (65mm), chrome plated zinc locking rings, die cast zinc mounting threads, steel anti-rotation rings, and self cleaning contacts, the TWNDs are here to stay. The TWND series also offers LED illumination in full voltage and transformer models. * Transformer or full voltage * Slow make, double break wiping contacts Timers * Rugged construction includes chrome plated zinc locking ring die cast zinc mounting thread The rugged series of TWND switches offers both variety and durability in an attractive design. Regardless of your switching needs, the NEW TWND series provides the kind of long lasting, industrial strength quality you've come to expect from IDEC. * Modular construction for maximum flexibility * Available assembled or as sub-components File No. LR21451 R 50363567 Terminal Blocks UL Listed File No. E68961 Contactors * UL Type 4X, 13 and IP65 watertight/oiltight panel Certificate No. 2016010305902410 Circuit Breakers 1904041136 800-262-IDEC (4332) * USA & Canada 745 Switches & Pilot Devices Relays & Sockets Signaling Lights Switches & Pilot Devices o30mm - TWND Series Specifications Conforming to Standards EN60947-5-1, UL508, CSA C22-2 No.14 Approvals CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TUV: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Operating Temperature Operation: -25 to +50C (illuminated versions) -25 ~ +70C non-illuminated Storage: -40 to +80C (without freezing) C-> C Vibration Resistance 5 to 55Hz, 98m/sec2 (10g) conforming to IEC60068-2-6 Shock Resistance 980m/sec2 (100g) conforming to IEC60068-2-27 Electric Shock Protection Class 2 conforming to IEC60664-1 Degree of Protection IP65 (from front of the panel) (conforming to IEC60529) UL Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS6-110) Mechanical Life Momentary pushbuttons: 5,000,000 (1800 operations per hour) All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 Mechanical-Electrical Specifications Rated Operational Characteristics Rated Insulation Voltage Rated Impulse Withstanding Voltage oDielectric Strength Rated Thermal Current Minimum Switching Capacity Contact Operation Timers Operating Force AC-15: A600 600V Between live and dead metal parts 2.5kV AC, 1 minute 10 Amp 5 mA at 3V AC/DC (applicable range may vary with operating conditions and load types) Slow break NC or NO Flush and extended pushbuttons--with 1NO or 1NC contact: 6.22N (momentary), 9.01.5N Additional contacts--1NO or 1NC: +3.0N Unit Recommended Terminal Torque HW-U Contact Block Contactors Illuminated Unit (*1) Applicable Wire Size Pilot Light 2 1.0 to 1.3 M3.5 Number of Wires Crimping Terminal o0.5 to 1.6 mm (AWG14 to 22) Solid Wire o1.7 to 2.0 mm (AWG12) 0.3 to 2.0 mm2 (AWG14 to 22) Stranded Wire 2.1 to 3.5 mm2 (AWG12) Crimping Terminal Solid Wire o0.5 to 1.6 mm (AWG14 to 22) Stranded Wire 0.3 to 2.0 mm (AWG14 to 22) Crimping Terminal Solid Wire o0.5 to 1.6 mm (AWG14 to 22) Stranded Wire o0.3 to 2.0 mm (AWG14 to 22) M3.5 0.6 to 1.0 (M3.0) 2 1.0 to 1.3 (M3.5) 1. * refers to the lamp terminals of the illuminated push buttons and selector switches. Contact Resistance Initial contact resistance of 50m or less 4mm (NO and NC) 2mm (NO-EM and NC-LB) LEDs: 6V: 8mA, 12V: 11mA, 24V: 11mA, 120V: 8.8mA, 240V: 8.6mA Silver Contact Gap Terminal Blocks Terminal Screw 2 2 1 2 1 Recommended Tightening Torque (Nm) 1.0 to 1.3 1.0 to 1.3 1.2 to 1.3 1.0 to 1.3 1.2 to 1.3 Wire LED Ratings Contact Material Contact Ratings AC-15 (A600) Contact Ratings by Utilization Category IEC 60947-5-1 DC-13 (P600) Contact Ratings by Utilization Category Operational Voltage Circuit Breakers AC 50/60 Hz Operation Current DC 746 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads & solid state loads 10A -- 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A -- 7A 5A 3A 1A DC-12 Control of resistive loads & solid state loads 10A 5A -- 2.2A 1.1A -- DC-13 Control of electromagnets 5A 2A -- 1.1A 0.6A -- www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) Signaling Lights Relays & Sockets Assembled Pushbuttons A B ( ) D 1 10 NU R Function Button Color B: O: V: Y: B: Black R: Red Momentary Maintained Pushlock Turn Reset Push-Pull G: Green S: Blue W: White Y: Yellow Contact Arrangement Blank: Octagonal F: Full Shroud G: Mushroom Shroud P: Neoprene Boot Timers 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Bezel Shape Button Shape Series Designation D: TWND Series Flush Extended Mushroom o 40mm Jumbo Mushroom o 65mm Contactors 1: 2: 3: 4: 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. Terminal Blocks Circuit Breakers 1904041136 800-262-IDEC (4332) * USA & Canada 747 Switches & Pilot Devices Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o30mm - TWND Series Non-Illuminated Pushbuttons (Assembled) Non-Illuminated Pushbuttons Style j Button Color Codes Contacts Momentary Maintained 1NO 1NC 1NO-1NC 2NO 2NC ABD110NUj ABD101NUj ABD111NUj ABD120NUj ABD102NUj AOD110NUj AOD101NUj AOD111NUj AOD120NUj AOD102NUj 1NO 1NC 1NO-1NC 2NO 2NC ABD210NUj ABD201NUj ABD211NUj ABD220NUj ABD202NUj AOD210NUj AOD201NUj AOD211NUj AOD220NUj AOD202NUj Extended with Neoprene Boot 1NO 1NC 1NO-1NC 2NO 2NC ABPD210NUj ABPD201NUj ABPD211NUj ABPD220NUj ABPD202NUj AOPD210NUj AOPD201NUj AOPD211NUj AOPD220NUj AOPD202NUj Recessed 1NO 1NC 1NO-1NC 2NO 2NC ABFD110NUj ABFD101NUj ABFD111NUj ABFD120NUj ABFD102NUj AOFD110NUj AOFD101NUj AOFD111NUj AOFD120NUj AOFD102NUj Extended with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFD210NUj ABFD201NUj ABFD211NUj ABFD220NUj ABFD202NUj AOFD210NUj AOFD201NUj AOFD211NUj AOFD220NUj AOFD202NUj o 40mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABD310NUj ABD301NUj ABD311NUj ABD320NUj ABD302NUj AOD310NUj AOD301NUj AOD311NUj AOD320NUj AOD302NUj o 40mm Mushroom Head with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGD310NUj ABGD301NUj ABGD311NUj ABGD320NUj ABGD302NUj AOGD310NUj AOGD301NUj AOGD311NUj AOGD320NUj AOGD302NUj o 65mm Jumbo Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABD410NUj ABD401NUj ABD411NUj ABD420NUj ABD402NUj AOD410NUj AOD401NUj AOD411NUj AOD420NUj AOD402NUj o 65mm Jumbo Mushroom Head with Shallow Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGD410NUj ABGD401NUj ABGD411NUj ABGD420NUj ABGD402NUj AOGD410NUj AOGD401NUj AOGD411NUj AOGD420NUj AOGD402NUj o 65mm Jumbo Mushroom Head With Deep Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFD410NUj ABFD401NUj ABFD411NUj ABFD420NUj ABFD402NUj AOFD410NUj AOFD401NUj AOFD411NUj AOFD420NUj AOFD402NUj Flush Extended Color Code Black B Green G Red R Blue S Yellow Y White W 1. 65mm Jumbo mushroom not available in white. 2. Neoprene boot is not available in blue or white. 1. In place of j, specify the Button Color Code. 2. For sub-assembly part numbers, see next page. 4. Neoprene boot available only in Black (B), Green (G), Red (R) and Yellow (Y). 748 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Non-Illuminated Pushbuttons (Sub-Assembled) Contact Block + Operator Part Number Momentary Maintained ABD1200T8 AOD1200T8 Complete Part AOLFD2300T8 o 40mm Mushroom/o 65mm Jumbo Mushroom ABD3400T8 AOD3400T8 ABGD-300T AOGD-300T Part Number Flush ABD1BN-j Extended ABD2BN-j o 40mm Mushroom ABD3BN-j o 65mm Jumbo Mushroom ABD4BN-j Timers ALFD2300T8 Style Relays & Sockets Extended with Full Shroud o 40mm Mushroom with Full Shroud = Buttons and Lenses Style Flush/Extended Button Signaling Lights Operators + Contactors In place of j, specify the Button Color Code. (See table previous page) o 65mm Jumbo Mushroom with Shallow Shroud ABGD-400T AOGD-400T Contact Blocks o 65mm Jumbo Mushroom with Deep Shroud ABFD-400T AOFD-400T All Control Units 1NC HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) HW-DB Circuit Breakers Dummy Block Part Number 1NO Terminal Blocks Style 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining HW-U10R-F and HW-U01R-F result in overlapping contacts (remain on, or closed, when switch is moved between two positions). 1904041136 800-262-IDEC (4332) * USA & Canada 749 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Signaling Lights Stop Switches (Assembled) Relays & Sockets Assembled Stop Switches A V (L) D 3 22 11 Timers NU R Function Button/Lens Color Code V:Pushlock Turn Reset Y:Push-Pull A: Amber G: Green R: Red S: Blue W: White Y: Yellow Illumination Blank: None L: Illuminated (illuminated units only) Series Designation D: LED D: TWND Series Contact Arrangement Button/Lens Size 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC 3: 40mm Mushroom Contactors D Illumination Circuit Full Voltage: 66: 6VAC/DC 11: 12VAC/DC 22: 24AC/DC Terminal Blocks QH2: 120VAC QM4: 240VAC Transformer: 126: 120VAC step down transformer 246: 240VAC step down transformer Circuit Breakers 486: 480VAC step down transformer 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. 750 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Stop Switches (Assembled) Stop Switches j Button Color Codes Style Contacts Part Number o 40mm Pushlock Turn Reset 1NO-1NC 2NO 2NC AVLD3l11DNUR* AVLD3l20DNUR* AVLD3l02DNUR* Transformer 1NO-1NC 2NO 2NC AVLD3 m 11DNUR* AVLD3 m 20DNUR* AVLD3 m 02DNUR* Non-Illuminated 1NO 1NC 1NO-1NC 2NO 2NC AYD310NUj AYD301NUj AYD311NUj AYD320NUj AYD302NUj Non-Illuminated o 40mm Illuminated Pushlock Turn Reset Full Voltage o 40mm Push-Pull o 40mm Illuminated Push-Pull Full Voltage 1NO-1NC 2NO 2NC AYLD3 m 11DNUk ** AYLD3 m 20DNUk ** AYLD3 m 02DNUk ** In place of j, specify the button color code In place of k, specify the lens color code. In place of l, specify the Full Voltage (lamp voltage) Code. * Only available in red. In place of m, specify the transformer voltage code. **Not available in blue. For sub-assembly part numbers, see next page. For nameplates and accessories, see page 769 and page 767. For dimensions, see page 772. G Red R Blue S Yellow Y k Lens Color Codes Color Code Amber Green Red Blue White Yellow A G R S W Y l Full Voltage Codes Voltage Code 6V AC/DC 66 12V AC/DC 11 24V AC/DC 22 120V AC QH2 240V AC QM4 m Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 Transformers step down to 6V. Contactors 1. 2. 3. 4. 5. 6. 7. 8. 9. AYLD3l11DNUk ** AYLD3l20DNUk ** AYLD3l02DNUk ** Green Timers Transformer 1NO-1NC 2NO 2NC B Relays & Sockets AVD310NUR* AVD301NUR* AVD311NUR* AVD320NUR* AVD302NUR* Code Black Signaling Lights 1NO 1NC 1NO-1NC 2NO 2NC Color Terminal Blocks Circuit Breakers 1904041136 800-262-IDEC (4332) * USA & Canada 751 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Stop Switches (Sub-Assembled) Transformer* + Operator + Lamp + Button/Lens = Complete Part * Not required for full voltage units. Relays & Sockets Signaling Lights Operators Lamps Style Style Part Number Voltage 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC LED o40mm Illuminated and Non-illuminated Pushlock Turn Reset AVD000T8 o 40mm Illuminated and Non-illuminated Push-Pull Part Number LSTD-6l LSTD-1l LSTD-2l LSTD-H2l LSTD-M4l 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. AYD000T8 j Button Color Codes Buttons and Lenses Style Part Number Button for Pushlock Turn Reset Stop Switches (o40mm, red only) Timers k Lens Color Codes AVN3B-R Color Code Black Green Red Blue Yellow B G R S Y Color Code Amber Green Red Blue White A G R S W l LED Color Codes Color Code Amber Green Red Blue White A G R S W Contact Blocks Lens for Illuminated Pushlock Turn Reset Stop Switches (o40mm, red only) AVLN3LU-R Part Number 1NO 1NC Style All Control Units Button for Push-Pull Stop Switches (o40mm) AYD3BN-j HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Contactors Dummy Block Lens for Illuminated Push-Pull Stop Switches (o40mm) 2 pos* AYLD3L-k HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining HW-U10R-F and HW-U01R-F result in overlapping contacts. Transformers 1. In place of j, specify the Button Color Code. (See table below) 2. In place of k, specify the LED Color Code. 3. *Not available in blue. Style Primary Voltage (50/60Hz) Part Number 120V AC TW-F126B 240V AC TW-F246B 480V AC HW-L486 Terminal Blocks Lamp Circuit Components Style Long Lamp Holder Application Used with Full-size Transformer and two contact blocks Used with Full Voltage Adaptor and two contact blocks Circuit Breakers Lead Holder Used with TW-LH2 holder when using four contact blocks Part Number 6V secondary voltage (uses 6V LED). TW-LH2 Full Voltage Modules Style HW-LH3 Dummy Block with Full Voltage Adaptor Full Voltage Adaptor Description For use with odd number of contacts. Finger-Safe For use with even number Finger-Safe of contacts. Part Number HW-DA1FBN TW-DA1FB All Transformers step down to 6V (use 6V lamp). 752 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Pilot Lights (Assembled) Signaling Lights Assembled Pilot Lights A P: D 1 126 D NU R Lens Color Code Pilot Light A: G: R: S: W: Y: Series Designation D: TWND Series Lens Shape 1: Dome Relays & Sockets Function P Amber Green Red Blue White Yellow D: LED Rated Operational Voltage (Primary) Full Voltage Type 66: 6VAC/DC 11: 12VAC/DC 22: 24VAC/DC QH2: 120VAC QM4: 240VAC Timers Transformer Type 126: 120V AC 246: 240V AC 486: 480V AC Contactors Use only when interpreting part numbers. Do not use for developing part numbers. LED Pilot Lights Style k Lens Color Codes Operating Voltage Part Number Color Code LED Amber A Green G Transformer Dome APD1126DNUk APD1246DNUk APD1486DNUk R S White W Yellow Y l Full Voltage Codes Full Voltage Dome -- APD1lDNUk Voltage Code 6V AC/DC 66 12V AC/DC 11 24V AC/DC 22 120V AC QH2 240V AC QM4 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. In place of k, specify the Lens/LED Color Code. 2. In place of l, specify the Full Voltage Code (LED voltage). 3. Yellow pilot light comes with white LED. 1904041136 Red Blue Terminal Blocks 120V AC 240V AC 480V AC 753 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Pilot Lights (Sub-Assembled) Transformer* + Operator + Lamp + Lens = Complete Part Signaling Lights * Not required for full voltage units. One Each from Left Column Operators Part Number Transformer or FULL Voltage Primary Voltage (50/60Hz) Part Number APD-F APD09ST8 Required for all full voltage models. Two pieces each. 2 clips required for full voltage pilot lights Transformers (only for Pilot Lights) Lenses Style Style Timers One Selection from Right Column Full Voltage Clips Style Relays & Sockets plus Primary Voltage (50/60Hz) Part Number LED Dome Lens Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 APN106LN-k 6V secondary voltage (use 6V lamp). Contactors 1. In place of k, specify the Lens Color Code. Style LED Voltage Part Number 6V AC/DC LSTD-6l 12V AC/DC LSTD-1l 24V AC/DC LSTD-2l 120V AC LSTD-H2l 240V AC LSTD-M4l l LED Color Codes Color Code Color Code Amber Green Red Blue White Yellow A G R S W Y Amber Green Red Blue White A G R S W Yellow LED not available, use white LED with Yellow lens. 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Circuit Breakers Terminal Blocks k Lens Color Codes Lamps 754 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Illuminated Pushbuttons (Assembled) Signaling Lights Relays & Sockets Assembled Illuminated Pushbuttons A L ( ) D 2 126 11 D NU R Lens Color Code L: Momentary Action OL: Maintained Action A: Amber G: Green R: Red S: Blue W: White Y: Yellow Bezel Shape Blank: Octagonal F: Full Shroud Series Designation Timers Function D: LED D: TWND Series Contact Arrangement Lens Shape 2: Extended 3: Mushroom o 40mm Contactors 20: 2NO 02: 2NC 11: 1NO-1NC Rated Operational Voltage (Primary) Full Voltage Type 66: 6VAC/DC 11: 12VAC/DC 22: 24VAC/DC QH2: 120VAC QM4: 240VAC Terminal Blocks Transformer Type 126: 120V AC 246: 240V AC 486: 480V AC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V. Circuit Breakers 1904041136 800-262-IDEC (4332) * USA & Canada 755 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Illuminated Pushbuttons (Assembled) Illuminated Pushbuttons k Lens Color Codes Style Contacts Extended Lens Signaling Lights Full Voltage 1NO-1NC 2NO 2NC Part Number Momentary Maintained ALD2l11DNUk ALD2l20DNUk ALD2l02DNUk AOLD2l11DNUk AOLD2l20DNUk AOLD2l02DNUk Color Code Amber Green Red Blue White Yellow A G R S W Y l Full Voltage Codes Transformer 1NO-1NC 2NO 2NC ALD2 m 11DNUk ALD2 m 20DNUk ALD2 m 02DNUk AOLD2 m 11DNUk AOLD2 m 20DNUk AOLD2 m 02DNUk Full Voltage 1NO-1NC 2NO 2NC ALFD2l11DNUk ALFD2l20DNUk ALFD2l02DNUk AOLFD2l11DNUk AOLFD2l20DNUk AOLFD2l02DNUk Relays & Sockets Extended Lens with Full Shroud Transformer 1NO-1NC 2NO 2NC ALFD2 m 11DNUk ALFD2 m 20DNUk ALFD2 m 02DNUk AOLFD2 m 11DNUk AOLFD2 m 20DNUk AOLFD2 m 02DNUk Voltage Code 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC 66 11 22 QH2 QM4 m Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 6V secondary voltage (uses 6V LED). 1. 2. 3. 4. 5. Full Voltage 1NO-1NC 2NO 2NC ALD3l11DNUk ALD3l20DNUk ALD3l02DNUk AOLD3l11DNUk AOLD3l20DNUk AOLD3l02DNUk Transformer 1NO-1NC 2NO 2NC ALD3 m 11DNUk ALD3 m 20DNUk ALD3 m 02DNUk AOLD3 m 11DNUk AOLD3 m 20DNUk AOLD3 m 02DNUk In place of k, specify the Lens Color Code. In place of l, specify the Full Voltage Code (LED voltage). In place of m, specify the Transformer Voltage Code. Light is independent of switch position. Yellow pushbutton comes with white LED only. Circuit Breakers Terminal Blocks Contactors Timers o 40mm Mushroom Lens 756 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Illuminated Pushbuttons (Sub-Assembled) Transformer* + Contact Block + Operator + LED + Lens = Complete Part *Not required for full voltage types. Lamps Style Part Number Style Extended Momentary Maintained ALD2300T8 AOLD2300T8 LED k Lens Color Codes Voltage 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC Part Number LSTD-6l LSTD-1l LSTD-2l LSTD-H2l LSTD-M4l 40mm Mushroom ALD2300T8 Code A G R S W Y Color Amber Green Red Blue White Code A G R S W AOLFD2300T8 Relays & Sockets ALFD2300T8 Color Amber Green Red Blue White Yellow l LED Color Codes 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Extended with Full Shroud Signaling Lights Operators Yellow lens only. Yellow LED not available, use white LED. AOLD2300T8 Lenses Part Number 1NO 1NC Style Style Part Number All Control Units Extended ALN06LU-k HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) ALN3LU-k HW-DB Contactors Dummy Block o 40mm Mushroom Timers Contact Blocks 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining HW-U10R-F and HW-U01R-F result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Transformers In place of k, specify the Lens Color Code. Style Part Number 120V AC TW-F126B 240V AC TW-F246B 480V AC HW-L486 Lamp Circuit Components Style Long Lamp Holder Application Used with Full-size Transformer and two contact blocks Used with Full Voltage Adaptor and two contact blocks Lead Holder Part Number Transformers 6V secondary voltage (use 6V LED). TW-LH2 Full Voltage Modules Style HW-LH3 Description Dummy Block with Full Voltage Adaptor For use with odd number of contacts. Full Voltage Adaptor For use with even number Finger-Safe of contacts. Finger-Safe Part Number HW-DA1FBN Circuit Breakers Used with TW-LH2 holder when using four contact blocks Terminal Blocks Primary Voltage (50/60Hz) TW-DA1FB All Transformers step down to 6V (use 6V lamp). 1904041136 800-262-IDEC (4332) * USA & Canada 757 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Relays & Sockets Signaling Lights Non-Illuminated Selector Switches (Assembled) Assembled Selector Switches A S D 2 ( ) ( ) 11 Function Circuit Number S: Selector Switch (See Circuit # column of Selector Switch Contact Arrangement Chart on beginning on page 764.) Contactors Timers Series Designation D: TWND Series Contact Arrangement Code 2: 2-Position 3: 3-Position 10: 1NO 20: 2NO 40: 4NO 11: 1NO-1NC Spring Return Action Operator Style Code Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: 2-Way spring return from Left and Right Blank: Knob Operator L: Lever Operator K: Key Operator Number of Positions 01: 1NC 02: 2NC 04: 4NC 22: 2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom key removal codes available. Please contact IDEC for details. Circuit Breakers Terminal Blocks NU - ( ) 758 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Non-Illuminated Selector Switches (Assembled) Non-Illuminated 2-Position Selector Switches Style Part Number Mounting 1NO 1 2 O O X O 1NC 1 2 X O O O 1NO 1NC 1 2 O X X O 2NO 1 2 O O X X 2NC 1 2 X X O O 1 2 3 4 1 2 3 4 O X O X O O X X X O X O X X O O 2NO 2NC 2NO 2NC R Maintained L L R Spring Return from Left L R R Knob Lever Key Knob Lever Key Knob Lever Key Knob Lever Key Knob Lever Key ASD210NU ASD2L10NU ASD2K10NU ASD201NU ASD2L01NU ASD2K01NU ASD211NU ASD2L11NU ASD2K11NU ASD220NU ASD2L20NU ASD2K20NU ASD202NU ASD2L02NU ASD2K02NU ASD2110NU ASD21L10NU ASD21K10NU ASD2101NU ASD21L01NU ASD21K01NU ASD2111NU ASD21L11NU ASD21K11NU ASD2120NU ASD21L20NU ASD21K20NU ASD2102NU ASD21L02NU ASD21K02NU ASD2210NU ASD22L10NU ASD22K10NU ASD2201NU ASD22L01NU ASD22K01NU ASD2211NU ASD22L11NU ASD22K11NU ASD2220NU ASD22L20NU ASD22K20NU ASD2202NU ASD22L02NU ASD22K02NU Knob Lever Key ASD222NU ASD2L22NU ASD2K22NU ASD2122NU ASD21L22NU ASD21K22NU ASD2222NU ASD22L22NU ASD22K22NU Knob Lever Key ASD222NU-111 ASD2L22NU-111 ASD2K22NU-111 ASD2122NU-111 ASD21L22NU-111 ASD21K22NU-111 ASD2222NU-111 ASD22L22NU-111 ASD22K22NU-111 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Custom contact arrangements available, see page 764. Style Part Number Spring Return from Right Spring Return from Left C C C C Spring Return Two-Way O O O X Knob Lever Key ASD320NU ASD3L20NU ASD3K20NU ASD3120NU ASD31L20NU ASD31K20NU ASD3220NU ASD32L20NU ASD32K20NU ASD3320NU ASD33L20NU ASD33K20NU 2NC 1 2 O X X X X O Knob Lever Key ASD302NU ASD3L02NU ASD3K02NU ASD3102NU ASD31L02NU ASD31K02NU ASD3202NU ASD32L02NU ASD32K02NU ASD3302NU ASD33L02NU ASD33K02NU 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Knob Lever Key ASD322NU ASD3L22NU ASD3K22NU ASD3122NU ASD31L22NU ASD31K22NU ASD3222NU ASD32L22NU ASD32K22NU ASD3322NU ASD33L22NU ASD33K22NU 1 2 3 4 1 2 3 4 1 2 3 4 X X O O O O O O X O X O X O O X O X O X O X O X Knob Lever Key ASD322NU-309 ASD3L22NU-309 ASD3K22NU-309 ASD3122NU-309 ASD31L22NU-309 ASD31K22NU-309 ASD3222NU-309 ASD32L22NU-309 ASD32K22NU-309 ASD3322NU-309 ASD33L22NU-309 ASD33K22NU-309 Knob Lever Key ASD322NU-310 ASD3L22NU-310 ASD3K22NU-310 ASD3122NU-310 ASD31L22NU-310 ASD31K22NU-310 ASD3222NU-310 ASD32L22NU-310 ASD32K22NU-310 ASD3322NU-310 ASD33L22NU-310 ASD33K22NU-310 Knob Lever Key ASD340NU ASD3L40NU ASD3K40NU ASD3140NU ASD31L40NU ASD31K40NU ASD3240NU ASD32L40NU ASD32K40NU ASD3340NU ASD33L40NU ASD33K40NU 1 2 3 4 O X O X O X X O X O X O O O O O X X X X Knob Lever Key ASD304NU ASD3L04NU ASD3K04NU ASD3104NU ASD31L04NU ASD31K04NU ASD3204NU ASD32L04NU ASD32K04NU ASD3304NU ASD33L04NU ASD33K04NU 2NO 2NC 4NO 4NC X O X O R L 800-262-IDEC (4332) * USA & Canada R L R L C R Circuit Breakers X O L Terminal Blocks 1 2 R Contactors Mounting Maintained L Contact Operator Position 2NO 2NO 2NC 1904041136 Timers Non-Illuminated 3-Position Selector Switches Relays & Sockets L Spring Return from Right Signaling Lights Contact Operator Position 759 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o30mm - TWND Series Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks Relays & Sockets Timers Knob or Lever* + Color Insert* = Complete Part Handles and Inserts Position Description Knob/Lever 3 2 Key 3 Contactors + Operators 2 Part Number Maintained ASD0201T8 Spring return from right ASD0213T8 Spring return from left ASD0224T8 Maintained, Cam 1 Maintained, Cam 2 ASD0302T8 ASD0306T8 Spring return from right, Cam 1 Spring return from right, Cam 2 ASD0314T8 ASD0310T8 Spring return from left, Cam 1 Spring return from left, Cam 2 ASD0323T8 ASD0328T8 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASD0335T8 ASD0339T8 Maintained ASD0201KT8 Spring return from right ASD0213KT8 Spring return from left ASD0224KT8 Maintained, Cam 1 Maintained, Cam 2 ASD0302KT8 ASD0306KT8 Spring return from right, Cam 1 Spring return from right, Cam 2 ASD0302KT8B ASD0310KT8B Spring return from left, Cam 1 Spring return from left, Cam 2 ASD0323KT8 ASD0310KT8B Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASD0335KT8 ASD3K339KT8 Style ASDHHY-j Lever ASDHHL-j* Color Insert TW-HC1-j 1. In place of j, specify the Color Code. *Not available in yellow. Contact Blocks Style All Control Units Dummy Block Knob/Lever Color Code Black B Blue S Green G Red R Yellow Y White W Part Number Knob 1. Order knobs, levers, color inserts separately (see below). 2. For key switches, keys are removable in all maintained positions. Other options available, contact IDEC for details. 3. See page 766 "Operator Truth Tables" for details of difference between cams. j Color Codes Terminal Blocks Operator 1. *Not needed with key type switches. 2. Knob type shown. Style Circuit Breakers + Part Number 1NO 1NC HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining HW-U10R-F and HW-U01R-F result in overlapping contacts (remain on, or closed, when switch is moved between two positions). 1. Knob/Lever not available in white. 2. Color inserts not available in Black. 3. Lever not available in yellow. 760 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Illuminated Selector Switches (Assembled) Signaling Lights Assembled Illuminated Selector Switches SL D 2 (2) 22 11 DN U - 111 - R Function Lens Color Code SL:Illuminated Selector Switch A: Amber G: Green R: Red S: Blue W: White Y: Yellow Series Designation D: TWND series Number of Positions Relays & Sockets A Timers Circuit Code Number 2: 2-Position 3: 3-Position See Circuit # column of Selector Switch Contact Arrangement Charts on page 764. Spring Return Action Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: Two-Way spring return from Left and Right D: LED Lamp Contactors Rated Operational Voltage (Primary) Transformer Type 136: 120V AC 256: 240V AC 486: 480V AC Full Voltage Type 66: 6VAC/DC 11: 12VAC/DC 22: 24VAC/DC QH2: 120VAC QM4: 240VAC Terminal Blocks Contact Arrangement Code 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC 1904041136 800-262-IDEC (4332) * USA & Canada Circuit Breakers Use only when interpreting part numbers. Do not use for developing part numbers. 761 Switches & Pilot Devices Illuminated Selector Switches (Assembled) Illuminated 2-Position Selector Switches Mounting 1NO 1NC 1 2 1 2 1 2 1 2 3 4 1 2 3 4 2NO 2NC 2NO 2NC Relays & Sockets k Lens Color Codes Style Contact Signaling Lights Switches & Pilot Devices o30mm - TWND Series 2NO 2NC Part Number Operator Position L R O X O O X X O X O X O O X X X O X X O O X O X O X X O O Maintained Lamp Circuit Type L Spring Return from Left Spring Return from Right L R L R Transformer Full Voltage Transformer Full Voltage Transformer Full Voltage ASLD2 m11DNUk ASLD2l11DNUk ASLD2 m20DNUk ASLD2l20DNUk ASLD2 m02DNU-k ASLD2l02DNU-104-k ASLD21 m11DNUk ASLD21l11DNUk ASLD21 m20DNUk ASLD21l20DNUk ASLD21 m02DNU-k ASLD21l02DNU-k ASLD22 m11DNUk ASLD22l11DNUk ASLD22 m20DNUk ASLD22l20DNUk ASLD22 m02nDNU-k ASLD22l02DNU-k Transformer Full Voltage ASLD2 m22DNUk ASLD2l22DNUk ASLD21 m22DNUk ASLD21l22DNUk ASLD22 m22DNUk ASLD22l22DNUk Transformer Full Voltage ASLD2 m22DNU-111-k ASLD2l22DNU-111-k ASLD21 m22DNU-111-k ASLD21l22DNU-111-k 2NO 2NC 2NO 2NC 4NO 4NC Mounting Contact Timers 2NO 2NO 2NC Contactors A Green G Red R Blue S White W Yellow Y Voltage Code 6V AC/DC 66 12V AC/DC 11 24V AC/DC 22 120V AC QH2 240V AC QM4 Illuminated 3-Position Selector Switches, Maintained and Spring Return 2NC Terminal Blocks Code l Full Voltage Codes ASLD22 m22DNU-111-k ASLD22l22DNU-111-k Style Circuit Breakers R Color Amber 1 2 1 2 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Part Number Operator Position L C X O O X O O X X O O X X O X X O X O X O O O O O X X X X X O O X X X O O O O O O X O X O O X O X R O X X O O X X O X O O X O X O X O X O X X O X O Maintained Lamp Circuit Type L C Spring Return From Right L R C Spring Return from Left L R C R Spring Return Two-Way L C R Transformer Full Voltage Transformer Full Voltage ASLD3 m 20DNUk ASLD3l20DNUk ASLD3 m 02DNUk ASLD3l02DNUk ASLD31 m 20DNUk ASLD31l20DNUk ASLD31 m 02DNUk ASLD31l02DNUk ASLD32 m 20DNUk ASLD32l20DNUk ASLD32 m 02DNUk ASLD32l02DNUk ASLD33 m 20DNUk ASLD33l20DNUk ASLD33 m 02DNUk ASLD33l02DNUk Transformer Full Voltage ASLD3 m 22DNUk ASLD3l22DNUk ASLD31 m 22DNUk ASLD31l22DNUk ASLD32 m 22DNUk ASLD32l22DNUk ASLD33 m 22DNUk ASLD33l22DNUk Transformer Full Voltage ASLD3 m 22DNU-309-k ASLD3l22DNU-309-k ASLD31 m 22DNU-309-k ASLD31l22nDNU-309-k ASLD32 m 22DNU-309-k ASLD32l22DNU-309-k ASLD33 m 22DNU-309-k ASLD33l22DNU-309-k Transformer Full Voltage ASLD3 m 22DNU-310-k ASLD3l22DNU-310-k ASLD31 m 22DNU-310-k ASLD31l22DNU-310-k ASLD32 m 22DNU-310-k ASLD32l22DNU-310-k ASLD33 m 22DNU-310-k ASLD33l22DNU-310-k Transformer Full Voltage ASLD3 m 40DNUk ASLD3l40DNUk ASLD31 m 40DNUk ASLD31l40DNUk ASLD32 m 40DNUk ASLD32l40DNUk ASLD33 m 40DNUk ASLD33l40DNUk Transformer Full Voltage ASLD3 m 04DNUk ASLD3l04DNUk ASLD31 m 04DNUk ASLD31l04DNUk ASLD32 m 04DNUk ASLD32l04DNUk ASLD33 m 04DNUk ASLD33l04DNUk 1. In place of k, specify the Lens/LED Color Code, in place of l, specify the Full Voltage (LED voltage) Code, in place of m, specify the Transformer Voltage Code. 2. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these positions 3. Yellow selector switch comes with white LED. m Transformer Voltage Codes Voltage Code 120VAC 240VAC 480VAC 136 256 486 Transformers step down to 6V (use 6V LED). 762 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp + Lens = Complete Part Operators Style Lamp Circuit Components Position Description Part Number 2 Maintained ASLD0201T8 3 Maintained, Cam 1 Maintained, Cam 2 ASLD0302T8 ASLD0306T8 Spring return from right ASLD0213T8 Operator 3 Spring return from left ASLD0224T8 Spring return from right, Cam 1 Spring return from right, Cam 2 ASLD0314T8 ASLD0310T8 Spring return from left, Cam 1 Spring return from left, Cam 2 ASLD0323T8 ASLD0328T8 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASLD0335T8 ASLD0339T8 Lenses Style TW-LH2 Used with Full Voltage Adaptor and two contact blocks Lead Holder Used with TW-LH2 holder when using four contact blocks HW-LH3 Full Voltage Modules Style Description Dummy Block with Full Voltage Adaptor For use with odd number of contacts. Full Voltage Adaptor For use with even number Finger-Safe of contacts. Part Number Finger-Safe HW-DA1FBN TW-DA1FB All Transformers step down to 6V (use 6V lamp). Transformers Part Number LSTD-6l 12V AC/DC LSTD-1l 24V AC/DC LSTD-2l 120V AC LSTD-H2l 240V AC LSTD-M4l Style Transformers Part Number 120V AC TW-F126B 240V AC TW-F126B 480V AC HW-L486 6V secondary voltage. Contact Blocks k Lens Color Codes Part Number l LED Color Codes Color Code Color Code 1NO 1NC Amber A Amber A HW-U10-F HW-U10-F Green G Green G Red R Red R HW-U10R-F (early make) HW-U10R-F (late break) Blue S Blue S White W White W Yellow Y Yellow lens only. Yellow LED not available, use white LED. Circuit Breakers HW-DB Terminal Blocks Style Primary Voltage (50/60Hz) Contactors Voltage 6V AC/DC 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Dummy Block Used with Full-size Transformer and two contact blocks Long Lamp Holder k Lamps Part Number Timers ASLNHU-l All Control Units Application Part Number Knob LED Style Relays & Sockets 2 Style Signaling Lights *Not required for full voltage units. 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining HW-U10R-F and HW-U01R-F result in overlapping contacts (remain on, or closed, when switch is moved between two positions). 1904041136 800-262-IDEC (4332) * USA & Canada 763 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Contact Arrangement Charts L How to Read Contact Arrangement Charts Contact Block Mounting Position Circuit Number Signaling Lights * N/D = No designation Position or mounting contact blocks on operator Truth table indicates the operating position of contact block when operator is switched to that position. Contact Block Part Number X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed) when switch is moved between these two positions Part number to use when ordering sub-assembly contact blocks, as required for use with corresponding mounting position Contact Arrangement Chart: 2-Position Selector Switches Contact Circuit Number 1NO N/D 1NC N/D Timers Relays & Sockets Style N/D 1NO 1NC 103 Terminal Blocks Contactors 600 1NO-EM 1NC-LB 601 2NO N/D 2NC N/D N/D Circuit Breakers 2NO 2NC 110 111 4NO 764 N/D Mounting Position Operator Position 2 1 Operator Position Type and quantity of switch contacts 4 3 To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Contact Arrangement R Operator Part Number Contact Block Part Number L R 1 O X HW-U10-F 2 O O HW-DB 1 X O HW-U01-F 2 O O HW-DB 1 O X HW-U10-F 2 X O HW-U01-F 1 X O HW-U01-F 2 O X HW-U10-F 1 O X HW-U10R-F 2 X O HW-U01R-F 1 X O HW-U01R-F 2 O X HW-U10R-F 1 O X HW-U10-F 2 O X HW-U10-F 1 X O HW-U01-F 2 X O HW-U01-F 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 O X O X X O X O O O X X O O O O X O X O O X O X X X O O X X X X HW-U10-F HW-U01-F HW-U10-F HW-U01-F HW-U01-F HW-U10-F HW-U01-F HW-U10-F HW-U10-F HW-U10-F HW-U01-F HW-U01-F HW-U10-F HW-U10-F HW-U10-F HW-U10-F Description Maintained L R Spring Return from Right L R Spring Return from Left L R Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 Knob/Lever Key Illuminated Knob ASD0201T8 ASD0201KT8 ASLD0201T8 ASD0213T8 ASD0213KT8 ASLD0213T8 ASD0224T8 ASD0224KT8 ASLD0224T8 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Contact Arrangement Chart: 3-Position Selector Switches Style Operator Position Contact Circuit Number 202 1NO 1NC 302 N/D 2NO 301 304 N/D N/D 2NO 2NC 308 310 X O O HW-U10-F 2 X X O HW-U01-F 1 O X X HW-U01-F 2 O O X HW-U10-F 1 X O X HW-U10-F 2 X X O HW-U01-F 1 O X O HW-U01-F 2 O O X HW-U10-F 1 X O O HW-U10-F 2 O O X HW-U10-F 1 X O X HW-U10-F 2 O O X HW-U10-F 1 O X O HW-U01-F 2 X X O HW-U01-F 1 O X X HW-U01-F 2 X X O HW-U01-F 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 X O O X O O X O X X O X X X X X O X O X O O X O X O X HW-U10-F HW-U10-F HW-U01-F HW-U01-F HW-U01-F HW-U10-F HW-U01-F HW-U10-F HW-U10-F HW-U01-F HW-U10-F HW-U01-F HW-U10-F HW-U01-F HW-U01-F HW-U10-F HW-U01-F HW-U10-F HW-U01-F HW-U10-F O O O O X X X X X X O O O O O O X X O X O O X O X O X X O X O X O L C R L C R L C R L C R Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335KT8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335KT8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD310T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD310T8 ASD0328T8 ASD0328KT8 ASLD0323T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335KT8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD310T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD310T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335KT8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335KT8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335KT8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD310T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD310T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD310T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Terminal Blocks 309 1 R Contactors 210 C Two-Way Timers 2NC L Maintained Description Relays & Sockets 303 Contact Block Part Number Signaling Lights 203 Mounting Position Operator Part Number Spring Return Spring Return from Right from Left 1904041136 800-262-IDEC (4332) * USA & Canada 765 Circuit Breakers 1. Each operator sub-assembly is available as an "02" and an "06" for 3-position selector switches. The internal cam of an "02" is different from that of an "06". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Contact Arrangement Chart: 3-Position Selector Switches Style Operator Position Circuit Number Contact Mounting Position Signaling Lights N/D 4NO 305 Relays & Sockets N/D 4NC 314 L C 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 X O X O X O X O O X O O O O O O O O X 4 X R Maintained Description L X X X X O X O X X X X X X O X O O O O HW-U10-F HW-U10-F HW-U10-F HW-U10-F HW-U10-F HW-U10-F HW-U10-F HW-U10-F HW-U01-F HW-U01-F HW-U01-F HW-U01-F HW-U01-F HW-U01-F HW-U01-F X O HW-U01-F X X O X O X O Contact Block Part Number C R Operator Part Number Spring Return Spring Return from Right from Left L C L R C R Two-Way C L R Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335KT8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD0310T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASD0339T8 ASD0339KT8 ASLD0339T8 Knob/Lever Key Illuminated Knob ASD0302T8 ASD0302KT8 ASLD0302T8 ASD0314T8 ASD0314KT8 ASLD0314T8 ASD0323T8 ASD0323KT8 ASLD0323T8 ASD0335T8 ASD0335T8 ASD0335T8 Knob/Lever Key Illuminated Knob ASD0306T8 ASD0306KT8 ASLD0306T8 ASD0310T8 ASD0301KT8 ASLD0301T8 ASD0328T8 ASD0328KT8 ASLD0328T8 ASLD0339T8 ASD0339KT8 ASLD0339T8 Timers 1. Each operator sub-assembly is available as an "02" and an "06" for 3-position selector switches. The internal cam of an "02" is different from that of an "06". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches Contact Contactors HW-U10-F (NO) HW-U01-F (NC) ASLD0201T8 HW-U10R-F (NO-EM) Mounting Position Operator Position Left Right L O X R O X L X O R X O L O X R O X L X O R X O Contact HW-U10-F (NO) ASD0302T8 ASLD0302T8 ASD0302KT8 HW-U01-F (NC) HW-U10R-F (NO-EM) HW-U10R-F (NC-LB) Terminal Blocks HW-U01R-F (NC-LB) 3 Position Selector Switches Contact HW-U10-F (NO) Circuit Breakers ASD0306T8 ASLD0306T8 ASD0306KT8 HW-U01-F (NC) HW-U10R-F (NO-EM) HW-U01R-F (NC-LB) 766 www.IDEC.com Mounting Position Operator Position Left Center Right L X O O R O O X L O X X R X X O L X O O R O O X L O X X R X X O Operator Position Mounting Position Left L X O R O O X L O X O R X X O L X O X R O O X L O X O R X X O Center Right X 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Accessories -- TWND Series Item Lamp Removal Tool Plastic Bezel Rubber tool used to install or remove LED's Replacement locking ring/ bezel OR-55 Standard octagonal units (chrome-pl.). OG-81 Extended, non-illuminated (chrome-pl.). OG-82 Extended, illuminated (chrome-pl.). OG-83L Jumbo Mushroom Shallow Shroud ABN4G Jumbo Mushroom Deep Shroud ABN4F Black plastic locking ring/bezel Used to cover and protect pushbuttons Part Number OGP11B In place of j, specify Neoprene Rubber Boot color: B (black), G (green), R (red), Y (yellow) Relays & Sockets Boot/Cover Description/Usage Signaling Lights Metal Bezel Appearance OC-11 j Flush units (clear plastic -40 to +60C). OC-121 Extended units (clear plastic -40 to +60C). OC-122 Plastic washer For nameplates or panels that should not be scratched. OGL-D1T Thrust washer/Anti-rotation ring for use with notched panel cutout. OGL-D1S Anti-Rotation Ring Long Lamp Holder OB-11 Grey rubber (-5 to +60C) OB-13 Tab #250 17/64" x 3/64" (6.35mm x 0.8mm): Single tab Used with Transformer and two contact blocks Used with Full Voltage Adaptor and two contact blocks TW-FA4 TW-LH2 HW-LH3 Lock Out Adaptor Used to provide lockout protection for TWTD pushbuttons and knob selectors. o 1-13/64" (30mm) OL-KL1 Full Voltage Clips Primary Voltage (50/60Hz) Required for all full voltage pilot lights. Two pieces each. 2 clips required for full voltage pilot lights. APD-F Replacement Keys Pair of keys (#0) TW-SK 800-262-IDEC (4332) * USA & Canada Circuit Breakers Used with TW-LH2 holder when using four contact blocks Terminal Blocks Lead Holder 1904041136 Contactors Terminal Tab Adaptor Plugs used to fill unused 30mm panel cutouts. OBP-11 Metal with locking nut attached Timers Mounting Hole Plug Plastic with locking nut attached. 767 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o30mm - TWND Series Accessories TWND Series continued Item Appearance Description/Usage Part Number 1NC Contact Blocks (with side entry) These contacts are applicable for wires terminated by ring, fork, terminals, not recommended for bare wire connections. Contact Blocks (without side entry) These contacts are applicable for wires terminated by ring, fork, or ferule terminals, and also bare wire connections. 1NO HW-U01 HW-U01-MAU HW-U01R HW-U01R-MAU (with side entry) HW-U10 HW-U10-MAU HW-U10R HW-U10R-MAU (with side entry) HW-U01-F HW-U01-MAU-F HW-U01R-F HW-U01R-MAU-F (no side entry) HW-U10-F HW-U10-MAU-F HW-U10R-F HW-U10R-MAU-F (no side entry) Fingersafe Covers for TWND Series Description Used with Part Number Fingersafe terminal cover, for full voltage pilot lights, adds 3mm to overall depth Full voltage pilot lights APD-PVL Fingersafe terminal cover, adds 1.5mm to overall depth Transformer pilot lights N-VL3 Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Item 768 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Nameplates -- TWND Series Faceplates NALD NAKD 1.95" (50mm) 2.24" (57.5mm) O1.19" (30.5mm) O1.19" (30.5mm) Signaling Lights 1.85" (47.5mm) 1.95" (50mm) 2.03" (52mm) 1.56" (40mm) Dimensions NAQD O1.19" (30.5mm) 5mm Description Part Number NALD-B (black) NALD-R (red) NAKD-B (black) NAKD-R (red) NAQD-B (black) NAQD-R (red) Nameplate (engraved) NALD-j NAKD-j NAQD-j Relays & Sockets Nameplate (blank) 1. Nameplates are made of 0.031" aluminum. Lettering is white letters engraved on black background. 2. In place of j, insert either the standard legend code from table below or custom engraving delimited by " ". Standard Legend Codes Pushbuttons Legend OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP* STOP TEST UP I (Int'l On) O (Int'l Off) EMO Code 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 Legend AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER Code 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 Legend REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN Selector Switches Code 216 217 218 219 220 221 222 223 Legend AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO Code 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 Contactors 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 Pushbuttons/Selector Switches Legend Timers AUTO CLOSE DOWN EMERG.STOP* FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON Code Terminal Blocks 1. *Available in Red as standard legend code 104 and 124. To order engraved nameplate and codes, add legend code to nameplate part number. Character height based on the number of characters, space and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. Special engravings, additional cost. To specify engraving instructions, use the Nameplate order form on next page. Circuit Breakers 1904041136 800-262-IDEC (4332) * USA & Canada 769 Switches & Pilot Devices Custom engraved Nameplates Order Form -- TWND Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To ensure engraving accuracy, fax it to your IDEC representative. or Distributor. Your Company Name:__________________________________________ IDEC Rep/Distributor Contact:__________________________________ Your Name:__________________________________________ PO number (if known):__________________________________ Telephone:__________________________________________ IDEC Rep/Distributor Phone:__________________________________ Fax & Email:__________________________________________ IDEC Rep/Distributor Fax & Email:__________________________________ NALD Nameplate Step 1. Choose Letter Size - 7/64" or 1/8". Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 13 characters. Engraving Location Relays & Sockets Signaling Lights Switches & Pilot Devices o30mm - TWND Series Sample Letter Sizes 7/64" 16 characters max (for 7/64" size letters) 1/8" 13 characters max (for 1/8" size letters) Letter Size 7/64" Letters: 1/8" Letters: Letter Size Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. NAKD Nameplate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Step 1. Choose Letter Size - 7/64" or 1/8". Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 9 characters. Engraving Location Timers Qty Step 2. Enter the number of nameplates desired in the box on the right. 1 Sample Letter Sizes Qty 1/8" Letters: NAQD Nameplate Step 1. Choose Letter Size - 7/64" or 1/8". 1 2 3 7/64" 20 characters max (for 7/64" size letters) 1/8" 16 characters max (for 1/8" size letters) Letter Size Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8" size letters cannot exceed 16 characters. Engraving Location Terminal Blocks Contactors Specify Quantity. Letter Size 4 5 Circuit Breakers Step 2. 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Specify Quantity. Sample Letter Sizes Enter the number of nameplates desired in the box on the right. 3/32" Letters: 770 1/8" Letters: Qty www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Switch Engraving Order Form - TWND Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Telephone: Name: Fax: Address: Email: Signaling Lights Your Company: PO: Part Number to be Engraved: Please check one of the boxes below to indicate your choice of engraving options: o29mm, o40mm Mushroom Head 65mm Jumbo Mushroom Square Switch Engraving Engraving Area 1 # of Lines Letter Height Max. Characters Per Line 5/32 7 # of Lines 1 Letter Height Max. Characters Per Line 3/4 4 1 1/8 8 5/32 7 5/16 5/16 5 5 2 8 1/8 8 4 2 Custom* 4 Max. Characters Per Line 5/32 7 1/8 8 1 5/32 8 5/32 8 1/8 9 1/8 9 4 1 5 1/8 5 5/32 7 1/8 7 1. Above mentioned specifications hold true for standard size pushbuttons (round and square). 2. Engraving Area 2 can be engraved for 40mm mushroom head non-Illuminated pushbutton only. 3. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights. 4. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters. 5/32 7 1/8 8 Line 3: 1/8 8 Line 4: Line 2: 1/8 Letters: 5/32 Letters: Terminal Blocks 3 Engraving Area 2 5/32 Enter text to be engraved: Sample Letter Sizes Line 1: 2 1 Max. Characters Per Line Contactors Round Switch Letter Height 6 3 *Engraving is possible, but character size will be smaller than standard sizes. # of Lines 1/4 Engraving Area 1 Letter Height Timers 3 1/8 # of Lines Relays & Sockets Area 2 All engraving is 5/8mm wide. Custom* *Engraving is possible, but character size will be smaller than standard sizes. Circuit Breakers For IDEC Internal Use Only: Work Order #: 1904041136 800-262-IDEC (4332) * USA & Canada 771 Switches & Pilot Devices Dimensions (mm) Pushbutton o35 Mushroom Pushbutton w/Full Shroud 29.6 Panel Thickness 0.8 to 6.5 Mushroom Mushroom w/Full Shroud Jumbo Mushroom o 1.56" (40mm) 0.858" (22mm) 0.936" (24mm) 1.13" (29mm) o 1.56" (40mm) o 1.87" (48mm) o 2.54" (65mm) Mushroom, Pushlock Turn Reset and Push-Pull o 1.56" (40mm) *0.975" (25mm) **0.975" (25mm) o 1.56" (40mm) o 1.56" (40mm) 23.5 Illuminated Pushbuttons Full Voltage o24 o35 29.6 o39 Dimension A Dimension B Flush w/Full Shroud 0.975" (25mm) 0.995" (25.5mm) o 0.936" (24mm) o 0.936" (24mm) Extended w/Full Shroud 0.741" (19mm) 0.761" (19.5mm) o 0.936" (24mm) o 0.936" (24mm) o 1.56" (40mm) Mushroom Pushlock Turn Reset, Push-Pull *0.975" (25mm) **0.975" (25mm) o 1.56" (40mm) o 1.56" (40mm) 45.4 (1block) 65.4 (2 or 3 blocks) 85.4 (4 blocks) 29.4 40 23.6 Pilot Lights M3 Terminal Screw Panel Thickness 0.8 to 7.5 46 5 21.5 23.5 36 23.6 38 Illuminated Pushbuttons Panel Thickness 0.8 to 7.5 41.4 o24 o35 Panel Thickness 0.8 to 7.5 o24.6 o35 w/Transformer 40 *Dimension when operator is in reset position. **Dimension when operator is in pull position. Selector Switches Lever 90 2-position (3-position) 45 45 Panel Thickness 0.8 to 7.5 90 2-position (3-position) 45 45 25.1 o35 Panel Thickness 0.8 to 7.5 41.4 o25 o35 41.4 Key 90 2-position (3-position) 45 45 Panel Thickness 0.8 to 7.5 41.4 Knob o35 Timers o 0.975" (25mm) o 0.975"(25mm) o 1.11" (28.5mm) *Dimension when operator is in reset position. **Dimension when operator is in pull position. 45.4 65.4 75.5 (2 blocks), 95.5 (4 blocks) Contactors Dimension B 0.351" (9mm) 0.566" (14.5mm) 0.663" (17mm) o48 41.4 Signaling Lights 29.6 o39 9 65.4(3 or 4 blocks) 43.9 (1 or 2 blocks) 63.9 (3 or 4 blocks) Terminal Blocks Dimension A Flush Extended Extended w/Full Shroud 45.4 (1 or 2 blocks) Relays & Sockets Pushbuttons Panel Thickness 0.8 to 7.5 41.4 Switches & Pilot Devices o30mm - TWND Series 45.4 (1 or 2 blocks) 65.4 (3 or 4 blocks) 45.4 (1 or 2 blocks) 29.4 40 21.1 65.4 (3 or 4 blocks) 21.1 29.4 40 45.4 (1 or 2 blocks) 65.4 (3 or 4 blocks) 16.5 37.1 29.4 40 Illuminated Knob 90 2-position 45 (3-position) 45 Circuit Breakers o25 o35 Panel Thickness 0.8 to 7.5 45.4 65.4 75.5 (2 blocks), 95.5 (4 blocks) 772 27.6 29.6 40 www.IDEC.com 1904041136 Switches & Pilot Devices o30mm - TWND Series Switches & Pilot Devices Selector Switches Panel Cut-Out R0.8 max. 4.8 o3 0.5 + +0.2 0 33 +0.5 0 1. *Jumbo Mushroom < 2.61" (66mm) 2. Minimum mounting centers are applicable to switches with one stack of contact blocks. When mounting two stacks of contact blocks, minimum centers should allow for access to wiring. 3. The o 0.195" (o 5mm) recess is necessary when either the nameplate or anti-rotation ring is used. Square: 55 Round: 42 (*1) 0 0 .5 Signaling Lights 50 (*1) IlluminatedSelector Switches Pushbutton Clear Boot OGL-31 82.5 o32.6 93 30 70 Relays & Sockets 6.5 o3 4 o30 .5 18 (OC-31) 22 (OC-32) o3 9 o34 24.8 Waterproof Rubber Gasket 29.5 0.5t 30 0. o4 o40 o30 R6 Outside diameter: o50 Inside diameter: o44 Mounting Hole Rubber Plug 0.8 10 2.8 Panel Thickness 0.8 to 3.2 OB-31 Anti-Rotation Ring 5 OC-31 Lock-Out Adaptor 5 OL-KL1 2 Key Hole o8 Timers Finger-Safe Cover N-VL3 0 (6 .24" .2m m ) 1.20" (30.4mm) 0.63" (16mm) NVL3 (24mm) 0.41" (10.5mm) Contactors 0.19" (4.7mm) 0.94" 0.68" (17.2mm) APD-PVL Terminal Blocks .413" (10.5mm) .354" (9mm) m) .2m 1.45" (37mm) 1904041136 1.73" (44mm) Circuit Breakers APDPVL (6 1.26" (32mm) 6" .25 800-262-IDEC (4332) * USA & Canada 773 Switches & Pilot Devices Switches & Pilot Devices o30mm - TWND Series Operating Instructions Adjustment for Panel Thickness Insallation of LED Illuminated Units Each unit is shipped with several waterproof gaskets which are 0.06" (1.5mm) and 0.12" (3mm) thick. Combine the gaskets for a dimension approximately equal to panel thickness and install between the bezel and the body of the unit. Transformer units are recommended for use in areas subjected to inductive noise. Application Example For Push-To-Test Pilot Light A typical application of illuminated pushbuttons is a push-to-test pilot light which can be used to check the lamp/LED circuit. Signaling Lights Transformer/AC-Adapter Circuit Start Panel Cut-Out Unit Stop Trim Washer M2 L Thrust Washer C NC M2 Nameplate NO Relays & Sockets T Test Pilot Light Full Voltage Circuit Start Stop Selector Switches The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the Standard Operating Positions. OLS M A trim washer must be used with a thrust washer or a nameplate to prevent the control unit from rotating in the mounting hole. When using anti-rotation rings (trim washer with thrust washer or nameplate), install as shown below. Timers L L M NC NO T C L Test Pilot Light Standard Operation Positions 2-Position, 90 3-Position, 45 1 1 Contactors 0 2 2 Non-Illuminated 3-Position Operators 1 0 2 1 1 0 0 2 Circuit Breakers Terminal Blocks 2 774 www.IDEC.com 1904041136