AC centrifugal fans - RadiCal(R) Series R2E220 RA O220 mm 50/60 50/60 Yes Yes oC g 108 107 2,100 2,050 -25...60 -25...60 1,300 1,300 UL RPM Capacitor Watts Ingress Protection Rating 115 230 Mass 529.7 541.5 Temperature range (1) R2E220-RA44-14 R2E220-RA38-13 Speed (1) VAC Power input CFM Ball bearings Nominal voltage Type Nominal Data Hertz Air flow Highlights: - Backward curved - 7-blade impeller, single phase motor - Thermal overload protector (TOP) wired internally - Mounting position: Any - Condensate discharge holes: None - Ingress protection of IP44; dependent on installation and position Material: Fiberglass reinforced composite Impeller: PA Direction of rotation: Clockwise, seen on rotor F IP44 IP44 8 2 Yes Yes (1) Nominal data at operating point with maximum load. Curves R2E220-RA44-14 Curves Druck p f s[Pa]fur Rho=1,2kg/m^3 0 50 100 150 200 250 qv [cfm] 300 350 400 450 500 550 480 1,8 440 420 1,7 400 1,6 380 1,5 360 1,4 340 320 1,3 300 1,2 280 pfs[Pa] 2 1,1 4 260 1 240 220 0,9 200 0,8 180 0,7 3 160 0,6 140 120 0,5 100 0,4 2 80 0,3 60 0,2 40 pf s[P a] 20 0 100 200 300 400 500 qv [m/h] 600 700 800 900 0,1 Pe rpm W (115V) dB(A) LwA Measurement: LU-130009 A 1 2455 92 0.81 69 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. A 2 2260 98 0.85 62 A 3 2100 100 0.88 60 A 4 2265 96 0.84 65 Suction-side noise levels: LWA as per ISO 13347, LPA measured at 1m distance to fan axis. A 5 A 6 A 7 The values given are valid under the measuring conditions mentioned and may vary accoring to the actual installation situation. A 8 1,9 460 p fs_E[IN H2O] 500 I A n With any deviation to the standard set-up, the specific values have to be checked and reviewed once installed or fitted. For detailed information on the measuring set-up, please contact ebm-papst. A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 R2E220-RA38-13 Curves Druck p f s[Pa]fur Rho=1,2kg/m^3 500 0 50 100 150 200 250 qv[cfm] 300 350 400 450 500 550 480 1,8 440 420 1,7 400 1,6 380 1,5 360 1,4 340 320 1,3 300 1,2 1,1 4 260 1 240 p fs_E[IN H2O] 280 pf s[Pa] 2 220 0,9 200 0,8 3 180 0,7 160 0,6 140 0,5 120 2 100 0,4 80 0,3 60 0,2 40 20 0 Pe rpm W (230V) dB(A) 0 50 100 150 200 250 300 350 400 450 500 550 qv[m^3/h] 600 650 700 750 800 850 pf s[P 1a] 900 950 0,1 0 A B 1 2450 102 0.46 69 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. A B 2 2220 106 0.46 62 A B 3 2050 107 0.47 60 A B 4 2215 105 0.46 65 Suction-side noise levels: LWA as per ISO 13347, LPA measured at 1m distance to fan axis. A 5 A 6 A 7 The values given are valid under the measuring conditions mentioned and may vary accoring to the actual installation situation. A 8 With any deviation to the standard set-up, the specific values have to be checked and reviewed once installed or fitted. For detailed information on the measuring set-up, please contact ebm-papst. A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 R2E220-RAXX-XX 2.80 (71+1) 2.51 (63.7) Depth of screw max. 5mm Connection line PFA 4G 0.5mm2, 4x brass lead tips crimped 0.08 (2) O0.27(5.5) 4X 17 3. 0 ) 0 35 .24 ( (8 6) 5 +1 .7 0) 2( 45 0 +2 2. 28 (5 8 +0 . 2 ) O9.92 (170) O9.53 (170) O6.10 (155) O6.3 (161) O8.66 (220) O1.06 (27+0.1) 0.08 (2) Accessory part: Inlet nozzle 09609-2-4013, not included in the standard scope of delivery LwA Measurement: LU-136805 1,9 460 I A n A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9