USB2-GPIB Converter
User’s Manual
923571-00 Rev A
Foreword
Thank you for purchasing Teledyne LeCroy’s USB2-GPIB Converter (hereafter referred to as
“USB2-GPIB” or “adapter”.)
This manual describes notes on use and basic usage of the USB2-GPIB.
Before using this adapter, please read this manual thoroughly to gain a good understanding
of it. After reading, please keep the manual in a safe place.
© 2013 by Teledyne LeCroy, Inc. All rights reserved.
Teledyne LeCroy is a registered trademarks of Teledyne LeCroy, Inc. Other product or brand
names are trademarks or requested trademarks of their respective holders. Information in
this publication supersedes all earlier versions. Specifications are subject to change
without notice.
923571-00 Rev A
Sept 2013
1
Notes
Parts of the contents of this manual may be modified without prior notice
for improvements in performance and functions.
Reproduction or reprinting of the contents of this manual without prior
permission from Teledyne LeCroy is prohibited.
If you have questions about this adapter, please contact Teledyne LeCroy
at customersupport@teledynelecroy.com, 1-800-5-LeCroy.
Table of Contents
Overview .............................................................................................................................. 1
Safety Information.............................................................................................................. 2
Maintenance........................................................................................................................ 2
How to Use the USB2-GPIB............................................................................................. 3
(a) Connection............................................................................................................. 3
(b) Setting up the GPIB.............................................................................................. 4
(c) Communication Status....................................................................................... 5
(d) Firmware Upgrade................................................................................................ 6
Specifications...................................................................................................................... 7
Service .................................................................................................................................. 8
Warranty............................................................................................................................... 8
Certifications....................................................................................................................... 9
Overview
The USB2-GPIB Converter enables you to remotely control an oscilloscope from
a PC using standard GPIB commands.
The GPIB connector conforms to IEEE488.2 standard. Its delimiter setting is
LF+EOI.
The USB connector conforms to USB 2.0. For details of the GPIB commands,
see the Remote Control Manual on the Teledyne LeCroy website. Note that the
USB2-GPIB does not function as a controller.
• Minimum firmware version required for this device is 6.5.0.x.
2923571-00 Rev A
Maintenance
USB2-GPIB is a high quality, precision adapter. To maintain accuracy and
signal fidelity, avoid mechanical shock, as well as damage to the cable through
excessive bending. It is recommended to inspect cables before use to ensure they
are in good condition and are properly connected. Poor cables and/or connection
will result in data corruption.
Refer all maintenance and component replacement to qualified personnel. Do not
remove external covers in an attempt to clean internal parts.
Clean the outside of the USB2-GPIB with a soft cloth dampened with either
deionized / distilled water or isopropyl alcohol. Allow the surface to dry
completely before returning the adapter to service.
Safety Information
This symbol may appear on the product to alert you to additional
information contained in the operator’s manual. The corresponding
information in this guide is similarly denoted.
To avoid personal injury or damage to the USB2-GPIB or any equipment
connected to it, review and comply with the following safety precautions.
Use only as intended. Use of the USB2-GPIB and/or the equipment it is
connected to in a manner not specified by the manufacturer(s) may impair the
protection mechanisms.
Connect and disconnect properly. Do not connect or disconnect equipment to
the GPIB connector of the USB2-GPIB during data transfer. The green LED of
the USB2-GPIB stays lit while the communication is in progress. Disconnecting
equipment during this time may result in data corruption or equipment damage.
Do not use in wet/damp or explosive atmospheres.
For indoor use only. The USB2-GPIB is intended for indoor use and should be
operated in a clean, dry, environment.
Do not operate with suspected failures. Do not use USB2-GPIB if any part is
damaged. All maintenance should be referred to qualified service personnel.
Keep product surfaces clean and dry.
3
923571-00 Rev A
How to Use the USB2-GPIB
(a) Connection
As shown in Figure 1 below, insert the USB connector into the USB port of
the oscilloscope, then attach the IEEE-488/GPIB connector to the PC.
During the first use of the adaptor, Windows will install the device driver.
You may need to restart the oscilloscope for the adaptor to be functional.
Figure 1 Connection Diagram of GPIB Control
WaveRunner
WaveSurfer
PC
USB2-GPIB
GP-IB
connector
USB
port
4923571-00 Rev A
(b) Setting Up the GPIB
Set up the GPIB on the measurement screen of the oscilloscope (Figure 2)
following the steps shown below.
j Touch [Utilities] in the menu bar and select [Utilities Setup] from the
pull-down menu.
k Click the Remote tab in the setup area in the lower part of the screen.
l Select GPIB in the ‘Control From’ section.
m Select the GpibAddress and set an address by entering a value.
Figure 2 Remote Control Setup Screen of the WaveRunner 6 Zi
5
923571-00 Rev A
(c) Communication Status
The USB2-GPIB is equipped with two LEDs on the GPIB connector side to
indicate the communication status. The LEDs indicate the following statuses:
j Red READY LED is ON: Power to the USB2-GPIB is ON.
k Green ACTIVE LED blinks to indicate GPIB activity.
Figure 3 Drawing of USB2-GPIB
1
2
6923571-00 Rev A
b) Firmware Upgrade
After initial driver installation or an oscilloscope firmware upgrade, it may be
necessary to upgrade the dongle firmware on the USB2-GPIB. A pop up window
will appear to indicate incompatibility and instruct you to remove the device.
Follow these steps to upgrade the dongle firmware:
1. Download USB2-GPIB dongle firmware upgrade from teledynelecroy.com.
Extract this archive to a local folder of the controller computer
(e.g., C:\Temp).
2 Before reconnecting the USB2-GPIB device, open the Windows Device
Manager utility on your computer. Go to the Windows Start Menu and
choose Control Panel > System > Device Manager.
3. While pressing the dongle button underneath the case, plug the
USB2-GPIB dongle into the computer USB port. The dongle should show up
as AT32UC3A in the Windows Device Manager list of devices.
4. Install the Atmel USB DFU driver:
Right click on AT32UC3A in the Device Manager and choose
“Update Driver Software.”
If using Windows 7, choose “Browse my computer for driver software”,
if using Windows XP, choose “Install from a list or specific location
(Advanced).”
Browse to the “Atmel_DFU_USB_Driver” folder of the extracted
download archive.
The dongle should now show up as AT32UC3A3 under the “Atmel USB
Devices” folder of the Windows Device Manager list of devices.
5. Double-click the “DFU_UpgradeDongleFW.bat” file in the driver folder, which
will upgrade the dongle with the latest firmware. The dongle firmware
upgrade is successful if the red LED is on.
7
923571-00 Rev A
USB2-GPIB Specifications
Item Specifications
Power feed Bus-powered
USB standard Conforms to USB Specification Revision 2.0
USB connector Type A
GPIB connector Amphenol 24-pin (male)
Power consumption 350mA at the maximum (during operation)
Temperature, operating 5° to +40°C
Temperature, storage -40° to +71°C
Humidity, operating 80% RH (non-condensing)
Altitude, operating 3048 m (10,000 ft) max at 25°C
External dimensions 61 (W) × 22 (H) × 113 (L) (mm)
Cable length 750 (mm)
Mass Approx. 140 g
Notes:
• The source voltage is supplied from the USB port.
The appearance or parts of the specifications subject to change without
prior notice.
GPIB driver needs to be properly configured to allow HS488 high speed mode,
including proper definition of the cable length.
8923571-00 Rev A
Service
If the adapter is inoperable, send it back to Teledyne LeCroy. Contact us for a Return
Materials Authorization (RMA) number and shipping instructions before sending it. (Refer to
the contact information on page 1 of this manual.) We will repair it without charge as long
as it is under warranty.
When sending back the adapter, explicitly describe the following:
• RMA number
• Product name and serial number
• Description of the trouble
• Name/post/phone number of the owner.
Warranty
NOTE: THE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS, OR ADEQUACY FOR ANY PARTICULAR PURPOSE OR
USE. TELEDYNE LECROY SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT OR OTHERWISE. THE CUSTOMER
IS RESPONSIBLE FOR THE TRANSPORTATION AND INSURANCE CHARGES FOR THE
RETURN OF PRODUCTS TO THE SERVICE FACILITY. TELEDYNE LECROY WILL RETURN
ALL PRODUCTS UNDER WARRANTY WITH TRANSPORT PREPAID.
The adaptor is warranted for normal use and operation, within specifications, for a period
of three years from shipment. Teledyne LeCroy will either repair or, at our option, replace
any product returned to one of our authorized service centers within this period. However,
in order to do this we must first examine the product and find that it is defective due to
workmanship or materials and not due to misuse, neglect, accident, or abnormal conditions
or operation.
Teledyne LeCroy shall not be responsible for any defect, damage, or failure caused by any of
the following: a) attempted repairs or installations by personnel other than Teledyne LeCroy
representatives or b) improper connection to incompatible equipment, or c) for any damage
or malfunction caused by the use of non-Teledyne LeCroy supplies. Furthermore, Teledyne
LeCroy shall not be obligated to service a product that has been modified or integrated
where the modification or integration increases the task duration or difficulty of servicing
the adapter. Spare and replacement parts, and repairs, all have a 90-day warranty.
9
923571-00 Rev A
Certifications
EMC Compliance
EC DECLARATION OF CONFORMITY - EMC
The converter meets intent of EC Directive 2004/108/EC for Electromagnetic Compatibility.
Compliance was demonstrated to the following specifications as listed in the Official
Journal of the European Communities:
EN 61326‐1:2006, EN 61326‐2‐1:2006 EMC requirements for electrical equipment for
measurement, control, and laboratory use.
European Contact: Teledyne LeCroy Europe, GmbH
Waldhofer Str 104
D‐69123 Hidelberg, Germany
Tel: (49) 6221 82700
AUSTRALIA & NEW ZEALAND DECLARATION OF CONFORMITY - EMC
The converter complies with the EMC provision of the Radio Communications Act
per the following standards, in accordance with requirements imposed by Australian
Communication and Media Authority (ACMA):
CISPR 11:2003 Radiated and Conducted Emissions, Group 1, Class A, in accordance with
EN61326‐1:2006 and EN61326‐2‐1:2006.
Australia / New Zealand Contacts:
Safety Compliance
EC DECLARATION OF CONFORMITY - LOW VOLTAGE
The probe meets intent of EC Directive 2006/95/EC for Product Safety. Compliance was
demonstrated to the following specifications as listed in the Official Journal of the European
Communities:
EN 61010‐1:2010 Safety requirements for electrical equipment for measurement, control,
and laboratory use – Part 1: General requirements
EN 61010‐031/A1:2008 Safety requirements for electrical equipment for measurement,
control, and laboratory use – Part 031: Safety requirements for hand‐held probe assemblies
for electrical measurement and test.
Environmental Compliance
END-OF-LIFE HANDLING
The converter is marked with this symbol to indicate that it complies
with the applicable European Union requirements to Directives
2002/96/EC and 2006/66/EC on Waste Electrical and Electronic
Equipment (WEEE) and Batteries.
The converter is subject to disposal and recycling regulations that
vary by country and region. Many countries prohibit the disposal of
waste electronic equipment in standard waste receptacles. For more
information about proper disposal and recycling of your Teledyne
LeCroy product, please visit teledynelecroy.com/recycle.
RESTRICTION OF HAZARDOUS SUBSTANCES (RoHS)
The converter conforms to 2011/65/EU RoHS2 Directive based on the fact that it is
classified as Industrial Monitoring and Control Instrument (per Article 3, Paragraph 24) and
these product(s) & associated accessories are exempt from RoHS compliance until 22 July
2017 (per Article 4, Paragraph 3)
.
VICOM
1064 Centre Road
Oakleigh, South Victoria 3167
Australia
VICOM New Zealand Ltd.
60 Grafton Road
Auckland
New Zealand
Thank You for Purchasing
a USB2-GPIB
700 Chestnut Ridge Road
Chestnut Ridge, NJ 10977
1-800-5-LeCroy • teledynelecroy.com