The Bel Power Solutions produces the industry’s broadest selection
of Linear power supplies with output voltages from 5 to 48 volts.
Rugged technology and proven design merge to create quiet, highly-
regulated, dependable DC power.
The Linear power supplies are approved to domestic and
international regulatory standards, and are CE Marked to the Low
Voltage Directive (LVD).
RoHS compatible for all six substances
Worldwide AC Input Capabilities:
100/120/220/230/240 VAC
±0.05% Output Regulation
Low Output Ripple
Mean Time Before Failure (MTBF) 300,000 Hours
CE marked to Low Voltage Directive
100% Burn-In
2 Year Warranty
Overvoltage Protection (OVP) Standard on 5 V Single Outputs, Optional
for other outputs under 48 V
Used in industrial and medical applications needing low noise/ripple
amplifiers, acoustic, broadcast, ATE and control equipment.
Linear Series
2
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
These optional overvoltage protection modules are offered for use with Linear Power Supplies. Each is user adjustable from 6.4 V to
34 V.
MODEL
CASE SIZE
OVP MODULES REQUIRED *
SINGLE OUTPUT
B, C, N, D
OVP-12G
E, F
OVP-24G
DUAL OUTPUT
AA, B, BB, CC
OVP-12G protects both outputs
E
OVP-24G protects both outputs
TRIPLE OUTPUT
AA, BAA, D
CBB, 131
DBB, DCC
OVP-12G protects both 12 V through 15 V outputs
PEAK CURRENT MODELS
N, BAA, CBB
131
OVP-12G protects any output not provided with built-in OVP
* Outputs with factory built-in OVP are indicated in the Voltage/Current Rating Chart for each model. OVP is not available for 48 V models.
Linear Series
3
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
Model Input
100 to 264 VAC
Nominal
Vout*
Max
Amps
Case
Type
Additional
Features
5 Vout
HA5-1.5/OVP-AG
5
1.5
B
A
HB5-3/OVP-AG
5
3
B
A, C
HC5-6/OVP-AG
5
6
C
A, C
HN5-9/OVP-AG
5
9
N
A, C
HD5-12/OVP-AG
5
12
D
A, C
HE5-18/OVP-AG
5
18
E
A, C
F5-25/OVP-AG
5
25
F
A, C, D, H
G5-35/OVP-AG
5
35
F
A, C, D, H
CP197-AG
5
50
F
A, C, D
12 to 15 Vout
HA15-0.9-AG
12
0.9
B
HB12-1.7-AG
12
1.7
B
C
HC12-3.4-AG
12
3.4
C
C
HN12-5.1-AG
12
5.1
N
C
HD12-6.8-AG
12
6.8
D
C
HE12-10.2-AG
12
10.2
E
C
F15-15-AG
12
16
F
C, D, H
HA15-0.9-AG
15*
0.9
B
HB15-1.5-AG
15
1.5
B
C
HC15-3-AG
15
3
C
C
HN15-4.5-AG
15
4.5
N
C
HD15-6-AG
15
6
D
C
HE15-9-AG
15
9
E
C
F15-15-AG
15*
15
F
C, D, H
Model Input
100 to 264 VAC
Nominal
Vout*
Max
Amps
Case
Type
Additional
Features
24 to 28 Vout
HA24-0.5-AG
24
0.5
B
HB24-1.2-AG
24
1.2
B
C
HC24-2.4-AG
24
2.4
C
C
HN24-3.6-AG
24
3.6
N
C
HD24-4.8-AG
24
4.8
D
C
HE24-7.2-AG
24
7.2
E
C
F24-12-AG
24
12
F
C, D, H
HA24-0.5-AG
28*
0.5
B
HB28-1-AG
28
1
B
C
HC28-2-AG
28
2
C
HN28-3-AG
28
3
N
C
HD28-4-AG
28
4
D
C
HE28-6-AG
28
6
E
C
F24-12-AG
28*
10
F
C, D, H
48 Vout
HB48-0.5-AG
48
0.5
B
HC48-1-AG
48
1
C
HD48-3-AG
48
3
D
C
HE48-4-AG
48
4
E
C
* May require jumpering or potentiometer adjustment.
Model numbers highlighted in yellow are not recommended
for new designs.
Case Type
Dimensions
inches
millimeters
AA
6.50 x 4.00 x 2.10
165.10 x 101.60 x 53.34
B
4.87 x 4.00 x 2.10
123.70 x 101.60 x 53.34
BAA
10.25 x 4.00 x 2.95
260.35 x 101.60 x 74.93
BB
7.00 x 4.87 x 2.95
177.80 x 123.70 x 74.93
C
5.62 x 4.87 x 2.95
142.75 x 123.70 x 74.93
CBB
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
CC
9.38 x 4.87 x 3.28
238.25 x 123.70 x 83.31
CP131
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
D
9.00 x 4.87 x 3.28
228.60 x 123.70 x 83.31
DBB
14.25 x 4.87 x 3.38
361.95 x 123.70 x 85.85
DCC
15.00 x 4.88 x 4.55
381.00 x 123.95 x 115.57
E
14.00 x 4.87 x 3.53
355.60 x 123.70 x 89.66
F
16.75 x 4.88 x 5.00
425.50 x 123.95 x 127.00
N
7.00 x 4.87 x 3.28
177.80 x 123.70 x 83.31
Additional Features:
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit & parallel operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by removing jumper W1.
H Model requires 100 LFM forced-air cooling above 75% of rated
output power at 50°C.
Linear Series
4
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
Model Input
100 to 264 VAC
Nominal
Vout*
Max
Amps
Case
Type
Additional
Features
5 to 15 Vout
HAA5-1.5/OVP-AG
+5, 5
1.5, 1.5
AA
A
HBB5-3/OVP-AG
+5, 5
3, 3
BB
A
HCC5-6/OVP-AG
+5, 5
6, 6
CC
A, C
HAA512-AG
5, 12 to 15
2, 0.5
AA
A
HBB512-AG
5, 12 to 15
3, 1.25
BB
A, C
HCC512-AG
5, 12 to 15
6, 2.5
CC
A, C
HAA15-0.8-AG
+12, 5*
1, 0.4
AA
C
HBB15-1.5-AG
+12, 5*
1.7, 0.7
BB
C
HAD12-0.4-AG
+12, 12
0.4, 0.4
B
B
HAA15-0.8-AG
+12, 12
1, 1
AA
C
HBB15-1.5-AG
+12, 12
1.7, 1.7
BB
C
HCC15-3-AG
+12, 12
3.4, 3.4
CC
C
HDD15-5-AG
+12, 12*
5, 5
E
C
HAA15-0.8-AG
+12, 15*
1, 0.8
AA
C
HBB15-1.5-AG
+12, 15*
1.7, 1.5
BB
C
HCC15-3-AG
+12, 15*
3.4, 3
CC
C
HDD15-5-AG
+12, 15*
5, 5
E
C
HAA15-0.8-AG
+15, 5*
0.8, 0.4
AA
C
HBB15-1.5-AG
+15, 5*
1.5, 0.7
BB
C
HAA15-0.8-AG
+15, 12*
0.8, 1
AA
C
HBB15-1.5-AG
+15, 12*
1.5, 1.7
BB
C
HCC15-3-AG
+15, 12*
3, 3.4
CC
C
HDD15-5-AG
15, 12*
5, 5
E
C
15 to 24 Vout
HAD15-0.4-AG
+15, 15
0.4, 0.4
B
B
HAA15-0.8-AG
+15, 15
0.8, 0.8
AA
C
HBB15-1.5-AG
+15, 15*
1.5, 1.5
BB
C
HCC15-3-AG
+15, 15*
3, 3
CC
C
HDD15-5-AG
+15, 15
5, 5
E
C
HAA24-0.6-AG
+24, 24
0.6, 0.6
AA
HBB24-1.2-AG
+24, 24
1.2, 1.2
BB
HCC24-2.4-AG
+24, 24
2.4, 2.4
CC
C
* May require jumpering or potentiometer adjustment.
Model numbers highlighted in yellow are not recommended
for new designs.
Case
Type
Dimensions
inches
millimeters
AA
6.50 x 4.00 x 2.10
165.10 x 101.60 x 53.34
B
4.87 x 4.00 x 2.10
123.70 x 101.60 x 53.34
BAA
10.25 x 4.00 x 2.95
260.35 x 101.60 x 74.93
BB
7.00 x 4.87 x 2.95
177.80 x 123.70 x 74.93
C
5.62 x 4.87 x 2.95
142.75 x 123.70 x 74.93
CBB
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
CC
9.38 x 4.87 x 3.28
238.25 x 123.70 x 83.31
CP131
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
D
9.00 x 4.87 x 3.28
228.60 x 123.70 x 83.31
DBB
14.25 x 4.87 x 3.38
361.95 x 123.70 x 85.85
DCC
15.00 x 4.88 x 4.55
381.00 x 123.95 x 115.57
E
14.00 x 4.87 x 3.53
355.60 x 123.70 x 89.66
F
16.75 x 4.88 x 5.00
425.50 x 123.95 x 127.00
N
7.00 x 4.87 x 3.28
177.80 x 123.70 x 83.31
Additional Features:
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel operation master/slave
capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by removing jumper W1.
H Model requires 100 LFM forced-air cooling above 75% of rated
output power at 50°C.
Linear Series
5
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
Unsigned output voltages are isolated and can be used as either + or - polarities.
Model Input
100 to 264 VAC
Nominal
Vout*
Max
Amps
Case Type
Additional
Features
5 to 24 Vout
HTAA-16W-AG
+5, +12, 5*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +12, 5*
3, 1, 0.4
BAA
A, C
HCAA-60W-AG
+5, +12, 5*
6, 1, 0.4
D
A, C
HCBB-75W-AG
5, +12, 5*
6, 1.7, 0.7
CBB
C
CP131-AG
5, +12, 5*
8, 1.7, 0.7
CP131
A, C
HDBB-105W-AG
5, +12, 5*
12, 1.7, 0.7
DBB
A, C
HTAA-16W-AG
5, +12, 12
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +12, 12
3, 1, 1
BAA
A, C
HCAA-60W-AG
+5, +12, 12
6, 1, 1
D
A, C
HCBB-75W-AG
5, +12, 12
6, 1.7, 1.7
CBB
C
CP131-AG
5, +12, 12
8, 1.7, 1.7
CP131
A, C
HDBB-105W-AG
5, +12, 12
12, 1.7, 1.7
DBB
C
HDCC-150W-AG
5, +12, 12
12, 3.4, 3.4
DCC
A, C
HTAA-16W-AG
5, +12, 15*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +12, 15*
3, 1, 0.8
BAA
A, C
HCAA-60W-AG
+5, +12, 15*
6, 1, 1
D
A, C
HCBB-75W-AG
5, +12, 15
6, 1.7, 1.5
CBB
C
CP131-AG
5, +12, 15
8, 1.7, 1.5
CP131
A, C
HDBB-105W-AG
5, +12, 15*
12, 1.7, 1.5
DBB
C
HDCC-150W-AG
5, +12, 15
12, 3.4, 3
DCC
A, C
HTAA-16W-AG
5, +15, 5*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +15, 5*
3, 0.8, 0.4
BAA
A, C
HCAA-60W-AG
+5, +15, 5*
6, 1, 0.4
D
A, C
HCBB-75W-AG
5, +15, 5*
6, 1.5, 0.7
CBB
C
CP131-AG
5, +15, 5*
8, 1.5, 0.7
CP131
A,
HDBB-105W-AG
5, +15, 5*
12, 1.5, 0.7
DBB
C
HTAA-16W-AG
5, +15, 12*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +15, 12*
3, 0.8, 1
BAA
A, C
HCAA-60W-AG
+5, +15, 12*
6, 1, 1
D
A, C
HCBB-75W-AG
5, +15, 12
6, 1.5, 1.7
CBB
C
CP131-AG
5, +15, 12
8, 1.5, 1.7
CP131
A, C
HDBB-105W-AG
5, +15, 12*
12, 1.5, 1.7
DBB
C
HDCC-150W-AG
5, +15, 12
12, 3, 3.4
DCC
A, C
HTAA-16W-AG
5, +15, 15*
2, 0.4, 0.4
AA
A
HBAA-40W-AG
5, +15, 15*
3, 0.8, 0.8
BAA
A, C
HCAA-60W-AG
+5, +15, 15*
6, 1, 1
D
A, C
HCBB-75W-AG
5, +15, 15
6, 1.5, 1.5
CBB
C
CP131-AG
5, +15, 15
8, 1.5, 1.5
CP131
A, C
HDBB-105W-AG
5, +15, 15*
12, 1.5, 1.5
DBB
C
HDCC-150W-AG
5, +15, 15
12, 3, 3
DCC
A, C
Case
Type
Dimensions
inches
millimeters
AA
6.50 x 4.00 x 2.10
165.10 x 101.60 x 53.34
B
4.87 x 4.00 x 2.10
123.70 x 101.60 x 53.34
BAA
10.25 x 4.00 x 2.95
260.35 x 101.60 x 74.93
BB
7.00 x 4.87 x 2.95
177.80 x 123.70 x 74.93
C
5.62 x 4.87 x 2.95
142.75 x 123.70 x 74.93
CBB
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
CC
9.38 x 4.87 x 3.28
238.25 x 123.70 x 83.31
CP131
11.00 x 4.87 x 3.28
279.40 x 123.70 x 83.31
D
9.00 x 4.87 x 3.28
228.60 x 123.70 x 83.31
DBB
14.25 x 4.87 x 3.38
361.95 x 123.70 x 85.85
DCC
15.00 x 4.88 x 4.55
381.00 x 123.95 x 115.57
E
14.00 x 4.87 x 3.53
355.60 x 123.70 x 89.66
F
16.75 x 4.88 x 5.00
425.50 x 123.95 x 127.00
N
7.00 x 4.87 x 3.28
177.80 x 123.70 x 83.31
Additional Features:
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel operation master/slave
capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by removing
jumper W1.
H Model requires 100 LFM forced-air cooling above 75%
of rated output power at 50°C.
* May require jumpering or potentiometer adjustment.
Model numbers highlighted in yellow are not
recommended for new designs.
Linear Series
6
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
AC Input Voltage 1, 2
Jumper selectable, shipped factory configured for
120 VAC operation. All models must be externally
fused for proper operation.
Fuse ratings are marked on each unit.
Consult factory for each unit’s fuse requirements.
100 VAC Tap
87
100
110
VAC
120 VAC Tap
220 VAC Tap
104
191
120
220
132
242
240 VAC Tap
209
240
264
Input Frequency
AC input.
47
63
Hz
Line Regulation
Output voltage charge for a 10% line change: F case models.
-0.01
+0.01
%
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
-1.0
-0.5
+1.0
+0.5
All other models.
-0.05
+0.05
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Output Adjustment
Minimum output adjustment range 3
-5
+5
%
Efficiency
5 volt outputs.
45
12 volt and 15 volt outputs.
55
%
24 volt and higher outputs.
60
Ripple and Noise 4
F case models.
3.0
mVPK-PK
5 volt, 12 volt, and 15 volt models.
5.0
mVPK-PK
All three terminal regulator outputs.
0.2
%PK-PK
24 volt through 48 volt models.
3.0 mVPK-PK plus 0.02%
of output voltage, max
Load Regulation
Output change for a 50% load change: F case models.
-0.02
+0.02
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
-1
-0.5
+1
+0.5
%
All other models.
-0.05
+0.05
Transient Response
Recovery time, to within 1% of initial set point due to a 50% load
change.
50
μs
1
Derate output current 10% for 50Hz operation.
2
Input voltage tolerance for 230 VAC operation is +15%, -10%.
3
Output voltage adjustments can be made to within ±5% of factory setting of nominal output voltage.
Locate the “Vadj” potentiometer on the power supply PCB and use a screwdriver to adjust the output pot.
The HAD12 and HAD15 3 terminal regulator outputs are not adjustable.
4
Full load, 20 MHz bandwidth.
Linear Series
7
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Dielectric Withstand
Voltage
Input to case
Input to output (tested by manufacturer only)
2121
4242
VDC
Electromagnetic
FCC CFR title 47 Part 15 Sub-Part B - conducted.
Interference
EN55022 / CISPR 22
conducted. EN55022 /
CISPR 22 radiated.
Compatible with system compliance to
Level B.
Leakage Current
Per EN60950 (264 VAC)
23
50
μA
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on 5 volt output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12
and OVP-24.
5.8
6.6
V
Remote Sense
Total voltage compensation for cable losses with respect to
the main output. Provided on models where indicated.
250
mV
Overcurrent/Short Circuit
Protection
Automatic current limit/foldback. Rated as a percentage of
output power.
115
120
140
%
Master/Slave Operation
For parallel operation of up to 6 units. Master/slave pin provided
on F case models only. Contact factory for application notes.
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Operating Temperature
Derate output power linearly above 50°C by
3% per °C.
@ 100% load
0
50
°C
@ 40% load
70
°C
Storage Temperature
-40
85
°C
Temperature Coefficient
0°C to 50°C (after 15 minute warm-up).
0.1
0.3
%/°C
24 hours after warm-up.
-0.3
+0.3
%
Shock
Operating.
20
GPK
Vibration
Random vibration from 10 Hz to 2 kHz, 3 axis.
6.15
GRMS
Relative Humidity
Non-Condensing.
5
95
%RH
Linear Series
8
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
Linear Series
9
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
Linear Series
10
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
Mechanical Dimensions of Case Types
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.