http://www.tracopower.com
Input Specifications
Input current at no load 1.8 Vout models: 35 / 20 mA typ.
(nominal input 24/48 Vin) 2.5/3.3 Vout models: 40 / 25 mA typ.
other models: 70 / 45 mA typ.
Input current at full load 1.8 Vout models: 760 / 380 mA typ.
(nominal input 24/48 Vin) 2.5/3.3 Vout models: 1030 / 510 mA typ.
other models: 1500 / 750 mA typ.
Input voltage variation (dv/dt) 5 V/ms, max.
(complies with ETS 300 132 part. 4.4)
Under voltage lockout 24 Vin models: 7 VDC min. / 8 VDC typ. / 9.2 VDC max.
48 Vin models: 15 VDC min. / 16 VDC typ. / 17.5 VDC max.
Surge voltage (100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
(with external components)
Please refer to Application note: www.tracopower.com/overview/ten30wi
ESD (input) EN 61000-4-2, perf. criteria B
Fast transient (input) EN 61000-4-4, perf. criteria A
Surge (input) EN 61000-4-5, perf. criteria B
Output Specifications
Voltage set accuracy ±1 %
Output voltage adjustment ±10 %
Regulation – Input variation Vin min. to Vin max. ±0.5 % max.
– Load variation 10 – 100 %: single output models: ±0.5 % max.
dual output models: ±1.0 % max. (balanced load)
±5 % max. (Load cross variation 25 % / 100 %)
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz Bandwidth): 75 mVpk-pk max.
Start up time (nominal Vin and constant resistive load) 10 ms typ.
Transient response setting time (25% load step change) 300 µs typ.
Short circuit protection indefinite (automatic recovery)
Over load protection 150 % of Iout max typ. foldback
Thermal shutdown at +115°C typ
Over voltage protection 1.8, 2.5 & 3.3 V output models: 3.9 V
5.0 V output models: 6.2 V
12 V output models: 15 V
15 V output models: 18 V
Minimum load (only for dual output models) 10% of rated max current
(operation at lower load
condition will not damage these converters, however,
they may not meet all listed specifications)
Capacitive load 1.8 / 2.5 Vout models: 65’000 µF max./ 33’000 µF max.
3.3 / 5.0 Vout models: 19’500 µF max./ 10’200 µF max.
12 / 15 Vout models: 3’300 µF max./ 1’100 µF max.
±12 / ±15 Vout models: ±1’000 µF max./ ±680 µF max. (per output)
DC/DC Converters
TEN 30WI 30 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Page 2 of 4