Crompton Instruments Integra Digital Metering Systems Integra Digital Metering Systems The Integra digital metering product portfolio offers an extensive range of systems designed to suit any power monitoring application. Integra digital metering systems (dms) provide fully programmable, highly accurate measurement, display and communication of all major electrical and power quality parameters, including true rms system values, power quality data and measurement of total harmonic distortion. Designed to meet customer requirements, the Integra digital metering portfolio offers optional pulsed, analogue and digital communication outputs, DIN or ANSI case styles and high quality LED or LCD displays. Features * Measurement, display and communication of electrical and power parameters Contents DIN Integra Metering Specification Overview Page 3 * High contrast LED or LCD display Integra Ci3 Digital Metering System 4-5 * THD measurement and power quality data to 31st harmonic Integra Ri3 Digital Metering System 6-7 * True rms and average sensing measurement Integra 1630 Digital Metering System 8 - 11 * Pulsed, analogue and digital outputs Integra 1530 Digital Metering System 12 - 15 * Modbus RTU RS485 protocol, Johnson Controls and Lonworks protocol interface options Integra 1540 Digital Metering System 16 - 18 * Fully programmable VT and CT ratios Benefits * Pre-calibrated plug-in options * Simple menu driven interface * Remote monitoring * True three-and four-wire measurement Applications * Switchgear * Distribution systems * Generator sets * Control panels * Energy management * Utility power monitoring * Motor monitoring * Ground power units 2 Integra Communication and Configuration Software 19 DIN Integra Digital Metering Specification Overview 96mm (3.78") x 96mm (3.78") Panel cut-out 92mm x 92mm (3.62"x3.62") Din-rail mounting Dimensions 72 x 91 mm (2.83"x3.58") as per DIN 43880 110mm (4.31") x 110mm (4.31") Panel cut-out 103mm diam (4.06") 4 stud positions IP54 protection Single-phase system Single-phase 3-wire system 3-phase 3-wire system 3-phase 4-wire system 3-phase 4-wire with neutral CT 3-line 4-digit LCD display Graphical backlit LCD display 3-line 4-digit LED display Programmable display Programmable VT ratios Programmable CT ratios Configuration software option Measured parameters Voltage line-to-line Voltage line-to-neutral (4 wire system) System voltage Current L1, L2, L3 System current Neutral current calculated Neutral current measured Frequency 45-66Hz Demand current Max demand current Demand active power Max demand active power Power factor Active power kW Reactive power kVAr Apparent power kVA kW demand Active energy kWh import Reactive energy kVArh import Active energy kWh export Reactive energy kVArh export Voltage % THD average Voltage % THD L1, L2, L3 Current % THD average Current % THD L1, L2, L3 Hours run Communication options Digital RS485 Modbus RTU BACnet IP/MSTP Modbus TCP Pulsed output Analogue outputs Lonworks protocol Johnson Controls Metasys NII Standards Compliant with EN 61326-1 EN 61010-1 EN 62053-21 RoHS Compliant Approvals UL LISTED, UL 61010B-1, E203000 Integra Integra Integra Ci3 Ri3 1630 Integra Integra 1530 1540 3 Integra Ci3 Digital Metering System The Integra Ci3 meter is an accurate and cost effective solution for measurement and display of all major electrical and power quality parameters with easy programming, mounting and user friendly navigation. The product features a DIN 96 panel mounted enclosure, backlit LCD display and user programmable CT ratios, all accessible via an intuitive user interface. Integra Ci3 dms measures 17 electrical parameters including total harmonic distortion (THD) measurement up to the 31st harmonic. Programmable Functions Integra Ci3 dms is programmable to suit single-phase, three-phase three-wire and three-phase four-wire system configurations. Programmable CT ratios enable to display any current range. Display 6.1mm bezel depth The parameters can be viewed on a backlit LCD display. The 15 screens are accessible via four buttons on the front panel allowing to scroll between various screens making the navigation very user-friendly, intuitive and above all - simple. Plug-in Modules Integra Ci3 dms features two output options ports at the rear of the product. This allows to fit either pulsed relay or communication modules, e.g. Modbus RTU RS485 protocol communication output. Panel Mounting Easy `clip-in' mounting Integral retention clips allow fast, safe and secure panel mounting in various material thicknesses without the need for external screws or clips. Dimensions Panel cut-out 77.50 53.00 Features * * * * * * * DIN 96 enclosure Backlit LCD screen Bezel depth 6.1mm Plug-in output modules Programmable CT ratio True rms measurement User programmable system configuration Benefits * * * * * Cost effective Intuitive navigation Crompton renowned quality UK manufactured Easy `clip-in' panel mounting Standards * * * * IEC 61326 IEC 61010-1 IEC 62053-21 RoHS compliant 4 Product Code Description Part number Integra Ci3 base unit CI3-01 Options Pulsed output Modbus RTU RS485 protocol CI-PUL-01 CI-MOD-01 Accessories IP65 protective cover IP54 panel gasket 3 G365 02 3 C345 01 Programmable Parameters Parameter Range Password: System configuration: CT primary current: Demand integration time: 3 independent resets: Energy registers: Pulse output allocation: Pulse output duration: Pulse rate divisors: RS485 baud rate: RS485 parity and stop bits: 4-digit 0000-9999 1-phase 2-wire, 3-phase 3-wire, 3-phase 4-wire Maximum 9999A ** OFF 5, 8, 10, 15, 20, 30, 60 minutes Demands and maximum demands Kilo or mega None, kWh or KVArh 60, 100, 200 milliseconds 0.1, 1, 10, 100, 1000 2.4, 4.8, 9.6, 19.2, 38.4 kBd Odd or even with 1 stop bit or no parity with 1 or 2 stop bits 1-247 Normal or Reverse Comms Address: Floating point: Specifications Input Nominal input voltage Max. continuous input overload voltage Max. short duration voltage Nominal input voltage burden Nominal input current Max. continuous input overload current Max. short duration input current Frequency Auxiliary Operating range Accuracy Voltage (V) Current (A) Neutral current calculated (A) Frequency (Hz) Power factor (PF) Active power (W) Reactive power (VAr) Apparent power (VA) Active energy (kWh) Reactive energy (kVArh) THD Response time Output modules (optional) Pulsed output relays Contact rating Type Modbus RTU RS485 Protocol output module Type Baud rate Enclosure Enclosure style Panel cut-out Panel thickness Front protection rating Case protection rating Material Weight Terminals Environment Operating temperature Storage temperature Relative humidity Shock Vibration Dielectric voltage 100-289V AC L-N (173-500V AC L-L) 120% of nominal 2 x range maximum (1 second application input repeated 5 times at 5 minute intervals) < 0.2VA per phase 5A AC rms 120% of nominal 10 x nominal (1 second application repeated 5 times at 5 minute intervals) 45-66Hz 110-400V AC nominal +/-10% (99-440V AC absolute limits) or 120-350V DC +/-20% (96-420V DC absolute limits) 0.5% 0.5% 4% 0.1 Hz 1% of unity +/- 1% of range +/- 1% of range +/- 1% of range Class 1 (IEC 62053-21) +/- 1% of range 1% up to 31st harmonic 1 sec Parameters Button Screen Parameters V/Hz 1 Volts L1 - N Volts L2 - N Volts L3 - N Volts L1 - L2 Volts L2 - L3 Volts L3 - L1 Frequency Volts L1 - N THD% Volts L2 - N THD% Volts L3 - N THD% Volts L1 - L2 THD% Volts L2 - L3 THD% Volts L3 - L1 THD% 2 3 4 1 per module (2 modules fitted per Ci3) 50mA max at 250V AC Solid state relay 1 Modbus RTU RS485 Protocol channel per module (maximum of 1 module fitted per Ci3) 2-wire half duplex 2400, 4800, 9600, 19200, 38400 5 A 2 3 DIN 96 panel mount 92x92mm 1-5mm (1-3mm when used with IP65 cover) IP52 IP30 Polycarbonate to UL94V0 Ci3, 260g, Modbus 40g, pulsed 20g Shrouded screw-clamp 0.05-4mm wire -10C to +55C -20C to +70C 0-90% non-condensing 30g in 3 planes 10Hz to 50Hz Withstand test 3.25kV rms 50Hz for 1 minute between comms and measuring inputs, comm and aux, aux and measuring inputs 1 4 5 P/PF E 1 Current L1 Current L2 Current L3 Neutral Current L1 Current Max Demand L2 Current Max Demand L3 Current Max Demand Neutral Current Max Demand Current L1 THD% Current L2 THD% Current L3 THD% 2 3 kW kVAr kVA kW Max Demand Power Factor 1 2 kWh kVArh Connection 1-Phase 2-Wire 3-Phase 3-Wire 3-Phase 4-Wire 5 Integra Ri3 Digital Metering System The Integra Ri3 dms is an accurate and cost effective solution for measurement and display of all major electrical and power quality parameters with easy programming and user friendly navigation in DIN 43880 enclosure. The product features a DIN-rail enclosure, backlit LCD display and user programmable CT ratios, all accessible via an intuitive user interface. Integra Ri3 dms measures 17 electrical parameters including total harmonic distortion (THD) measurement up to the 31st harmonic. Programmable Functions Integra Ci3 dms is programmable to suit single-phase, three-phase three-wire and three-phase four-wire system configurations. Programmable CT ratios enable to display any current range. Features * * * * * DIN-rail enclosure DIN 43880 Backlit LCD screen Programmable CT ratio True rms measurement User programmable system configuration * Pulsed output and Modbus RTU RS485 protocol as standard Display The parameters can be viewed on a backlit LCD display. The 15 screens are accessible via four buttons on the front panel allowing to scroll between various screens making the navigation very user-friendly, intuitive and above all - simple. Output Modbus RTU RS485 protocol and pulsed output are available as standard. Dimensions Benefits * * * * Cost effective Simple navigation Crompton renowned quality UK manufactured Standards * IEC 61326 * IEC 61010-1 * IEC 62053-21 Product Codes Description Part number Integra Ri3 dms RI3-01 Programmable Parameters Parameter Range Password: 4-digit 0000-9999 System configuration: 1-phase 2-wire, 3-phase 3-wire, 3-phase 4-wire Demand integration time: OFF 5, 8, 10, 15, 20, 30, 60 minutes CT primary current: Maximum 9999A ** 3 independent resets: Demands and maximum demands Communications: Modbus RTU RS 485 or JC N2 RS485 baud rate: 2.4, 4.8, 9.6, 19.2, 38.4 kbps RS485 parity and stop bits: Odd or even with 1 stop bit or no parity with 1 or 2 stop bits 6 RS 485 Comms Address: 1-247 Modbus word order: Normal or reverse Pulse output allocation: Import or export kWh or import or export KVArh Pulse rate, rate per pulse: 0.001, 0.01, 0.1, 1, 10, 100, 1k, 10 k (max 2 pulses per sec) Pulse output duration: 60, 100, 200 milliseconds Energy units: Unit, lilo or mega Noise limit (1%): On or off Test: Display ON, TOGGLE or PHASE SEQUENCE Specifications Parameters Input Nominal input voltage Max. continuous input overload voltage Max. short duration input voltage Nominal input voltage burden Nominal input current Max. continuous input overload current Max. short duration input current Nominal input current burden Frequency System CT primary values Auxiliary Operating range Burden Accuracy Voltage (V) Current (A) Neutral current calculated (A) Frequency (Hz) Power factor (PF) Active power (W) Reactive power (VAr) Apparent power (VA) Active energy (kWh) Reactive energy (kVArh) THD Response time Output Pulse output relay Contact rating Type Modbus RTU RS485 protocol output module Type Baud rate Enclosure Enclosure style Front protection rating Case protection rating Material Weight Terminals Environment Operating temperature Storage temperature Relative humidity Shock Vibration Dielectric voltage 100-289V AC L-N (173-500V AC L-L) 120% of nominal Button Screen Parameters V/Hz Volts L1 - N Volts L2 - N Volts L3 - N Volts L1 - L2 Volts L2 - L3 Volts L3 - L1 Frequency Volts L1 - N THD% Volts L2 - N THD% Volts L3 - N THD% Volts L1 - L2 THD% Volts L2 - L3 THD% Volts L3 - L1 THD% 2 x range maximum (1 second application repeated 5 times at 5 minute intervals) < 0.2VA per phase 5A AC rms 120% of nominal 2 3 4 10 x nominal (1 second application repeated 5 times at 5 minute intervals) < 0.6VA per phase 45-66Hz 1 to 9999 5 A 110-400V AC nominal +/-10% (99-440V AC absolute limits) or 120-350V DC +/-20% (96-420V DC absolute limits) < 10VA/5W 0.5% 0.5% 4% 0.1 Hz 1% of unity +/- 1% of range +/- 1% of range +/- 1% of range Class 1 (IEC 62053-21) +/- 1% of range 1% up to 31st harmonic 1 sec 1 1 2 3 4 5 P/PF 1 50mA max at 250V AC Solid state relay 1 Modbus RTU RS485 protocol channel 2-wire half duplex 2400, 4800, 9600, 19200, 38400 E 1 Current L1 Current L2 Current L3 Neutral Current L1 Current Max Demand L2 Current Max Demand L3 Current Max Demand Neutral Current Max Demand Current L1 THD% Current L2 THD% Current L3 THD% 2 3 kW kVAr kVA kW Max Demand Power Factor 1 2 3 4 Import kWh Export kWh Import kVArh Export kVArh DIN-rail - DIN 43880 IP52 IP30 Polycarbonate to UL94V0 300g Shrouded screw-clamp 0.05-4mm wire -10C to +55C -20C to +70C 0-90% non-condensing 30g in 3 planes 10Hz to 50Hz Withstand test 3.25kV rms 50Hz for 1 minute between comms and measuring inputs, comm and aux, aux and measuring inputs Connection 3-Phase 3-Wire Single-Phase 2-Wire 3-Phase 4-Wire 7 Integra 1630 Digital Metering System The Integra 1630 digital metering system (dms) provides high accuracy 0.2% measurement, display and communication of all major electrical and power quality parameters including total harmonic distortion (THD) up to the 31st harmonic. To suit user requirements, the range includes single-phase, three-phase three-wire and three-phase four-wire capability, all selectable at the point of installation. This DIN 96 panel mounting enclosure offers simple programming and display of up to 35 electrical parameters via a simple menu-driven user interface on the front panel. Optional pulsed and digital communication outputs are available, to allow up to 60 parameters to be communicated to building management systems. A Windows-based software package is available to remotely configure the Integra dms and display all 60 major parameters. Operation Application * * * * * * * * Switchgear distribution systems Control panels Embedded generation Energy management Building management Utility power monitoring Process control Motor monitoring Features * Low profile * High contrast LED display * LED annunciators for each measured parameter * User programmable system configuration (4-wire default) * Fully programmable VT and CT ratios * Current demand per phase * Elapsed time counter for connected loads * Removable bezel for very low profile applications Benefits * True rms measurement * High accuracy <0.2% on some measurements * Configurable via software package or menu-driven interface * Import and export monitoring Standards * IEC1010-1 (BSEN 61010-1 - 2001) Integra 1630 dms offers uncomplicated operation and high accuracy measurement of three-phase voltage, current, frequency, Watts, VAr, VA, energy, power factor, and total harmonic distortion of both phase and system, current and voltage. Integra 1630 dms includes true measurement of both line-to-neutral, and line-to-line voltages, ensuring accurate readings. The pre-calibrated plug-in option cards allow cost effective upgrades with any combination of pulsed, analogue and digital communication outputs. Cards slot simply into the back of the unit and products do not need to be removed from the installation or recalibrated. Pulsed Outputs Integra 1630 meters offer optional single or dual pulsed outputs, programmable to represent import or export kWh, import or export kVArh or kVAh. The output pulses have programmable pulse rate divisor and pulse width. Modbus RTU RS485 Protocol Integra 1630 dms offers an RS485 communication port using the Modbus RTU RS485 protocol or the Johnson Controls Metasys NII protocol. Integra 1630 meter establishes the format for the master's query automatically, and responds with the correct protocol using IEEE floating point values. The Modbus RTU RS485 protocol option also offers user programmable word order and support for function 8 subfunction 0, return query data diagnostic. Modbus TCP (Ethernet) Integra 1630 dms options include an Ethernet communication module for connection to SCADA systems using the Modbus TCP protocol. The Integra 1630 dms with Ethernet option module acts as a Modbus slave device and may be queried by a Modbus master device. All messages sent to the Integra Ethernet interface must conform to the Modbus TCP protocol. For details see: http://www.modbus.org/docs/Modbus_Messaging_Implementation_Guide_V1_0b.pdf BACnet IP Interface Integra 1630 dms options include an Ethernet communication module for connection to SCADA systems using the BACnet IP protocol. The Integra 1630 dms acts as a server device and waits to receive commands from a BACnet/IP client. A BACnet/IP client (e.g. a SCADA system running on a PC), is used to instigate communication with the meter. All messages sent to the Integra Ethernet interface must conform to the BACnet IP protocol. For details on the protocol see the BACnet organisation website: http://www.bacnet.org/ BACnet MSTP Interface Dimensions Integra 1630 options include a BACnet MSTP module for connection via RS485 to SCADA or Building Automation and Management systems running BACnet MSTP clients. The Integra 1630 acts as a server device and waits to receive requests from a BACnet client that must conform to the BACnet MSTP Protocol. The module is fitted with a three-way screw terminal block to daisy-chain the BACnet communications cable. Standard RS485 communications cable should be used. Note that with this interface option fitted, there are no other external communication protocols available and pulsed relay outputs are not fitted. Programmable Display A two-button interface on the front panel provides configuration programming of system (e.g. three-phase four-wire), VT and CT ratio settings, selected communication options and adjustment of operating parameters. All set-up screens offer password protection. Status information can be viewed by scrolling through 16 screens featuring a high contrast three-line, four-digit LED display, with separate annunciators for each of the 35 measured parameters. 8 Product Codes Measurement and Display Description Cat. no. 1-phase, 3-phase 3/4-wire, 100-240V L-L, 5A CT input, Aux. 100-250V AC/DC INT-1630-L-5-M-option 1-phase, 3-phase 3/4-wire, 241-480V L-L, 5A CT input, Aux. 100-250V AC/DC INT-1630-M-5-M-option Options No options 000 1 pulsed output 100 2 pulsed outputs 200 Modbus RTU RS485 protocol 010 Modbus RTU RS485 protocol + 1kWhr pulsed output 110 Modbus RTU RS485 protocol + 2kWhr pulsed outputs 210 Modbus RTU RS485 protocol TCP 070 BACnet IP interface 080 BACnet MSTP interface 090 Extended collar OPT-1630-collar Programmable Parameters Parameter Range Password: 4-digit 0000-9999 CT primary current: Maximum 9999A ** CT Secondary Current: 5A (1A option) VT primary voltage: Maximum 400kV ** VT secondary voltage: Nominal input voltage ** maximum VT or CT ratios are limited so that the combination of primary voltage and current do not exceed 360MW at 120% of relevant input Demand integration time: 8, 15, 20, 30, 60 minutes 3 independent resets: Demands and maximum demands Energy registers Hours run Pulse output duration: 60, 100, 200 milliseconds Pulse rate divisors: 1, 10, 100, 1000 RS485 baud rate: 4.8, 9.6, 19.2, 38.4 kBd RS485 parity and stop bits: Odd or even with 1 stop bit or no parity with 1 or 2 stop bits Specifications Nominal input voltage: 57.7 to 277V L-N, 100 to 480V L-L Max. continuous input voltage: 120% nominal Max. short duration input voltage: 2 x nominal for 1 second, repeated 10 times at 10 second intervals System VT ratios (primary): Any significant 4-digit integer value up to 400kV ** Nominal input voltage burden: < 0.2 VA Nominal input current: 5A (1A option) System CT primary values: Any integer value up to 9999A ** Max. continuous input current: 120% nominal Max. short duration input current: 20 x nominal for 1 second, repeated 5 times at 5 minute intervals Nominal input current burden: < 0.6 VA ** maximum CT and VT ratios are limited so that the combination of primary voltage and current do not exceed 360MW at 120% of relevant input Up to 35 electrical and power quality parameters can be configured and displayed. 1 System (average) volts System (average) current System (total) kW 2 System volts (average) THD% System current (average) THD% 3 Volts L1 - N Volts L2 - N Volts L3 - N (4-wire only) Volts L1 - L2 Volts L2 - L3 Volts L3 - L1 (3-wire only) 4 Volts L1 - N THD% Volts L2 - N THD% Volts L3 - N THD% (4-wire only) Volts L1 - L2 THD% Volts L2 - L3 THD% Volts L3 - L1 THD% (3-wire only) 5 Volts L1 - L2 Volts L2 - L3 Volts L3 - L1 (4-wire only) 6 Current L1 Current L2 Current L3 7 Current line 1 THD % Current line 2 THD % Current line 3 THD % 8 Neutral current (4-wire only) Frequency Power factor (overall) 9 kVAr kVA kW 10 kW Hr import (7-digit resolution) 11 kVArh import (7-digit resolution) 12 kW Hr export (7-digit resolution) 13 kVArh export (7-digit resolution) 14 kW demand Current demand 15 Maximum kW demand Maximum current demand 16 Hours run Panel cut-out 9 Specifications continued Output modules (optional) RS485 communications: 2-wire half duplex Baud rates: 4800, 9600, 19200, 38400 Pulsed: Solid state relays Pulse duration: 60, 100 or 200 milliseconds Contact rating: 50mA max at 250V AC max Pulsed outputs: Auxiliary Standard nominal supply: 1 or 2 100-250V AC or DC voltage: (85-287V AC absolute limits) (85-312V DC absolute limits) AC supply frequency range: 45-66Hz AC supply burden: 6VA Optional auxiliary DC supply: 12-48V DC (10.2-60V DC absolute limits) DC supply burden: 6VA Measuring ranges Voltage: 80-120% of nominal (functional 5-120%) Current: 5-120% of nominal Frequency: 45-66Hz Power factor: 0.8 capacitive-1-0.8 inductive (functional 4 quadrant, 0-1 lag/lead) THD: Up to 31st harmonic 0-40% Measured voltage >5% of range Measured current >5% of nominal Full accuracy of voltage >25% of range Full accuracy of current >25% of nominal Energy: 7-digit resolution Reference conditions Ambient temperature: 23 1C Input frequency: 50 or 60Hz 2% Input waveform: Sinusoidal (distortion factor < 0.005) Auxiliary supply voltage: Nominal 1% Auxiliary supply frequency: Nominal 1% AC auxiliary supply waveform: Sinusoidal (distortion factor < 0.05) Magnetic field of external origin: Terrestrial flux Accuracy 10 Voltage: 0.17% of range maximum Current: 0.17% of nominal Frequency: 0.15% of mid frequency Active power: 0.2% of range maximum Power factor: 1% of unity Reactive power (VAr): 0.5% of range maximum Apparent power (VA): 0.2% of range maximum THD: 1% Neutral current calculated: 0.95% of nominal Energy: 0.3% of range maximum (Better than class 1) IEC1036 Sect 4.6) kVArh: 0.6% of range maximum Temperature coefficient: Voltage and current typical: 0.013%/C Watts typical: 0.018%/C Specifications continued Enclosure Enclosure style: DIN 96 panel mount Compliant with: IEC 1010-1/ BSEN 61010-1 : 2001 CAT III, CE EMC and LVD directives Material: Polycarbonate Terminals: Shrouded screw-clamp 0.05mm to 4mm wire Dielectric voltage: Withstand test 3.25kV rms 50Hz for 1 minute between all electrical circuits Operating temperature: -20 to +60C Storage temperature: -30 to +80C Relative humidity: 0-90% (non condensing) Warm-up time: 1 minute Shock: 30g in 3 planes Vibration: 10-18Hz, 1.5mm peak-to-peak 18-150Hz @1g IP protection: IP54 Dimensions: 96mm wide x 96mm high x 79mm deep (max). Typically <60mm depth behind panel 3.78" wide x 3.78" high x 3.11" deep (max) Panel cut-out: 92mm x 92mm, 3.62" x 3.62" Wiring 11 Integra 1530 Digital Metering System The Integra 1530 series instruments provide high accuracy <0.2% measurement, display and communication of all major electrical and power quality parameters, including true rms system values, and total harmonic distortion (THD) up to the 31st harmonic. This DIN 96 panel mounting enclosure offers programming and display of up to 34 power measurement parameters. Optional pulsed, analogue and digital communication outputs, allow the communication of information of up to 50 measured parameters into building management systems. A Windows-based software package is available to remotely configure the Integra dms and display all 60 major parameters. Operation Application * * * * * * * * * Switchgear Distribution systems Control panels Embedded generation Energy management Building management Utility power monitoring Process control Motor monitoring Integra 1530 digital metering system (dms) offers uncomplicated operation and high accuracy measurement of three-phase voltage, current, frequency, Watts, VAr, VA, energy, power factor, and total harmonic distortion of both phase and system, current and voltage. Integra 1530 dms includes true measurement of both line-toneutral, and line-to-line voltages, ensuring accurate readings. System Input Designed for all low, medium and high voltage switchgear and distribution systems, the Integra 1530 meter offers programmable VT and CT ratio capability. Direct connection for up to 480V AC with 5A CT inputs is standard, and 1A CT inputs available as an option. Features Neutral CT Input Option * Measure and display up to 34 electrical and power parameters * Measure and communicate up to 50 electrical and power parameters * High-contrast red LED display * LED annunciators for each measured parameter * THD measurement and power quality data to 31st harmonic * True rms measurement * Pulsed, analogue and digital outputs * Modbus, Johnson Controls and Lonworks protocol interface options * Fully programmable VT and CT ratios Integra dms pre-calibrated plug-in option cards allow cost effective upgrades with combinations of pulsed, analogue and digital communication outputs. Cards slot simply into the back of the unit and products do not need to be removed from the installation or recalibrated. Benefits Lonworks Protocol Interface * Replaces multiple single function instruments * Pre-calibrated plug-in options * High accuracy <0.2% * Configurable via software package or menu driven interface * Import and export monitoring * Neutral CT input option * True 3-and 4-wire measurement The Lonworks protocol interface option is designed according to the LonMark Interoperability Guidelines version 3.2. This ensures Integra meters can be integrated into a single control network without requiring custom node or network tool development. Standards * UL file no: E20300 * UL 61010B-1 * IEC 1010-1/BSEN 61010-1 CAT III 12 Integra 1530 dms offers a three-phase four-wire version with a neutral 4th CT, allowing true neutral current measurement and protection in high harmonic environments. System Outputs Modbus RTU RS485 Integra 1530 meter offers a communication port for systems using Modbus RTU or Johnson Controls Metasys NII protocols. Modbus communications can be used together with pulse and analogue output options. Programmable Display A two-button interface on the front panel provides configuration programming of system (three-phase four-wire etc), VT and CT ratio settings, selected communication options and adjustment of operating parameters. All set-up screens offer password protection. Status information can be viewed by scrolling through 15 screens featuring a high contrast three-line, four-digit LED display, with separate annunciators for each of the 34 measured parameters. Product Codes Description Cat. no. 1-phase 2-wire 100-240V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1531-L-5-M-option 1-phase 2-wire 241-480V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1531-M-5-M-option 1-phase 3-wire 100-240V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1532-L-5-M-option 1-phase 3-wire 241-480V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1532-M-5-M-option 3-phase 3-wire 100-240V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1533-L-5-M-option 3-phase 3-wire 241-480V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1533-M-5-M-option 3-phase 4-wire 100-240V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1534-L-5-M-option 3-phase 4-wire 241-480V L-L, 5A CT input. Aux. 100-250V AC/DC INT-1534-M-5-M-option 3-phase 4-wire with true neutral measurement 100-240V L-L, 5A CT input, Aux 100-250V AC/DC INT-1535-L-5-M-option 3-phase 4-wire with true neutral measurement 241-480V L-L, 5A CT input, Aux 100-250V AC/DC INT-1535-M-5-M-option Options Lonworks protocol 030 1 analogue output (0/20mA) 001=1 2 analogue outputs (0/20mA) 002=1 Programmable Parameters Parameter Range Password: 4-digit, 0000-9999 Primary current: Max 9999:5A (360MW max**) VT primary: 400kV (360MW max**) Secondary voltage: Nominal system voltage ** maximum VT and CT ratios are limited so that the combination of primary voltage and current does not exceed 360MW at 120% of relevant input Demand integration time: 8, 15, 20, 30 and 60 minutes Reset: Max demand and active energy registers Pulse output duration: 60, 100, 200 ms Pulse rate divisors: 1, 10, 100, 1000 RS485 interface baud rate: 2.4, 4.8, 9.6, 19.2kB RS485 parity: Odd/even/no, 1 or 2 stop bits Modbus RTU RS485 protocol address: 1-247 Analogue outputs: User definable Measurement and Display Up to 34 electrical and power quality parameters can be configured and displayed on the Integra 1530 dms unit. 1 System volts System current System kW 2 System volts THD % System current THD % 3 Volts L1 - N (4-wire only) Volts L2 - N (4-wire only) Volts L3 - N (4-wire only) 4 Volts L1 - L2 Volts L2 - L3 Volts L3 - L1 5 Volts line 1 THD % Volts line 2 THD % Volts line 3 THD % 6 Current L1 Current L2 Current L3 7 Current line 1 THD % Current line 2 THD % Current line 3 THD % 8 Neutral current (4-wire only) Frequency Power factor 9 kVAr kVA kW 10 kWh import (7-digit resolution) 11 kVArh import (7-digit resolution) 12 kWh export (7-digit resolution) 13 kVArh export (7-digit resolution) 14 kW demand Current demand 15 kW maximum demand Current maximum demand Enhanced status information of up to 50 parameters can be communicated into building management systems via optional pulsed, analogue and digital outputs. 13 Specifications Dimensions 3.78" 96mm 3.78" 96mm FRONT DISPLAY AREA Nominal input voltage: 57.7 to 277V L-N, 100 to 480V L-L Max continuous input voltage: 120% of nominal Max short duration input voltage: 2 x for 1 second, repeated 10 times at 10 second intervals System VT ratios (primary): Any value up to 400kV ** Nominal input voltage burden: < 0.2 VA Nominal input current: 5A (1A option) System CT primary values: 9999:5A or 9999:1A max 360MW ** Max continuous input current: 120% nominal Max short duration current input: 20 x for 1 second, repeated 5 times at 5 second intervals Nominal input current burden: < 0.6 VA ** maximum VT and CT ratios are limited so the combination of primary voltage and current does not exceed 360MW at 120% of relevant input 5.87" 149mm 5.67" 144mm Outputs (optional) RS485 communications: Baud rates: Pulsed: Pulse duration: Pulsed outputs: Analogue outputs: Auxiliary Standard nominal supply voltage: 3.62" 92mm PANEL CUT-OUT AC supply frequency range: AC supply burden: Optional auxiliary DC supply: 3.62" 92mm MAX PANEL THICKNESS 0.19", 5mm DC supply burden: Measuring ranges Voltage: Current: Frequency: Power factor: THD: Energy: Reference conditions Ambient temperature: Input frequency: Input waveform: Auxiliary supply voltage: Auxiliary supply frequency: AC auxiliary supply waveform: Magnetic field of origin: Accuracy Voltage: Current: Frequency: Active power: Power factor: Reactive power (VAr): Apparent power (VA): THD: Neutral current calculated: Neutral current measured: Energy: 14 KVArh: Temperature coefficient: Watts typical: Update time: Analogue output: 2-wire half duplex 2400, 4800, 9600, 19200 Clean contact SPNO 60, 100 or 200 milliseconds 1 or 2 1 or 2 100-250V, AC or DC (85-287V, AC absolute) (85-312V, DC absolute) 45-66Hz 6VA 12-48V, DC (10.2-60V, DC absolute) 6 VA 80-120% of nominal (functional 5-120%) 5-120% of nominal 45-66Hz 0.8 capacitive - 1 - 0.8 inductive (functional 4 quadrant, 0-1 lag/lead) Up to 31st harmonic (0%-40%) 7-digit resolution 231C 50 or 60Hz 2% Sinusoidal (distortion factor < 0.005) Nominal 1% Nominal 1% Sinusoidal (distortion factor < 0.05) Terrestrial flux 0.17% of range maximum 0.17% of nominal 0.15% of mid frequency 0.2% of range maximum 1% of unity 0.5% of range maximum 0.2% of range maximum 1% 0.95% of nominal 0.17% 0.3% or range maximum (Better than class 1 IEC1036 Sect 4.6) 0.6% of range maximum Voltage & current typical: 0.013%/C 0.018%/C Display: 1 second. Optional digital port: 250ms 0.2% Specifications continued Enclosure Enclosure style: DIN 96 panel mount Compliant with: UL E20300, UL61010B-1, IEC 1010-1/ BSEN 61010-1 CATIII, EMC and LVD Material: Polycarbonate Terminals: Shrouded screw-clamp Dielectric voltage: Withstand test 3.25kV rms 50Hz for 1 minute between all electrical circuits Operating temperature: -20 to +60C Storage temperature: -30 to +80C Relative humidity: 0-90% (non condensing) Warm-up time: 1 minute Shock: 30g in 3 planes Vibration: 10-15Hz, 1.5mm peak-to-peak/15-150Hz @ 1g IP protection: IP54 Dimensions: 96mm wide x 96mm high x 149mm deep (max) 3.78" wide x 3.78" high x 5.87" deep (max) Panel cut-out: 92mm x 92mm, 3.62" x 3.62" Connections Single-phase Single-phase 3-wire 3-phase 3-wire 3-phase 4-wire 3-phase 4-wire with neutral CT 15 Integra 1540 Digital Metering System The Integra 1540 dms series provides programmable measurement, display and communication of up to 31 major electrical and power quality parameters including true rms system values, total harmonic distortion (THD) and power quality data. The menu-driven interface allows the programming of voltage, current, and power measurement parameters. Status of all parameters can be viewed through 13 screens on the thee-line, four-digit LED display. The Integra 1540 meter has pulsed and digital communication outputs. System Input Designed for all low, medium and high-voltage switchgear and distribution systems, the Integra 1540 digital metering system (dms) has customer programmable VT and CT ratio capability. Direct connection of up to 600V AC with 5A CT inputs is available as standard, and 1A CT input is available as an option. Application Pulsed Outputs * * * * * * * * * Integra 1540 dms offers an optional pulse output module. Outputs are pulsed proportionally to the rate of measured kWh active energy, with pulse width and rate programmable via the set-up screens. Switchgear Distribution systems Generator sets Control panels Energy management Building management Utility power monitoring Process control Motor monitoring Modbus RTU RS485 Integra 1540 dms offers an RS485 communication port for direct connection to SCADA systems using the Modbus RTU protocol, or the Johnson Controls Metasys NII protocol. The Modbus protocol establishes the format for the master's query and the slave's response; it contains the fields confirming the action taken, the data to be returned, and an error-checking field. The Modbus RTU option includes the ability to change Modbus word order to suit the requirements of the user. Features * Measurement, display and communication of up to 31 power parameters * THD measurement and power quality data * True rms measurement * Pulsed energy outputs * Digital communications * Fully programmable VT and CT ratios * Simple menu driven interface * ANSI case style * High quality LED display Programmable Display A two-button interface on the front panel provides configuration programming of system (e.g. three-phase four-wire), VT and CT ratio settings, selected communication options and adjustment of operating parameters. All set-up screens offer password protection. Status information can be viewed by scrolling through 13 screens featuring a high contrast 3-line, 4-digit LED display, with separate annunciators for each of the 31 measured parameters. Auxiliary Supply The Integra dms family should ideally be powered from a dedicated supply, either 100-250V AC or DC (85-280V AC Absolute or 85-312V DC Absolute) or 12-48V DC (10.2-60V DC absolute). However the device may be powered from the signal source, provided the source remains within the working range of the chosen auxiliary supply. Benefits * Replaces multiple single function instruments * Simple menu driven interface * Remote monitoring * Monitoring, control and protection of power assets Standards * UL file no: 140758 * IEC 1010/BSEN 61010-1 Fusing It is recommended that all voltage lines be fitted with 1 amp fuses. Safety/Ground Connections For safety reasons, all CT secondary connections should be grounded in accordance with local regulations. Product Codes Product code Product configuration INT-1544-***-5-*-option Integra 1540 dms 3-phase 4-wire 5A CT input INT-1543-***-5-*-option Integra 1540 dms 3-phase 3-wire 5A CT input Input voltage suffix *** 16 100 100V L-L (57.7V L-N) 110 110V L-L (63.5V L-N) 115 115V L-L (66.4V L-N) 120 120V L-L (69.3V L-N) 139 139V L-L (80.2V L-N) 208 208V L-L (120V L-N) 240 240V L-L (139V L-N) 277 277V L-L (160V L-N) 380 380V L-L (220V L-N) 400 400V L-L (230V L-N) 415 415V L-L (240V L-N) 480 480V L-L (277V L-N) 600 600V L-L (346V L-N) Product Codes continued Product code Product configuration Auxiliary voltage suffix* L 12-48V DC M 100-250V AC/DC Communications options M RS485 Modbus RTU or Johnson Controls Metasys NII W kWh pulsed output Order Code Example INT-1544-120-5-L-W Integra 1540 dms 3-phase 4-wire, 120V L-L (69.3 L-N) nominal voltage, 5A CT input, 12-48V DC auxiliary supply, with pulsed output option. Programmable Parameters Parameter Range Password 4-digit 0000-9999 Primary current Max 9999:5 (360MW max**) VT primary 400kV (360MW max**) ** maximum VT or CT ratios are limited so that the combination of primary voltage and current does exceed 360MW at 120% of relevant inputs Demand integration time 8, 15, 20, 30 minutes Reset Max demand and active energy registers Pulse output duration 60, 100, 200 milliseconds Pulse rate divisors 1, 10, 100, 1000 RS 485 interface baud rate 2.4, 4.8, 9.6, 19.2 kB RS 485 parity Odd/even/no. 1 or 2 stop bits Modbus address 1-247 Specifications Nominal input voltage: 57.7 to 346V L-N, 100 to 600V L-L Max continuous input voltage: 120% nominal Max short duration input voltage: Integra 1540 dms offers configuration, display and communication of up to 31 electrical and power quality parameters. 1. System volts System current System kW 2. System volts THD % System current THD % 3. Volts L1 - N Volts L2 - N Volts L3 - N 4. Volts L1 - L2 Volts L2 - L3 Volts L3 - L1 5. Volts line 1 THD % Volts line 2 THD % Volts line 3 THD % 6. Current L1 Current L2 Current L3 7. Current line 1 THD % Current line 2 THD % Current line 3 THD % 8. Neutral current Frequency Power factor 9. kVAr kVA kW 10. kWh (7-digit resolution) 11. kVArh (7-digit resolution) 12. kW demand Current demand 13. kW maximum demand Current maximum demand 2 x for 1 second, repeated 10 times at 10 second intervals System VT ratios (primary): 400kV or 360MW ** Nominal input voltage burden: < 0.2VA Nominal input current: 5A (1A option) System CT primary values: 9999:5A or 9999:1A max 360MW ** Max continuous input current: 120% nominal Max short duration current input: Measurement, Display and Communication 20 x for 1 second, repeated 5 times at 5 second intervals Nominal input current burden: < 0.6VA Outputs RS485 communications: 2-wire half duplex Baud rates: 2400, 4800, 9600, 19200 Pulsed: Clean contact SPNO, 100V DC 0.5A max Pulse duration: 60, 100 or 200 milliseconds Auxiliary Standard nominal supply voltage: 100-250V AC or DC (85-287V AC absolute) (85-312V DC absolute) AC supply frequency range: 45-66Hz AC supply burden: 6VA Optional auxiliary DC supply: 12-48V DC (10.2-60V DC absolute) DC supply burden: 6VA 17 Dimensions Specifications continued Measuring ranges Voltage: 50-120% of nominal (functional 5-120%) Current: 5-120% of nominal (50%-120% for THD) Frequency: 45-66Hz Power factor: 0.5 inductive - 1 - 0.8 capacitive THD: To 15th Harmonic V & A Energy: 7-digit resolution Accuracy Voltage: 0.1% of range 0.4% of reading Current: 0.1% of range 0.4% of reading Power: 0.1% of range 0.9% of reading THD: 1% Neutral current: 4% of range Energy: kWh 1% IEC1036 (PF 0.8-1-0.8) KVArh: 2% IEC1036 (PF 0.8-1-0.8) Temperature coefficient: 0.013%/C typical Update time: 500ms display 250ms optional digital port Enclosure Enclosure style: ANSI C39.1 Compliant With: UL 140758 and IEC 1010/BSEN 61010-1 Material: Polycarbonate front and base, steel case Terminals: Barrier terminal strip 6-32 binding head screw Dielectric voltage: Withstand test 3.25kV rms 50Hz for 1 minute between all electrical circuits Operating temperature: -20 to +70C Storage temperature: -30 to +80C Relative humidity: 0-95% (non condensing) Warm-up time: 1 minute Shock: 30g in 3 planes Vibration: 10-15Hz, 1.5mm peak to peak/15-150Hz@1g Enclosure integrity: IP54 (front face) Dimensions: 4.31" high x 4.31" wide x 6.7" deep 109.4mm high x 109.4mm wide x 170.2mm deep Panel cut-out: 4.06" (103mm) diameter, 4 stud positions Wiring Panel cut-out Input connections are made to screw-clamp terminals. Terminals for both current and voltage connections are sized to accept two #12 AWG (3mm2) solid or stranded wires, or ring lugs suitable for 6-32 screws. Connections for communications and pulse outputs use identical style terminals. Wiring 3-PHASE 3-WIRE UNBALANCED LOAD 3-phase 3-wire 3-PHASE 4-WIRE UNBALANCED LOAD 3-phase 4-wire DIGITAL METERING SYSTEM DIGITAL METERING SYSTEM 2 5 8 11 1 3 4 6 7 9 13 14 2 5 8 11 1 3 4 6 7 L N AUX SUPPLY L1 L2 L3 N 18 P1 S1 P1 S1 9 13 14 L N AUX SUPPLY L O A D L1 L2 L3 N P1 S1 P1 S1 P1 S1 L O A D INTEGRA Communication and Configuration Software INTEGRA software is a Windows style user interface enabling remote monitoring and configuration of Integra dms parameters, outputs, digital communications, pulsed relays, current and power demand. The software can be installed on any PC running Windows. The software allows the user to load and save configurations to a PC hard disk and to send and retrieve settings directly from the Integra dms. Settings can also be copied between individual Integra dms units. Up to 31 Integra dms units can be connected to a PC COM port via an RS485/RS232 converter, however, the software can only communicate with one Integra dms at a time. Status information of measured parameters is usually communicated into a building management system, but can also be monitored through the configuration software. The software queries the selected Integra dms every few seconds to obtain data which can be viewed on a dedicated measurements page. Features Password Security Access to Integra dms programmable parameters is password protected, however, settings and the electrical measurements can be viewed without entering the password. The access passwords entered on the PC must be identical to those stored inside the Integra dms. Operation The software is designed to provide two functions: to display and configure the parameters of an Integra dms unit, and to monitor the measured values of the selected Integra dms. The software is extremely simple to operate, featuring userfriendly navigation toolbars and drop-down menus. Options There are available three versions of INTEGRA dms software for download from our website. http://crompton-instruments.com/integra_swd.html - INT-SOFT - Version 1.0.19 for Integra 1530 and Integra 1560/1580 dms - Integra 1630 dms Configurator V 1.0.0 for Integra 1630 dms - Integra Ci3 dms Configurator v1.0.10 for Integra Ci3 dms * Remote metering * Remote status information * PC configuration of programmable parameters * Full access to each and every parameter * Upload and download Integra dms settings * View and edit Integra dms settings * Load and save parameter settings * Print data logs * Password protected Applications * * * * PC based communication systems SCADA Systems PLC interfacing Energy management systems INTEGRA dms software can be downloaded from www.http://crompton-instruments.com/integra_swd.html INT-SOFT window Menu Measurements: System window: Displays all measurement values System type, volts, current, max system power, secondary volts, nominal volts, firmware version, special product code Password: Existing password, new password, confirm password, change password Energy and demands: Demand period, demand interval, reset demands, pulse rate divisor, pulse width, reset energy Analogue outputs: Set-up of phase readings, output modes, operating mode, trim controls, output of power factor parameters Digital communications: Baud rate, parity, stop bits and unique address Read/write register: Display and modification of Modbus registers Configuration toolbar Description New configuration: Create new Integra dms configuration Open configuration file: Load an existing configuration from a disk file Save configuration file: Save the current configuration to a disk file Print configuration: Send the current configuration to a printer Online: Connect to the selected Integra dms Offline: Disconnect from the selected Integra dms Upload configuration: Upload the configuration from the selected Integra dms Download configuration: Send current configuration to the selected Integra dms Configure PC Enables setting of PC communications communications: TE DataX Software TE dataX software is an application for data collection, storage, real time data analytics and reporting of metered energy data. This provides an accurate insight into facility's energy consumption and enables to take proactive cost savings actions. Software is available from www.crompton-instruments.com 19 About TE Connectivity While TE Connectivity (TE) has made every reasonable effort to ensure the accuracy of the information in this catalogue, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalogue are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications. TE Connectivity and TE connectivity (logo) are trademarks. CROMPTON is a trademarks of Crompton Parkinson Limited and is used under licence. Other products or company names mentioned herein may be trademarks of their respective owners. TE Energy - innovative and economical solutions for the electrical power industry: cable accessories, connectors & fittings, insulators & insulation, surge arresters, switching equipment, street lighting, power measurement and control. Tyco Electronics UK Ltd TE Energy Freebournes Road Witham, Essex CM8 3AH Phone: +44 (0)870 870 7500 Fax: +44 (0)870 240 5287 Email: crompton.info@te.com www.crompton-instruments.com http://energy.te.com Registered office: Faraday Road, Dorcan Swindon, SN3 5HH Reg. no. 550 926 (c) Tyco Electronics UK Ltd CI-INSTR-INT-DMS-UK-05/12 TE Connectivity is a global, $14 billion company that designs and manufactures over 500,000 products that connect and protect the flow of power and data inside the products that touch every aspect of our lives. Our nearly 100,000 employees partner with customers in virtually every industry - from consumer electronics, energy and healthcare, to automotive, aerospace and communication networks - enabling smarter, faster, better technologies to connect products to possibilities.