Series 858, Relay Sockets with Industrial Relay Relay socket with industrial relay Coil voltage: 24 V DC 4 changeover contacts Relay socket with industrial relay Coil voltage: 24 V DC 4 changeover contacts (gold contacts) A1 - * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact. 14 14 11 12 24 11 12 24 A1 - 21 22 34 31 32 44 A2 + 21 22 34 31 32 44 A2 + 41 42 41 42 Description Item No. Pack. Unit Item No. Pack. Unit Relay socket with industrial relay, for DIN 35 rail 858-304 1 858-314 1 Technical Data Coil Coil voltage 24 V DC 24 V DC Rated Power 0.9 W 0.9 W Coil Current 36.9 mA 36.9 mA Operating Range 0.8 - 1.1 x V 0.8 - 1.1 x V Holding Voltage 50% of VN 50% of VN Release Voltage 0.1 x V 0.1 x V AgCe AgCe + 5 m Au 5A 50 mA* Contacts Contact Material Continuous Current Inrush Current Max. Switching Voltage Switching Power (Max.) AC1/AC15 15 A/4 s 15 A/4 s 250 V AC/ 30 V DC 30 V DC * 1250 VA/300 VA 1250 VA/300 VA 0.12 kW 0.12 kW 5 A at 30 V DC 5 A at 30 V DC 1-Phase Motor Load AC3 Switching Current (Max.) DC1 Min. Switching Load 12 V/100 mA 12 V/100 mA Switching Frequency Under Load 20 cycles/min. 20 cycles/min. Mechanical Life 20 x 106 switching operations 20 x 106 switching operations Electrical Life 1 x 10 switching operations 1 x 105 switching operations Response Time/Drop-Out Time/Bounce Time (typ.) 25 ms/25 ms/4 ms 25 ms/25 ms/4 ms Nominal Voltage Acc. to VDE 0110 Part 1/4.97, IEC 60664-1 250 V/2.5 kV/2 250 V/2.5 kV/2 Dielectric Strength Contact-Coil (1.2/50 s) 4 kV 4 kV Dielectric Strength Contact-Coil (AC, 1 min) 1.5 kV 1.5 kV 1 kV 1 kV General Specifications 5 Dielectric Strength Open Contact Dielectric Strength Contact-Contact 1.5 kV 1.5 kV Ambient Operating Temperature -25 C - +70 C -25 C - +70oC Storage Temperature -40oC - +80oC -40oC - +80oC 31 x 73 x 97, Height from upper-edge of DIN 35 rail 31 x 73 x 97, Height from upper-edge of DIN 35 rail Dimensions (mm) W x H x L o Wire Connecion Cross Sections Stripped Lengths o o CAGE CLAMP(R)S CAGE CLAMP(R)S 2 x 0.34 mm - 2 x 1.5 mm /1 x 2.5 mm /22 - 16 AWG 2 x 0.34 mm - 2 x 1.5 mm2/1 x 2.5 mm2/22 - 16 AWG 9 - 10 mm/0.37 in 9 - 10 mm/0.37 in 2 2 2 2 Series 858, Relay Sockets with Industrial Relay Relay socket with industrial relay Coil voltage: 120 V AC 4 changeover contacts Relay socket with industrial relay Coil voltage: 120 V AC 4 changeover contacts (gold contacts) A1 ~ * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact. 14 14 11 12 24 11 12 24 A1 ~ 21 22 34 31 32 44 A2 ~ 21 22 34 31 32 44 A2 ~ 41 42 41 42 Description Item No. Pack. Unit Item No. Pack. Unit Relay socket with industrial relay, for DIN 35 rail 858-507 1 858-517 1 Technical Data Coil Coil voltage 120 V AC 120 V AC Rated Power 1.2 VA 1.2 VA Coil Current 15 mA 15 mA Operating Range 0.8 - 1.1 x V 0.8 - 1.1 x V Holding Voltage 80% of VN 80% of VN Release Voltage 0.3 x V 0.3 x V AgCe AgCe + 5 m Au 5A 50 mA* Contacts Contact Material Continuous Current Inrush Current Max. Switching Voltage Switching Power (Max.) AC1/AC15 15 A/4 s 15 A/4 s 250 V AC/ 30 V DC 30 V DC * 1250 VA/300 VA 1250 VA/300 VA 0.12 kW 0.12 kW 5 A at 30 V DC 5 A at 30 V DC 1-Phase Motor Load AC3 Switching Current (Max.) DC1 Min. Switching Load 12 V/100 mA 12 V/100 mA Switching Frequency Under Load 20 cycles/min. 20 cycles/min. Mechanical Life 20 x 106 switching operations 20 x 106 switching operations Electrical Life 1 x 10 switching operations 1 x 105 switching operations Response Time/Drop-Out Time/Bounce Time (typ.) 25 ms/25 ms/4 ms 25 ms/25 ms/4 ms Nominal Voltage Acc. to VDE 0110 Part 1/4.97, IEC 60664-1 250 V/2.5 kV/2 250 V/2.5 kV/2 Dielectric Strength Contact-Coil (1.2/50 s) 4 kV 4 kV Dielectric Strength Contact-Coil (AC, 1 min) 1.5 kV 1.5 kV 1 kV 1 kV General Specifications 5 Dielectric Strength Open Contact Dielectric Strength Contact-Contact 1.5 kV 1.5 kV Ambient Operating Temperature -25 C - +70 C -25 C - +70oC Storage Temperature -40oC - +80oC -40oC - +80oC 31 x 73 x 97, Height from upper-edge of DIN 35 rail 31 x 73 x 97, Height from upper-edge of DIN 35 rail Dimensions (mm) W x H x L o Wire Connecion Cross Sections Stripped Lengths o o CAGE CLAMP(R)S CAGE CLAMP(R)S 2 x 0.34 mm - 2 x 1.5 mm /1 x 2.5 mm /22 - 16 AWG 2 x 0.34 mm - 2 x 1.5 mm2/1 x 2.5 mm2/22 - 16 AWG 9 - 10 mm/0.37 in 9 - 10 mm/0.37 in 2 2 2 2 Series 858, Relay Sockets with Industrial Relay Relay socket with industrial relay Coil voltage: 230 V AC 4 changeover contacts Relay socket with industrial relay Coil voltage: 230 V AC 4 changeover contacts (gold contacts) A1 ~ * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact. 14 14 11 12 24 11 12 24 A1 ~ 21 22 34 31 32 44 A2 ~ 21 22 34 31 32 44 A2 ~ 41 42 41 42 Description Item No. Pack. Unit Item No. Pack. Unit Relay socket with industrial relay, for DIN 35 rail 858-508 1 858-518 1 Technical Data Coil Coil voltage 230 V AC 230 V AC Rated Power 1.2 VA 1.2 VA Coil Current 8.3 mA 8.3 mA Operating Range 0.8 - 1.1 x V 0.8 - 1.1 x V Holding Voltage 80% of VN 80% of VN Release Voltage 0.3 x V 0.3 x V AgCe AgCe + 5 m Au 5A 50 mA* Contacts Contact Material Continuous Current Inrush Current Max. Switching Voltage Switching Power (Max.) AC1/AC15 15 A/4 s 15 A/4 s 250 V AC/ 30 V DC 30 V DC * 1250 VA/300 VA 1250 VA/300 VA 0.12 kW 0.12 kW 5 A at 30 V DC 5 A at 30 V DC 1-Phase Motor Load AC3 Switching Current (Max.) DC1 Min. Switching Load 12 V/100 mA 12 V/100 mA Switching Frequency Under Load 20 cycles/min. 20 cycles/min. Mechanical Life 20 x 106 switching operations 20 x 106 switching operations Electrical Life 1 x 10 switching operations 1 x 105 switching operations Response Time/Drop-Out Time/Bounce Time (typ.) 25 ms/25 ms/4 ms 25 ms/25 ms/4 ms Nominal Voltage Acc. to VDE 0110 Part 1/4.97, IEC 60664-1 250 V/2.5 kV/2 250 V/2.5 kV/2 Dielectric Strength Contact-Coil (1.2/50 s) 4 kV 4 kV Dielectric Strength Contact-Coil (AC, 1 min) 1.5 kV 1.5 kV 1 kV 1 kV General Specifications 5 Dielectric Strength Open Contact Dielectric Strength Contact-Contact 1.5 kV 1.5 kV Ambient Operating Temperature -25 C - +70 C -25 C - +70oC Storage Temperature -40oC - +80oC -40oC - +80oC 31 x 73 x 97, Height from upper-edge of DIN 35 rail 31 x 73 x 97, Height from upper-edge of DIN 35 rail Dimensions (mm) W x H x L o Wire Connecion Cross Sections Stripped Lengths o o CAGE CLAMP(R)S CAGE CLAMP(R)S 2 x 0.34 mm - 2 x 1.5 mm /1 x 2.5 mm /22 - 16 AWG 2 x 0.34 mm - 2 x 1.5 mm2/1 x 2.5 mm2/22 - 16 AWG 9 - 10 mm/0.37 in 9 - 10 mm/0.37 in 2 2 2 2 Series 858, Relay Sockets for Industrial Relay Relay socket for industrial relays 2 and 4 changeover contacts 42 A2 Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts. 32 22 A1 12 Description Item No. Pack. Unit Relay socket for industrial relays, for DIN 35 rail 858-100 1 Technical Data Nominal Input Voltage (VN) Max. Switching Voltage Max. Continuous Current Depending on relay; max. 250 V AC 250 V AC 4 x 8 A (4 changeover contacts); 2 x 12 A (2 changeover contacts) Max. Switching Power (resistive) Nominal Operating Mode Voltage Resistance Nominal Voltage Acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Degree of Protection Ambient Operating Temperature Storage Temperature Dimensions (mm) W x H x L Wire Connecion Stripped Lengths Cross Sections Standards/Specifications 4000 VA AC Conituous duty 4 kV (depending on relay) 250 V/4 kV/3 IP 20 -25oC - +70oC (depending on relay) -40oC - +80oC 31 x 38 x 97, Height from upper-edge of DIN 35 rail CAGE CLAMP(R)S 9 - 10 mm/0.37 in 2 x 0.34 mm2 - 2 x 1.5 mm2/1 x 2.5 mm2/22 - 16 AWG IEC60664/IEC60664A/DIN VDE0110 Degree of pollution 2 Overvoltage category 2 44 34 24 14 41 31 21 11 Item No. Pack. Unit Series 858, Accessories for Relay Socket Pluggable industrial relays 4 changeover contacts with integrated LED and recovery diode and manual operation 13.2 4.4 13.2 4.4 21,5 max 2 3 4 1 5 6 7 8 9 10 11 12 6 7 8 9 10 11 12 3 4 12.7 6.4 6.4 35 max 16.8 5 2 16.8 1 12.7 28 max 13 14 6.3 14 6.3 13 5,8 * In order to prevent the gold layer from being damaged, these values shall not be exceeded. Higher switching power leads to evaporation of the gold layer. The resulting deposits in the enclosure may cause sparkovers between the coil and the contact. Pluggable industrial relays 4 changeover contacts with integrated LED and manual operation Description Nominal Input Voltage (VN) Item No. Pack. Unit Nominal Input Voltage (VN) Item No. Pack. Unit Pluggable Industrial Relay 24 V DC 858-150 1 240 V AC 858-151 1 24 V DC* 858-152 1 240 V AC* 858-153 1 Technical Data Coil Coil voltage 24 V DC 240 V AC Rated Power 0.9 W 1.2 W Coil Current 36.9 mA 8.3 mA Operating Range 0.8 - 1.1 x V 0.8 - 1.1 x V Holding Voltage 50% of VN 80% of VN Release Voltage 0.1 x V 0.3 x V AgCe, AgCe + 5 m Au* AgCe, AgCe + 5 m Au* Contacts Contact Material Continuous Current 5 A* 5 A* 15 A/4 s 15 A/4 s 250 V AC/ 30 V DC 250 V AC/30 V DC * 1250 VA/300 VA 1250 VA/300 VA 0.12 kW 0.12 kW Switching Current (Max.) DC1 5 A at 30 V DC 5 A at 30 V DC Min. Switching Load 12 V/100 mA 12 V/100 mA Switching Frequency Under Load 20 cycles/min. 20 cycles/min. Mechanical Life 20 x 106 switching operations 20 x 106 switching operations Electrical Life 1 x 10 switching operations 1 x 105 switching operations Response Time/Drop-Out Time/Bounce Time (typ.) 25 ms/25 ms/4 ms 25 ms/25 ms/4 ms Nominal Voltage Acc. to VDE 0110 Part 1/4.97, IEC 60664-1 250 V/2.5 kV/2 250 V/2.5 kV/2 Dielectric Strength Contact-Coil (1.2/50 s) 4 kV 4 kV Dielectric Strength Contact-Coil (AC, 1 min) 1.5 kV 1.5 kV 1 kV 1 kV Inrush Current Max. Switching Voltage Switching Power (Max.) AC1/AC15 1-Phase Motor Load AC3 General Specifications Dielectric Strength Open Contact Dielectric Strength Contact-Contact Ambient Operating Temperature Mounting Distance in a Row Weight 5 1.5 kV 1.5 kV -25oC - +70oC -25oC - +70oC 6 mm 6 mm approx. 37 g approx. 37 g Series 858, Accessories Description Item No. Pack. Unit Holding Bracket for Industrial Relays 858-110 8 Description Item No. Pack. Unit Push-In Type Jumper Bar 858-402 200 Description Power Consumption at VN Item No. Pack. Unit Status Indication* 2.4 mA 788-120 1 1.9 mA 788-121 1 1.9 mA 788-122 1 2.1 mA 788-123 1 1.7 mA 788-124 1 1.6 mA 788-125 1 *Only required when using relays without integrated operating indicator. WAGO Corporation * N120 W19129 Freistadt Road * Germantown, Wisconsin 53022 Telephone: 800 / DIN Rail (346-7245) * Fax: 262 / 255-3232 * info.us@wago.com * www.wago.us